S15C-MGN-KQ
CONVERTERS
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 100.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
## S15C Modbus Master to IO-Link Device Converter ## Datasheet - Compact Modbus master to IO-Link device converter that is userconfigurable to read up to 60 registers and write up to 15 - - Predefined ModBus registers are sent over IO-Link automatically - Rugged over-molded design meets IEC IP65, IEC IP67, and IEC IP68 - Connects directly to a sensor or anywhere in-line for ease of use ## Models **==> picture [499 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Housing Function Female Male Connector<br>S15 C - MGN - K Q<br>C = Converter MGN = Modbus Generic K = IO-Link Q = Integral M12/Euro-style quick disconnect<br>**----- End of picture text -----**<br> ## Configuration For more information, see Banner P/N 217176 S15C Modbus Converter (Generic) - IO-Link Data Reference Guide and Banner P/N 217165 S15C-MGN-KQ IODD Files. ## IO-Link[®] IO-Link[®] is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.iolink.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. ## Register Read The status of Modbus Register Reads is available via Process Data In. The S15C converter provides for the reading of four userselectable sets of Modbus Registers: - Read Register Set 0 - Read Register Set 1 - Read Register Set 2 - Read Register Set 3 Using IO-Link Parameter values, each Read Register Set allows 15 ModBus register addresses to be entered and read. Using the Register Set To Read value in the Process Data Out, four sets of 15 ModBus registers can be read over Process Data In for a potential total of 60 unique ModBus register reads. ## Register Write The status of Modbus Register Writes and Verification is available via Process Data In. The S15C converter provides for writing data to 15 Modbus registers. Using IO-Link Parameter values, the following write update types are available: - Write Each Cycle - Write Once - Write Each Cycle if Mismatched - Write Once if Mismatched Using IO-Link Parameter values, the choice of verifying the results of a write is available, along with the following write command types: - Use Write Single Register Command - Use Write Multiple Register Command Original Document 217584 Rev. C 17 September 2020 217584 S15C Modbus Master to IO-Link Device Converter ## Wiring Diagrams |Male|Female|Pin|Wire Color| |---|---|---|---| |**1**<br>**4**<br>**3**<br>**2**|**2**<br>**3**<br>**4**<br>**1**|1|Brown| |||2|White| |||3|Blue| |||4|Black| |Female (Sensor)|Signal Description| |---|---| |Pin 1|18 V DC to 30 V DC| |Pin 2|RS485/D1/B/+| |Pin 3|Ground| |Pin 4|RS485/D0/A/-| ||| |Male (IO-Link Master)|Signal Description| |Pin 1|18 V DC to 30 V DC| |Pin 2|Banner-specifc| |Pin 3|Ground| |Pin 4|IO-Link| ## Status Indicators Power LED Indicator (Green) - Solid Green = Power On - Off = Power Off IO-Link Communication LED Indicator (Amber) - Flashing Amber (900 ms On, 100 ms Off) = IO-Link communications are active - Off = IO-Link communications are not present Modbus Communication LED Indicator (Amber) - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 seconds - Off = Modbus communications are not present P/N 217584 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 2 S15C Modbus Master to IO-Link Device Converter ## Specifications Supply Voltage 18 V DC to 30 V DC at 50 mA maximum Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicators Green power Amber IO-Link communications Amber ModBus communications Connections Integral male/female 4-pin M12/Euro-style quick disconnect Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Certifcations |Environmental Rating<br>IEC IP65, IEC IP67, IEC IP68<br>NEMA/UL Type 1<br>Operating Conditions<br>Temperature:–40 °C to +70 °C (–40 °F to +158 °F)<br>90% at +70 °C maximum relative humidity (non-condensing)<br>Storage Temperature:–40 °C to +80 °C (–40 °F to +176 °F)<br>Required Overcurrent Protection<br>WARNING:Electrical connections must be<br>made by qualifed personnel in accordance with<br>local and national electrical codes and<br>regulations.<br>Overcurrent protection is required to be provided by end product<br>application per the supplied table.<br>Overcurrent protection may be provided with external fusing or via Current<br>Limiting, Class 2 Power Supply.<br>Supply wiring leads < 24 AWG shall not be spliced.<br>For additional product support, go towww.bannerengineering.com.<br>Supply Wiring (AWG)<br>Required Overcurrent Protection (Amps)<br>20<br>5.0<br>22<br>3.0<br>24<br>2.0<br>26<br>1.0<br>28<br>0.8<br>30<br>0.5|Environmental Rating<br>IEC IP65, IEC IP67, IEC IP68<br>NEMA/UL Type 1<br>Operating Conditions<br>Temperature:–40 °C to +70 °C (–40 °F to +158 °F)<br>90% at +70 °C maximum relative humidity (non-condensing)<br>Storage Temperature:–40 °C to +80 °C (–40 °F to +176 °F)<br>Required Overcurrent Protection<br>WARNING:Electrical connections must be<br>made by qualifed personnel in accordance with<br>local and national electrical codes and<br>regulations.<br>Overcurrent protection is required to be provided by end product<br>application per the supplied table.<br>Overcurrent protection may be provided with external fusing or via Current<br>Limiting, Class 2 Power Supply.<br>Supply wiring leads < 24 AWG shall not be spliced.<br>For additional product support, go towww.bannerengineering.com.<br>Supply Wiring (AWG)<br>Required Overcurrent Protection (Amps)<br>20<br>5.0<br>22<br>3.0<br>24<br>2.0<br>26<br>1.0<br>28<br>0.8<br>30<br>0.5|Environmental Rating<br>IEC IP65, IEC IP67, IEC IP68<br>NEMA/UL Type 1<br>Operating Conditions<br>Temperature:–40 °C to +70 °C (–40 °F to +158 °F)<br>90% at +70 °C maximum relative humidity (non-condensing)<br>Storage Temperature:–40 °C to +80 °C (–40 °F to +176 °F)<br>Required Overcurrent Protection<br>WARNING:Electrical connections must be<br>made by qualifed personnel in accordance with<br>local and national electrical codes and<br>regulations.<br>Overcurrent protection is required to be provided by end product<br>application per the supplied table.<br>Overcurrent protection may be provided with external fusing or via Current<br>Limiting, Class 2 Power Supply.<br>Supply wiring leads < 24 AWG shall not be spliced.<br>For additional product support, go towww.bannerengineering.com.<br>Supply Wiring (AWG)<br>Required Overcurrent Protection (Amps)<br>20<br>5.0<br>22<br>3.0<br>24<br>2.0<br>26<br>1.0<br>28<br>0.8<br>30<br>0.5| |---|---|---| ||Supply Wiring (AWG)|Required Overcurrent Protection (Amps)| ||20|5.0| ||22|3.0| ||24|2.0| ||26|1.0| ||28|0.8| ||30|0.5| ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [415 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 57.8<br>[2.27]<br>27.9<br>[1.1]<br>15.0<br>[0.59]<br>M12 X 1 - 6H<br>M12 X 1 - 6g<br>**----- End of picture text -----**<br> P/N 217584 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 3 S15C Modbus Master to IO-Link Device Converter ## Accessories ## Cordsets |4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended|4-Pin Threaded M12/Euro-Style Cordsets—Double Ended||| |---|---|---|---|---|---| |Model|Length|Style|Dimensio|ns|Pinout| |MQDEC-401SS|0.31 m (1 ft)|Male Straight/<br>Female Straight|40 Typ.<br>[1.58"]<br>ø 14.5 [0.57"]<br>M12 x 1<br>44 Typ.<br>[1.73"]<br>ø 14.5 [0.57"]<br>M12 x 1||Female<br>**2**<br>**3**<br>**4**<br>**1**<br>Male<br>**1**<br>**4**<br>**3**<br>**2**<br>1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black| |MQDEC-403SS|0.91 m (2.99 ft)||||| |MQDEC-406SS|1.83 m (6 ft)||||| |MQDEC-412SS|3.66 m (12 ft)||||| |MQDEC-420SS|6.10 m (20 ft)||||| |MQDEC-430SS|9.14 m (30.2 ft)||||| |MQDEC-450SS|15.2 m (49.9 ft)||||| ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the manufacturer. © Banner Engineering Corp. All rights reserved
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →