SC-USB2
CONTROLLERS
- Manufacturer: BANNER ENGINEERING
- Product type: Controller Accessories
- SVHC: No SVHC (23-Jan-2024)
- Product Range: -
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 15.93 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Safet Controllers y ## Safety Controller Highlights - Intuitive icon-based drag-and-drop configuration via free PC software - 10 input, 26 input, and expandable models available - Communicates over industrial Ethernet - 80 virtual non-safe inputs - 256 virtual non-safe status outputs - EtherCAT expansion module is daisy chain and line topology ready with two RJ45 connectors - Export tag feature for easy PLC setup and integration - Live view and configure controller via network access feature Configurable Safety Controllers Pre-configured Safety Relay Modules ## Safety Relays and Controllers Industrial safety controllers and relays provide an interface between safety devices and the machines and processes those devices monitor for a complete and easy-to-use safety control solution. **==> picture [103 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> + + + more =<br>**----- End of picture text -----**<br> ## Expandable Safety Controller Expandable for Complex Safety applications where 3 or more safety relays are typically used - PC Configurable: Flexible and easy-to-use - Network Accessible: Configure and Live View via an Ethernet connection (Ethernet enabled XS26 and SC26 models only) - Safe Devices: Up to 394 with ISD - Safety Inputs: 26 (base unit) up to 154 - Independently controlled Safety Outputs: up to 68, 0.5A to 6A each - Convertible Safety Inputs: 8 (Base Unit) up to 40 - LCD Display for easy troubleshooting - Industrial Ethernet - In-Series Diagnostic (ISD) provides detailed status and performance data **==> picture [49 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> R<br>INDUSTRIAL ETHERNET<br>aaa<br>**----- End of picture text -----**<br> ## Hybrid Safety Controller plus 2 Safety Relays Flexible and cost effective solution for machines typically using 2 Safety Relays - PC Configurable: Flexible and easy-to-use - Safe Devices: Up to 70 with ISD - Safety Inputs: up to 14 using Automatic Terminal Optimization (ATO) R - **+ =** • Independently controlled Safety Outputs: 2, 6A each _INDUSTRIAL ETHERNET_ • Convertible Safety Inputs: 4 - Terminal LEDs for easy troubleshooting - Industrial Ethernet ## Safety Relays Cost effective for simple safety circuits - Pre-set Functionality: Configuration not required - Safety Inputs: 1 - Independently controlled Safety Outputs: 1, 4 to 7A ||**XS26**<br>**SC26**|**SC10**<br>**SR**<br>**IM**<br>**ES**<br>**UM**<br>**GM**<br>**SM**<br>**AT**<br>**Two-Hand**<br>**MMD**| |---|---|---| |**# of Input Terminals**|up to 154*<br>up to 26|10*<br>1<br>1<br>1<br>1<br>1<br>1<br>2 STB<br>2| |**# of Safe Devices**<br>**when using ISD**|394<br>1|70<br>1<br>1<br>1<br>1<br>1<br>1<br>2<br>1| |**Independently Controlled**<br>**Safe Outputs**|up to 68*<br>2|2<br>1<br>1<br>1<br>1<br>1<br>1<br>1<br>1| |**Max. Safety Output Rating**|0.5A,<br>6A* ea.<br>0.5A ea.|6A ea.<br>6A<br>6A<br>7A<br>7A<br>6A<br>6A<br>6A<br>6A| |**In-Series Diagnostics (ISD)**|**✓**|**✓**| |Beodrys|**✓**<br>**✓**<br>**✓**|| ||**✓**<br>**✓**<br>**✓**|| |Etheriet/IP|**✓**<br>**✓**<br>**✓**|| |—,<br>EtherCAT.*—|**✓**|| |**Network Access and View**|**✓**<br>**✓**|| |**E-Stop**|**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**|| |**Rope Pull**<br>~~3~~|**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>~~3~~<br>~~——_ o_o——_o_o~~<br>~~or~~|| |**Light Curtain/Scanner**<br>~~3~~|**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>~~3~~<br>~~——_ o_o ——_ o_o~~<br>~~or~~<br>~~OOO~~<br>~~OE~~<br>~~OOti‘(~~|| |**Light Curtain/Scanner**<br>**with EDM**<br>~~ell~~|**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>~~ell~~<br>~~OOO~~<br>~~OE~~<br>~~OOti‘(~~|| |**Gate Switch (Complimentary**<br>**Outputs ie. NC/NO)**|**✓**<br>**✓**<br>**✓**<br>**✓**|| |**Gate Switch**<br>**(Similar Outputs ie. NC/NC)**|**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**<br>**✓**|| |**Safety Mat Monitoring**<br>~~a,~~|**✓**<br>**✓**<br>**✓**<br>**✓**<br>~~a,~~<br>~~OE~~<br>dhdhlhlC<br>~~Lh)~~|| |**Two-Hand Control**<br>~~a,~~|**✓**<br>**✓**<br>**✓**<br>**✓**<br>~~a,~~<br>~~OE~~<br>dhdhlhlC<br>~~Lh)~~|| |**Muting**|**✓**<br>**✓**<br>**✓**<br>**✓**|| |**ON/OFF Delay**|**✓**<br>**✓**<br>**✓**|| NOTE: Up to Cat. 4 PL e. per EN ISO 13849-1; SIL 3 per IEC 61508 and IEC 62061. See www.bannerengineering.com for additional information. *Expandable input and output modules available www.bannerengineering.com | 1-888-373-6767 ## Build System and Select Equipment Start using the free software today. Go to bannerengineering.com/safetycontrol The feature-rich SC10 and SC/XS26 safety controller software provides a seamless user interface for setting up and managing safety systems. The software features an intuitive icon-based, drag-and-drop user interface to reduce the learning curve and speed up commissioning. - Complex configurations made easy - Simulate configurations before implementation - Auto configure industrial Ethernet for remote monitoring and diagnostics ## 1. Choose controller ## 4. Select safety device properties **==> picture [186 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> 6. Configure your system in minutes<br>**----- End of picture text -----**<br> **==> picture [1079 x 554] intentionally omitted <==** **----- Start of picture text -----**<br> Emergency Stop Properties<br>Please select a safety controller: Assorted Function Block<br>Name Cd M0:ES1 View Menus<br>Simulation View Logic Block<br>XS26/SC26 Series O SC10 Series Dual-Channel 4 terminal a —<br>Info Module Summary Equipment Functional View Wiring Diagram Ladder Logic Industrial Ethernet Configuration Summary Simulation Mode<br>LJ IN15IN11ESCIN1IN7OK ns Power / FaultUSBInputsSO1SO2IN12IN16IN2IN8 IN13IN17IN3IN9 IN14IN18IN10IN4 SO1aIO5IO1IN5SC26-2deSO1bIO6IO2IN6 SO2a24VIO7IO3 SO2bIO8IO40V IO1IN5IN1IN9Power / FaultTx / RxInputsIN10IO2 os IN6IN2XS16siIN11IO3IN7IN3 IN12IO4IN8IN4 13614331 Power / FaultTx / RxSO1SO2 ss 1444 XS2ro23625332 2454 SO1a24VPower / FaultTx / RxSO1SO2SO1b24VXS2soSO2a0V SO2b0V 2) M0:SLC FRONT 2 o a o<br>Simulator M0:MUTE M0:SO1<br>IN<br>M4:XS26-2de IO1 IN3 IO2 IN4 MP1 IN<br>a Nl init Enable Startup Test Cr : M0:GATE FRONT M a “ M1 i D- A3 ii<br>Simultaneity Simultaneous M0:GATE BACK<br>Debounce Times Simulation Speed 100 %<br>Continue Close to open 0 sec 6 ms Step Interval 4 ms<br>Open to close 0 sec 50 ms M1:GATE LEFT<br>5 Basic Delete OK Cancel M1:SAFE MAT A2<br>a Le<br>Properties M1:GATE RIGHT<br>© |<br>NameName SLC FRONTValue M0:E-STOP FNT M0:SO2A<br>5. Add virtual non-safety inputs Module M0 IN IN<br>Circuit Type Dual-Channel PNP M0:E-STOP BCK A1 LR LR1<br>Add Equipment Terminals M0<br>Delete Edit M0:E STOP SIDE-STOP BCK<br>Safety Input<br>= OS Add Non-Safety Inputs Virtual ManualReset Virtual On-Off Virtual Mute 2 Enable || Virtual Cancel Off @ Delay VMR1 = ) M0:SO2B<br>modules Virtual Non-Safety Inputs TCIN IN<br>= a Add safety fa t T1<br>devices Reference M0:2 HAND CTL<br>= af a<br>= Info<br>(es) Cancel<br>Module Summary Inputs Simple Split Output<br>and Configuration Drag-and-Drop<br>Checklist Connections<br>a Paes<br>Emergency Stop Gate Switch |[ Optical Sensor 4 Two-Hand Control |/88 Wiring diagram in live mode Ladder logic Industrial network integration<br>1/1<br>© Enabling DeviceSafety Mat Muting Sensor PairProtective Stop External DeviceBypass SwitchMonitoringBypass SwitchMonitoring Adjustable ValveRope PullMonitorRope PullMonitorMonitor re ) Module SummaryCheck List (0)Properties DOES IN15IN11ESCIN1IN7OK Power / FaultUSBInputsSO1SO2IN12IN16IN2IN8 IN13IN17IN3IN9 The configuration isvalid and can be sentto the Controller IN14IN18IN10IN4 SO1aIO5IO1IN5SC26-2deSO1bIO6IO2IN6 SO2a24VIO7IO3 SO2bIO8IO40V IO1IN5IN9IN1Power / FaultTx / RxInputsIN10IO2IN6IN2XS16siIN11IO3IN7IN3 IN12IO4IN8IN4 IO1IN1IN5IN9Power / FaultTx / RxInputsIN10IO2IN2IN6XS16siIN11IO3IN3IN7 IN12IO4IN4IN8 IO1IN9IN1IN5Power / FaultTx / RxInputsIN10IO2IN2IN6XS16siIN11IO3IN3IN7 IN12IO4IN4IN8 SO1aSO3a24VPower / FaultTx / RxSO1SO2SO3SO4SO1bSO3b24VXS4soSO2aSO4a0V SO2bSO4b0V HE Equipment SO1bSO1a24V0V+IO8+IO7SO2aSO2b+IO1+IO2+IO3+IO4IN2IN2IN3IN4IN2IN6Functional View s 24V dc Power a A M0:STAT1M0:STAT2M0:SO2AM0:SO2BM0:THC1M0:GS1M0:OS1M0:MSP1M0SO1M0:ES1M0:MR1Wiring Diagram U0 B00 Ladder Logic Industrial Ethernet+IO5+IO6IN10IN11IN12IN13IN14IN15IN16IN17IN18IN7IN8IN9 Terminals available for all circuitConfiguration Summarytypes Live Mode IN15IN11ESCIN1IN7OK Power / FaultUSBInputsSO1SO2IN16IN12IN2IN8 Module Position: 0 IN17IN13IN3IN9 IN18IN14IN10IN4 SO1aIO5IO1IN5XS26-2deSO1bIO6IO2IN6 SO2a24VIO7IO3 SO2bIO8IO40V ; = Module SummaryCheck List (0)PropertiesIN15IN11ESCIN1IN7OK Power / FaultUSBInputsSO1SO2IN12IN16IN2IN8 IN13IN17IN3IN9 IN10IN14IN18IN4 The configuration isvalid and can be sentto the Controller SO1aIO1IO5IN5SC26-2deSO1bIO2IO6IN6 SO2a24VIO3IO7 e SO2bIO4IO80V IO1IN5IN9IN1Power / FaultTx / RxInputsIN10IO2IN6IN2XS16siIN11IO3IN7IN3 IN12IO4IN8IN4 IO1IN1IN5IN9Power / FaultTx / RxInputs u IN10IO2IN2IN6XS16siIN11IO3IN3IN7 IN12IO4IN4IN8 IO1IN5IN1IN9Power / FaultTx / RxInputsIN10IO2IN6IN2XS16siIN11IO3IN7IN3 IN12IO4IN8IN4 SO1aSO3a24VPower / FaultTx / RxSO1SO2SO3SO4SO1bSO3b24VXS4soSO2aSO4a0V SO2bSO4b0V SO1aSO3a24VPower Tx / RxSO1SO2SO3SO4SO1bSO3b24VXSSOSO0 Equipment Functional View Wiring Diagram am Ladder Logic e +24VIndustrial EthernetM0:GS4M1:GS3M0:ES5CR01CR05 T M2:MSP1(A/B)M2:MSP2(A/B)M2:OS1M0:GS3M1:GS2M0:ES4 T Configuration SummaryM0:MR1M0:GS2M1:GS5M0:ES3CR0130s30s M0:GS1M0:ES2 M0:OS1M0:ES1 M0:SO1M0:SO2M0:SO1M0:SO2 BBAA [LR1]CR01CR02CR03CR04[A1][A3][A4] 0V 001002003004005006007008 ee<br>NOTES:Symbols are shown using the Stop state signal convention except for Emergency Stop, Rope Pull, Gate Switch, andSafety Mat inputs. Module: M0:XS26-2de CR04 CR03 CR02 CR05[A2] 009<br>24V<br>24V<br>24V<br>24V<br>24V<br>24V<br>**----- End of picture text -----**<br> **==> picture [96 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> 2. Equipment view<br>**----- End of picture text -----**<br> ## 3. Add safety devices **==> picture [248 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> Add Equipment<br>Safety Input a Paes<br>Non-Safety Inputs Emergency Stop Gate Switch |[ Optical Sensor 4 Two-Hand Control |/88<br>=> ©<br>Virtual Non-Safety Inputs<br>Reference Safety Mat Protective Stop Monitoring<br>Info re )<br>Enabling DeviceSafety Mat Muting Sensor PairProtective Stop External DeviceBypass SwitchMonitoringBypass SwitchMonitoring Adjustable ValveRope PullMonitorRope PullMonitorMonitor<br>Cancel<br>**----- End of picture text -----**<br> www.bannerengineering.com | 1-888-373-6767 • 2 x 6A independently controlled relays (RO1 & RO2) • 3 NO sets of contacts each ## XS26 Expandable Safety Controller ## SC10 Safety Controller - Optional display screen allows local diagnostics for efficient troubleshooting - Up to eight expansion I/O modules can be added as automation requirements grow or change - Choose from six expansion module models with a variety of safety inputs, solid-state safety outputs and safety relay outputs - Controller and input modules allow safety inputs to be converted to status outputs for efficient terminal use - Fast programming and swapout using the SC-XM3 memory card (see next page) ## Automatic Terminal Optimization (ATO) Allows for an increase from 10 to 14 inputs - Network accessible: configure and live view via an Ethernet connection (Ethernet enabled XS26 and SC26 models only) **==> picture [539 x 204] intentionally omitted <==** **----- Start of picture text -----**<br> XS26 Safety<br>Controller<br>Network<br>Ss<br>communication<br>—_ • Base Controller allows eight of<br>Ethernet Portvia optional the 26 inputs to be configured as outputs for efficient terminal use<br>ae<br>• Two independent pairs of safe<br>PC communication outputs at 0.5A each<br>via Micro USB Port ann Sas a | ‘XSeCAT| = xsiési] ——-XS4so.<br>THPower/Faut |B Power! Fault | power /Fauit | Bt Power /Fauit \ Gezeeee • In-Series Diagnostic (ISD)<br>Status LEDs Bose Sacre lac. )6=| (lle Su provides detailed status and<br>Eso lmljerror || lm s02 performance data<br>Onboard ; ‘<br>Interface SC26 Safety<br>Push Buttons<br>| Controller<br>Optional<br>Display • Base Controller allows eight of<br>the 26 inputs to be configured as<br>outputs for efficient terminal use<br>**----- End of picture text -----**<br> - Two independent pairs of safe outputs at 0.5A each **==> picture [162 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Base Controller (shown with LCD and Ethernet)<br>**----- End of picture text -----**<br> - Models available with optional Ethernet and display **==> picture [292 x 230] intentionally omitted <==** **----- Start of picture text -----**<br> “oo +IO2IN2<br>M0:ES1<br>IN1<br>+IO1<br>IN4<br>M0:OS1<br>< fS IN3 A<br>O IN6 RO1 & RO2 LEDs<br>+IO4<br>M0:ES1<br>IN5 Power LED<br>O_| +IO3<br>24V<br>24V dc Power<br>0V 6 Safe Inputs<br>om” +IO1 & LEDs<br>Qo +IO2 Convertible terminals<br>CyCy +IO3+IO4 available (shared useremaining) 4 Safe Inputs & LEDs or 4 Non-safe<br>Inputs & LEDs<br>Wire Diagram View for 10 Inputs without ATO<br>Micro USB & LED<br>M0:ES1<br>External Terminal Blocks (ETB)**<br>M0:ES1<br>M0:OS1 +IO1* ETB1 M0:GS1 Ethernet Port<br>OFF<br>OFF<br>**----- End of picture text -----**<br> **==> picture [174 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Wire Diagram View for 10 Inputs without ATO<br>**----- End of picture text -----**<br> **==> picture [228 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> IN2<br>+IO2*<br>M0:ES1<br>IN1 External Terminal Blocks (ETB)**<br>+IO1* M0:ES1<br>IN4 M0:OS1 +IO1* ETB1 M0:GS1<br>H IN3 S M0:GS2<br>IN6<br>+IO2* M0:ES1<br>M0:GS1<br>IN5 +IO2* ETB2 M0:GS1<br>+IO1*<br>M0:GS2<br>+IO4<br>**ETBs are not included with SC10 controller<br>rch +IO2*<br>M0:GS2<br>Ch——— +IO3*<br>om +IO1*<br>24V<br>24V dc Power<br>Comm 0V<br>Wire Diagram View for 14 Inputs with ATO<br>OFF<br>OFF<br>**----- End of picture text -----**<br> **==> picture [139 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> SC-XM3<br>Fast Programming and Swapout<br>**----- End of picture text -----**<br> **==> picture [300 x 51] intentionally omitted <==** **----- Start of picture text -----**<br> Store SC-XM3 • Backup copy of configuration,<br>memory card<br>"ENG. a password, network settings<br>directly on SC10<br>or XS26 BONG)SoaN: © a) ‘heae<br>ANNE => • Download configuration without a<br>PC; Save time during panel build<br>**----- End of picture text -----**<br> - Fast swapout to minimize downtime at swapout **==> picture [281 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> In-Series Diagnostics (ISD) makes it easy to access diagnostic data<br>from devices in a safety system without special equipment or<br>designated cabling. Users can troubleshoot machine safety<br>systems, prevent system faults, and reduce equipment downtime.<br>This innovative, next generation technology is exclusive to safety devices from<br>Banner Engineering. For more information go to www.bannerengineering.com/isd<br>**----- End of picture text -----**<br> www.bannerengineering.com | 1-888-373-6767 **==> picture [571 x 413] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---| |Independently|Independently| |Industrial|Inputs/|Controlled|Max. Safety|Industrial|Inputs/|Controlled|Max. Safety| |Model*|Description|Ethernet|Convertible|Safe Outputs|Output Rating|Model*|Description|Ethernet|Convertible|Safe Outputs|Output Rating| |XS26-2d|XS4so| |XS26-2de| |Base Controller|✓|26/8|2|0.5A PNP @24 V DC|Safety Output|–|2|0.5A PNP @24 V DC| |with LCD|Module| |i| |XS26-2|XS1ro| |XS26-2e| |Base|✓|26/8|2|0.5A PNP|A|Safety Relay|–|1|6A; 2 NO,| |Controller|@24 V DC|Output|1 NC aux| |Module| |:| |E|oa| |XS26-ISDd|Base|XS2ro| |Controller|A|Safety| |✓|26/8|2|0.5A PNP @24 V DC|Relay Output|–|2|6A; 2 NO, 1 NC aux| |Module| |ia|6-56|z| |XSeCAT|SC26-2d| |SC26-2de| |=|EtherCAT| |Expansion|EtherCAT|–|–|–|Base|0.5A PNP| |Module|=|Controller|✓|26/8|2|@24 V DC| |with LCD| |-| |=| |XS8si| |SC26-2| |Safety| |Input|8/2|–|–|SC26-2e| |Module| |Base|0.5A PNP| |✓|26/8|2| |Controller|@24 V DC| |XS16si| |Safety| |Input|16/4|–|–|SC10-2roe| |Module|Base| |Controller| |✓|10/4|2|6A; 3 NO| |XS2so| |Safety Output|–|1|0.75A PNP| |@24 V DC| |Module| **----- End of picture text -----**<br> **==> picture [96 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> *Models operate at 24 V DC +/- 20%.<br>**----- End of picture text -----**<br> ## Specifications **==> picture [357 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> 45 mm<br>aes 45 mm 22.5 mm 22.5 mm<br>110 mm 115 mm<br>128 mm<br>100 mm<br>SC-USB2 SC-XM3 SC-XMP2<br>USB Cable Memory Card SC-XM2/3 Configuration Tool<br>**----- End of picture text -----**<br> ## Accessories Additional accessories are available at bannerengineering.com Start using the free software today. Go to bannerengineering.com/safetycontroller ## Banner Engineering Corp. 9714 10th Avenue North • Minneapolis, MN 55441 • 1-888-373-6767 • www.bannerengineering.com © 2023 Banner Engineering Corp. Minneapolis, MN USA PN 174393 rev. H
Updated at April 22, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →