SDN40-24-100C
AC-DC CONVERTER, DIN RAIL, 1 O/P, 960W, 40A, 24V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SOLAHD
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:960W; Output Voltage - Output 1:24VDC; Output Current - Output 1:40A; Output 05X8379
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1008.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3** Power Supplies ## SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs to offer the most performance available from SolaHD. Essential industrial features such as Sag Immunity, Power Factor Correction, and universal voltage input have been retained in this series. Wide temperature operating range and parallel operation capability make the new SDN-C units suitable to a variety of industrial applications. ## Applications - Industrial Machine Control and Process Control E61379 E137632 E234790 - Conveying Equipment - Material Handling - Vending Machines - Packaging Equipment and Amusement Park Equipment - Semiconductor Fabrication Equipment - DeviceNet[TM] ## Features - Compact packaging to save space on the DIN rail - Visual diagnostic LEDs for input and output status at a glance - High MTBF means high reliability and long life - Higher efficiency saves energy and lowers amount of heat generated in panel - PowerBoost[TM] overload capability to start high inrush loads - Accepts Universal voltage 85-264 Vac, 50/60 Hz input - Active Power Factor Correction - Patented DIN rail mounting clip - User Adjustable output voltage accessible via front face - Parallel capability standard - Large, rugged, accessible screw terminals - Industrial grade design - -25[o] C to 60[o] C operation without derating - Fully tested and burned-in at factory - Highly efficient switching technology - Five year limited warranty ## Certifications and Compliances * ## All Models - Listed, Ind. Control Equipment, E61379 - UL 508, CSA C22.2 No. 107.1 - UL Recognized Component, ITE, E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition - - Low Voltage Directive - IEC/EN60950-1, 2nd Edition - Sag Immunity: SEMI F47 - RoHS Compliant Models SDN 20-24-100C, SDN 20-24-480CC, SDN 40-24-480C - UL Recognized Component, Haz. Loc., - E234790 - ISA 12.12.01, CSA C22.2 No. 213 - Class I, Division 2, Groups A, B, C, D ## Models SDN 5-24-100C, SDN 10-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C - UL Recognized Component, Haz. Loc., - E234790 - UL 60079-15/CSA E60079-15 - Class I, Zone 2, AEx nC IIC, Ex nC IIC - ® ATEX Directive - - EN60079-0, EN60079-15 - ® II 3 G, Ex nC IIC Gc ## Related Products - SDN-P series - SDP[TM] series - SCP series - SDU UPS ## Accessories - Chassis Mount Bracket (SDN-PMBRK2) * Refer to user manual for installation requirements when used in hazardous locations. Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 117 **3** Power Supplies The SolaHD Difference **==> picture [158 x 428] intentionally omitted <==** **----- Start of picture text -----**<br> Multiple output connections for<br>ease of wiring multiple devices<br>Visual diagnostic LEDs show<br>input and output status (see<br>table below)<br>Single or parallel use<br>selectable by user<br>Clearly labeled front panel<br>Multiple certifications for<br>versatility in applications<br>Automatically adjusts for global<br>Input voltages. No manual<br>intervention required.<br>**----- End of picture text -----**<br> **==> picture [172 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> Rugged metal housing<br>Large, IP20-rated, screw<br>terminals for #10 AWG/6 mm [2] ,<br>for quick, easy installation<br>DC OK Relay<br>|<br>|<br>Adjustable output voltage<br>**----- End of picture text -----**<br> **==> picture [302 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> f| No internal fan, no extra cooling<br>required in any power level<br>|<br>IND.CONT.EQ<br>USSHAOLISTED C ©<br>115/230V~2.2/1.0A 50/60 HZ<br>1676) ©)<br>Narrow width<br>saves panel space<br>**----- End of picture text -----**<br> ## LED Light Status Conditions ||**Normal**|**AC Power Loss**|**AC Input Low**|**No DC**|**High Load**|**Overload**|**Hot**|**Too Hot**| |---|---|---|---|---|---|---|---|---| |**Input**|Green|-|Yellow|Green|Green|Green|Green|Green| |**Output**|Green|-|Green|-|Yellow|Yellow|Green|-| |**Alarm**|-|-|-|Red|Yellow|Red|Yellow|Yellow| Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 118 **3** _ Power Supplies ## SDN-C Specifications (Single Phase) **Catalog Number Description SDN 5-24-100C SDN 10-24-100C** ~~ee ees~~ **Input Nominal Voltage** 115 - 230 Vac ~~Fo~~ **-AC Range** 85 - 264 Vac **-DC Range[1]** 90 - 375 Vdc ~~oo~~ **-Frequency** 43 - 67 Hz **Nominal Current[2]** 1.65 - 0.55 A 3.2 - 1.0 A ~~pt~~ **-Inrush current max.** Typ. < 15 A Typ.< 30 A **Efficiency (Losses[3] )** > 88% typ. (14 W) > 90% typ. (24 W) ~~rs rr~~ **Power Factor Correction** Active power factor correction to better than 0.92 **Output** ~~——————————————————e~~ **Nominal Voltage[4]** 24 V (23.5~28.5 Vdc Adj.) **-Tolerance** < ±2 % overall (combination Line, load, time and temperature related changes) ~~EE~~ **Initial Voltage Setting** 24.5 V ± 1% **-Ripple[5]** < 50 mVpp **PARD** PARD (Periodic and Random Deviation) = 100 mV peak-peak max ~~_~~ **Overvoltage Protection** > 30.5 but < 33 Vdc, auto recovery ~~>~~ **Power Back Immunity** < 35 V **Nominal Current** 5 A (120 W) 10 A (240 W) ~~esef~~ **-Peak Current[6]** 1.5 × Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc **-Short Circuit Current** 1.5 x Nominal Current at near zero volts at short circuit condition ~~Od~~ **-Current Limit** PowerBoost™ **Parallel Operation** Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting). ~~oo~~ **Holdup Time** >20 ms (Full load, 100 Vac Input @ Tamb=+25°C) to 95% output voltage **Voltage Fall Time** <150 mS from 95% to 10% rated voltage @ full load (Tamb=+25°C) **Line and Load Regulation** < 0.5% ~~SS) Ce~~ **General EMC:** EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 ~~a~~ **-Emissions** EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and ~~a~~ **-Immunity** level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard Storage: -40[o] C to + 85[o] C, Operation -25[o] C to +60[o] C full power, with linear derating to half power from 60 to 70[o] C (Convection cooling, no **Temperature[7]** forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. ~~ne~~ **MTBF[8]** > 550,000 hrs **Warranty** 5 Year Limited Warranty ~~NN~~ **General Protection/** Protected against continuous short -circuit, continuous overload, continuous open circuit. ~~a~~ **Safety** Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) ~~a~~ **Status Indicators** Relay: N.O. contact rated 200ma/50 Vdc **Installation** ~~a~~ **Fusing -Input** Internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for ~~a~~ **-Output** wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. **Mounting** Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. ~~Re~~ Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm ~~[2] ) for solid conductors. Screw torque: 4.4 lb-inch (~ 50 N-cm).~~ **Connections** Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm[2] ) for solid conductors. Screw torque: 7 lb-inch (~ 80 N-cm). ~~es~~ **Case** Fully enclosed metal housing with fine ventilation grid to keep out small parts. **-Free Space** 25 mm above and below, 10 mm left and right, 15 mm in front ~~_~~ 4.85 × 1.97 × 4.36 4.85 × 2.36 × 4.36 ~~a~~ **H x W x D inches in (mm)** ~~a~~ (123.0 × 50.0 × 110.0) (123.0 × 60.0 × 110.0) **Weight lbs (kg)** 1.1 (0.50) 1.7 (0.80) ~~es nr~~ 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 6. Peak current is calculated at 24 Volt levels. 7. Contact tech support for operation at -25[o] C. 8. Demonstrated through extended life test. Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 119 **3** [ Power Supplies SDN-C Specifications (Single Phase) **Catalog Number** ~~ee~~ **Description SDN 20-24-100C SDN 40-24-100C Input Nominal Voltage** 115 - 230 Vac ~~>~~ **-AC Range** ~~TNSd WT~~ 85 - 264 Vac **-DC Range[1]** 90 - 375 Vdc ~~ts~~ **-Frequency** 43 - 67 Hz **Nominal Current[2]** 6 - 3 A 12 - 4 A ~~>~~ **-Inrush current max.** < 40 A ~~oY~~ Typ. <60 A **Efficiency (Losses[3] )** > 92% (38 W) > 93 % (67 W) ~~es~~ **Power Factor Correction** Active power factor correction to better than 0.92 **Output** ~~ee~~ **Nominal Voltage[4]** 24 V (23.5~28.5 Vdc Adj.) **-Tolerance** < ±2 % overall (combination Line, load, time and temperature related changes) ~~oe~~ **Initial Voltage Setting** 24.5 V ± 1% **-Ripple[5]** <100 mVpp < 100 mVpp ~~eeef~~ **PARD** PARD (Periodic and Random Deviation) = 100 mV peak-peak max **Overvoltage Protection** > 30.5 but < 33 Vdc, auto recovery ~~oe~~ **Power Back Immunity** < 35 V ~~a~~ **Nominal Current** 20 A (480 W) 40 A (960 W) **-Peak Current[6]** 1.5 × Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc **-Short Circuit Current** 1.5 x Nominal Current at near zero volts at short circuit condition 1.8 x Nominal Current at or near zero volts at short circuit condition ~~ee~~ **-Current Limit** PowerBoost™ Switch selectable single unit or parallel unit operation. Units will not be ~~Ce~~ **Parallel Operation[7]** damaged by parallel operation (regardless of switch position setting). Active Paralleling ~~a~~ **Holdup Time** >20 mS (Full load, 100 Vac Input @ Tamb=+25°C) to 95% output voltage **Voltage Fall Time** <150 mS from 95% to 10% rated voltage @ full load (Tamb=+25°C) ~~oe~~ **Line and Load Regulation** < 0.5% **General EMC:** EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 EN61000-6-3, EN61000-6-4, Class B EN55011, EN55022 **-Emissions** Radiated and Conducted including Annex. A, EN61000-3-2 Radiated and Conducted including Annex A, EN61000-3-2, EN61000-3-3 EN61000-6-1, EN61000-6-2, EN61000-4-2 Level 4, EN61000EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, 4-3 Level 3, EN61000-4-4 Level 4 input and Level 3 output, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 **-Immunity** EN61000-4-5 Installation Class 4, EN61000-4-6 Level 3, input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4EN61000-4-8, EN61000-4-11, SEMI F47 Sag Immunity, Transient 11, IEC 61000-4-34 voltage dip immunity standard protection according to VDE 0160/W2 over entire load range. ~~**a**~~ Storage: -40[o] C to + 85[o] ~~ee~~ C, Operation -25[o] C to +60[o] C full power, with linear derating to half power from 60 to 70 ~~ee~~[o] C (Convection cooling, **Temperature[8]** no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. **MTBF[9]** > 450,000 hrs > 500,000 hours demonstrated ~~eeer~~ **Warranty** 5 Year Limited Warranty Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class 1 (IEC536), degree of protection IP20 **General Protection/Safety** ~~a~~ (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) **Status Indicators** Relay: N.O. contact rated 200ma/50 Vdc ~~Le~~ **Installation Fusing -Input** Internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads **-Output** if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. ~~eS a~~ **Mounting** Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm[2] ) Input: Screw terminals, connector size range: 16-10 AWG for solid conductors. Screw Torque: 4.4 lb-in (~ 50 N-cm). (1.5-6 mm[2] ) for solid conductors. Screw Torque: 4.4 lb-inch (~ 50 N-cm). **Connections[10]** Output: Two terminals per output, connector size range: 16-10 AWG Output: Two terminals per output, connector size range: 10-6 AWG ~~a~~ (1.5-6 mm[2] ) for solid conductors. Screw Torque: 7 lb-inch (~ 80 N-cm) (6-14 mm[2] ) for solid conductors. Screw Torque: 15.6 lb-inch (~ 176 N-cm) ~~a ee~~ **Case** Fully enclosed metal housing with fine ventilation grid to keep out small parts. **-Free Space** 25 - 40 mm above and below, 10 mm left and right, 15 mm in front ~~ee~~ **H x W x D inches in (mm)** 4.85 x 3.42 x 4.98 (123.0 x 87.0 x 127.0) 4.85 x 7.09 x 4.81 (123.0 x 180.0 x 122.0) ~~OO~~ **Weight lbs (kg)** 2.6 (1.20) 6.0 (2.75) 1. Not UL listed for DC input. 6. Peak current is calculated at 24 Volt levels. 2. Input current ratings are conservatively specified with low input, worst case 7. All models except the 40amp unit are capable of parallel operation by use of a efficiency and power factor. jumper pin, accessible by the end user. 40 amp unit will have active current sharing 3. Losses are heat dissipation in watts at full load, nominal input line. signal. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 8. Contact tech support for operation at -25[o] C. 9. Demonstrated through extended life test. 10. SDN 40-24-100C only = Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND). Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 120 > Power Supplies **3** | | SDN-C Specifications (Three Phase) |**Description**<br>~~ee~~|**Catalog Number**<br>~~ee~~|**Catalog Number**<br>~~ee~~|**Catalog Number**<br>~~ee~~|**Catalog Number**<br>~~ee~~| |---|---|---|---|---| ||**SDN 5-24-480C**<br>~~ee~~|**SDN 10-24-480C**<br>~~ee~~|**SDN 20-24-480CC**<br>~~ee~~|**SDN 40-24-480C**<br>~~ee~~| |**Input**||||| |**Nominal Voltage**|380 - 480 Vac|||| |**Two- phase input**|Yes1|||| |**-AC Range2**|320 - 540 Vac|||| |**-DC Range**|450 - 760 Vdc|450 - 760 Vdc|450 - 760 Vdc10|N/A| |**-Frequency**|50/60 Hz|||| |**Nominal Current3**|3 x 0.5 or 2 x 0.7 A|3 x 0.8 or 2 x 1.2 A|3 x 0.9 or 2 x 1.3 A|3 x 1.6 A| |**-Inrush current max.**|Typ. <25 A||Negligible|Negligible| |**Efficiency (Losses4)**|> 85%(18 W)|91.2%(23.6 W)|93%(42 W)|94%(78 W)| |**Power Factor Correction**|Power factor correction to meet EN61000-3-2 Class A||Active Power Factor Correction|| |**Output**||||| |**Turn on time**|**Output**<br>Typ. 1s|||| |**Voltage Rise Time**|ca. 5-20 ms||<100 ms full resistive load(Tamb=+25°C)|| |**Power Back Immunity**|<35 V|||| |**Overvoltage Protection**|>30.5 but <33 Vdc auto recovery|||| |**Nominal Voltage5**|24 V(23.5~28.5 Vdc Adj.)|||| |**Voltage Regulation**|< ±2 % overall|||| |**Initial Voltage Setting**|24.5 V ± 1%|||| |**-Ripple6**|<100 mVpp|||| |**PARD**<br>~~es~~|PARD = 100 mVpeak-peak max<br>~~rser~~||PARD = 200 mVpeak-peak max|| |**Nominal Current**<br>~~es~~|5 A (120 W)<br>~~rs~~|10 A (240 W)<br>~~er~~|20 A (480 W) (constant power, not<br>constant current)|40 A (960 W)| |**-Peak Current7**<br>~~es~~|6A,2×Nominal Current <2sec<br>~~rs ~~|12A,2×Nominal Current <2sec<br> ~~er~~|1.5×Nominal Current for 4 sec minimum while holdingvoltage > 20Vdc|| |**-Current Limit**|PowerBoost™|||| |**Derating**|typ. 6 W/oC|typ. 12 W/oC|typ. 24 W/oC|typ. 48 W/oC| |**Holdup Time**|>20 ms|||>15 ms| |**Voltage Fall Time**<br>~~es~~|<150 ms from 95% to 10% rated voltage @ full load(Tamb=+25°C)<br>||<50 ms from 95% to 10% rated voltage @ full load(Tamb=+25°C)<br>|| |**Parallel Operation8**<br>~~es~~|Single or Parallel operation selectable via front switch. For redundant<br>operation, use of external diode module is preferred<br>|||Active Paralleling<br>| |**General**<br>~~es~~||||| |**Case**<br>|Fullyenclosed metal housingwith fine ventilationgrid to keepout smallparts.<br>|||| |**Min. Required**<br>~~ee~~|25mm above and below or<br>15mm in front<br>~~ee~~<br>~~es ee~~|25mm above and below or<br>25mm above and below or<br>10mm in front<br>~~ee~~<br>~~ee~~|25mm above and below or<br>70mm above and below or<br>25mm in front and 25mm left & right<br>~~ee~~<br>~~ee~~|70mm above and below or<br>70mm above and below, 15mm in<br>front, 25mm left & right<br>~~ee~~<br>~~ee~~| |**Free Space**<br>~~ee~~<br>~~a~~||||| |**H×W×D inches (mm)**<br>~~ee~~<br>~~a~~|4.85 × 1.97 × 4.36<br>(123.0 × 50.0 × 111.0)<br>~~ee~~<br>~~es ee~~|4.85 × 2.36 × 4.36<br>(123.0 × 60.0 × 111.0)<br>~~ee~~<br>~~ee~~|4.85 x 3.35 x 4.68<br>(123.0 x 85.0 x 119.0)<br>~~ee~~<br>~~ee~~|4.85 x 7.09 x 4.66<br>(123.0 x 180.0 x 119.0)<br>~~ee~~<br>~~ee~~| |**Weight lbs (kg)**<br>~~a~~|1.2(.52)<br>~~es ee~~|1.5(0.70)<br>~~ee~~|2.9(1.30)<br>~~ee~~|5.3(2.40)<br>~~ee~~| |**EMC:-Emissions**<br>~~a ~~<br>~~ee~~|EN61000-6-3:2001,Class B EN55011,EN55022 Radiated and Conducted includingAnnex. A,EN61000-3-2<br> ~~es ee~~<br>~~ee~~<br>|||| |**-Immunity**<br>~~ee~~|EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3,<br>EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11<br>|||| |**Temperature**<br>~~eeae~~|Storage : -40 to + 85oC, Operation -25 to +60oC full power, with linear derating to half power from 60 to 70oC (Convection cooling, no forced air<br>required). Operation up to 50% load permissible with sideways or front side up mounting orientation.<br>~~ae~~|||| |**Humidity**<br>~~ae~~|required). Operation up to 50% load permissible with sideways or front side up mounting orientation.<br>< 90% RH,noncondensing;IEC 60068-2-2,68-2-3<br>~~ae~~|||| |**Altitude**|0 to 3000 meters(0 to 10,000 feet)|||| |**Vibration**|2.5(g)RMS,10-2000 Hz(random);three axes for 20 minutes each - IEC 60068-2-6|||| |**Shock**<br>~~oo~~|3(g) peak,three axes,11mseconds for each axis - IEC 60068-2-27<br>~~oo~~|||| |**Warranty**<br>~~oo~~|5 Year Limited Warranty<br>~~oo~~|||| |**MTBF**<br>~~oo~~|>500,000 hrs MTBF(Nominal voltage, full load, Tamb= 25oC)<br>~~oo~~|||| |**General Protection/Safety**<br>~~a~~|Protected against short -circuit, overload, open circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529)<br>Safe low voltage: SELV (acc. EN60950)|||| |**Over-temperature protection**<br>~~a~~|Safe low voltage: SELV (acc. EN60950)<br>LED Alarm,Output shutdown with automatic restart|||| |**Status Indicators**|Visual: 3 status LEDs (Input, Output, Alarm) Relay: SSR or dry relay contact, signal active when Vout= 18.5 Vdc = +/-5%|||| |**Installation**||||| |**Fusing:-Input**|Externallyfused|||| |**-Output**|Not fused. Output is capable ofprovidinghigh currents(PowerBoost)for motor load startup.|||| |**Mounting**|Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.<br>Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail.|||| |**Connections9**<br>~~a ee~~|Input: screw terminals, Wiring for the connector will be Ground on the left (when looking at the front of the unit),<br>connector size range: 16-10AWG (1.5-6mm2) for solid conductors. Screw Torque: 4.4 lb-in (~ 50 N-cm). Output: connector size range, wire gauge<br>7-6 AWG (10.6-13 mm2) for solid conductors. Screw Torque: 15.6 lb-inch (~ 176 N-cm) for SDN40;<br>all other models: 16-10AWG (1.5-6mm2) for solid conductors. Screw Torque: 7 lb-inch (~80 N-cm)<br>~~ee~~|||| 4. Losses are heat dissipation in watts at full load, nominal line. 5. 24-28 Vdc adjustable guaranteed at full load. 6. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth 9. SDN 40-24-100C only = Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND). 10. 70% maximum rated load. Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 121 **3** Power Supplies A Oo gO ~~ooSOLA HD~~ ## SDN-C Series Dimensions **==> picture [523 x 522] intentionally omitted <==** **----- Start of picture text -----**<br> _ W ————— D<br>Dimensions - inches (mm)<br>Catalog<br>_ ff \ i Number<br>H W D<br>+ + - -<br>24 VDC / 2.5 A O 24OK - 28 V NEC Class 2Power SupplyOK |® SDN 5-24-100CSDN 10-24-100C 4.85 (123.0)4.85 (123.0) 1.97 (50.0)2.36 (60.0) 4.36 (111.0)4.36 (111.0)<br>Single<br>Parallel SDN 20-24-100C 4.85 (123.0) 3.42 (87.0) 4.98 (127.0)<br>+<br>S O L A °<br>SDN 5-24-480C 4.85 (123.0) 1.97 (50.0) 4.36 (111.0)<br>Power Supply SDN5-24 SDN 2.5 - - 24 10 - 0 100P C<br>SDN 10-24-480C 4.85 (123.0) 2.36 (60.0) 4.36 (111.0)<br>C UL US LISTED SDN 20-24-480CC 4.85 (123.0) 3.35 (85.0) 4.68 (119.0)<br>115/230 VAC 1.3 - 0.7 A 50/60 HZ<br>N L<br>eS (SKexe]) !LY t.<br>_] t—i(i‘_isSSJ<br>SDN 40-24-100C and SDN 40-24-480C Dimensions<br>W<br>D<br>seg ej 1<br>Power Supply<br>So 2 a |<br>—[eet Signal =i<br>Connector [1]<br>D + 0.54 in (13.80 mm)<br>Dimensions - inches (mm)<br>Catalog<br>Number<br>H W D<br>a<br>SDN 40-24-100C 4.85 (123.0) 7.09 (180.0) 4.66 (118.0)<br>SDN 40-24-480C 4.85 (123.0) 7.09 (180.0) 4.81 (122.0)<br>H<br>5.51 in. (139.96 mm) H<br>**----- End of picture text -----**<br> ## SDN 40-24-100C and SDN 40-24-480C Dimensions 1. SDN 40-24-100C and SDN 40-24-480C output signaling terminal block features: Shut Down, Power Good, Current Monitor, Current Balance, GND, and active current sharing through I_SHARE connectors (See Signals Manual for connection information). Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 122 **3** Power Supplies ## SDN-C Series Mounting ## Chassis Mounting Dimensional Diagram - in (mm) Instead of snapping a SolaHD SDN™ unit on the DIN Rail, you can also attach it using the screw mounting set SDN-PMBRK2. This set consists of two metal brackets, which replace the existing two aluminum profiles. **==> picture [504 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> 1.59<br>(40.4)<br>.70 (17.8) .60 (15.2)<br>.43 (10.9)<br>.23 (5.8) .51 (13.0)<br>yt .18 Apa — [elt El Ele<br>.86 (4.6)<br>(21.8)<br>2.16 (54.9)<br>.60 1.30 1.80<br>(15.2) (33.0) (45.7)<br>.35<br> Nm (8.9) © ary 2 fee i<br>.08 (2.0).23 (5.8) (10.2).40 an .26 (6.6) IT |) peopel<br>.25 (6.4)<br>.52 (13.2) .52 (13.2)<br>**----- End of picture text -----**<br> **==> picture [103 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Detachment from DIN Rail:<br>**----- End of picture text -----**<br> ## DIN Rail Mounting Snap on the DIN Rail: 1. Tilt unit slightly backwards 2. Put it onto the DIN Rail 3. Push downwards until stopped 4. Push at the lower front edge to lock 5. Shake the unit slightly to ensure that the retainer has locked Alternative Panel Mount: Using the optional SDN-PMBRK2 accessory, the unit can be screw mounted to a panel. Contact **Technical Services** at **(800) 377-4384** with any questions. Visit our website at www.solahd.com. 123
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →