- Manufacturer: SOLAHD
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:240W; Output Voltage - Output 1:24VDC; Output Current - Output 1:10A; Output Voltage - Output 2 56T8190
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 513.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
**4**
Power Supplies
## The SolaHD Difference
**==> picture [511 x 498] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rugged metal packaging<br>Multiple output connections for<br>ease of wiring multiple devices<br>4 SE<br>Large, IP20-rated, screw<br>terminals for #10 AWG/6 mm [2] ,<br>for quick, easy installation<br>New visual diagnostic LEDs show input and output status ||<br>(see table below) 1N * \<br>DC OK Relay<br>i]<br>i| ||q<br>Single or parallel use<br>| :<br>selectable by user<br>H Adjustable output voltage<br>f<br>Clearly labeled front panel<br>No internal fan, no extra cooling<br>required in any power level<br>UL508 listing means no |<br>derating in UL 508 systems<br>IND.CONT.EQ<br>c US LISTED<br>| 115/230V~—2.2/1.0A 50/60 HZ Full CE compliance for<br>Automatically adjusts for global | © ne safety, emissions and<br>Input voltages. No manual ingress protection<br>intervention required. | 1676) ©)<br>New narrow width<br>saves panel space<br>**----- End of picture text -----**<br>
## LED Light Status Conditions
||**Normal**|**AC Power Loss**|**AC Input Low**|**No DC**|**High Load**|**Overload**|**Hot**|**Too Hot**|
|---|---|---|---|---|---|---|---|---|
|**Input**|Green|-|Yellow|Green|Green|Green|Green|Green|
|**Output**|Green|-|Green|-|Yellow|Yellow|Green|-|
|**Alarm**|-|-|-|Red|Yellow|Red|Yellow|Yellow|
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**102**
**4** |
Power Supplies
## SDN-C Specifications (Single Phase)
|**Description**<br>~~Be~~<br>~~_~~<br>~~es~~|**Catalog Number**<br>~~—~~|**Catalog Number**<br>~~—~~|**Catalog Number**<br>~~—~~|
|---|---|---|---|
||**SDN 5-24-100C**<br>~~—~~|**SDN 10-24-100C**<br>~~—~~|**SDN 20-24-100C**<br>~~ere~~|
|**Input**<br>~~Be~~<br>~~_~~<br>~~—~~<br>~~—_—_—A—E_—--wwumuEee~~<br>~~ere~~<br>~~es~~||||
|**Nominal Voltage**<br>~~—_—_—A—E_—--wwumuEee~~<br>~~es~~|115/230 Vac<br>~~—_—_—A—E_—--wwumuEee~~<br>~~ere~~|||
|**-AC Range**<br>~~—_—_—A—E_—--wwumuEee~~<br>~~es~~<br>~~es~~|85 - 264 Vac<br>~~—_—_—A—E_—--wwumuEee~~<br>~~ere~~|||
|**-DC Range 1**<br>~~es~~<br>~~es~~<br>~~es~~|90 - 375 Vdc<br>~~ere~~|||
|**-Frequency**<br>~~es~~<br>~~es~~<br>~~a~~|43 - 67 Hz<br>~~Itn~~|||
|**Nominal Current2**<br>~~es~~<br>~~a~~<br>~~es~~|1.65 - 0.55 A<br>~~I~~|3.2 - 1.0 A<br>~~tn~~<br>~~777]~~|6 A / 3 A<br>~~-~~|
|**-Inrush current max.**<br>~~a~~<br>~~oT7,dJd—_~~<br>~~es~~|Typ. < 15 A<br>~~I ~~<br>~~oT7,dJd—_~~|Typ.< 30 A<br> ~~tn~~<br>~~oT7,dJd—_~~<br>~~777]~~|< 40 A<br>~~oT7,dJd—_~~<br>~~-~~|
|**Efficiency (Losses3)**<br>~~oT7,dJd—_~~<br>~~es~~|> 90% typ. (12 W)<br>~~oT7,dJd—_~~|> 90% typ. (24 W)<br>~~oT7,dJd—_~~<br>~~777]~~|> 92% (38 W)<br>~~oT7,dJd—_~~<br>~~-~~|
|**Power Factor Correction**<br>~~oT7,dJd—_~~<br>~~es~~<br>~~Dy~~|Active power factor correction to better than 0.92<br>~~oT7,dJd—_~~<br>~~777]~~<br>~~-~~<br>|||
|**Output**<br>~~777]~~<br>~~-~~<br>~~es~~<br>~~Dy~~||||
|**Nominal Voltage**<br>~~Dy~~|24 V (23.5~28.5 Vdc Adj.)<br>|||
|**-Tolerance**<br>~~Dya~~|< ±2 % overall (combination Line, load, time and temperature related changes)<br>~~a~~|||
|**Initial Voltage Setting**<br>~~a~~<br>~~ee~~|24.5 V ± 1%<br>~~a~~|||
|**-Ripple4**<br>~~a~~<br>~~ee~~|< 50 mVpp<br>~~a~~||<100 mVpp<br>~~a~~|
|**PARD**<br>~~ee~~|PARD (Periodic and Random Deviation) = 100 mV peak-peak max|||
|**Overvoltage Protection**<br>~~[oop~~|> 30.5 but < 33 Vdc, auto recovery<br>~~[oop~~|||
|**Power Back Immunity**<br>~~[oop~~<br>~~ny~~|< 35 V<br>~~[oop~~<br>~~Se~~|||
|**Nominal Current**<br>~~[oop~~<br>~~ny~~|5 A (120 W)<br>~~[oop~~<br>~~Se~~|10 A (240 W)<br>~~[oop~~|20 A (480 W)<br>~~[oop~~|
|**-Peak Current5**<br>~~ny~~|1.5 × Nominal Current for 2 seconds minimum while holding voltage > 20 Vdc<br>~~Se~~|||
|**-Short Circuit Current**<br>~~Oe~~|1.5 x Nominal Current at near zero volts at short circuit condition<br>~~Oe~~|||
|**-Current Limit**<br>~~Oe~~|PowerBoost™<br>~~Oe~~|||
|**Parallel Operation**<br>~~Oe~~<br>~~ee~~|Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting).<br>~~Oe~~<br>~~ee~~|||
|**Holdup Time**<br>~~ee~~|>20 ms (Full load, 100 Vac Input @ Tamb=+25°C) to 95% output voltage<br>~~ee~~|||
|**Voltage Fall Time**|<150 mS from 95% to 10% rated voltage @ full load (Tamb=+25°C)|||
|**Line and Load Regulation**<br>~~Cn~~|< 0.5%<br>|||
|**General**<br>~~Cn~~||||
|**EMC:**<br>**-Emissions**<br>~~Cna~~|EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2<br>~~a~~|||
|**-Immunity**<br>~~a~~|EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input<br>and level 3 output. EN61000-4-5 Isolation class 4,EN61000-4-11,IEC 61000-4-34 voltage dipimmunitystandard<br>~~a~~|||
|**Approvals**<br>~~a~~|cULus Listed UL508, CSA C22.2 No. 107.1; UL 60950-1/CSA C22.2 No.60950-1 2nd ed, ANSI/ISA 12.12.01, CSA C22.2<br>No. 213; Class I, Div. 2, Groups A,B,C and D, T4 in a 40oC ambient; CE IEC60950-1:2005 2nd ed, EN60950-1:2006+A11:2009;<br>Models SDN 5-24-100C and SDN 10-24-100C - UL60079-15/CSA C22.2 E60079-15 Class I, Zone 2 AEx nC IIC, Ex nC IIC,<br>60oC ambient and ATEX EN60079-0,EN60079-15 II 3 G Ex nC IICpending<br>~~a~~<br>~~&)~~|||
|**Temperature6**<br>~~a~~<br>~~es~~|Storage: -40oC to + 85oC, Operation -25oC to +60oC full power, with linear derating to half power from 60 to 70oC (Convection cooling,<br>no forced air required). Operation upto 50% loadpermissible with sideways or front side upmountingorientation.<br>~~a~~<br>~~&)~~<br>|||
|**MTBF 7**<br>~~es~~|> 550,000 hrs<br>||> 450,000 hrs<br>|
|**Warranty**<br>~~esee~~|5 Years<br>~~ee~~|||
|**General Protection/Safety**<br>~~ee~~|Protected against continuous short -circuit, continuous overload, continuous open circuit.<br>Protection Class 1(IEC536),degree ofprotection IP20(IEC60529)Safe low voltage: SELV(acc. IEC60950-1)<br>~~ee~~|||
|**Status Indicators**<br>~~ee~~<br>~~a~~|**Visual:**3 status LEDs (Input, Output, Alarm)<br>**Relay: **N.O. contact rated 200ma/50 Vdc<br>~~ee~~|||
|**Installation**<br>~~a~~<br>~~ne~~||||
|**Fusing -Input**<br>~~ne~~|Internallyfused|||
|**-Output**<br>~~ne~~<br>~~a~~|Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for<br>wire/loads if 2x Nominal O/P current ratingcannot be tolerated. Continuous current overload allows for reliable fuse tripping.|||
|**Mounting**<br>~~Sn~~|Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.<br>~~Sn~~|||
|**Connections**<br>~~a~~|**Input:**Screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors.<br>**Output:**Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors.|||
|**Case**<br>~~[po~~|Fully enclosed metal housing with fine ventilation grid to keep out small parts.<br>~~[po~~|||
|**-Free Space**<br>~~[po~~|15 mm in front, 25 ~ 40 mm above and below, 10 mm left and right.<br>~~[po~~|||
|**H x W x D inches(mm)**<br>~~i~~|4.85 × 1.97 × 4.36 (123 × 50 × 110)<br>~~i~~|4.85 × 2.36 × 4.36 (123 × 60 × 110)<br>~~i~~|4.85 x 3.42 x 4.98 (123 x 87 x 127)<br>~~i~~|
|**Weight lbs(kg)**<br>~~i~~|1.10 (0.5)<br>~~i~~|1.76 (0.8)<br>~~i~~|2.6 (1.2)<br>~~i~~|
3. Losses are heat dissipation in watts at full load, nominal input line.
6. Contact tech support for operation at -25[o] C.
7. Demonstrated through extended life test.
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
**103**
» **4**
Power Supplies
## SDN-C Specifications (Three Phase) **Description SDN 5** ~~—~~
|**Description**<br>~~—~~|**Catalog Number**<br>~~oe~~|**Catalog Number**<br>~~oe~~|**Catalog Number**<br>~~oe~~|**Catalog Number**<br>~~oe~~|
|---|---|---|---|---|
||**SDN 5-24-480C**|**SDN 10-24-480C**|**SDN 20-24-480CC**<br>~~oe~~|**SDN 40-24-480C**<br>~~oe~~|
|**Input**<br>~~—~~<br>~~oe~~|||||
|**Nominal Voltage**|380 - 480 Vac||||
|**Two- phase input**|Yes1||||
|**-AC Range2**|320 - 540 Vac||||
|**-DC Range**|450 - 760 Vdc|450 - 760 Vdc|450 - 760 Vdc9|N/A|
|**-Frequency**|50/60 Hz||||
|**Nominal Current3**|3 x 0.5 or 2 x 0.7 A|3 x 0.8 or 2 x 1.2 A|3 x 0.9 or 2 x 1.3 A|3 x 1.6 A|
|**-Inrush current max.**|Typ. <25 A||Negligible|Negligible|
|**Efficiency (Losses4)**|> 85%(18 W)|91.2%(23.6 W)|93%(42 W)|94%(78 W)|
|**Power Factor Correction**|Power factor correction to meet EN61000-3-2 Class A||Active Power Factor Correction||
|**Output**|||||
|**Turn on time**|**Output**<br>Typ. 1s||||
|**Voltage Rise Time**|ca. 5-20 ms||<100 ms full resistive load(Tamb=+25°C)||
|**Power Back Immunity**|<35 V||||
|**Overvoltage Protection**|>30.5 but <33 Vdc auto recovery||||
|**Nominal Voltage**|24 V(24 - 28 Vdc Adjustable)||||
|**Voltage Regulation**|< ±2 % overall||||
|**Initial Voltage Setting**|24.5 V ± 1%||||
|**-Ripple5**|<100 mVpp||||
|**PARD**<br>~~es~~|PARD = 100 mVpeak-peak max<br>~~I~~||PARD = 200 mVpeak-peak max<br>~~I~~||
|**Nominal Current**<br>~~es~~|5 A (120 W)<br>~~I~~|10 A (240 W)<br>~~I~~|20 A (480 W) (constant power,<br>not constant current)<br>~~I~~|40 A (960 W)<br>~~I~~|
|**-Peak Current6**<br>~~es~~|6A,2×Nominal Current <2sec<br>~~I~~|12A,2×Nominal Current <2sec<br>~~I~~|1.5×Nominal Current for 4 sec minimum while holdingvoltage > 20Vdc<br>~~I~~||
|**-Current Limit**|PowerBoost™||||
|**Derating**|typ. 6 W/oC|typ. 12 W/oC|typ. 24 W/oC|typ. 48 W/oC|
|**Holdup Time**|>20 ms|||>15 ms|
|**Voltage Fall Time**<br>~~es~~|<150 ms from 95% to 10% rated voltage @ full load(Tamb=+25°C)<br>~~ns~~||<50 ms from 95% to 10% rated voltage @ full load(T~~amb~~=+25°C)<br>~~ns~~||
|**Parallel Operation7**<br>~~es~~|Single or Parallel operation selectable via front switch. For redundant<br>operation, use of external diode module is preferred<br>~~ns~~|||~~amb~~<br>SDN 40 uses active paralelling<br>~~ns~~|
|**General**<br>~~esns~~|||||
|**Case**<br>~~is~~|Fullyenclosed metal housingwith fine ventilationgrid to keepout smallparts.<br>~~ss~~||||
|**Min. Required**<br>~~is~~|25mm above and below or<br>15mm in front<br>~~ss~~|25mm above and below or<br>10mm in front<br>~~ss~~|70mm above and below or<br>25mm in front and 25mm left &<br>right<br>~~ss~~|70mm above and below, 15mm in<br>front, 25mm left & right<br>~~ss~~|
|**Free Space**<br>~~is~~|||||
|**H×W×D inches (mm)**<br>~~is~~|4.85 × 1.97 × 4.36(123 × 50 × 111) <br>~~ss~~|4.85 × 2.36 × 4.36(123 × 60 × 111) <br>~~ss~~|4.85 x 3.35 x 4.68(123 x 85 x 119) <br>~~ss~~|4.85 x 7.09 x 4.66(123 x 180 x 119)<br>~~ss~~|
|**Weight lbs (kg)**<br>~~is~~|1.15(.52)<br>~~ss~~|1.54(0.7)<br>~~ss~~|2.86(1.3)<br>~~ss~~|5.28(2.4)<br>~~ss~~|
|**EMC:-Emissions**|EN61000-6-3:2001,Class B EN55011,EN55022 Radiated and Conducted includingAnnex. A,EN61000-3-2||||
|**-Immunity**|EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level<br>3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, Semi F47 sag immunity.||||
|**Approvals**|cULus Listed UL508, CSA C22.2 No. 107.1; UL 60950-1/CSA C22.2 No.60950-1 2nd ed; CE IEC60950-1:2005 2nd ed,<br>EN60950-1:2006+A11:2009; SDN 20-24-480C and SDN 40-24-480C - ANSI/ISA 12.12.01, CSA C22.2 No. 213; Class I, Div. 2, Groups<br>A,B,C and D, T4 in 60oC ambient; SDN 5-24-480C and SDN 10-24-480C - UL 60079-15/CSA C22.2 E60079-15 Class I, Zone 2 AEx nA<br>IIC, Ex nA IIC, T4 in 60oC ambient; ATEX: EN60079-0, EN60079-15 II 3 G Ex nC IIC Gc, T4 in 60oC ambient, DEMKO 11 ATEX 1057365U and<br>DEMKO 11 ATEX 1105449U**10**||||
|**Temperature**<br>~~fd~~|Storage : -40 to + 85oC, Operation -25 to +60oC full power, with linear derating to half power from 60 to 70oC (Convection cooling, no forced air<br>required). Operation up to 50% load permissible with sideways or front side up mounting orientation.<br>~~fd~~||||
|**Humidity**<br>~~fd~~|required). Operation up to 50% load permissible with sideways or front side up mounting orientation.<br>< 90% RH,noncondensing;IEC 60068-2-2,68-2-3<br>~~fd~~||||
|**Altitude**<br>~~fd~~|0 to 3000 meters(0 to 10,000 feet)<br>~~fd~~||||
|**Vibration**<br>~~—_~~|2.5(g)RMS,10-2000 Hz(random);three axes for 20 minutes each - IEC 60068-2-6||||
|**Shock**<br>~~—_~~|3(g) peak,three axes,11mseconds for each axis - IEC 60068-2-27||||
|**Warranty**<br>~~—_~~|5 Years||||
|**MTBF**<br>~~—_~~<br>~~jf~~|>500,000 hrs MTBF(Nominal voltage, full load, Tamb= 25oC)<br>~~jf~~||||
|**General Protection/Safety**<br>~~—_~~<br>~~jf~~|Protected against short -circuit, overload, open circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529)<br>Safe low voltage: SELV (acc. EN60950)<br>~~jf~~||||
|**Over-temperature protection**<br>~~jf~~|Safe low voltage: SELV (acc. EN60950)<br>LED Alarm,Output shutdown with automatic restart<br>~~jf~~||||
|**Status Indicators**<br>~~jf~~|Visual: 3 status LEDs (Input, Output, Alarm) Relay: SSR or dry relay contact, signal active when Vout= 18.5 Vdc = +/-5%<br>~~jf~~||||
|**Installation**|||||
|**Fusing:-Input**|Externallyfused||||
|**-Output**<br>~~ee~~|Not fused. Output is capable ofprovidinghigh currents(PowerBoost)for motor load startup.||||
|**Mounting**<br>~~ee~~|Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.<br>Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail.||||
|**Connections8**<br>~~ee~~<br>~~a~~|Input: screw terminals, Wiring for the connector will be Ground on the left (when looking at the front of the unit),<br>connector size range: 16-10AWG (1.5-6mm2) for solid conductors. Output: connector size range, wire gauge 6-7 AWG for SDN40;<br>all other models: 16-10AWG (1.5-6mm2) for solid conductors.||||
- [1. SDN 20 will operate at 75% load; SDN 40 will operate at 50% load under loss of 1 phase; SDN 5 ] and SDN 10 will operate with single phase input power at 100% of load. Unit will shut down if thermal threshold is exceeded under this condition.
6. SDN 20 and 40 unit will go to HICCUP mode. SDN 5 and 10 will maintain min 4 secs to deliver 150% load then drops to almost zero Vout. The output voltage will immediately drop to almost zero when load rises above 150%.
2. Unit passed input voltage overstress test at 600 Vac without failure.
7. All models except the 40amp unit are capable of parallel operation by use of a jumper pin, accessible by the end user. 40 amp unit will have active current sharing signal.
3. Input current ratings are specified with low input, line conditions, worst case efficiency values and power factor spikes. Input current at nominal input settings will typically be half these values.
8. SDN 40-24-480C only = Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND).
4. Losses are heat dissipation in watts at full load, nominal line.
5. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth scope and 50 Ohm resistor.
9. 70% maximum rated load.
10. Additional Installation requirements apply when used in hazardous locations. (refer to user manual)
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
**104**
**4**
Power Supplies
SDN-C Series Dimensions
**==> picture [176 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
-_ W > “t D<br>+ + - -<br>24 VDC / 2.5 A OK<br>° 24OK - 28 V NEC Class 2Power Supply | [<br>Single<br>Parallel<br>S O L A<br>Power Supply SDN5-24 SDN 2.5 - - 24 10 - 0 100P C<br>C UL US LISTED<br>115/230 VAC 1.3 - 0.7 A 50/60 HZ<br>OF(oxemey@ N L « c\\\\ |<br>H<br>**----- End of picture text -----**<br>
|**Catalog**<br>**Number**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|**SDN 5-24-100C**|4.85 (123)|1.97 (50)|4.36 (111)|
|**SDN 10-24-100C**<br>**SDN 20-24-100C**|4.85 (123)<br>4.85 (123)|2.36 (60)<br>3.42 (87)|4.36 (111)<br>4.98 (127)|
|**SDN 20-24-100C**<br>**SDN 5-24-480C**|4.85 (123)<br>4.85 (123)|3.42 (87)<br>1.97 (50)|4.98 (127)<br>4.36 (111)|
|**SDN 10-24-480C**|4.85 (123)|2.36 (60)|4.36 (111)|
|**Catalog**<br>**Number**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|**SDN 40-24-480C**|4.85 (123)|7.09 (180)|4.66 (118)|
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**105**
**4** Power Supplies ~~OLA~~ ~~**S** s~~
## SDN-C Series Mounting (cont.)
## Chassis Mounting
## Dimensions
Instead of snapping a SolaHD SDN™ unit on the DIN Rail, you can also attach it using the screw mounting set SDN-PMBRK2.
This set consists of two metal brackets, which replace the existing two aluminum profiles.
## SDN-C Series Mounting
## Detachment from DIN Rail:
## DIN Rail Mounting
Snap on the DIN Rail:
1. Tilt unit slightly backwards
2. Put it onto the DIN Rail
3. Push downwards until stopped
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer has locked
Alternative Panel Mount: Using the optional SDN-PMBRK2 accessory, the unit can be screw mounted to a panel.
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**106**
**Product Comparison Sheet SDN 5-24-480C to SDN 5-24-480**
## **The Next Generation of SDN Series Power Supplies**
## **SDN 5-24-480C**
SolaHD is proud to introduce the new SDN 5-24-480C power supplies, the next generation of our popular SDN5-24-480.
The new product has a significantly enhanced performance with a full **32** % smaller width along the DIN rail! Every effort has been made to ensure compatibility between generations. Still, we realize that even small differences can sometimes have unforeseen impact, so we have created this document to highlight all of these differences.
|**Input**<br>~~a~~|||
|---|---|---|
|**Nominal Voltage **<br>~~a~~|1phase or 3-phase 380 - 480 Vac<br>|Similar: 1phase or 3-phase 380 - 480 Vac<br>|
|**AC Range **<br>|320-540 Vac<br>|340-576 Vac<br>|
|**DC Range **<br>|450-760 Vdc<br>|450-820 Vdc<br>|
|**Frequency**<br>|50/60 Hz<br>|50/60 Hz<br>|
|**Nominal Current**<br>|3 x 0.5 or 2 x 0.7 A<br>|0.5 A<br>|
|**Inrush Current Max**<br>|Typ. < 25 A<br>|Typ. <18 A<br>|
|**Efficiency (Losses)**<br>~~ee~~|> 85%(18 W)<br>~~ee~~|>90%(12 W)<br>~~ee~~|
|**Power Factor**<br>**Correction**<br>~~ee~~|Power factor Correction to meet EN61000-3-2<br>ClassA<br>~~ee~~|SAME<br>~~ee~~|
|**Output**|||
|**Nominal Voltage **<br>~~a~~|24 V(24-28 VDC Adj.)<br>~~a~~|24 V(22.5 - 28.5 VDC Adj.)<br>~~a~~|
|**Initial voltage setting**<br>~~a~~<br>~~——~~|24.5 V ± 1%<br>~~a~~|SAME<br>~~a~~|
|**Tolerance**<br>~~——~~|< 2 % overall (combination Line, load, time and<br>temperature related changes)|SAME|
|**Line regulation**<br>~~——~~|< 0.5%|SAME|
|**Load regulation**<br>~~——~~|< 0.5%|SAME|
|**Over voltage**<br>**protection**<br>~~re~~|> 30.5 but < 33 Vdc, auto recovery<br>~~re~~|SAME<br>~~re~~|
|**Power Back Immunity**<br>~~re~~|< 35 V<br>~~re~~|SAME<br>~~re~~|
|**Time & temperature**<br>**drift**<br>~~le~~|< 1%<br>~~le~~|SAME<br>~~le~~|
|**Ripple**<br>~~le~~|< 50 mVpp<br>~~le~~|SAME<br>~~le~~|
|**Nominal Current**|5 A(120 W)|SAME|
|**Peak Current**<br>~~a~~|6A, 2 × Nominal Current <2sec|SAME|
|**Current Limit**<br>~~a ee~~|PowerBoost ™<br>~~ee~~|Fold Forward (Current rises, voltage drops to<br>maintain constant power during overload up to<br>maxpeak current)<br>~~ee~~|
EGS Electrical Group, LLC www.solahd.com
Page 1 of 3
2011 Emerson Industrial Automation
## **Product Comparison Sheet SDN 5-24-480C to SDN 5-24-480**
|**Holdup Time**|>20ms (Full load, 380Vac Input @ T ambient<br>+25°C) to 95% output Voltage|> 16 ms at Full load (+25°C)|
|---|---|---|
|**Voltage fall time**|< 150ms from 95% to 10% rated voltage @ full<br>load(T ambient =+25°C)|SAME|
|**Turn on time**|<1000mS after AC is applied to input at full<br>resistive load(Tambient =+25°C)|SAME|
|**Parallel Operation**|Single or Parallel operation selectable via front<br>switch. For redundant operation, use of<br>externaldiodemoduleis preferred.|SAME|
|**General**|||
|**Case**|Fully enclosed metal housing with fine<br>ventilation grid to keep out small parts.|SAME|
|**Max. Required Free**<br>**Space**<br>**H×W×D inches (mm)**|25 mm above and below or 15 mm in front<br>4.85 x 1.97 x 4.36 (123.3 x 50.0 x 110.8)|SAME<br>4.88 x 2.91 x 4.55 (124 x 73 x 116)|
|**Weight**|1.15 lb (520 g)|1.7 lbs. (730 g)|
|**Emissions**|EN61000-6-3:2001, Class B EN55011,<br>EN55022 Radiated and Conducted including<br>Annex. A, EN61000-3-2|SAME|
|**Immunity**|EN61000-6-1:2001, EN61000-6-2:2001,<br>EN61000-4-2 Level 4, EN61000-4-3 Level 3,<br>EN61000-4-6 Level 3, EN61000-4-4 Level 4<br>input and Level 3 output, EN61000-4-5<br>Isolation Class 4, EN61000-4-11, SEMI F47<br>Sag Immunity, EN61000-4-8, EN61000-4-34,<br>Transient protection according to VDE<br>0160/W2overentireloadrange|SAME|
|**Approvals**|cULus Listed: UL 508, CSA C22.2 No. 107.1; :<br>UL 60950-1/CSA C22.2 60950-1 2nd edition,<br>UL 60079-15 and CAN/CSA-E60079-15, Class<br>I, Zone 2, AEx nC IIC Gc, Ex nC IIC U<br>hazardous locations; CE: IEC60950-1:2005<br>2nd edition, EN60950-1:2006+A11:2009;<br>ATEX: II 3 G Ex nC IIC Gc, DEMKO 11<br>ATEX 1057365U; EN60079-0:2009, EN60079-<br>15:2010|SAME|
|**Temperature**|Storage : -40 to + 85 deg C, Operation -25 to<br>+60 deg C full power, with linear derating to<br>half power from 60 to 70 deg C (Convection<br>cooling, no forced air required). Operation up<br>to 50% load permissible with sideways or front<br>side upmounting orientation.|Storage : -25 to + 85 deg C, Operation -10 to<br>+60 deg C full power, with linear derating to<br>half power from 60 to 70 deg C (Convection<br>cooling, no forced air required). Operation up<br>to 50% load permissible with sideways or front<br>side upmounting orientation.|
|**Humidity**|< 90% RH, non-condensing; IEC 68-2-2, 68-2-<br>3|SAME|
|**Altitude**|0 to 3000meters (0 to10,000feet)|SAME|
|**Vibration**|2.5(g) RMS, 10-2000 Hz (random); three axes<br>for 20 minutes each - IEC 60068-2-6|SAME|
2011 Emerson Industrial Automation EGS Electrical Group, LLC Page 2 of 3 www.solahd.com
## **Product Comparison Sheet SDN 5-24-480C to SDN 5-24-480**
||**Product Comparison Sheet**<br> **SDN 5-24-480C to SDN 5-24-480**|**Product Comparison Sheet**<br>**SDN 5-24-480C to SDN 5-24-480**|
|---|---|---|
|**Shock**|3(g) peak, three axes, 11mseconds for each<br>axis - IEC 60068-2-27|SAME|
|**Warranty**|5 Years|SAME|
|**MTBF**|>500,000 hrs DMTBF (Nominal voltage, full<br>load, T ambient = 25 degrees C|No DMTBF figure, only calculated MTBF|
|**General**<br>**Protection/Safety**|Protected against short -circuit, overload, open<br>circuit. Protection class 1 (IEC536), degree of<br>protection IP20 (IEC 529) Safe low voltage:<br>SELV(acc. EN60950)|SAME|
|**Status Indicators -**<br>**Visual**|3 status LEDs: Green LED when input voltage<br>is in range and green LED on when V out =<br>18.5V+/-5%. Red alarm LED|Green LED on when Vout = 18V or greater|
|**-Relay**|SSR or dry relay contact, signal active when<br>Vout= 18.5Vdc=+/-5%|SAME|
|**Installation**|||
|**Input Fusing**|Externallyfused.|InternallyFused|
|**Output Fusing**|Not fused. Output is capable of providing high<br>currents (PowerBoost) for motor load startup.|SAME|
|**Mounting**|Simple snap-on to DIN TS35/7.5 or TS35/15<br>rail system. Unit should handle normal shock<br>and vibration of industrial use and<br>transportation withoutfalling offtherail.|SAME|
|**Connections**|Input: screw terminals, wiring for the<br>connector will be Ground on the left<br>(when looking at the front of the unit),<br>connector size range: 16-10 AWG (1.5-<br>6mm2)forsolid conductors.|SAME|
||Output: connector size range, wire gauge 16-<br>10 AWG (1.5-6 mm2) for solid conductors. The<br>connector color will be either gray or off-white.|SAME|
EGS Electrical Group, LLC
Page 3 of 3
2011 Emerson Industrial Automation
www.solahd.com
##
## **Comparison with 5A, 24Vdc, 3-phase slim models**
||SolaHD<br>**SDN 5-24-480C**|PULS<br>(Two-Phase Input)<br>**CT5.241**|Phoenix Contact<br>**QUINT-**<br>**PS/3AC/24DC/5**|AB/Rockwell<br>(Two-Phase Input)<br>**1606-XLE120E-2**|
|---|---|---|---|---|
|**DIAGNOSTICS**<br>(number of conditions)|**8**<br>(Normal, AC Power Loss,<br>AC Input Low, No DC,<br>High Load, Overload, Hot,<br>Too Hot)|**2**<br>(DC ON, DC OFF)|**4**<br>(IOUT<IN, IOUT>IN,<br>VOUT<0.9xVN, VOUT>0.9xVN)|**2**<br>(DC ON, DC OFF)|
|**EFFICIENCY**|**>85% typ.**|**>90.4% typ.**|**>89%**|**90 % typ.**|
|**Mains Frequency**|**50-60 Hz**|**50-60 Hz**|**50-60 Hz**|**50-60 Hz**|
|**RELIABILITY**(MTBF)|**>500,000 hrs**<br>(Nominal Voltage,<br>Full load, 25°C Ambient)|**>1,173 khrs**<br>(40°C, SN 29500)|**> 500,000 hrs**<br>in acc. with IEC 61709<br>(SN29500)|**1,173,000 hrs**<br>SN 29500, IEC 61709<br>(24 V, 5 A and 40°C)|
|**Size**(cm3)|**682**|**580**|**650**|**580**|
|**Width along the DIN rail**<br>inch (mm)|**1.97 (50)**|**1.57 (40)**|**1.57 (40)**|**1.57 (40)**|
|**FULL POWER AMBIENT**|**-25 to 60°C**|**-25 to 60°C**|**-25 to 60°C**|**-25 to 60°C**|
|**WARRANTY**|**5 years**|**3 years**|**5 years**|**1 year**|
www.solahd.com solahd.technicalservices@emerson.com
**800-377-4384**
## **SDN 5-24-480C Competitive Comparison**
## **Comparison with 5A, 24Vdc, 3-phase regular (non-slim) models**
||SolaHD<br>(Compact)<br>**SDN 5-24-480C**<br>~~pf~~|SolaHD<br>(Non-Compact)<br>**SDN 5-24-480**<br>~~pfft}~~|PULS<br>**SL5.300**<br>~~ft}~~|Lambda<br>**DPP-120-24-3**<br>~~ft}~~|Phoenix Contact<br>**TRIO-**<br>**PS/3AC/24DC/5**<br>~~ft}tt~~|Mean well<br>(Two-Phase Input)<br>**DRH-120-24**<br>~~tt~~|AB/Rockwell<br>**1606-**<br>**XL120E-3**<br>~~tt~~|
|---|---|---|---|---|---|---|---|
|**DIAGNOSTICS**<br>(number of<br>conditions)<br>~~-—_{—_f|~~|**8**<br>(Normal, AC Power<br>Loss, AC Input Low,<br>No DC, High Load,<br>Overload, Hot,<br>Too Hot)<br>~~pf~~<br>~~-—_{—_f|~~|**2**<br>(DC ON, DC OFF)<br>~~pfft}~~<br>~~-—_{—_f|~~|**2**<br>(DC ON,<br>DC OFF)<br>~~ft}~~<br>~~-—_{—_f|~~<br>~~|~~|**3**<br>(DC ON, DC OFF,<br>DC Output Low)<br>~~ft}~~<br>~~_}~~|**2**<br>(DC ON, DC OFF)<br>~~ft}tt~~<br>~~_}_{~~|**2**<br>(DC ON, DC OFF)<br>~~tt~~<br>~~_{|~~|**2**<br>(DC ON, DC OFF)<br>~~tt~~<br>~~__~~|
|**EFFICIENCY**<br>~~-—_{—_f|~~|**>85% typ.**<br>~~pf~~<br>~~-—_{—_f|~~|**>90% typ.**<br>~~pf ft}~~<br>~~-—_{—_f|~~|**89% typ.**<br>~~ft}~~<br>~~-—_{—_f|~~<br>~~|~~|**84-93%**<br>~~ft}~~<br>~~_}~~|**>89%**<br>~~ft} tt~~<br>~~_}_{~~|**85% typ.**<br>~~tt~~<br>~~_{|~~|**89% typ.**<br>~~tt~~<br>~~__~~|
|**Mains**<br>**Frequency**<br>~~-—_{—_f|~~|**50-60 Hz**<br>~~-—_{—_f|~~<br>~~pf~~|**50-60 Hz**<br>~~-—_{—_f|~~<br>~~pfff~~|**50-60 Hz**<br>~~-—_{—_f|~~<br>~~|~~<br>~~ff~~|**50-60 Hz**<br>~~_}~~<br>~~ffft~~|**50-60 Hz**<br>~~_}_{~~<br>~~ft~~|**50-60 Hz**<br>~~_{|~~<br>|**50-60 Hz**<br>~~__~~<br>|
|**RELIABILITY**<br>(MTBF)<br>~~-—_{—_f|~~|**>500,000hrs**<br>(Nominal Voltage,<br>Full load, 25°C<br>Ambient)<br>~~-—_{—_f|~~<br>~~pf~~|**>1,110,000hrs**<br>(MIL STD 217F,<br>30°C Ambient)<br>~~-—_{—_f|~~<br>~~pfff~~|**410,000hrs**<br>(24V/5A, 3 AC<br>400V, 40°C<br>ambient)<br>~~-—_{—_f|~~<br>~~| ~~<br>~~ff~~|**527,000hrs**<br>(Bellcore Issue 6 @<br>40°C, GB)<br> ~~_}~~<br>~~ffft~~|**> 500,000 hrs**<br>(in acc. with IEC 61709<br>SN29500)<br>~~_} _{~~<br>~~ftff~~|**178.7 khrs**<br>(MIL-HDBK-217F,<br>25°C)<br>~~_{ | ~~<br>~~ff~~|**410,000 hrs**<br>acc. to<br>Siemensnorm<br>29500 (24V/5A,<br>400Vac, 40°C)<br> ~~__~~<br>~~ff~~|
|**Size**(cm3)|**682**<br>~~pf~~<br>~~a~~|**1,050**<br>~~pf ff~~<br>~~a~~|**1,059**<br>~~ff~~<br>~~a~~|**1,093**<br>~~ff ft~~<br>~~a~~|**598**<br>~~ft~~<br>~~a~~|**820**<br><br>~~a~~|**1,059**<br><br>~~a~~|
|**Width along**<br>**the DIN rail**<br>inch(mm)|**1.97 (50)**<br>~~a~~|**2.91 (73)**<br>~~a~~|**2.91 (73)**<br>~~a~~|**2.92 (74.17)**<br>~~a~~|**1.57 (40)**<br>~~a~~|**2.58 (65.5)**<br>~~a~~|**2.87 (73)**<br>~~a~~|
|**FULL POWER**<br>**AMBIENT**|**-25 to 60°C**<br>~~a~~|**-10 to 60°C**<br>~~a~~|**-10 to 60°C**<br>~~a~~|**-25 to 60°C**<br>~~a~~|**-25 to 55°C**<br>~~a~~|**-20 to 60°C**<br>~~a~~|**-25 to 60°C**<br>~~a~~|
|**WARRANTY**|**5 years**<br>~~a~~<br>~~rrr~~|**5 years**<br>~~a~~<br>~~rrr~~|**3 years**<br>~~a~~<br>~~rrr~~|**2 years**<br>~~a~~<br>~~rrr~~|**5 years**<br>~~a~~<br>~~rrr~~|**3 years**<br>~~a~~<br>~~rrr~~|**1 year**<br>~~a~~<br>~~rrr~~|
www.solahd.com solahd.technicalservices@emerson.com
**800-377-4384**
**Product Comparison Sheet SDN 10-24-480C to SDN 10-24-480**
## **The Next Generation of SDN Series Power Supplies**
## **SDN 10-24-480C**
SolaHD is proud to introduce the new SDN 10-24-480C power supplies, the next generation of our popular SDN 10-24-480.
The new product has a significantly enhanced performance with a full **32** % smaller width along the DIN rail! Every effort has been made to ensure compatibility between generations. Still, we realize that even small differences can sometimes have unforeseen impact, so we have created this document to highlight all of these differences.
|**Input**<br>~~a~~|||
|---|---|---|
|**Nominal Voltage **<br>~~a~~|1phase or 3-phase 380 - 480 Vac<br>|Similar: 1phase or 3-phase 380 - 480 Vac<br>|
|**AC Range **<br>|320-540 Vac<br>|340-576 Vac<br>|
|**DC Range **<br>|450-760 Vdc<br>|450-820 Vdc<br>|
|**Frequency**<br>|50/60 Hz<br>|50/60 Hz<br>|
|**Nominal Current**<br>|3 x 0.8 or 2 x 1.2 A<br>|0.8 A<br>|
|**Inrush Current Max**<br>|Typ. < 25 A<br>|Typ. <18 A<br>|
|**Efficiency (Losses)**<br>~~ee~~|> 91.2%(23.6 W)<br>~~ee~~|>90%(48 W)<br>~~ee~~|
|**Power Factor**<br>**Correction**<br>~~ee~~|Power factor Correction to meet EN61000-3-2<br>ClassA<br>~~ee~~|SAME<br>~~ee~~|
|**Output**|||
|**Nominal Voltage **<br>~~a~~|24 V(24-28 VDC Adj.)<br>~~a~~|24 V(22.5 - 28.5 VDC Adj.)<br>~~a~~|
|**Initial voltage setting**<br>~~a~~<br>~~——~~|24.5 V ± 1%<br>~~a~~|SAME<br>~~a~~|
|**Tolerance**<br>~~——~~|< 2 % overall (combination Line, load, time and<br>temperature related changes)|SAME|
|**Line regulation**<br>~~——~~|< 0.5%|SAME|
|**Load regulation**<br>~~——~~|< 0.5%|SAME|
|**Over voltage**<br>**protection**<br>~~re~~|> 30.5 but < 33 Vdc, auto recovery<br>~~re~~|SAME<br>~~re~~|
|**Power Back Immunity**<br>~~re~~|< 35 V<br>~~re~~|SAME<br>~~re~~|
|**Time & temperature**<br>**drift**<br>~~le~~|< 1%<br>~~le~~|SAME<br>~~le~~|
|**Ripple**<br>~~le~~|< 50 mVpp<br>~~le~~|SAME<br>~~le~~|
|**Nominal Current**|10 A(240 W)|SAME|
|**Peak Current**<br>~~a~~|12A, 2 × Nominal Current <2sec|SAME|
|**Current Limit**<br>~~a ee~~|PowerBoost ™<br>~~ee~~|Fold Forward (Current rises, voltage drops to<br>maintain constant power during overload up to<br>maxpeak current)<br>~~ee~~|
EGS Electrical Group, LLC www.solahd.com
Page 1 of 3
2011 Emerson Industrial Automation
## **Product Comparison Sheet SDN 10-24-480C to SDN 10-24-480**
|**Holdup Time**|>20ms (Full load, 380Vac Input @ T ambient<br>+25°C) to 95% output Voltage|> 24 ms at Full load (+25°C)|
|---|---|---|
|**Voltage fall time**|< 150ms from 95% to 10% rated voltage @ full<br>load(T ambient =+25°C)|SAME|
|**Turn on time**|<1000mS after AC is applied to input at full<br>resistive load(Tambient =+25°C)|SAME|
|**Parallel Operation**|Single or Parallel operation selectable via front<br>switch. For redundant operation, use of<br>externaldiodemoduleis preferred.|SAME|
|**General**|||
|**Case**|Fully enclosed metal housing with fine<br>ventilation grid to keep out small parts.|SAME|
|**Max. Required Free**<br>**Space**<br>**H×W×D inches (mm)**|25 mm above and below or 10 mm in front<br>4.85 x 2.36 x 4.36 (123.3 x 60.0 x 110.8)|25 mm above and below or 15 mm in front<br>4.88 x 3.5 x 4.55 (124 x 89 x 116)|
|**Weight**|1.54 lb (700 g)|2.16 lbs. (980 g)|
|**Emissions**|EN61000-6-3:2001, Class B EN55011,<br>EN55022 Radiated and Conducted including<br>Annex. A, EN61000-3-2|SAME|
|**Immunity**|EN61000-6-1:2001, EN61000-6-2:2001,<br>EN61000-4-2 Level 4, EN61000-4-3 Level 3,<br>EN61000-4-6 Level 3, EN61000-4-4 Level 4<br>input and Level 3 output, EN61000-4-5<br>Isolation Class 4, EN61000-4-11, SEMI F47<br>Sag Immunity, EN61000-4-8, EN61000-4-34,<br>Transient protection according to VDE<br>0160/W2overentireloadrange|SAME|
|**Approvals**|cULus Listed: UL 508, CSA C22.2 No. 107.1; :<br>UL 60950-1/CSA C22.2 60950-1 2nd edition,<br>UL 60079-15 and CAN/CSA-E60079-15, Class<br>I, Zone 2, AEx nC IIC Gc, Ex nC IIC U<br>hazardous locations; CE: IEC60950-1:2005<br>2nd edition, EN60950-1:2006+A11:2009;<br>ATEX: II 3 G Ex nC IIC Gc, DEMKO 11<br>ATEX 1057365U; EN60079-0:2009, EN60079-<br>15:2010|SAME|
|**Temperature**|Storage : -40 to + 85 deg C, Operation -25 to<br>+60 deg C full power, with linear derating to<br>half power from 60 to 70 deg C (Convection<br>cooling, no forced air required). Operation up<br>to 50% load permissible with sideways or front<br>side upmounting orientation.|Storage : -25 to + 85 deg C, Operation -10 to<br>+60 deg C full power, with linear derating to<br>half power from 60 to 70 deg C (Convection<br>cooling, no forced air required). Operation up<br>to 50% load permissible with sideways or front<br>side upmounting orientation.|
|**Humidity**|< 90% RH,noncondensing;IEC 68-2-2,68-2-3|SAME|
|**Altitude**|0 to 3000meters (0 to10,000feet)|SAME|
|**Vibration**|2.5(g) RMS, 10-2000 Hz (random); three axes<br>for 20 minutes each - IEC 60068-2-6|SAME|
EGS Electrical Group, LLC
Page 2 of 3
2011 Emerson Industrial Automation
www.solahd.com
## **Product Comparison Sheet SDN 10-24-480C to SDN 10-24-480**
||**Product Comparison Sheet**<br> **SDN 10-24-480C to SDN 10-24-480**|**Product Comparison Sheet**<br>**SDN 10-24-480C to SDN 10-24-480**|
|---|---|---|
|**Shock**|3(g) peak, three axes, 11mseconds for each<br>axis - IEC 60068-2-27|SAME|
|**Warranty**|5 Years|SAME|
|**MTBF**|>500,000 hrs DMTBF (Nominal voltage, full<br>load, T ambient = 25 degrees C|No DMTBF figure, only calculated MTBF|
|**General**<br>**Protection/Safety**|Protected against short -circuit, overload, open<br>circuit. Protection class 1 (IEC536), degree of<br>protection IP20 (IEC 529) Safe low voltage:<br>SELV(acc. EN60950)|SAME|
|**Status Indicators -**<br>**Visual**|3 status LEDs: Green LED when input voltage<br>is in range and green LED on when V out =<br>18.5V+/-5%. Red alarm LED|Green LED on when Vout = 18V or greater|
|**-Relay**|SSR or dry relay contact, signal active when<br>Vout= 18.5Vdc=+/-5%|SAME|
|**Installation**|||
|**Input Fusing**|Externallyfused.|InternallyFused|
|**Output Fusing**|Not fused. Output is capable of providing high<br>currents (PowerBoost) for motor load startup.|SAME|
|**Mounting**|Simple snap-on to DIN TS35/7.5 or TS35/15<br>rail system. Unit should handle normal shock<br>and vibration of industrial use and<br>transportation withoutfalling offtherail.|SAME|
|**Connections**|Input: screw terminals, wiring for the<br>connector will be Ground on the left<br>(when looking at the front of the unit),<br>connector size range: 16-10 AWG (1.5-<br>6mm2)forsolid conductors.|SAME|
||Output: connector size range, wire gauge 16-<br>10 AWG (1.5-6 mm2) for solid conductors. The<br>connector color will be either gray or off-white.|SAME|
EGS Electrical Group, LLC
Page 3 of 3
2011 Emerson Industrial Automation
www.solahd.com
## **SDN 10-24-480C Competitive Comparison**
## **Comparison with 10A, 24Vdc, 3-phase slim models**
||SolaHD<br>**SDN 10-24-480C**|PULS<br>**CT10.241**|Phoenix Contact<br>**QUINT-**<br>**PS/3AC/24DC/10**|AB/Rockwell<br>**1606-XLE240E-3**|
|---|---|---|---|---|
|**DIAGNOSTICS**<br>(number of conditions)|**8**<br>(Normal, AC Power Loss,<br>AC Input Low, No DC,<br>High Load, Overload, Hot,<br>Too Hot)|**2**<br>(DC ON, DC OFF)|**4**<br>(IOUT<IN, IOUT>IN,<br>VOUT<0.9xVN, <br>VOUT>0.9xVN)|**2**<br>(DC ON, DC OFF)|
|**EFFICIENCY**|**>91.2% typ.**|**>92.8% typ.**|**>93% typ.**|**92.9% typ.**|
|**Mains Frequency**|**50-60Hz**|**50-60Hz**|**50-60Hz**|**50-60Hz**|
|**RELIABILITY**(MTBF)|**>500,000 hrs**<br>(Nominal Voltage,<br>Full load, 25°C Ambient)|**>975,000 hrs**<br>(SN 29500, IEC 61709,<br>40°C Ambient)|**> 500,000 hrs**<br>in acc. with IEC 61709<br>(SN29500)|**> 700,000 hrs**<br>(Siemens norm SN29500 @<br>full load current, 40°C<br>Ambient)|
|**Size**(cm3)|**819**|**899**|**975**|**899**|
|**Width along the DIN rail**<br>inch (mm)|**2.36 (60)**|**2.44 (62)**|**2.36 (60)**|**2.44 (62)**|
|**FULL POWER AMBIENT**|**-25 to 60°C**|**-25 to 60°C**|**-25 to 60°C**|**-25 to 60°C**|
|**WARRANTY**|**5 years**|**3 years**|**5 years**|**1 year**|
www.solahd.com solahd.technicalservices@emerson.com
**800-377-4384**
## **SDN 10-24-480C Competitive Comparison**
## **Comparison with 10A, 24Vdc, 3-phase regular (non-slim) models**
||SolaHD<br>(Compact)<br>**SDN 10-24-480C**<br>~~pot~~|SolaHD<br>(Non-Compact)<br>**SDN 10-24-480**<br>~~pot~~<br>~~|~~|PULS<br>**SL10.300**|Lambda<br>**DPP-240-24-3**|Phoenix Contact<br>**TRIO-**<br>**PS/3AC/24DC/10**|Mean well<br>**DRT-240-24**|AB/Rockwell<br>**1606-**<br>**XL240E-3**|
|---|---|---|---|---|---|---|---|
|**DIAGNOSTICS**<br>(number of<br>conditions)|**8**<br>(Normal, AC Power<br>Loss, AC Input Low, No<br>DC, High Load,<br>Overload, Hot,<br>Too Hot)<br>~~pot~~|**2**<br>(DC ON, DC OFF)<br>~~pot~~<br>~~|~~|**2**<br>(DC ON,<br>DC OFF)|**3**<br>(DC ON, DC OFF,<br>DC Output Low)|**2**<br>(DC ON, DC OFF)|**2**<br>(DC ON, DC OFF)|**3**<br>(DC ON, DC OFF,<br>Overload)|
|**EFFICIENCY**|**>91.2% typ.**<br>~~pot~~<br>~~a~~|**>90% typ.**<br>~~pot~~<br>~~|~~<br>~~a~~|**91.2% typ.**<br>~~a~~|**90%**<br>~~a~~|**>89%**<br>~~a~~|**89% typ.**<br>~~a~~|**91.2% typ.**<br>~~a~~|
|**Mains**<br>**Frequency**|**50-60Hz**<br>~~a~~<br>~~a~~<br>~~pot~~|**50-60Hz**<br>~~a~~<br>~~a~~<br>~~pot~~<br>~~|~~|**50-60 Hz**<br>~~a~~<br>~~a~~<br>~~tT~~|**50-60Hz**<br>~~a~~<br>~~a~~<br>~~tT~~|**50-60 Hz**<br>~~a~~<br>~~a~~|**50-60Hz**<br>~~a~~<br>~~a~~|**50-60Hz**<br>~~a~~<br>~~a~~|
|**RELIABILITY**<br>(MTBF)|**>500,000 hrs**<br>(Nominal Voltage,<br>Full load, 25°C<br>Ambient)<br>~~pot~~|**>940,000 hrs**<br>(MIL STD 217F, 30°C<br>Ambient)<br>~~pot~~<br>~~|~~|**543,000 hrs**<br>(24V/10A, 3 AC<br>400V, 40°C<br>Ambient)<br>~~tT~~|**488,000**<br>(Bellcore Issue 6 @<br>40°C, GB)<br>~~tT~~|**> 500,000 hrs**<br>in acc. with IEC 61709<br>(SN29500)|**114.6 khrs**<br>(MIL-HDBK-<br>217F, 25°C)|**543,000 hrs**<br>acc. to<br>Siemensnorm<br>29500 (24V/10A,<br>400Vac, 40°C)|
|**Size**(cm3)<br>~~pot~~|**819**<br>~~pot~~<br>~~a~~<br>~~pot~~|**1,280**<br>~~pot~~<br>~~|~~<br>~~a~~<br>~~pot~~<br>~~|~~|**1,291**<br>~~tT~~<br>~~a~~|**1,309**<br>~~tT~~<br>~~a~~|**1,189.5**<br>~~a~~|**1,571**<br>~~a~~|**1,291**<br>~~a~~|
|**Width along**<br>**the DIN rail**<br>inch (mm)<br>~~pot~~|**2.36 (60)**<br>~~pot~~|**3.50 (89)**<br>~~pot~~<br>~~|~~|**3.50 (89)**|**3.50 (89)**|**2.36 (60)**|**4.94**<br>**(125.5)**|**3.50 (89)**|
|**FULL POWER**<br>**AMBIENT**<br>~~pot~~|**-25 to 60°C**<br>~~pot~~<br>~~a~~|**-10 to 60°C**<br>~~pot~~<br>~~|~~<br>~~a~~|**0 to 60°C**<br>~~a~~|**-25 to 60°C**<br>~~a~~|**-25 to 55°C**<br>~~a~~|**-20 to 60°C**<br>~~a~~|**-25 to 60°C**<br>~~a~~|
|**WARRANTY**|**5 years**<br>~~a~~|**5 years**<br>~~a~~<br>~~ee~~|**3 years**<br>~~a~~<br>~~ee~~|**2 years**<br>~~a~~<br>~~ee~~|**5 years**<br>~~a~~<br>~~ee~~|**3 years**<br>~~a~~<br>~~ee~~|**1 year**<br>~~a~~<br>~~ee~~|
www.solahd.com solahd.technicalservices@emerson.com
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →