Image not available
Illustrative purposes only
SDN10-24-100P
AC-DC CONVERTER, DIN RAIL, 1 O/P, 240W, 10A, 24V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SOLAHD
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:240W; Output Voltage - Output 1:24VDC; Output Current - Output 1:10A; Output 80K9315
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 574.08 € |
| Current stock | 200+ |
| Lead time | 30 days |
~~a00FCCCCCC_SSOLAHHD~~ SDN-P DIN Rail Series **4** Power Supplies
## SDN-P DIN Rail Series
The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications. Power factor correction to meet European directives, hazardous location approvals and optional redundant accessories allow the SDN series to be used in a wide variety of applications. Wide operation temperature range, high tolerance to shock and vibration and reliable design make the SDN series the preferred choice of users everywhere.
## Features
- Power Factor Correction (per EN61000-3-2)
- Auto Select 115/230 Vac, 50/60 Hz Input
**==> picture [140 x 46] intentionally omitted <==**
**----- Start of picture text -----**<br>
cUL)us WA us C€<br>UL 508 Listed UL 60950 EMC and<br>IND. CONT. EQ. E137632 Low Volt.<br>E61379 CUL/CSA-C22.2 Directive<br>No. 234-M90<br>**----- End of picture text -----**<br>
- Single Phase models meet SEMI F47 Sag Immunity
- Class 1, Zone 2 Hazardous Locations
- ATEX approval on 2.5 through 10A, 24 Vdc Single Phase Models
- ATEX approval pending on 12 Vdc and 48 Vdc single phase models
- Improved metal mounting clip
- DC OK Signal
## Related Products
- SDP™ Series
- SFL Series
- SCP Series
- SCL Series
- SDU UPS
- Adjustable Voltage
- SDN10-24-100P New Compact width (3.26”)
- Parallel Capability standard on all units
- Industrial grade design
- -10°C to 60°C operation without derating. Indefinite short circuit, overvoltage and
- overtemperature protection.
- Powers high inrush loads without shutdown or foldback
- Rugged metal case and DIN connector
- SDN2.5-24-100P and SDN4-24-100LP meet NEC Class 2
- Narrow width on rail for space critical applications
## Applications
- Industrial/Machine Control
- Process Control
- Conveying Equipment
- Material Handling
- Vending Machines
- Packaging Equipment
- DeviceNet[TM]
- Amusement Park Equipment
- Semiconductor Fabrication Equipment
- User-friendly front panel
- Large, rugged, accessible, multiple connection screw terminations
- – Easy installation
## Accessories
- Chassis Mount Bracket (SDN-PMBRK2)
- Broad range of product to fit almost any application – 2.5 A through 40 A, 24 Vdc
- Single and three phase inputs available
- 12 Vdc and 48 Vdc single phase models available
- Highly efficient >90% switching technology
- High MTBF and reliability
- RoHS compliant
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**106**
**4** |
Power Supplies
## SDN-P Specifications (Single Phase), 24 Vdc Output
DEMK0 06 ATEX 05 21715U
|**Description**<br>~~eee~~|**Catalog Number**<br>~~eee~~<br>~~SSS~~|**Catalog Number**<br>~~eee~~<br>~~SSS~~|**Catalog Number**<br>~~eee~~<br>~~SSS~~|**Catalog Number**<br>~~eee~~<br>~~SSS~~|**Catalog Number**<br>~~eee~~<br>~~SSS~~|
|---|---|---|---|---|---|
||**SDN 2.5-24-100P**<br>~~eee~~|**SDN 4-24-100LP**<br>~~eee~~|**SDN 5-24-100P**|**SDN 10-24-100P**<br>~~SSS~~|**SDN 20-24-100P**<br>~~SSS~~|
|**Input**<br>~~eee~~<br>~~SSS~~<br>~~es~~||||||
|**Nominal Voltage**<br>~~es~~<br>~~es~~|115/230 Vac auto select|||||
|**-AC Range**<br>~~es~~<br>~~es~~<br>~~es~~|85-132/176-264 Vac<br>~~nsnr~~|||||
|**-DC Range1**<br>~~es~~<br>~~es~~|90-375 Vdc<br>~~ns~~|210-375 Vdc<br>~~nr~~|||N/A<br>~~nr~~|
|**-Frequency**<br>~~es~~<br>~~es~~|47 - 63 Hz<br>~~nsnr~~<br>~~I~~|||||
|**Nominal Current2**<br>~~es~~<br>~~es~~|1.3 A. / 0.7 A<br>~~I~~<br>~~en~~|2.1 A / 1.0 A<br>~~I~~|2.2 A / 1.0 A|5 A / 2 A typ.|9 A/ 3.9 A|
|**-Inrush current max.**<br>~~es~~<br>~~es~~<br>~~es~~|typ. < 25 A<br>~~I~~<br>~~en~~<br>~~rn~~|typ. < 20 A<br>~~I~~||typ. < 40 A||
|**Efficiency (Losses3)**<br>~~es ~~<br>~~es~~<br>~~es~~|> 87.5% typ. (8.6 W)<br> ~~en~~<br>~~rn~~|> 88% typ. (13.1 W)|> 88% typ. (16.4 W)|> 88% typ. (32.7 W)|> 90% typ. (48 W)|
|**Power Factor Correction**<br>~~es~~<br>~~es~~<br>~~ey~~|Units Fulfill EN61000-3-2<br>~~rn~~|||||
|**Output**<br>~~es~~<br>~~ey~~||||||
|**Nominal Voltage**<br>~~ey~~|24 Vdc<br>(22.5 - 28.5 Vdc adj.)|24 Vdc<br>(22.5 - 25.5 Vdc adj.)|24 Vdc<br>(22.5 - 28.5 Vdc adj.)|||
|**-Tolerance**<br>~~ey~~<br>~~es~~|< ±2% overall (combination Line, load, time and temperature related changes)|||||
|**-Ripple4**<br>~~es~~<br>~~es~~|< 50 mVpp|||||
|**Overvoltage Protection**<br>~~es~~<br>~~es~~<br>~~es~~|> 30 Vdc, but < 33 Vdc, auto recovery<br>~~rn~~<br>~~I~~|||||
|**Nominal Current**<br>~~es~~<br>~~es~~<br>~~es~~|2.5 A (60 W)<br>~~rn~~|3.8 A (92 W)<br>~~I~~|5 A (120 W)|10 A (240 W)|20 A (480 W)|
|**-Current Limit**<br>~~es~~<br>~~es~~<br>~~es~~|Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)<br>~~rn~~<br>~~I~~<br>~~nD~~|||||
|**Holdup Time5**<br>~~es~~<br>~~es~~<br>~~es~~|> 50 ms<br>~~nD~~|> 100 ms||||
|**Parallel Operation**<br>~~es~~<br>~~es~~<br>~~ee~~|Single or Parallel use is selectable via Front Panel Switch (SDN 2.5, 4 should not be used in parallel as Class 2 rating would be violated.)<br>~~nD~~|||||
|**General**<br>~~es~~<br>~~ee~~||||||
|**EMC:**<br>**-Emissions**<br>~~ee~~<br>~~es~~|EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.|||||
|**-Immunity**<br>~~ee~~<br>~~es~~|EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5<br>Isolation Class 4,EN61000-4-11;|||||
|**Approvals**<br>~~es~~<br>~~a ee~~|EN60950; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC60079-15 (Class 1, Zone 2, Hazardous<br>Location, Groups A, B, C, D w/ T3A temp class up to 60°C Ambient.) SEMI F47 Sag Immunity. SDN 2.5 & SDN 4 - UL60950 testing to<br>include approval as Class 2power supplyin accordance with UL1310.<br>~~ee~~|||||
|**Temperature**<br>~~a~~|Storage: -25oC...+85oC Operation. -10°-60oC full power with operation to 70°C possible with a linear derating to half power from 60oC to 70oC (Con-<br>vection cooling,no forced air required). Operation upto 50% loadpermissible with sideways or front side upmountingorientation.<br>|||||
|**Humidity**<br>~~NLL~~|The relative humidityis < 90% RH, noncondensing; IEC 68-2-2, 68-2-3.<br>~~NLL~~|||||
|**MTBF:**<br>~~NLL~~|> 820,000 hours<br>~~NLL~~|> 640,000 hours<br>~~NLL~~||> 600,000 hours<br>~~NLL~~|> 510,000 hours<br>~~NLL~~|
|**- Standard**<br>~~a~~|Bellcore Issue 6 Method 1 Case 3 @ 40oC||||MIL STD 217F @ 30oC|
|**Warranty**|5 years|||||
|**General Protection/**<br>**Safety**<br>~~a~~<br>~~Rs~~|Protected against continuous short-circuit, overload, open-circuit. Protection Class 1 (IEC536),<br>degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950)|||||
|**Status Indicators**<br>~~Rs~~<br>~~ee~~|Green LED and DC OK signal (N.O. Solid State Contact rated 200 mA / 60 Vdc)|||||
|**Installation**<br>~~Rs~~<br>~~ee~~||||||
|**Fusing**<br>**-Input**<br>~~ee~~|Internally fused. External 10 A slow acting fusing for the input is recommended to protect input wiring.|||||
|**-Output**<br>~~ee~~<br>~~a~~<br>~~Rs~~<br>~~Le~~|Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for<br>wire/loads if 2x Nominal O/P current ratingcannot be tolerated. Continuous current overload allows for reliable fuse tripping.|||||
|**Mounting**<br>~~Rs~~<br>~~Le~~|Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).|||||
|**Connections**<br>~~Rs~~<br>~~Le~~<br>~~es~~|**Input:**IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for<br>flexible conductors.**Output:**Two connectorsper output,connector size range: 16-10 AWG(1.5 - 6 mm2)for solid conductors.|||||
|**Case**<br>~~Le~~<br>~~es~~<br>~~—~~|Fully enclosed metal housing with fine ventilation grid to keep out small parts.<br>|||||
|**-Free Space**<br>~~es~~<br>~~—es~~|25 mm above and below,<br>25 mm left and right, 10 mm in front<br>~~en~~||25 mm above and below,<br>25 mm left and right,<br>15 mm in front<br>~~en~~|70 mm above and below, 25 mm left and right,<br>15 mm in front<br>~~en~~||
|**H x W x D (inches/mm)**<br>~~—es~~<br>~~rs~~|4.88. x 1.97 x 4.55<br>(124 x 50 x 116)<br>~~en~~<br>~~rs~~|4.88 x 2.56 x 4.55<br>(124 x 65 x 116)<br>~~en~~<br>~~PD~~||4.88 x 3.26 x 4.55<br>(124 x 83 x 116)<br>~~en~~|4.88 x 6.88 x 4.55<br>(124 x 175 x 116)<br>~~en~~|
|**Weight (lbs/kg)**<br>~~es~~<br>~~rs~~|1 (.45)<br>~~en~~<br>~~rs~~|1.5 (.68)<br>~~en~~<br>~~PD~~||2.2 (0.1)<br>~~en~~|3 (1.36)<br>~~en~~|
1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor.
4. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
5. Full load, 100 Vac Input @ Tamb = +25°C
3. Losses are heat dissipation in watts at full load, nominal input line.
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**107**
a **4**
Power Supplies
DEMK0 06 ATEX 05 21715U
SDN-P Specifications (Single Phase), 12 Vdc and 48 Vdc Output
**Description Catalog Number** ~~esen Paes~~ **SDN 9-12-100P SDN 5-48-100P** ~~ee~~ **SDN 16-12-100P** ~~Ree~~ **Input Nominal Voltage** 115/230 Vac auto select ~~es~~ **-AC Range** 85-132/176-264 Vac ~~ee~~ **-DC Range[1]** 210-375 Vdc ~~Re~~ **-Frequency** 47-63 Hz, 400 Hz ~~ee Pee~~ **Nominal Current[2]** 2.0 A / 1.5 A 4 A / 2.3 A 3.3 A / 1.7 A **-Inrush current max.** Typ. < 20 A typ. < 40 A ~~es nD ee Pe~~ **Efficiency[2] (Losses[3] )** > 84% typ. (17.28 W) > 88% typ. (28.8 W) > 84% typ. (30.72 W) ~~es~~ **Power Factor Correction** Units fulfill EN61000-3-2 ~~Pee~~ **Output Nominal Voltage** 12 V (11.8-15.2 Vdc Adj.) 48 V (35.8 - 52 Vdc Adj.) 12 V (11.6-14.0 Vdc Adj.) ~~PC~~ **Tolerance** < ±2 % overall (combination Line, load, time and temperature related changes) ~~Rs~~ **-Line Regulation** < 0.5% ~~es~~ **-Load Regulation** < 0.5% ~~es~~ **-Time & Temp. Drift** < 1% ~~es~~ **Ripple[3]** < 50 mVpp ~~Re Pe~~ **Overvoltage Protection** < 16 Vdc with auto-recovery < 60 Vdc with auto-recovery ~~ee~~ < 16 Vdc with auto-recovery ~~Pe~~ **Nominal Current** 9 A (108 W) 5 A (240 W) 16 A (192 W) **-Current Limit[4]** 110% of nominal - Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) ~~es ee~~ **Holdup Time[5]** >20 ms (Full load, 100 Vac Input @ Tamb=+25°C) to 95% output Voltage ~~es~~ **Parallel Operation** Supplies will not be damaged with parallel operation ~~es~~ **Power Back Immunity** 16 Vdc 60 Vdc 16 Vdc ~~esOD(OU Ce~~ **General EMC: -Emissions** EN61000-6-3, EN61204-3, EN55022 Class B, EN61000-3-2, EN61000-3-3 ~~ee~~ EN61000-6-2, EN61204-3, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, **-Immunity** IEC61000-4-8, IEC61000-4-11 UL508 Listed, cULus; UL 60950-1, cURus; CE (LVD 73/23 & 93/68/EEC), (EMC 89/336 & 93/68/EEC). EN61000-3-2; **Approvals** UL 60079-15 pending (Class 1, Zone 2 hazardous location, Groups IIA, IIB, IIC w/ T3 temp. class up to 60°C Ambient.); ~~a ee~~ EN60079-15 (ATEX); SEMI F47 Sag Immunity, RoHS Storage: -25 to +85[o] C, Operation -10 to +60[o] C full power; with linear derating to half power from 60 to 70[o] C ~~ee~~ **Temperature** ~~ee~~ (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. ~~ee~~ **Humidity** < 90% RH, non-condensing; IEC 68-2-2, 68-2-3 **MTBF:** >500,000 hrs ~~ee~~ **- Standard** Telcordia/Bellcore, Issue Case 3 @25[o] C ~~ee es~~ **Warranty** 5 years Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class 1 (IEC536), ~~a~~ **General Protection/Safety** Degree of Protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950) ~~ee~~ **Status Indicators (Visual)** Green LED on when Vout > 75% (with ± 5% tolerance) of nominal output voltage ~~Gn~~ **Status Indicators (Relay)** Normally Open solid state relay - signal active when Vout >70% of nominal output voltage (rated up to 200 mA, 60 Vdc) **Installation** ~~Ce~~ **Fusing -Input** Internally fused ~~ee~~ Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required if ~~ee~~ **-Output** Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Unit should handle normal shock and vibration of industrial use ~~ee~~ **Mounting** and transportation without falling off the rail. **Input:** Screw terminals, connector size range: 16-10 AWG (1.5-6mm[2] ) for solid conductors. **Connections** ~~a~~ **Output:** Two terminals per output, connector size range: 16-10 AWG (1.5-6mm[2] ) for solid conductors. ~~RR~~ **Case** Fully enclosed metal housing with fine ventilation grid to keep out small parts. ~~es~~ **-Free Space** 70 mm above and below, 25 mm left and right, 15mm in front ~~(OR~~ **H x W x D (inches/mm)** 4.88 × 2.56 × 4.55 (124 x 65 × 116) 4.88 × 3.26 × 4.55 (124 × 83 × 116) ~~Pee~~ **Weight (lbs/kg)** 2.4 (1.05) ~~eee~~ 3.3 (1.48) 1. Input current ratings are specified with low input, line conditions and worst case efficiency 4. Unit shall not shutdown or ‘hiccup’ during overload or short circuit. Maximum current value values. Input current at nominal input settings will be typically half these values. shown shall be maintained indefinitely without damage to the supply. Voltage shall drop 2. Losses are heat dissipation in watts at full load, nominal line. according to amount of overload to protect supply from damage.
3. Ripple/ noise is stated as typical values when measured with a 20 MHz bandwidth scope and 50 Ohm resister.
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
**108**
**4** L
Power Supplies
SDN-P Specifications (Three Phase)
|**Description**<br>~~ISS~~<br>~~ee~~|**Catalog Number**<br>~~ISS~~|**Catalog Number**<br>~~ISS~~|**Catalog Number**<br>~~ISS~~|**Catalog Number**<br>~~ISS~~|**Catalog Number**<br>~~ISS~~|
|---|---|---|---|---|---|
||**SDN 5-24-480**<br>~~ISS~~|**SDN 10-24-480**<br>~~ISS~~|**SDN 20-24-480C**<br>~~ISS~~|**SDN 30-24-480**<br>~~ISS~~|**SDN 40-24-480**<br>~~ISS~~|
|**Input**<br>~~ee~~||||||
|**Nominal Voltage**<br>~~ee~~<br>~~——17J$#$#IJI~~|1Ø or 3Ø 380-480 Vac<br>~~——17J$#$#IJIOd~~||1Ø or 3Ø<br>380 - 480 Vac1<br>~~Od~~|3Ø 380 - 480 Vac<br>~~Od~~||
|**-AC Range**<br>~~ee~~<br>~~——17J$#$#IJI~~|340 - 576 Vac<br>~~——17J$#$#IJIOd~~|||||
|**-DC Range2**<br>~~——17J$#$#IJI~~|450 - 820 Vdc<br>~~——17J$#$#IJIOd~~|||||
|**-Frequency**<br>~~——17J$#$#IJI~~|47 - 63 Hz<br>~~——17J$#$#IJIOd~~|||||
|**Nominal Current3**|0.5 A|0.8 A|1.5 A|2.0 A|3.0 A|
|**-Inrush current max.**<br>~~OO~~|typ. < 18 A<br>~~OO~~|||typ. < 30 A<br>~~OO~~||
|**Efficiency (Losses4)**<br>~~OO~~|> 90% typ. (12 W)<br>~~OO~~|> 90% typ. (48 W)<br>~~OO~~||> 90% typ. (72 W)<br>~~OO~~|> 90% typ. (96 W)<br>~~OO~~|
|**Power Factor**<br>**Correction**<br>~~a~~|Units Fulfill EN61000-3-2<br><br>~~SSee~~|||||
|**Output**<br>~~SS~~<br>~~SSee~~||||||
|**Nominal Voltage**<br>~~SS~~|24 Vdc (22.5 - 28.5 Vdc adj.)<br>~~SS~~<br>~~SSee~~|||||
|**-Tolerance**<br>~~SS~~<br>~~pe~~|< ±2% overall (combination Line, load, time and temperature related changes)<br>~~SS~~<br>~~SS ee~~<br>~~pe~~|||||
|**-Ripple5**<br>~~pe~~|< 50 mVpp<br>~~pe~~|||||
|**Overvoltage**<br>**Protection**<br>~~a~~<br>~~es~~<br>~~TE~~|> 30 Vdc, but < 33 Vdc, auto recovery<br>~~nD~~<br>~~II~~<br>~~(~~<br>~~TEoooEo~~|||||
|**Nominal Current**<br>~~es~~<br>~~TE~~|5 A (120 W)<br>~~nD~~<br>~~TEooo~~|10 A (240 W)<br>~~I~~<br>~~ooo~~|20 A (480 W)<br>~~I~~<br>~~Eo~~|30 A (720 W)<br>~~(~~|40 A (960 W)|
|**-Peak Current**<br>~~es~~<br>~~TE~~|6A,<br>2x Nominal Current < 2 sec.<br>~~nD~~<br>~~TEooo~~|12A,<br>2x Nominal Current < 2 sec.<br>~~I ~~<br>~~ooo~~|25A,<br>2x Nominal Current < 2 sec.<br> ~~I~~<br>~~Eo~~|35A, 2x Nominal Current<br>< 2 sec.<br>~~(~~|45A, 2x Nominal Current<br>< 2 sec|
|**-Current Limit**<br>~~TE~~<br>~~es~~|Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)<br>~~TE ooo Eo~~<br>~~IDf~~|||||
|**Holdup Time6**<br>~~es~~|> 40 ms<br>~~I~~||> 28 ms<br>~~Df~~|> 20 ms<br>~~Df~~||
|**Parallel Operation**<br>~~es~~<br>~~RC~~|5A through 30A units may be passively paralleled by selecting the “P” position of the switch on the unit. The SDN 40 contains active current balancing.<br>~~IDf~~|||||
|**General**<br>~~RC~~||||||
|**EMC:**<br>**-Emissions**<br>~~RCa~~<br>~~es~~|EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.|||||
|**-Immunity**<br>~~es~~|EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4<br>Level 4 input and Level 3 output;EN61000-4-5 Isolation Class 4,EN61000-4-11;|||||
|**Approvals**<br>~~es~~<br>~~a~~|CB Scheme, EN60950; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, UL60079-15<br>Class 1,Zone 2 Hazardous Location,Groups IIA,IIB,IIC w/T3 tempclass upto 60°C Ambient.<br>|||||
|**Temperature**<br>~~pp~~|Storage: -25°C...+85°C Operation. -10°C -60°C full power with operation to 70°C possible with a linear derating to half power from 60°C to 70°C<br>(Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. The relative<br>humidityis < 90% RH,noncondensing;IEC 68-2-2,68-2-3.<br>~~pp~~|||||
|**MTBF:**<br>~~pp~~<br>~~_~~<br>~~oysStds}—_—__]~~|> 1,110,000 hours<br>~~pp~~<br>~~oysStds}—_—__]~~|> 940,000 hours<br>~~pp~~<br>~~oysStds}—_—__]~~|> 550,000 hours<br>~~pp~~<br>~~oysStds}—_—__]HNN~~|> 620,000 hours<br>~~pp~~<br>~~HNN~~|> 490,000 hours<br>~~pp~~<br>~~HNN~~|
|**- Standard**<br>~~_~~<br>~~oysStds}—_—__]~~|MIL STD 217F @ 30oC<br>~~oysStds}—_—__]HNN~~|||||
|**Warranty**<br>~~_~~<br>~~oysStds}—_—__]~~|5 years<br>~~oysStds}—_—__]HNN~~|||||
|**General Protection/**<br>**Safety**<br>~~_~~<br>~~oysStds}—_—__]~~<br>~~a~~<br>~~ee~~|Protected against continuous short-circuit, overload, open-circuit. Protection Class 1 (IEC536), degree of protection IP20 (IEC 60529) Safe low voltage:<br>SELV (acc. EN60950)<br>~~oysStds}—_—__] HNN~~|||||
|**Status Indicators**<br>~~ee~~|Green LED on when Vout= 18V or greater.|||||
|**Installation**<br>~~ee~~||||||
|**Fusing**<br>**-Input**|Internally fused|||||
|**-Output**<br>~~a~~<br>~~ee~~|Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads<br>if 2x Nominal O/P current ratingcannot be tolerated. Continuous current overload allows for reliable fuse tripping.|||||
|**Mounting**<br>~~ee~~|Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).|||||
|**Connections7**<br>~~ee~~<br>~~sérN-~~|**Input:**IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors.<br>**Output:**Two connectorsper output,connector size range: 16-10 AWG(1.5-6 mm2)for solid conductors.<br>~~sérN-~~|||||
|**Case**<br>~~a~~|Fully enclosed metal housing with fine ventilation grid to keep out small parts.<br>~~ns~~|||||
|**-Free Space**<br>~~a~~<br>~~es~~|25 mm above and below, 25 mm left and right,<br>15 mm in front<br>~~ns~~<br>~~ns~~<br>~~nn UI~~||70 mm above and below, 25 mm left and right , 15 mm in front<br>~~UI (I~~|||
|**H x W x D (inches/mm)**<br>~~a~~<br>~~es~~<br>~~a~~|4.88 x 2.91 x 4.55<br>(124 x 73 x 116)<br>~~ns~~<br>~~ns~~<br>~~Rn~~|4.88 x 3.5 x 4.55<br>(124 x 89 x 116)<br>~~ns~~<br>~~nn UI~~<br>~~Rn~~|4.88 x 5.9 x 4.55<br>(124 x 150 x 116)<br>~~UI (I~~<br>~~I Ot~~|4.88 x 9.72 x 4.55<br>(124 x 247 x 116)<br>~~(I~~<br>~~Ot~~|4.88 x 11.1 x 4.55<br>(124 x 282 x 116)|
|**Weight (lbs/kg)**<br>~~es~~<br>~~a~~|1.7 (.77)<br>~~ns~~<br>~~Rn~~|2.16 (.98)<br>~~nn UI~~<br>~~Rn~~|3.97 (1.8)<br>~~UI (I~~<br>~~I Ot~~|4 (1.81)<br>~~(I~~<br>~~Ot~~|6.6 (2.99)|
2. Not UL listed for DC input.
3. Input current ratings are conservatively specified with low input, worst case efficiency and power factor.
6. Full load, 100 Vac Input @ Tamb = +25°C
7. For the SDN 40-24-480, output: one (+) two (-) connectors, size range 16-5 AWG
- (1.5016 mm[2] ) solid conductor.
Visit our website at www.solahd.com or
contact Technical Services at (800) 377-4384 with any questions.
**109**
**==> picture [541 x 648] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 Power Supplies<br>BS [SOLD] A Oo Oo<br>SDN-P Series Dimensions<br>W D<br>Dimensions - inches (mm)<br>-_ > —\—_ — ee Catalog<br>Number<br>H W D<br>+ + - -<br>24 VDC / 2.5 A OK 12 Vdc<br>24OK - 28 V NEC Class 2Power Supply SDN 9-12-100P 4.88 (124) 2.56 (65) 4.55 (116)<br>Single<br>Parallel SDN 16-12-100P 4.88 (124) 3.26 (83) 4.55 (116)<br>S O L A<br>24 Vdc<br>Power Supply ® 1) ———<br>SDN 2.5 - 24 - 100P ® |<br>iq | SDN 2.5-24-100P 4.88 (124) 1.97 (50) 4.55 (116)<br>C UL US LISTED SDN 4-24-100LP 4.88 (124) 2.56 (65) 4.55 (116)<br>115/230 VAC 1.3 - 0.7 A 50/60 HZ<br>N L SDN 5-24-100P 4.88 (124) 2.56 (65) 4.55 (116)<br>3 \ | | | | | | |<br>(exer) c\ i) ee SDN 5-24-480 4.88 (124) 2.91 (73) 4.55 (116)<br>ns nn<br>SDN 10-24-100P 4.88 (124) 3.26 (83) 4.55 (116)<br>SDN 20-24-100P 4.88 (124) 6.88 (175) 4.55 (116)<br>48 Vdc<br>SDN 5-48-100P 4.88 (124) 3.26 (83) 4.55 (116)<br>—<br>W » <+_—_—_ D —_><br>rc ™ !<br>11 }<br>S O L A<br>)<br>Power Supply<br>SDN 20 - 24 - 480C N [y]<br>€ C OF UL US LISTED ><br>1.7/1.5A/Phase3PH 380/500 VACInput: 50/60 Hz Electronically protected24 VDC / 20 AOutput: ®<br>| L1 L2 L3 2428V - + + - - t,<br>| eae Ll Le p ae a | |<br>_ J<br>Dimensions - inches (mm)<br>Catalog<br>es<br>Number<br>H W D<br>SDN 10-24-480 4.88 (124) 5.90 (150) 4.55 (116)<br>SDN 30-24-480 4.88 (124) 9.72 (247) 4.55 (116)<br>se<br>SDN 40-24-480 4.88 (124) 11.10 (282) 4.55 (116)<br>ee es ee<br>Ove OK<br>FMuse ldroa<br>doe<br>Co<br>itnnuo<br>Mdusoe<br>Si<br>lUnges<br>e<br>Para<br>lllUes<br>e<br>Res<br>fteuse<br>dmoe<br>H<br>H<br>**----- End of picture text -----**<br>
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**110**
**4**
Power Supplies
## SDN-P Series Mounting
## DIN Rail Mounting
Snap on the DIN Rail:
1. Tilt unit slightly backwards
2. Put it onto the DIN Rail
3. Push downwards until stopped
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer has locked
Alternative Panel Mount: Using the optional SDN-PMBRK2 accessory, the unit can be screw mounted to a panel.
Detachment from DIN Rail:
## Chassis Mounting
## Dimensions
Instead of snapping a Sola SDN™ unit on the DIN Rail, you can also attach it using the screw mounting set SDN-PMBRK2.
This set consists of two metal brackets, which replace the existing two aluminum profiles.
Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions.
**111**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →