S15C-CT20A-MQ
Signal Converter, 20 A, Current Transformer, Modbus, 1 Channels, 30 VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
- Accuracy %: -
- Product Range: S15C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Current Transformer
- Signal Conditioner Output: Modbus
- Signal Conditioner Mounting: Cable Mount
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 134.02 € |
| Current stock | 10+ |
| Lead time | 30 days |
S15C Current Transformer to Modbus Con verter ## Features - Connects to the included current transformer and outputs the value to Modbus registers - Monitors AC current for various devices using current transformers - • Converts a high-voltage input to a proportional low-voltage, low-current signal for measuring and monitoring - Meets IP65, IP67, and IP68 ratings with a rugged overmolded housing ## S15C-CT Models Housing Function Female End Male End Connector S15 C - CT20A - M Q C = Converter CT20A = 20A Current Transformer M = Modbus Q = Integral M12 quick disconnect J979 Ff GF CT150A = 150A Current Transformer CT600A = 600A Current Transformer Split-core current transformers are used to monitor AC current for various devices. The current transformer input takes a high voltage current input and produces a proportional low-voltage, low-current signal for measuring and monitoring. Split-core current transformers are ideal for installing onto existing electrical wiring because they can snap around the individual conductors without having to disconnect any cables. NOTE: Users can use any size current transformer rated up to a 655 A max rating, as long as the current transformer has a 333 mV AC output. ## Installing the Current Transformers Observe the polarity when installing current transformers. Banner's current transformers indicate k as the source side and l as the load side, where source refers to the incoming power feed side to the device and the load side is the device side. Banner's CTs have an etched arrow to indicate the directionality for installation (k > l). As shown in "Installing a current transformer relative to the power supply/motor" on page 2, the source is the AC power supply and the load is the Motor. The CT direction arrow must point toward the load. Banner's current transformers can be installed on any conductor in a 2 or 3phase AC line. Current transformers should only be in stalled on a single conductor. For the correct installation, see "Installing a single conductor on the current transformer" on page 2. Original Instructions June 29, 2023 p/n: 235152 Rev. B © Banner Engineering Corp. 235152 S15C Current Transformer to Modbus Converter **==> picture [232 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Installing a current transformer relative to the power supply/motor<br>**----- End of picture text -----**<br> **==> picture [319 x 290] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>MOTOR<br>POWER<br>Installing a single conductor on the current transformer<br>YES NO<br>**----- End of picture text -----**<br> **==> picture [31 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> RS-485<br>**----- End of picture text -----**<br> ## Wire the Current Transformer For more information on wiring and installing the current transformer, refer to the Split Core Current Transformer datasheet (p/n 212463). **==> picture [500 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> Current transformer wiring<br>wh<br>k +<br>l bk –<br>Wire Color Description<br>White Input from CT (k)<br>Black CT ground (l)<br>**----- End of picture text -----**<br> **==> picture [500 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Converter Wiring<br>**----- End of picture text -----**<br> **==> picture [243 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> Female: Male:<br>1 1 (bn)<br>10-30 V DC 10-30 V DC<br>2 2 (wh)<br>Current RS485/D1/B/+<br>4 4 (bk)<br>RS485/D0/A/-<br>3 3 (bu)<br>Ground<br>**----- End of picture text -----**<br> page 2 June 29, 2023 © Banner Engineering Corp. S15C Current Transformer to Modbus Converter **==> picture [500 x 262] intentionally omitted <==** **----- Start of picture text -----**<br> Male (Gateway) Female (Sensor) Pin Wire Color<br>1 1 Brown<br>2 2 White<br>2<br>1 3 Blue<br>4<br>3<br>3 4 4 Black<br>Female (Sensor) Signal Description<br>Pin 1 10 V DC to 30 V DC<br>Pin 2 CT Input<br>Pin 3 Not Used<br>Pin 4 CT Ground<br>Male (Gateway) Signal Description<br>Pin 1 10 V DC to 30 V DC<br>Pin 2 RS485/D1/B/+<br>Pin 3 Ground<br>Pin 4 RS485/D0/A/<br>**----- End of picture text -----**<br> ## Configuration Instructions ## Sensor Configuration Software The Sensor Configuration Software offers an easy way to manage converter Modbus settings, retrieve data, and visually show converter da ta. The Sensor Configuration Software runs on any Windows machine and uses an adapter cable (BWA-UCT-900, p/n 19970) to connect the converter to the computer. Download the most recent version of the Sensor Configuration Software from the Banner Engineering website: https:// info.bannerengineering.com/cs/groups/public/documents/software/b_3128586.exe. ## S15CCT Modbus Configuration **==> picture [500 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> Modbus Register Address Type Name I/O Range Description Notes Default [(1)]<br>IO Data Out<br>0-2000,<br> 40001 uint16, Read Only IO Data 065535 Analog Data output AC RMS Current (A) = Register Value/100 0-15000, or 0-60000<br>Alarm State for IO based on Min<br> 40002 bool, Read IO Alarm and Max thresholds defined in Ana 0 = Within threshold range <br>Only State log In Min Value () and Analog In 1 = Out of threshold range<br>Max Value ()<br> 40003 int16, Read Only IO Error Status STATUS_ERROR_TYPE_NO_ERROR = 0STATUS_ERROR_TYPE_BELOW_MIN = 1 Status of program 02 value <br>STATUS_ERROR_TYPE_ABOVE_MAX = 2<br>IO Data Rate<br> 41201 uint16, Read and Write Sample IO 065535 Sample interval time for IO Increments of 62.5 ms 16 (1 second)<br>Minimum Value<br> 41204 uint16, Read Minimum Ana Minimum analog value for data Minimum value: 0 0<br>and Write log Value read<br>Maximum Value<br> 41205 uint16, Read and Write Maximum Analog Value Max analog value for data read Maximum value 20, 150, or 600<br>CT Type Input<br>Continued on page 4<br>**----- End of picture text -----**<br> (1) Based on the model selected June 29, 2023 page 3 © Banner Engineering Corp. S15C Current Transformer to Modbus Converter **==> picture [500 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 3<br>Modbus Register Address Type Name I/O Range Description Notes Default<br>41011 int16, Read and Write AC Line Frequency 1 = 60 Hz2 = 50 Hz AC Line Frequency 1 = 60 Hz2 = 50 Hz 1<br> 41015 uint16, Read and Write CT Amp value 0655 Amp value of the transformer usedUserdefined: 0655 20, 150, or 600<br>COMs Settings<br>0 = 9.6k<br> 46101 Baud Rate 1 = 19.2k 1<br>2 = 38.4k<br>0 = None<br> 46102 Parity 1 = Odd 0<br>2 = Even<br>Modbus<br> 46103 Slave Ad 1 to 247 1<br>dress<br>**----- End of picture text -----**<br> ## Status Indicators ## Power LED Indicator (Green) - Solid Green = Power On - Off = Power Off ## Modbus Communication LED Indicator (Amber) - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 sec onds - Off = Modbus communications are not present ## S15C-CT Specifications ## Supply Voltage 10 V DC to 30 V DC at 50 mA maximum Power Pass-Through Current 4 A maximum Supply Protection Circuitry Protected against reverse polarity and transient voltages ## Leakage Current Immunity 400 µA ## Resolution 12-bits ## Current Transformer ## Electrical: Rated Input: 0-20 A (CT20A), 0-150 A (CT150A), or 0-600 A (CT600A), depending on the model Rated Output: 0.333 V AC Ratio: ≤ ± 1.0% Phase Angle: ≤ ± 60 min Dielectric Strength: 2.5 kV/1 mA/1 min Insulation Resistance: DC 500 V/100 MΩ min ## Mechanical: Case: PA / UL94V0 Bobbin: PBT Core: Silicon Steel ## Indicators Green power Amber Modbus communications ## Connections Integral male/female 4-pin M12 quick disconnect ## Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068227 requirements (Shock: 15G 11 ms dura tion, half sine wave) Environmental Rating IP65, IP67, IP68 NEMA/UL Type 1 Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) –25 °C to +75 °C (–13 °F to +167 °F) ≤ 85% maximum relative humidity (noncondensing) For more information, refer to the Split Core Current Trans former datasheet (p/n 212463) Required Overcurrent Protection **==> picture [32 x 42] intentionally omitted <==** WARNING: Electrical connections must be made by qualified personnel in ac cordance with local and national electri cal codes and regulations. Overcurrent protection is required to be provided by end prod uct application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. June 29, 2023 page 4 © Banner Engineering Corp. S15C Current Transformer to Modbus Converter **==> picture [403 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply Certifications<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A) Banner Engineering BV<br>(AWG) (AWG)<br>Park Lane, Culliganlaan 2F bus 3<br>20 5.0 26 1.0 1831 Diegem, BELGIUM<br>22 3.0 28 0.8<br>l ] K TurckBlenheim BannerCourt LTD Blenheim House<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> ## FCC Part 15 Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc tion manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ## Industry Canada This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Current Transformer Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. Model Diameter A B C CT20A 10 mm (0.39 in) 41 mm (1.61 in) 24 mm (0.94 in) 26.5 mm (1.04 in) CT150A 16 mm (0.63 in) 45.5 mm (1.79 in) 29 (1.14 in) 31.5 mm (1.24 in) CT600A 35.7 mm (1.41 in) 92.9 mm (3.66 in) 65.25 mm (2.57 in) 42 mm (1.65 in) June 29, 2023 page 5 © Banner Engineering Corp. S15C Current Transformer to Modbus Converter ## Accessories ## Cordsets **==> picture [500 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> 4Pin Threaded M12 Cordsets—Double Ended<br>Model Length Style Dimensions Pinout<br>MQDEC401SS 0.31 m (1 ft) Female<br>MQDEC-403SS 0.91 m (2.99 ft)<br>2<br>40 Typ.<br>MQDEC-406SS 1.83 m (6 ft) [1.58"] 1<br>MQDEC412SS 3.66 m (12 ft) 4 3<br>MQDEC420SS 6.10 m (20 ft) M12 x 1<br>MQDEC430SS 9.14 m (30.2 ft) Male Straight/Female ø 14.5 [0.57"] Male<br>Straight 44 Typ.<br>[1.73"] 1<br>2<br>4<br>MQDEC450SS 15.2 m (49.9 ft) M12 x 1 3<br>ø 14.5 [0.57"] 1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BAN NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan guage. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 6 June 29, 2023 © Banner Engineering Corp.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →