S15C-MVT-KQ
CONVERTERS
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 103.86 € |
| Current stock | 10+ |
| Lead time | 30 days |
## S15C Modbus Master to IO-Link Device Converter for Vibration and Temperature ## Datasheet - Compact ModBus master to IO-Link device converter for use with QM30VT2 Vibration and Temperature sensor - Predefined ModBus registers are sent over IO-Link automatically - Rugged over-molded design meets IEC IP65, IEC IP67, and IEC IP68 - Connects directly to a sensor or anywhere in-line for ease of use ## Models **==> picture [499 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Housing Function Female Male Connector<br>S15 C - MVT - K Q<br>C = Converter MVT = Modbus Vibration Temperature K = IO-Link Q = Integral M12/Euro-style quick disconnect<br>**----- End of picture text -----**<br> ## IO-Link[®] IO-Link[®] is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.iolink.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. ## Process Data In (Device to Master) The S15C converter provides for the reading of three user-selectable sets of 15 Modbus Registers. For more information, see Banner P/N 210732 Sure Cross[®] QM30VT2 Vibration and Temperature Sensor, Banner P/N 217177 S15C Modbus Converter (Vibration and Temperature) - IO-Link Data Reference Guide, and Banner P/N 217160 S15C-MVT-KQ IODD Files. ## RegSet 0 Register Set 0 reads the following Modbus Registers with Imperial System values as applicable: |RegSet 0|RegSet 0|RegSet 0| |---|---|---| |Reg Adr 01|45201|Z-Axis RMS Velocity (in/sec)| |Reg Adr 02|45203|Temperature (°F)| |Reg Adr 03|45205|X-Axis RMS Velocity (in/sec)| |Reg Adr 04|45207|Z-Axis RMS Peak Acceleration (G)| |Reg Adr 05|45208|X-Axis RMS Peak Acceleration (G)| |Reg Adr 06|45209|Z-Axis Peak Velocity Component Frequency (Hz)| |Reg Adr 07|45210|X-Axis Peak Velocity Component Frequency (Hz)| |Reg Adr 08|45213|Z-Axis Kurtosis| |Reg Adr 09|45214|X-Axis Kurtosis| |Reg Adr 10|45215|Z-Axis Crest Factor| |Reg Adr 11|45216|X-Axis Crest Factor| |Reg Adr 12|45217|Z-Axis Peak Velocity (in/sec)| |Reg Adr 13|45219|X-Axis Peak Velocity (in/sec)| |Reg Adr 14|45221|Z-Axis High-Frequency RMS Acceleration (G)| |Reg Adr 15|45222|X-Axis High-Frequency RMS Acceleration (G)| Original Document 217586 Rev. C 17 September 2020 217586 S15C Modbus Master to IO-Link Device Converter for Vibration and Temperature ## RegSet 1 Register Set 1 reads the following Modbus Registers with Metric System values as applicable: |RegSet 1|RegSet 1|RegSet 1| |---|---|---| |Reg Adr 01|45202|Z-Axis RMS Velocity (mm/sec)| |Reg Adr 02|45204|Temperature (°C)| |Reg Adr 03|45206|X-Axis RMS Velocity (mm/sec)| |Reg Adr 04|45207|Z-Axis RMS Peak Acceleration (G)| |Reg Adr 05|45208|X-Axis RMS Peak Acceleration (G)| |Reg Adr 06|45209|Z-Axis Peak Velocity Component Frequency (Hz)| |Reg Adr 07|45210|X-Axis Peak Velocity Component Frequency (Hz)| |Reg Adr 08|45213|Z-Axis Kurtosis| |Reg Adr 09|45214|X-Axis Kurtosis| |Reg Adr 10|45215|Z-Axis Crest Factor| |Reg Adr 11|45216|X-Axis Crest Factor| |Reg Adr 12|45218|Z-Axis Peak Velocity (mm/sec)| |Reg Adr 13|45220|X-Axis Peak Velocity (mm/sec)| |Reg Adr 14|45221|Z-Axis High-Frequency RMS Acceleration (G)| |Reg Adr 15|45222|X-Axis High-Frequency RMS Acceleration (G)| ## RegSet 2 Register Set 2 reads the following Modbus Registers specific to sensor information: |RegSet 2|RegSet 2|RegSet 2| |---|---|---| |Reg Adr 01|44101|Serial Number Upper| |Reg Adr 02|44102|Serial Number Lower| |Reg Adr 03|44103|Model Number Upper| |Reg Adr 04|44104|Model Number Lower| |Reg Adr 05|44105|Production Date Upper| |Reg Adr 06|44106|Production Date Lower| |Reg Adr 07|44301|RF Firmware Part Number Upper| |Reg Adr 08|44302|RF Firmware Part Number Lower| |Reg Adr 09|44303|RF Firmware Version Upper| |Reg Adr 10|44304|RF Firmware Version Lower| |Reg Adr 11|44305|RF Firmware Version Engineering| |Reg Adr 12|44306|RF EEPROM Part Number Upper| |Reg Adr 13|44307|RF EEPROM Part Number Lower| |Reg Adr 14|44308|RF EEPROM Version Upper| |Reg Adr 15|44309|RF EEPROM Version Lower| ## Wiring Diagrams |Male|Female|Pin|Wire Color| |---|---|---|---| |**1**<br>**4**<br>**3**<br>**2**|**2**<br>**3**<br>**4**<br>**1**|1|Brown| |||2|White| |||3|Blue| |||4|Black| P/N 217586 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 2 S15C Modbus Master to IO-Link Device Converter for Vibration and Temperature |Female (Sensor)|Signal Description| |---|---| |Pin 1|18 V DC to 30 V DC| |Pin 2|RS485/D1/B/+| |Pin 3|Ground| |Pin 4|RS485/D0/A/-| |Male (IO-Link Master)|Signal Description| |---|---| |Pin 1|18 V DC to 30 V DC| |Pin 2|Banner-specifc| |Pin 3|Ground| |Pin 4|IO-Link| ## Status Indicators ## Power LED Indicator (Green) - Solid Green = Power On - Off = Power Off IO-Link Communication LED Indicator (Amber) - Flashing Amber (900 ms On, 100 ms Off) = IO-Link communications are active - Off = IO-Link communications are not present Modbus Communication LED Indicator (Amber) - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 seconds - Off = Modbus communications are not present ## Specifications Supply Voltage 18 V DC to 30 V DC at 50 mA maximum Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicators Green power Amber IO-Link communications Amber ModBus communications Connections Integral male/female 4-pin M12/Euro-style quick disconnect Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Certifcations Environmental Rating IEC IP65, IEC IP67, IEC IP68 NEMA/UL Type 1 Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |Supply Wiring (AWG)|Required Overcurrent Protection (Amps)| |---|---| |20|5.0| |22|3.0| |24|2.0| |26|1.0| |28|0.8| |30|0.5| P/N 217586 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 3 S15C Modbus Master to IO-Link Device Converter for Vibration and Temperature ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [415 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 57.8<br>[2.27]<br>27.9<br>[1.1]<br>15.0<br>[0.59]<br>M12 X 1 - 6H<br>M12 X 1 - 6g<br>**----- End of picture text -----**<br> ## Accessories ## Cordsets |4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended||| |---|---|---|---|---|---| |Model|Length|Style|Dimensio|ns|Pinout| |MQDEC-401SS|0.31 m (1 ft)|Male Straight/<br>Female Straight|40 Typ.<br>[1.58"]<br>ø 14.5 [0.57"]<br>M12 x 1<br>44 Typ.<br>[1.73"]<br>ø 14.5 [0.57"]<br>M12 x 1||Female<br>**2**<br>**3**<br>**4**<br>**1**<br>Male<br>**1**<br>**4**<br>**3**<br>**2**<br>1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black| |MQDEC-403SS|0.91 m (2.99 ft)||||| |MQDEC-406SS|1.83 m (6 ft)||||| |MQDEC-412SS|3.66 m (12 ft)||||| |MQDEC-420SS|6.10 m (20 ft)||||| |MQDEC-430SS|9.14 m (30.2 ft)||||| |MQDEC-450SS|15.2 m (49.9 ft)||||| ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. P/N 217586 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 4 S15C Modbus Master to IO-Link Device Converter for Vibration and Temperature ## FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the manufacturer. © Banner Engineering Corp. All rights reserved
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.