S15C-CT-MQ
Signal Converter, Current, Modbus, 1 Channels, 30 VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
- Accuracy %: -
- Product Range: S15C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Current
- Signal Conditioner Output: Modbus
- Signal Conditioner Mounting: Cable Mount
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 175.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
S15C Current Transformer to Modbus® Converter ## Features **==> picture [121 x 112] intentionally omitted <==** - Connects to the included current transformer and outputs the value to Modbus registers - Monitors AC current for various devices using current transformers - • Converts a high-voltage input to a proportional low-voltage, low-current signal for measuring and monitoring - Meets IP65, IP67, and IP68 ratings with a rugged overmolded housing ## Models **==> picture [474 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> Housing Function Female End Male End Connector<br>S15 C - CT - M Q<br>C = Converter CT = Current Transformer M = Modbus Q = Integral M12 quick disconnect<br>**----- End of picture text -----**<br> The converter comes with the following current transformer models included: **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> Model Kits Description Connection<br>BWA-CURRENT-TRANSFORMER-20A Includes CT20A; 20 A Input; 0.333 V Output<br>1 meter two-wire twisted pair cable<br>BWA-CURRENT-TRANSFORMER-150A Includes CT150A; 150 A Input; 0.333 V Output<br>**----- End of picture text -----**<br> Split-core current transformers are used to monitor AC current for various devices. The current transformer input takes a high-voltage current input and produces a proportional low-voltage, low-current signal for measuring and monitoring. Split-core current transformers are ideal for installing onto existing electrical wiring because they can snap around the individual conductors without disconnecting any cables. NOTE: Although the system comes with a 20 A and a 150 A current transformer, users can use any size current transformer rated up to a 655 A max rating, as long as the current transformer has a 333 mV AC output. ## Installing the Current Transformers Observe the polarity when installing current transformers. Banner's current transformers indicate k (S1) as the source side and l (S2) as the load side, where source refers to the incoming power feed side to the device and the load side is the device side. Banner's CTs have an etched arrow to indicate the directionality for installation (k (S1) -> l (S2)). As shown in "Figure: Installing a current transformer relative to the power supply/motor" on page 2, the source is the AC power supply and the load is the Motor. The CT direction arrow must point toward the load. Banner's current transformers can be installed on any conductor in a 2- or 3-phase AC line. Current transformers should only be installed on a single conductor. For the correct installation, see "Figure: Installing a single conductor on the current transformer" on page 2. Original Instructions June 14, 2024 © Banner Engineering Corp. p/n: 223252 Rev. J S15C Current Transformer to Modbus® Converter **==> picture [332 x 302] intentionally omitted <==** **----- Start of picture text -----**<br> Installing a current transformer relative to the power supply/motor<br>AC<br>MOTOR<br>POWER<br>RS-485<br>Installing a single conductor on the current transformer<br>YES NO<br>**----- End of picture text -----**<br> ## Wire the Current Transformer For more information on wiring and installing the current transformer, refer to the Split Core Current Transformer datasheet (p/n 212463). **==> picture [94 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> Current transformer wiring<br>CT<br>wh<br>k (S1) +<br>l (S2) bk –<br>**----- End of picture text -----**<br> **==> picture [500 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> Wire Color Description<br>White Input from CT - k (S1)<br>Black CT ground - l (S2)<br>Converter Wiring<br>Female: Male:<br>1 1 (bn)<br>10-30 V DC 10-30 V DC<br>2 2 (wh)<br>Current RS485/D1/B/+<br>Transformer 4 4 (bk) RS485/D0/A/-<br>3 3 (bu)<br>Ground<br>**----- End of picture text -----**<br> page 2 June 14, 2024 © Banner Engineering Corp. All rights reserved. S15C Current Transformer to Modbus® Converter **==> picture [500 x 254] intentionally omitted <==** **----- Start of picture text -----**<br> Male (Gateway) Female (Sensor) Pin Wire Color<br>1 1 Brown<br>2 2 White<br>2<br>1 3 Blue<br>4 3<br>4 4 Black<br>3<br>Female (Sensor) Signal Description<br>Pin 1 10 V DC to 30 V DC<br>Pin 2 CT Input<br>Pin 3 Not Used<br>Pin 4 CT Ground<br>Male (Gateway) Signal Description<br>Pin 1 10 V DC to 30 V DC<br>Pin 2 RS485/D1/B/+<br>Pin 3 Ground<br>Pin 4 RS485/D0/A/-<br>**----- End of picture text -----**<br> ## Configuration Instructions ## Sensor Configuration Software The Sensor Configuration Software offers an easy way to manage converter Modbus settings, retrieve data, and visually show converter data. The Sensor Configuration Software runs on any Windows machine and uses an adapter cable (BWA-UCT-900, p/n 19970) to connect the converter to the computer. Download the most recent version of the Sensor Configuration Software from the Banner Engineering website: https:// info.bannerengineering.com/cs/groups/public/documents/software/b_3128586.exe. ## S15C-CT Modbus Configuration **==> picture [500 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> Modbus Register Address Type Name I/O Range Description Notes Default [(1)]<br>IO Data Out<br>0-2000,<br>40001 uint16, Read Only IO Data 0-65535 Analog Data output AC RMS Current (A) = Register Value/100 0-15000, or 0-60000<br>Alarm State for IO based on Min<br>40002 bool, Read IO Alarm State - and Max thresholds defined in 0 = Within threshold range -<br>Only Analog In Min Value () and Analog 1 = Out of threshold range<br>In Max Value ()<br>40003 int16, Read IO Error Status STATUS_ERROR_TYPE_NO_ERROR = 0STATUS_ERROR_TYPE_BELOW_MIN = 1 Status of program 0-2 value -<br>Only<br>STATUS_ERROR_TYPE_ABOVE_MAX = 2<br>40801 uint16, Read Measurement FIFO maximum<br>Only List Max<br>40802 uint16, Read Measurement FIFO minimum<br>Only List Min<br>40803 uint16, Read Measurement FIFO mean<br>Only List Mean<br>40811-40820 uint16, Read Measurement 0-65535 FIFO (first in, first out) list of the<br>Only List past 10 measurements<br>IO Data Rate<br>41201 uint16, Read and Write Sample IO 0-65535 Sample interval time for IO Increments of 62.5 ms 16 (1 second)<br>Minimum Value<br>Continued on page 4<br>**----- End of picture text -----**<br> (1) Based on the model selected June 14, 2024 page 3 © Banner Engineering Corp. All rights reserved. S15C Current Transformer to Modbus® Converter **==> picture [488 x 218] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Continued from page 3| |Modbus Register Address|Type|Name|I/O Range|Description|Notes|Default| |41204|uint16, Read|Minimum|-|Minimum analog value for data|Minimum value: 0|0| |and Write|Analog Value|read| |Maximum Value| |41205|uint16, Read and Write|Maximum Analog Value|-|Max analog value for data read|Maximum value|20, 150, or 600| |CT Type Input| |41011|int16, Read and Write|AC Line Frequency|1 = 60 Hz2 = 50 Hz|AC Line Frequency|1 = 60 Hz2 = 50 Hz|1| |41015|uint16, Read and Write|CT Amp value|0-655|Amp value of the transformer usedUser-defined: 0-655|-|20, 150, or 600| |COMs Settings| |0 = 9.6k| |46101|Baud Rate|-|1 = 19.2k|-|-|1| |2 = 38.4k| |0 = None| |46102|Parity|-|1 = Odd|-|-|0| |2 = Even| |Modbus| |46103|Slave|-|1 to 247|-|-|1| |Address| **----- End of picture text -----**<br> ## Status Indicators Power LED Indicator (Green) - Solid Green = Power On - Off = Power Off Modbus Communication LED Indicator (Amber) - Flashing Amber (4 Hz) = Modbus communications are active - Solid Amber for 2 seconds to Off = Modbus communications are lost after connection - Solid Amber for 2 seconds to Flashing Amber (4 Hz) = Modbus communications momentarily lost, but communication reestablished - Solid Amber = Modbus communications are intermittent, or communications error occurs more frequently than once every 2 seconds - Off = Modbus communications are not present ## S15C-CT Specifications Supply Voltage 10 V DC to 30 V DC at 50 mA maximum Power Pass-Through Current 4 A maximum Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Resolution 12-bits Current Transformer ## Electrical: Rated Input: 0-20 A (CT20A), 0-150 A (CT150A), or 0-600 A (CT600A), depending on the model Rated Output: 0.333 V AC Ratio: ≤ ± 1.0% Phase Angle: ≤ ± 60 min Dielectric Strength: 2.5 kV/1 mA/1 min Insulation Resistance: DC 500 V/100 MΩ min ## Mechanical: Case: PA / UL94-V0 Bobbin: PBT Core: Silicon Steel Indicators Green power Amber Modbus communications Connections Integral male/female 4-pin M12 quick-disconnect connector Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Environmental Rating IP65, IP67, IP68 UL Type 1 Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) Product Identification - –25 °C to +75 °C (–13 °F to +167 °F) - ≤ 85% maximum relative humidity (non-condensing) For more information, refer to the Split Core Current Transformer datasheet (p/n 212463) June 14, 2024 page 4 © Banner Engineering Corp. All rights reserved. S15C Current Transformer to Modbus® Converter ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [208 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> Certifications **==> picture [101 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> Banner Engineering BV<br>Park Lane, Culliganlaan 2F bus 3<br>1831 Diegem, BELGIUM<br>Turck Banner LTD Blenheim House<br>Blenheim Court<br>Wickford, Essex SS11 8YT<br>GREAT BRITAIN<br>**----- End of picture text -----**<br> ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - • Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. **==> picture [462 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> 58<br>[2.28]<br>Ø Approx.<br>A<br>fal 1000 _<br>[39.5]<br>M12 X 1 - 6h<br>B C<br>Model Diameter A B C<br>CT20A 10 mm (0.39 in) 41 mm (1.61 in) 24 mm (0.94 in) 26.5 mm (1.04 in)<br>CT150A 16 mm (0.63 in) 45.5 mm (1.79 in) 29 (1.14 in) 31.5 mm (1.24 in)<br>**----- End of picture text -----**<br> June 14, 2024 page 5 © Banner Engineering Corp. All rights reserved. S15C Current Transformer to Modbus® Converter ## Accessories ## Cordsets **==> picture [500 x 200] intentionally omitted <==** **----- Start of picture text -----**<br> 4-Pin Threaded M12 Cordsets—Double Ended<br>Model Length Style Dimensions Pinout<br>MQDEC-401SS 0.31 m (1 ft) Female<br>MQDEC-403SS 0.91 m (2.99 ft)<br>2<br>MQDEC-406SS 1.83 m (6 ft) 40 Typ.[1.58"] 1<br>MQDEC-412SS 3.66 m (12 ft) 4 3<br>MQDEC-415SS 4.58 m (15 ft) M12 x 1<br>MQDEC-420SS 6.10 m (20 ft) Male Straight/Female ø 14.5 [0.57"] Male<br>MQDEC-430SS 9.14 m (30.2 ft) Straight 44 Typ. 1<br>[1.73"]<br>2<br>4<br>M12 x 1 3<br>MQDEC-450SS 15.2 m (49.9 ft) ø 14.5 [0.57"]<br>1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. Document title: S15C Current Transformer to Modbus® Converter Part number: 223252 Revision: J Original Instructions © Banner Engineering Corp. All rights reserved. **==> picture [81 x 43] intentionally omitted <==** **----- Start of picture text -----**<br> 223252<br>**----- End of picture text -----**<br> page 6 June 14, 2024 © Banner Engineering Corp. All rights reserved.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →