S15C-PS150C-MQ
Signal Converter, Analog Current Pressure Sensor, Modbus, 1 Channels, 1.5 %, 30 VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
- Accuracy %: 1.5%
- Product Range: S15C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Analog Current Pressure Sensor
- Signal Conditioner Output: Modbus
- Signal Conditioner Mounting: Cable Mount
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 203.9 € |
| Current stock | 10+ |
| Lead time | 30 days |
PGP Pressure Sensor with S15C Modbus Converter ## Datasheet - _Ceramic PGP Stainless PGP_ • Includes a pressure sensor and an S15C Analog to Modbus Converter - • Pre-configured for use with the specific pressure sensor - _S15C Converter_ ## Models **==> picture [500 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Model Number Pressure Range Measuring Cell<br>S15C-PS15SS-MQ 0 PSIG to 15 PSIG Stainless Steel<br>S15C-PS50SS-MQ 0 PSIG to 50 PSIG Stainless Steel<br>S15C-PS100SS-MQ 0 PSIG to 100 PSIG Stainless Steel<br>S15C-PS150C-MQ [(1)] 0 PSIG to 150 PSIG Ceramic<br>S15C-PS150SS-MQ 0 PSIG to 150 PSIG Stainless Steel<br>S15C-PS3000SS-MQ 0 PSIG to 3000 PSIG Stainless Steel<br>S15C-PS5000SS-MQ 0 PSIG to 5000 PSIG Stainless Steel<br>**----- End of picture text -----**<br> ## Configuration Instructions ## Sensor Configuration Software The Sensor Configuration Software offers an easy way to manage converter Modbus settings, retrieve data, and visually show converter da ta. The Sensor Configuration Software runs on any Windows machine and uses an adapter cable (BWA-UCT-900, p/n 19970) to connect the converter to the computer. Download the most recent version of the Sensor Configuration Software from the Banner Engineering website: https:// info.bannerengineering.com/cs/groups/public/documents/software/b_3128586.exe. ## Modbus Configuration **==> picture [500 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> Modbus Register Address Description I/O Range Comments Default [(2)] Access<br>IO Data Out<br>Pressure (PSI) = Register Value / 100 1500<br>Pressure (PSI) = Register Value / 100 5000<br>40001 Pressure Data output 032768 Pressure (PSI) = Register Value / 100Pressure (PSI) = Register Value / 100 1000015000 RO<br>Pressure (PSI) = Register Value / 1 3000<br>Pressure (PSI) = Register Value / 1 5000<br>Alarm State for IO 1 based on Min and Max<br>40002 thresholds defined in Analog In Min Value () 0...1 0 = Within threshold range RO<br>1 = Out of threshold range<br>and Analog In Max Value()<br>Continued on page 2<br>**----- End of picture text -----**<br> (1) Ceramic measuring cell for compressed air applications. (2) Depending on model selected. Original Instructions August 11, 2023 © Banner Engineering Corp. p/n: 236015 Rev. B 236015 PGP Pressure Sensor with S15C Modbus Converter **==> picture [500 x 375] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 1<br>Modbus Register Address Description I/O Range Comments Default Access<br>STATUS_ERROR_TYPE_NO_ERROR = 0<br>40003 Status of program 0...2 STATUS_ERROR_TYPE_BELOW_MIN = 1 RO<br>STATUS_ERROR_TYPE_ABOVE_MAX = 2<br>Input_ADC_Config<br>0 = Disabled<br>41201 Sample interval time 0...65535 1 = 10 ms 1 RW<br>2...65535 = 5 ms increments<br>FilterConfig<br>Takes current ADC value and the last ADC<br>0 = Median Filter Disabled<br>41202 reading and takes the median of the val 0...1 1 = Median Filter Enabled 0 RW<br>ues.<br>Minimum Value<br>0...14 PSI<br>0...49 PSI<br>0...99 PSI<br>41204 Minimum pressure value for data read 0...149 PSI Must be less than maximum 0 PSI RW<br>0...149 PSI<br>0...2999 PSI<br>0...4999 PSI<br>Maximum Value<br>1...15 PSI 15 PSI<br>1...50 PSI 50 PSI<br>1...100 PSI 100 PSI<br>41205 Maximum pressure value for data read 1...150 PSI Must be greater than the minimum 150 PSI RW<br>1...150 PSI 150 PSI<br>1...3000 PSI 3000 PSI<br>1...5000 PSI 5000 PSI<br>COMs Settings<br>0 = 9.6k 0 = 9.6k<br>46101 Baud Rate 1 = 19.2k 1 = 19.2k 1 RW<br>2 = 38.4k 2 = 38.4k<br>0 = None 0 = None<br>46102 Parity 1 = Odd 1 = Odd 0 RW<br>2 = Even 2 = Even<br>46103 Slave Address 1...247 1 to 247 1 RW<br>**----- End of picture text -----**<br> ## Wiring ## S15C Wiring **==> picture [500 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> Input: Output:<br>2 wire or 3 wire<br>4 mA to 20 mA Analog Sensor RS485 Modbus<br>Male (Gateway) Female (Sensor) Pin Wire Color<br>1 1 Brown<br>2 2 2 White<br>1<br>3 Blue<br>4 3<br>3 4 4 Black<br>**----- End of picture text -----**<br> IMPORTANT: If using a cable to connect the converter to an analog sensor, use of a shielded M12 cable is recom mended, with the shield tied to pin 3. page 2 August 11, 2023 © Banner Engineering Corp. All rights reserved. PGP Pressure Sensor with S15C Modbus Converter ## Connecting 2-wire 4 mA to 20 mA Sensors **Input: Output:** 1 1 (bn) Loop + 12 V DC to 30 V DC 2 2 (wh) Loop - RS485/D1/B/+ 4 4 (bk) RS485/D0/A/3 3 (bu) Ground ## PGP Wiring **==> picture [500 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> 4-pin M12 Male QD Pin Description<br>1 Supply +<br>1<br>2 2 Output<br>4<br>3 Not used/no connection<br>3<br>4 Not used/no connection<br>**----- End of picture text -----**<br> ## Status Indicators Power LED Indicator (Green) - Solid Green = Power On - Off = Power Off Modbus Communication LED Indicator (Amber) - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 sec onds - Off = Modbus communications are not present ## Specifications ## S15C Specifications Supply Voltage 12 V DC to 30 V DC at 50 mA maximum Power Pass-Through Current 4 A maximum Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Resolution 12-bits Accuracy 1.5% of full scale Internal Resistance 100 ohms ## Indicators Green power Amber Modbus communications ## Connections Integral male/female 4pin M12 quickdisconnect connector Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068227 requirements (Shock: 15G 11 ms dura tion, half sine wave) ## Environmental Rating IP65, IP67, IP68 NEMA/UL Type 1 ## Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM **==> picture [137 x 54] intentionally omitted <==** August 11, 2023 page 3 © Banner Engineering Corp. All rights reserved. PGP Pressure Sensor with S15C Modbus Converter ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in ac cordance with local and national electri cal codes and regulations. Overcurrent protection is required to be provided by end prod uct application per the supplied table. **==> picture [208 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> Product Identification Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. ## Ceramic Pressure Sensor S pecifications Supply Voltage 9 to 30 V DC Output 4 to 20mA, 2-wire Loop Power Connections Electrical: M12x1 4pin Male Process: 1/4"-18 Male NPT Ambient Temperature –20 °C to +70 °C (–4 °F to +158 °F) Compensated Temperature –20 °C to +70 °C (–4 °F to +158 °F) Storage Temperature –20 °C to +70 °C (–4 °F to +158 °F) Enclosure Rating IP65 Accuracy ±1% of Full Scale Zero/Span Tolerance ±1% of Full Scale Long Term Stability ±1%/year Permissible Over-pressure 1.5x Full Scale Burst Pressure 2x Full Scale Construction Housing: #304SS, Copper, Aluminium Wetted Parts: # 316L Stainless Steel, Ceramic Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM ## Stainless Pressure Sensor Specifications Supply Voltage 9 to 30 V DC Output 4 to 20mA, 2-wire Loop Power Connections Electrical: M12x1 4pin Male Process: 1/4"-18 Male NPT Ambient Temperature –40 °C to +85 °C (–40 °F to +185 °F) Compensated Temperature –10 °C to +70 °C (+14 °F to +158 °F ) Storage Temperature –45 °C to +85 °C (–49 °F to +185 °F) Enclosure Rating IP67 Accuracy ±0.5% of Full Scale Zero/Span Tolerance ±0.5% of Full Scale Long Term Stability ±0.5%/year Permissible Over-pressure 2.5x Full Scale Burst Pressure 4x Full Scale Construction Housing: #304SS, Copper, Aluminium Wetted Parts: #316L Stainless Steel Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM ## FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses August 11, 2023 page 4 © Banner Engineering Corp. All rights reserved. PGP Pressure Sensor with S15C Modbus Converter and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions ## S15C Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [293 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> 57.8<br>[2.27]<br>27.9<br>[1.1]<br>15.0<br>[0.59]<br>M12 X 1 - 6g M12 X 1 - 6H<br>**----- End of picture text -----**<br> ## Ceramic Pressure Sensor Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [371 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> Ceramic model<br>56.9±1.0<br>[2.24±0.04]<br>10.0 14.5<br>3X 25.0 [0.39] [0.57] Ø3.0<br>3 2 [0.98] [0.12]<br>Ø24.5<br>[0.96]<br>4 1<br>Ø27.6<br>M12 x 1.0 [1.09]<br>**----- End of picture text -----**<br> ## Stainless Pressure Sensor Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [373 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> Stainless steel model<br>62.9±1.0<br>[2.47±0.04]<br>10.0 15.5<br>3 2 3X[0.98]25.0 [0.39] [0.61] Ø3.0[0.12]<br>Ø24.5<br>[0.96]<br>4 1 Ø27.5<br>M12 x 1.0 [1.08]<br>**----- End of picture text -----**<br> August 11, 2023 page 5 © Banner Engineering Corp. All rights reserved. PGP Pressure Sensor with S15C Modbus Converter ## Accessories ## Cordsets **==> picture [500 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> 4Pin Threaded M12 Cordsets—Double Ended<br>Model Length Style Dimensions Pinout<br>MQDEC401SS 0.31 m (1 ft) Female<br>MQDEC-403SS 0.91 m (2.99 ft)<br>2<br>40 Typ.<br>MQDEC-406SS 1.83 m (6 ft) [1.58"] 1<br>MQDEC412SS 3.66 m (12 ft) 4 3<br>MQDEC420SS 6.10 m (20 ft) M12 x 1<br>MQDEC430SS 9.14 m (30.2 ft) Male Straight/Female ø 14.5 [0.57"] Male<br>Straight 44 Typ.<br>[1.73"] 1<br>2<br>4<br>MQDEC450SS 15.2 m (49.9 ft) M12 x 1 3<br>ø 14.5 [0.57"] 1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BAN NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan guage. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 6 August 11, 2023 © Banner Engineering Corp. All rights reserved.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →