S15C-U-MQ
Signal Converter, Voltage, Modbus, 1 Channels, 1.5 %, 30 VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
- Accuracy %: 1.5%
- Product Range: S15C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Voltage
- Signal Conditioner Output: Modbus
- Signal Conditioner Mounting: Cable Mount
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 103.86 € |
| Current stock | 10+ |
| Lead time | 30 days |
## S15C Analog Voltage to Modbus Converter ## Datasheet - - - - Compact analog voltage to Modbus converter that connects to a voltage source (0 V to 10 V) and outputs the value to Modbus registers - Rugged over-molded design meets IP65, IP67, and IP68 Connects directly to a sensor or anywhere in-line for ease of use ## Models **==> picture [498 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> Housing Function Female Male Connector<br>S15 C - U - M Q<br>C = Converter U = Analog Voltage M = Modbus Q = Integral M12 quick disconnect<br>**----- End of picture text -----**<br> ## Configuration Instructions ## Sensor Configuration Software The Sensor Configuration Software offers an easy way to manage converter Modbus settings, retrieve data, and visually show converter data. The Sensor Configuration Software runs on any Windows machine and uses an adapter cable (BWA-UCT-900, p/n 19970) to connect the converter to the computer. Download the most recent version of the Sensor Configuration Software from the Banner Engineering website: https:// info.bannerengineering.com/cs/groups/public/documents/software/b_3128586.exe. ## Modbus Configuration |**Modbus Register**<br>**Address**|**Description**|**I/O Range**|**Comments**|**Default**|**Access**| |---|---|---|---|---|---| |**IO Data Out**|||||| |40001|Analog Data output|0..10000|Voltage (V) = Register Value / 1000|0-10|RO| |40002|Alarm State for IO 1 based on Min and Max<br>thresholds defined in Analog In Min Value () and<br>Analog In Max Value()|0..1|0 = Within threshold range<br>1 = Out of threshold range|-|RO| |40003|Status of program|0..2|STATUS_ERROR_TYPE_NO_ERROR = 0<br>STATUS_ERROR_TYPE_BELOW_MIN = 1<br>STATUS_ERROR_TYPE_ABOVE_MAX = 2|-|RO| |**Input_ADC_Config**|||||| |41201|Sample interval time|0.65535|0 = Disabled<br>1 = 10 ms<br>2..65535 = 5 ms increments|1|RW| |**FilterConfig**|||||| |41202|Takes current ADC value and the last 2 ADC<br>readings and takes the median of the 3 values.|0..1|0 = Median Filter Disabled<br>1 = Median Filter Enabled|0|RW| |**Minimum Value**|||||| |41204|Minimum analog value for data read|0..9|Must be less than maximum|0|RW| |**Maximum Value**|||||| |41205|Max analog value for data read|1..10|Must be greater than the minimum|10|RW| |**COMs Settings**|||||| Original Document 223062 Rev. D 17 June 2022 223062 S15C Analog Voltage to Modbus Converter |**Modbus Register**<br>**Address**|**Description**|**I/O Range**|**Comments**|**Default**|**Access**| |---|---|---|---|---|---| |46101<br>|Baud Rate<br> <br> <br>|0 = 9.6k<br>1 = 19.2k<br>2 = 38.4k|0 = 9.6k<br>1 = 19.2k<br>2 = 38.4k|1|RW| |46102<br>|Parity<br> <br> <br>|0 = None<br>1 = Odd<br>2 = Even|0 = None<br>1 = Odd<br>2 = Even|0|RW| |46103<br>|Slave Address<br>|1..247|1 to 247|1|RW| ## Wiring Diagrams |0 V to 10 V Analog Sensor<br>**Input:**|0 V to 10 V Analog Sensor<br>**Input:**|||RS485 Modbus<br>**Output:**|RS485 Modbus<br>**Output:**| |---|---|---|---|---|---| ||||||| |**Male (Gateway)**|**Female (Sensor)**||**Pin**||**Wire Color**| |**1**<br>**4**<br>**3**<br>**2**|**2**<br>**3**<br>**4**<br>**1**||1||Brown| ||||2||White| ||||3||Blue| ||||4||Black| **Important:** If using a cable to connect the converter to an analog sensor, use of a shielded M12 cable is recommended, with the shield tied to pin 3. ## Connecting 0 V to 10 V Analog Sensors |Ground<br>10 V DC to 30 V DC<br>0 V to 10 V in<br>**Input:**|1(bn)<br>2(wh)<br>4(bk)<br>3(bu)<br>10 V DC to 30 V DC<br>RS485/D1/B/+<br>RS485/D0/A/-<br>Ground<br>1<br>2<br>4<br>3<br>**Output:**| |---|---| ## Status Indicators ## **Power LED Indicator (Green)** - Solid Green = Power On - Off = Power Off ## **Modbus Communication LED Indicator (Amber)** - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 seconds - Off = Modbus communications are not present P/N 223062 Rev. D 2 www.bannerengineering.com - Tel: + 1 888 373 6767 S15C Analog Voltage to Modbus Converter ## Specifications **Supply Voltage** 10 V DC to 30 V DC at 50 mA maximum **Power Pass-Through Current** 4 A maximum **Supply Protection Circuitry** Protected against reverse polarity and transient voltages **Leakage Current Immunity** 400 µA ## **Resolution** 12-bits **Accuracy** 1.5% of full scale ## **Indicators** Green power Amber Modbus communications **Connections** Integral male/female 4-pin M12 quick disconnect **Construction** Coupling Material: Nickel-plated brass Connector Body: PVC translucent black ## **Vibration and Mechanical Shock** Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) ## **Environmental Rating** IP65, IP67, IP68 NEMA/UL Type 1 ## **Operating Conditions** **Temperature:** –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) **Storage Temperature:** –40 °C to +80 °C (–40 °F to +176 °F) ## **Required Overcurrent Protection** **WARNING:** Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |**Supply Wiring (AWG)**|**Required Overcurrent Protection (Amps)**| |---|---| |20|5.0| |22|3.0| |24|2.0| |26|1.0| |28|0.8| |30|0.5| **Certifications** **Banner Engineering Europe** Park Lane, Culliganlaan 2F bus 3, 1831 Diegem, BELGIUM **Turck Banner LTD** Blenheim House, Blenheim Court, Wickford, Essex SS11 8YT, Great Britain ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [415 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 57.8<br>[2.27]<br>27.9<br>[1.1]<br>15.0<br>[0.59]<br>M12 X 1 - 6H<br>M12 X 1 - 6g<br>**----- End of picture text -----**<br> P/N 223062 Rev. D www.bannerengineering.com - Tel: + 1 888 373 6767 3 S15C Analog Voltage to Modbus Converter ## Accessories ## Cordsets |**4-Pin Threaded M12 Cordsets—Double Ended**|**4-Pin Threaded M12 Cordsets—Double Ended**|**4-Pin Threaded M12 Cordsets—Double Ended**|**4-Pin Threaded M12 Cordsets—Double Ended**||| |---|---|---|---|---|---| |**Model**|**Length**|**Style**|**Dimensio**|**ns**|**Pinout**| |**MQDEC-401SS**|0.31 m (1 ft)|Male Straight/<br>Female Straight|40 Typ.<br>[1.58"]<br>ø 14.5 [0.57"]<br>M12 x 1<br>44 Typ.<br>[1.73"]<br>ø 14.5 [0.57"]<br>M12 x 1||Female<br>**2**<br>**3**<br>**4**<br>**1**<br>Male<br>**1**<br>**4**<br>**3**<br>**2**<br>1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black| |**MQDEC-403SS**|0.91 m (2.99 ft)||||| |**MQDEC-406SS**|1.83 m (6 ft)||||| |**MQDEC-412SS**|3.66 m (12 ft)||||| |**MQDEC-420SS**|6.10 m (20 ft)||||| |**MQDEC-430SS**|9.14 m (30.2 ft)||||| |**MQDEC-450SS**|15.2 m (49.9 ft)||||| ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. **THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.** This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. **IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.** Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## FCC Part 15 This device complies with Part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. ## Industry Canada This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. © Banner Engineering Corp. All rights reserved
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →