Image not available
Illustrative purposes only
SDN 20-24-480CD
POWER SUPPLY, AC-DC, 24V, 20A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SOLAHD
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:480W; Output Voltage - Output 1:24V; Output Current - Output 1:20A; Output Voltage - Output 2:-; 56AC3159
- Product Range: SDN-C Series
- No. of Outputs: 1 Output
- Output Power Max: 480W
- Current, Output 4: -
- Input Voltage VAC: 320V AC to 540V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 950.04 € |
| Current stock | 25+ |
| Lead time | 30 days |
Power Supplies
## SDN-C Performance DIN Rail Series
High performance specifications and extensive international certifications ensure that the SolaHD SDN-C is suitable for the most extreme environments, including hazardous locations and off-shore applications. Features like wide operating temperature range, power boost capability, and adjustable output voltage ensure reliable operation in the harshest industrial environments. Parallel operation, extensive LED diagnostics, and universal AC or DC input voltage simplify installation and maintenance. For added reliability, the SDN-C power supplies can be used with the SolaHD Redundancy modules to provide redundant power supply operation.
## Certifications and Compliances *
**==> picture [65 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
E61379 E137632<br>E234790<br>IECEx<br>**----- End of picture text -----**<br>
## All Models
## Applications
- Industrial Automation
- Process Control
- Material Handling and Conveyors
- Hazardous Locations
- Marine Applications
## Features
- Extensive international hazardous location certifications, including Class I, Zone 2, ATEX, IECEx, ExEAC. Hazardous location temperature code (T-Code) rating of T4.
- International off-shore certifications, including ABS and DNV-GL
- PowerBoost[TM] enables short duration overload capability, to start loads with high inrush current
- Three LEDs provide extensive diagnostics
- Dual output terminals for convenience in wiring
- DC OK relay to provide diagnostic information to a PLC, controller, or monitoring system
- Universal AC and DC input voltages to accommodate global requirements
- Wide operating temperature range accommodates both extreme hot and extreme cold environments
- Active Power Factor Correction on most models
- Parallel operation capability standard
- Supports redundant power supply operation using optional SDN™ Redundancy modules
- 5-year limited warranty
- Listed, Ind. Control Equipment, E61379
- UL 508, CSA C22.2 No. 107.1
- UL Recognized Component, ITE, E137632
- UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition • Wks UL Recognized Component, Class I, Div 2; Class I Zone 2; T4 E234790
- - Low Voltage Directive
- IEC/EN60950-1, 2nd Edition
- RoHS Compliant
Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C, SDN 20-24-480CD
- UL Recognized Component, Haz. Loc., E234790
- - UL60079-0/CSA E60079-0, UL 60079-15, CSA E60079-15
- Class I, Zone 2, AEx nA nC IIC, Ex nA nC IIC
- €x) ATEX Directive
- EN60079-0, EN60079-7, EN60079-15
- €x) II 3 G, Ex ec nC IIC Gc
- _**IECEx**_ Certified
- IEC 60079-0, IEC 60079-7, IEC 60079-15
- Ex ec nC IIC Gc
Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C
- Ex EAL TR CU 012/2011 Safety of Equipment intended for Explosive Atmospheres
- Type Approval
Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C
- Type Approved
* Refer to user manual for installation requirements when used in hazardous locations.
- Models SDN 5-24-100C, SDN 10-24-100C, SDN 20-24-100C, SDN 40-24-100C
- • [¢ Certified
**122**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions.
© December 2018
Power Supplies
## Related Products
- SDN-C Redundancy Modules
## Accessories
- Chassis Mount Brackets
- IP67 SCP-X Extreme Environment Series
- SDU UPS
## The SolaHD Difference
**==> picture [529 x 358] intentionally omitted <==**
**----- Start of picture text -----**<br>
Multiple output connections for ease of Rugged metal housing<br>wiring multiple devices<br>a<br>[8:3.9.9.9.9<br>Visual LED diagnostics show input and<br>output status (see table below)<br>DC OK Relay Terminals provide<br>diagnostic information to a PLC<br>or controller<br>Single or parallel use selectable by user {<br>| Adjustable output voltage<br>Clearly labeled front panel SOLA<br>No internal fan, no extra cooling required<br>in any power level<br>Multiple certifications for versatility in applications<br>e(Ut)us usten CE<br>Automatically adjusts for global Input voltages<br>Narrow width<br>saves panel space<br>**----- End of picture text -----**<br>
## LED Light Status Conditions
||**Normal**|**AC Power Loss**|**AC Input Low**|**No DC**|**High Load**|**Overload**|**Hot**|**Too Hot**|
|---|---|---|---|---|---|---|---|---|
|**Input**|Green|-|Amber|Green|Green|Green|Green|Green|
|**Output**|Green|-|Green|-|Amber|Amber|Green|-|
|**Alarm**|-|-|-|Red|Amber|Red|Amber|Amber|
**123**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions. © December 2018
Power Supplies
## SDN-C Specifications (Single Phase)
|**Description**||**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|---|---|---|---|---|---|
||**SDN 16-12-100C**|**SDN 5-24-100C**|**SDN 10-24-100C**|**SDN 20-24-100C**|**SDN 40-24-100C**|
||**Input**|||||
|**Nominal AC Voltage (Range)**|100 - 240 Vac (85-264 Vac)|||||
|**Nominal DC Voltage (range)**|100-340 Vdc (90-375 Vdc)|||100-250 Vdc<br>(90-275 Vdc)|120-340 Vdc<br>(108-375 Vdc)|
|**Frequency**|43 - 67 Hz|||||
|**Nominal Current1**|1.77 – 0.9 A|1.65 - 0.55 A|3.2 - 1.0 A|6 - 3 A|12 - 4 A|
|**-Inrush current**|Typ. <5.8A at 120 Vac,<br><12.7A at 230 Vac,<br>measured at 25°C|Typ. <3.7A at 120 Vac,<br><7.4A at 230 Vac,<br>measured at 25°C|Typ. <12.7A at 120 Vac,<br><24.8A at 230 Vac,<br>measured at 25°C|Typ. <5.8A at 120 Vac,<br><11.5A at 230 Vac,<br>measured at 25°C|Typ. <5.8A at 120 Vac,<br><11.5A at 230 Vac,<br>measured at 25°C|
|**Efficiency (Losses2)**|> 86.5% typ. (24 W)|> 88% typ. (14 W)|> 90% typ. (24 W)|> 92% (38 W)|> 93 % (67 W)|
|**Power Factor Correction**|Active power factor correction typ. 0.98 @ 115 Vac/ 0.92 @ 230 Vac|||||
||**Output**|||||
|**Nominal Voltage**|12 V (12-15 Vdc Adj.)|24 V (23.5-28.5 Vdc Adj.)||||
|**Initial Voltage Setting**|12.5 V ± 1%|24.5 V ± 1%||||
|**-Tolerance**|< ±2 % overall (combination Line, load, time and temperature related changes)|||||
|**-Ripple3**|< 100 mVpp|< 50 mVpp||< 100 mVpp||
|**PARD**<br>**(Periodic and Random Deviation)**|100 mVpp max|||||
|**Nominal Current (Rated Power**<br>**at +60°C)**|16 A (192 W)|5 A (120 W)|10 A (240 W)|20 A (480 W)|40 A (960 W)|
|**Parallel Operation4**|Single or Parallel operation selectable via front switch.||||Active Paralleling.|
|**Turn On Time**|< 1 s after AC is applied to input at full resistive load ( Tamb=+25°C ). <1.5 ms with capacitive load 7000μF|||||
|**Holdup Time**|>40ms (Full load, 100 Vac<br>Input @ Tamb=+25°C) to<br>95% output voltage|>20 ms (Full load, 100 Vac Input @ Tamb=+25°C) to 95% output voltage||||
|**Voltage Fall Time**|<150 mS from 95% to 10% rated voltage @ full load (Tamb=+25°C)|||||
||**Protection**|||||
|**-Short Circuit**|Output automatically goes to near zero and output is protected from continuous short circuit. Auto-recovery.|||||
|**-Peak Current5**|1.5 × Nominal Current for > 4 seconds minimum while holding voltage > 20 Vdc (> 10 Vdc for SDN 16-12-100C)|||||
|**-Overcurrent Protection**|PowerBoost™|||||
|**Back EMF Immunity**|< 18 V No damage,<br>auto-recovery|< 35 V No damage, auto-recovery||||
|**Overvoltage Protection**|> 18 but < 20 Vdc,<br>auto-recovery|> 30.5 but < 33 Vdc, auto-recovery||||
|**Overtemperature Protection**|LED Alarm and Output shutdown , auto-recovery|||||
||**Environmental Data**|||||
|**Emissions**|EN61000-6-3, EN61000-6-4, Class B EN55011, EN61000-3-2 Class A,<br>Class B EN 55032, EN 61326-1 Class B, EN 61000-3-3|||||
|**Immunity**|EN 55024, EN 61000-6-1, EN 61000-6-2, EN 61326-1, SEMI F47|||||
|**General Protection/ Safety**|Protected against continuous short circuit, continuous overload, continuous open circuit.<br>IEC 60950-1: Class I Earthed, Output is SELV (Safety Extra Low Voltage), Environmental Rating: Pollution Degree 2<br>IEC 60529 Ingress Protection Rating: IP20|||||
|**Temperature6**|Storage: -40°C to +85°C, Operation -40°C to +60°C full power, with linear derating to 75% power from +60°C to 70°C (Convection cooling).<br>Operation upto 50% load with sideways or front-side-upmountingorientation.|||||
|**Humidity**|5 to 95 % RH Non-condensing; IEC 60068-2-2, IEC 60068-2-3|||||
|**Vibration**|2.5g RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6|||||
|**Shock**|10(g) RMS, three axes, 11mseconds for each axis - IEC 60068-2-27|||||
|**Altitude**|0 to 6000 meters (0 to 20,000 feet) per MIL-STD-810F|||||
1. Input current ratings are conservatively specified with low AC input, worst case efficiency and power factor.
2. Losses are heat dissipation in watts at full load, nominal AC input line.
3. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4. All models are capable of paralleling. For redundant operation, please use external Redundancy module. Only the 40A uses Active paralleling scheme. Please refer to user manual for details.
5. Peak current is calculated at nominal voltage levels.
6. Contact tech support for operation at -40°C.
**124**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions.
© December 2018
Power Supplies
## SDN-C Specifications (Single Phase) continued
**==> picture [538 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog Number<br>Description<br>SDN 16-12-100C SDN 5-24-100C SDN 10-24-100C SDN 20-24-100C SDN 40-24-100C<br>Reliability<br>Telcordia<br>SR-332 Issue 2 >2,088,000 hours @ 115 Vac >1,800,000 hours @ 115 Vac > 550,000 hours @ 115 Vac >800,000 hours @ 115 Vac >550,000 hours @ 115 Vac<br>Method 1 Case 3 >2,133,000 hours @ 230 Vac >2,100,000 hours @ 230 Vac >650,000 hours @ 230 Vac >850,000 hours @ 230 Vac >570,000 hours @ 230 Vac<br>@ 25°C<br>MTBF<br>Telcordia SR-332<br>Issue 2 >1,112,000 hours @ 115 Vac >1,000,000 hours @ 115 Vac >300,000 hours @ 115 Vac >500,000 hours @ 115 Vac >360,000 hours @ 115 Vac<br>Method 1 Case 3 >1,170,000 hours @ 230 Vac >1,100,000 hours @ 230 Vac >400,000 hours @ 230 Vac >570,000 hours @ 230 Vac >370,000 hours @ 230 Vac<br>@ 40°C<br>Installation<br>Fusing -Input Input Branch fuse or circuit breaker should be provided by customer. See manual for details.<br>Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for<br> -Output wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.<br>Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.<br>13-10 AWG<br>(3-6 mm [2] ) solid/stranded<br>Input 16–10 AWG (1.5–6 mm [2] ) solid or stranded conductors. conductors.<br>Screw torque: 4.4-6.5 lb-inch (50-73 N-cm).<br>Screw Torque: 4.4 lb-inch<br>(50 N-cm).<br>Connections [7,8 ]<br>(Screw Type) 7–6 AWG (10.6–13<br>mm [2] ) solid/stranded<br>Output 16–10 AWG (1.5–6 mm [2] ) for solid or stranded conductors. conductors.<br>(dual output Screw torque: 4.4-6.5 lb-inch (50-73 N-cm).<br>Screw Torque: 15.6<br>terminals) lb-inch<br>(176 N-cm)<br>Above & Below 0.98 in (25 mm) 1.6 in (40 mm) 0.98in (25mm)<br>-Free Space Left & Right 0.39 in (10mm) 0.59in (15mm)<br>Front 0.59 (15)<br>4.85 × 2.36 × 4.36 4.85 × 1.97 × 4.36 4.85 × 2.36 × 4.36 4.85 x 3.42 x 4.98 4.85 x 7.09 x 4.81<br>Dimensions - WxDxH in (mm) (123.0 × 60.0 × 110.0) (123.0 × 50.0 × 110.0) (123.0 × 60.0 × 110.0) (123.0 x 87.0 x 127.0) (123.0 x 180.0 x 122.0)<br>Weight - lbs (kg) 1.76 (0.80) 1.3 (0.6) 1.7 (0.8) 3.0 (1.4) 6.0 (2.8)<br>General<br>Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. IP20 touch proof<br>Visual: 3 status LEDs (Input, Output, Alarm)<br>Status Indicators Relay: N.O. contact rated 200mA/50 Vdc<br>Signal Active when Vout > 18.5 Vdc +/-5% (Vout > 10.8 Vdc for SDN 16-12-100C)<br>Warranty 5 Year Limited Warranty<br>**----- End of picture text -----**<br>
7. Screw terminals. Use only one copper wire per terminal. Non-ratcheting torque driver recommended.
8. SDN 40-24-100C only — Provided with Signal Mode terminal block which includes the following features: DC OK, Ground signal, PS ON, I_share connection. Refer to Signals Manual for terminal connection details..
**125**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions. © December 2018
Power Supplies
## SDN-C Specifications (Three Phase)
|**Description**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|---|---|---|---|---|
||**SDN 5-24-480C**|**SDN 10-24-480C**|**SDN 20-24-480CD**|**SDN 40-24-480C**|
||**Input**||||
|**Nominal AC Voltage (Range)**|380 - 480 Vac (320 - 540 Vac), 3-phase||||
|**Two-phase input1**|Yes||||
|**Nominal DC Voltage (Range)**|600 Vdc (+/- 50 Vdc)||||
|**Frequency**|50/60 Hz||||
|**Nominal Current2**|3 x 0.5 A|3 x 0.8 A|3 x 0.9A|3 x 1.6A|
|**-Inrush current max.**|Typ. < 25 A||Negligible||
|**Efficiency (Losses3)**|> 85% (18 W)|91% (24W)|93% (42 W)|94% (78 W)|
|**Power Factor Correction**|Meets EN61000-3-2 Class A||Active Power Factor Correction > 0.92||
||**Output**||||
|**Nominal Voltage 4**|24 V (23.5 – 28.5 Vdc Adj.)||||
|**Initial Voltage Setting**|24.5 V ± 1%||||
|**-Tolerance**|< ±2 % overall (combination Line, load, time and temperature related changes)||||
|**-Ripple5**|< 50 mVpp||< 100 mVpp||
|**PARD**<br>**(Periodic and Random Deviation)**|100 mVpp max||200 mVpp max||
|**Nominal Current(Rated Power)**|5 A (120 W)|10 A (240 W)|20 A (480 W)|40 A (960 W)|
|**Parallel Operation6**|Single or Parallel operation selectable via front switch.|||Active Paralleling.|
|**Turn On Time**|< 1 s after AC is applied to input at full resistive load ( Tamb=+25°C ). <1.5 s With capacitive load 7000μF||||
|**Holdup Time**<br>**(Full load,**<br>**100 Vac Input @ T = +25°C)**|20 ms|||15 ms|
|**Voltage Fall Time**|<150 mS from 95% to 10% rated voltage @ full load (T =+25°C)||||
||**Protection**||||
|**-Short Circuit Current**|Voltage output automatically goes to near zero and output is protected from continuous short circuit. Auto-recovery.||||
|**-Peak Current7**|1.5 × Nominal Current for > 4 seconds minimum while holding voltage > 20 Vdc||||
|**-Current Limit**|PowerBoost™||||
|**Back EMF Immunity**|< 35 V No damage, auto-recovery||||
|**Overvoltage Protection**|> 30.5 but < 33 Vdc, auto-recovery||||
|**Over Temperature Protection**|LED Alarm and Output shutdown , auto-recovery||||
||**Environmental Data**||||
|**Emissions**|EN 61000-6-3, EN 55011 Class B, EN 55022 Class B, EN 61326-1,<br>EN 61000-3-2, EN 61000-3-3||EN 61000-6-3, EN 55011 Class B,<br>EN 55032 Class B, EN 61326-1,<br>EN 61000-3-2, EN 61000-3-3|EN 55011 Class B, EN 55022<br>Class B, EN 61000-3-2,<br>EN 61000-3-3|
|**Immunity**|EN 55024, EN 61326-1, EN 61000-6-1, EN 61000-6-2, SEMI F47||EN 55024, EN 61326-1, EN<br>61000-6-1, EN 61000-6-2, SEMI<br>F47|EN 61000-4-2, EN 61000-4-4,<br>EN 61000-4-5, SEMI F47|
|**General Protection/ Safety**|Protected against continuous short circuit, continuous overload, continuous open circuit.<br>IEC 60950-1: Class I Earthed, Output is SELV (Safety Extra Low Voltage),<br>Environmental Rating: Pollution Degree 2 IEC 60529 Ingress Protection Rating: IP20||||
|**Temperature8**|Storage: -40°C to + 85°C, Operation -40°C to +60°C full power, with linear derating to 75% power from 60 to 70°C (Convection cooling, no<br>forced air required). Operation upto 50% loadpermissible with sideways or front-side-upmountingorientation.||||
|**Humidity**|5 to 95 % RH Non-condensing, IEC 60068-2-2, IEC 60068-2-3||||
|**Vibration**|2.5g RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6||||
|**Shock**|10g RMS, three axes, 11mseconds for each axis - IEC 60068-2-27||||
|**Altitude**|0 to 3000 meters (0 to 10,000 feet)||||
1. In the event of a phase loss, the power supply will continue to operate normally. However, the resulting lower rectified RMS voltage can cause excessive heat build up, which may eventually cause the unit to shut down if maximum operating temperature is exceeded.
2. Input current ratings are specified with low AC 3-phase input, line conditions, worst case efficiency values and power factor spikes. Input current at nominal AC 3-phase input will typically be half these values.
3. Losses are heat dissipation in watts at full load, nominal line.
4. 24-28 Vdc adjustable guaranteed at full load.
5. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth scope and 50 Ohm resistor
6. All models are capable of paralleling. For redundant operation, please use external Redundancy module. Only the 40A uses active paralleling scheme. Please refer to user manual for details.
7. SDN 20 and SDN 40 are capable of delivering 150% load for approximately 4s before the unit will go to HICCUP mode. SDN 5 and 10 will maintain minimum 4s to deliver 150% load then drops to almost zero Vout. The output voltage will immediately drop to almost zero when load rises above 150%.
8. Contact Tech Support for operation -40°C.
**126**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions.
© December 2018
Power Supplies
## SDN-C Specifications (Three Phase)
**==> picture [538 x 379] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog Number<br>Description<br>SDN 5-24-480C SDN 10-24-480C SDN 20-24-480CD SDN 40-24-480C<br>Reliability<br>Telcordia<br>SR-332 Issue 2 >1,100,000 hours @ 380 Vac >1,400,000 hours @ 380 Vac >630,000 hours @ 380 Vac >600,000 hours @ 380 Vac<br>Method 1 Case 3 >900,000 hours @ 480 Vac >900,000 hours @ 480 Vac >630,000 hours @ 480 Vac >550,000 hours @ 480 Vac<br>@ 25°C<br>MTBF<br>Telcordia SR-332<br>>460,000 hours @ 380 Vac<br>Issue 2 >600,000 hours @ 380 Vac >910,000 hours @ 380 Vac >380,000 hours @ 380 Vac<br>>450,000 hours @ 480 Vac<br>Method 1 Case 3 >500,000 hours @ 480 Vac >600,000 hours @ 480 Vac >360,000 hours @ 480 Vac<br>SDN 20-24-480CR<br>@ 40°C<br>Visual: 3 status LEDs (Input, Output, Alarm)<br>Status Indicators<br>Relay: N.O. contact rated 200mA/50 Vdc, Signal Active when Vout> 18.5 Vdc +/-5%<br>Installation<br>Fusing -Input Input Branch fuse or circuit breaker should be provided by customer. See manual for details.<br>Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for<br> -Output wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.<br>Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.<br>16-10 AWG (1.5-6 mm [2] ) for solid conductors.<br>Input Screw Torque: 4.4 lb-in (~ 50 N-cm).<br>Connections [9,10 ] 7–6 AWG (10.6–13 mm [2] ) solid<br>(Screw Type) 16-10 AWG (1.5-6 mm [2] ) for solid conductors. or stranded conductors.<br>Output<br>Screw Torque: 7 lb-inch (~ 80 N-cm) Screw Torque: 15.6 lb-inch<br>(176 N-cm)<br>Above & Below 0.98 in (25 mm) 1.6 in (40 mm) 2.80 in (70mm)<br>-Free Space Left & Right 0.98in (25mm)<br>Front 0.59 in. (15 mm)<br>4.85 × 1.97 × 4.36 4.85 × 2.36 × 4.36 4.85 x 3.42 x 4.98 4.85 x 7.09 x 4.66<br>Dimensions - WxDxH in (mm) (123.0 × 50.0 × 110.0) (123.0 × 60.0 × 110.0) (123.0 x 87.0 x 127.0) (123.0 x 180.0 x 119.0)<br>Weight - lbs (kg) 1.2 (0.5) 1.5 (0.7) 2.7 (1.2) 5.3 (2.4)<br>General<br>Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. IP20 touch proof<br>Visual: 3 status LEDs (Input, Output, Alarm)<br>Status Indicators<br>Relay: N.O. contact rated 200mA/50 Vdc, Signal Active when Vout> 18.5 Vdc +/-5%<br>Warranty 5 Year Limited Warranty<br>**----- End of picture text -----**<br>
9. Screw terminals. Use only one copper wire per terminal. Non-ratcheting torque driver recommended.
10. SDN 40-24-480C only: Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND). Please refer to Signals Manual for details.
**127**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions. © December 2018
> Power Supplies ~~SAID~~
## SDN-C Series Dimensions
**==> picture [206 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 .97 in. W<br>[50.0 mm] 4.36 in. [110.8 mm] D<br>fr fi F 4<br>Power Supply<br>SDN5-24-100C<br>H<br>4.85 in. [123.3 mm]<br>**----- End of picture text -----**<br>
|**Catalog**<br>**Number**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|**SDN 5-24-100C**|4.85 (123.0)|1.97 (50.0)|4.36 (111.0)|
|**SDN 10-24-100C**|4.85 (123.0)|2.36 (60.0)|4.36 (111.0)|
|**SDN 16-12-100C**|4.85 (123.0)|2.36 (60.0)|4.36 (111.0)|
|**SDN 20-24-100C**|4.85 (123.0)|3.42 (87.0)|4.98 (127.0)|
|**SDN 5-24-480C**|4.85 (123.0)|1.97 (50.0)|4.36 (111.0)|
|**SDN 10-24-480C**<br>**SDN 20-24-480CD**|4.85 (123.0)<br>4.85 (123.0)|2.36 (60.0)<br>3.42 (87.0)|4.36 (111.0)<br>4.98 (127.0)|
|**SDN 20-24-480CD**<br>~~a~~|4.85 (123.0)<br>~~|~~|3.42 (87.0)<br>~~|~~|4.98 (127.0)|
## SDN 40-24-480C Dimensions
## SDN 40-24-100C Dimensions
**==> picture [490 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
W<br>D 7.09 in. [180.0 mm] W 4.81 in. [122.2 mm] D<br>S O L A<br>Power Supply Power Supply Power Supply<br>Signal D + 0.54 in (13.80 mm) 5.35 in. [136.0 mm] D + 0.54 in (13.80 mm)<br>Connector<br>5.51 in. (139.96 mm) H H 4.85 in. [123.3 mm]<br>**----- End of picture text -----**<br>
Voltage adjustment potentiometer located on top of power supply
|**Catalog**<br>**Number**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|**Dimensions - inches (mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|**SDN 40-24-100C**|4.85 (123.0)|7.09 (180.0)|4.81 (122.0)|
|**SDN 40-24-480C**<br>~~ee~~|4.85 (123.0)<br>~~ee~~|7.09 (180.0)<br>~~ee~~|4.66 (119.0)<br>~~ee~~|
SDN 40-24-100C and SDN 40-24-480C output signaling terminal block features: Shut Down, Power Good, Current Monitor, Current Balance, GND, and active current sharing through I_SHARE connectors (See Signals Manual for connection information).
**128**
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions.
© December 2018
Power Supplies
## SDN-C Series Mounting
SolaHD SDN-C power supplies are designed to be easily and reliably mounted to DIN rail. For applications requiring mounting the power supply directly to the panel, optional Panel Mount Adapter Brackets are available.
## DIN Rail Mounting
Snap on the DIN rail:
1. Tilt unit slightly backwards. Put it onto the DIN rail
3. Push downwards until stopped
**==> picture [83 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Detachment from DIN Rail:<br>**----- End of picture text -----**<br>
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer has locked
Alternative Panel Mount: Using the optional SDN-PMBRK3
accessory, the unit can be screw mounted to a panel.
## Panel Mounting
Panel mounting of SDN-C power supplies is simplified by using an optional Panel Mounting Bracket kit. Each kit comes with two brackets for modifying one power supply. Choose the appropriate bracket kit based on the power supply model in the tables below. Note that the Panel Mount bracket will add approximately 2-4mm in depth, compared to DIN rail mounting. Refer to the manual that comes with the bracket kit for detailed instructions on assembly and mounting.
## SDN-PMBRK3
**==> picture [512 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
ee Power Supply Panel Mount Dimensions - in. (mm)<br>SDN 16-12-100C Bracket DIN Bracket<br>1.93 (49.0)<br>SDN 5-24-100C<br>SDN 10-24-100C<br>SDN 20-24-100C<br>SDN 40-24-100C<br>SDN 10-24-480C M3X8 mm Top ViewTop View 3D View3D View<br>SDN 20-24-480CD Back View Phillips Screw<br>(41.9)<br>1.65<br>**----- End of picture text -----**<br>
**==> picture [510 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
SDN-PMBRK2<br>Dimensions - in. (mm)<br>Power Supply<br>LC SDN 5-24-480C (40.4)1.59 Iota<br>.70 (17.8)<br>po SDN 40-24-480C .43 (10.9) onc el<br>.23 (5.8) .51 (13.0)<br>(21.8).86 (4.6).18 .60 (15.2)<br>.60 1.30 1.80<br>(15.2) (33.0) (45.7)<br>.35<br>(8.9)<br>.08 (2.0).23 (5.8) (10.2).40 ad .26 (6.6) iy L | =| Gl= 2.16 (54.9)<br>.25 (6.4)<br>a<br>.52 (13.2) .52 (13.2)<br>**----- End of picture text -----**<br>
**129** cureson
Visit our website at **www.emerson.com** or contact Technical Services at **(800) 377-4384** with any questions. © December 2018
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →