- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 907.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Photoelectrics Amplifier, µ-Processor Controlled Type S1430 UAP, 3 Inputs/3 Transistor Outputs** - **µ-Processor controlled** - **Amplifier unit for 3 sets of photoelectrics** - **3 independent outputs** - **NPN/PNP both NO or NC selectable** - **Self-diagnostic functions** - **Alignment failure indication** - **Multivoltage 12 to 30 VAC/DC** - **Modulated and synchronized light** - **Adjustable sensitivity for each channel** - **LED indications: supply, outputs, signal quality** - **11-pin plug-in housing** - **For 115 or 230 VAC use power supplys from SS120-series** **Product Description Ordering Key S14 30 UAP 912** µ-Processor controlled amplidiagnostics for system test. **Type** fier for 3 sets of photoelecProtected against short-cir- **Special function** tric sensors, type MOFTR, cuits, reverse wiring or cross **Output type** ~~=~~ MKFTR, MIFTR or MHFTR. talk from adjacent photoelec- **Power supply** Utilising an 11-pin circular trics. Multi-voltage power plug for easy connection, supply. Sensitivity is indivioutputs freely selectable for dually adjustable for each NPN/PNP or NO/NC. Selfset of photoelectrics. ## **T e Selection yp** **Plug type Ordering no. Supply: 12 - 30 VAC/DC** Circular, 11 pins **S 1430 UAP 912** Circular, 11 pins ## **S ecifications p** |**Rated operational voltage**(UB)|**Supply to photoelectric switch**| |---|---| |pins 2 & 10<br>DC<br>10.8 to 33 VDC<br>AC<br>10.8 to 33VAC,45 to 65 Hz|(cont.)<br>**Receiver**<br>Rx1: Pin 4| |**Rated operational power**<br>AC supply<br>4 VA<br>DC supply<br>3 W<br>**Power ON delay **(tv)<br>< 300 ms<br>**Output function**<br>NPN and PNP switching<br>Make and break function<br>DIP-Switch selectable<br>**Output current**|Rx2: Pin 7<br>Rx3: Pin 8<br>Shield: Pin 5 (common)<br>Supply voltage (open loop)<br>5 VDC<br>Short-circuit current<br>10 mA<br>Input resistance<br>470Ω<br>**Sensitivity**<br>• 2 ranges,<br>(% of Sn)<br>DIP-Switch selectable<br>- low sensitivity (25%)| |Continuous (Ie)<br>100 mA per output|- high sensitivity (100%)| |Short-time(I)<br>100 mA max.|• Sensitivity adjustment| |**Min. load current**(Im)<br>0.5 mA<br>**OFF-state current**(Ir)<br>Max. 100µA<br>**Voltage drop **(Ud)<br>≤3.5 VDC<br>**Protection, outputs**<br>Reverse polarity, short-circuit,<br>transients|with 270°:<br>Turn knob on CH 1, 2, 3<br>Note:<br>• Maximum range indi-<br>cated on photoelectric<br>switch data sheet in high<br>sensitivity range only| |**Supply to photoelectric switch**<br>**Emitter**<br>Tx1: Pin 1<br>Tx2: Pin 9<br>Tx3: Pin 6|• Operation within low<br>sensitivity range, increa-<br>ses ambient light and<br>crosstalk immunity| |Shield: Pin 11 (common)<br>Supply voltage (open loop)<br>7 V square wave|**Operating frequency**(f)<br>Light/dark ratio 1:1<br>16 Hz| |Current<br>≤300 mA short-circuit protected|| |Output resistance<br>10Ω|| **1** Specifications are subject to change without notice (25.06.99) **S 1430 UAP** ## **Specifications (cont.)** **==> picture [245 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> Response time<br>OFF-ON (tON) 20 ms<br>ON-OFF (tOFF) 20 ms<br>Indication<br>Supply ON LED, green<br>Output ON LED, yellow<br>Signal quality LED, red<br>Environment<br>Overvoltage category III (IEC 60664)<br>Degree of protection IP 20 (IEC 60529, 60947-1)<br>Pollution degree 3 (IEC 60664/60664A,<br>60947-1)<br>Temperature<br>Operating -20° to +50°C (-4° to +122°F)<br>Storage -50° to +85°C (-58° to 185°F)<br>Weight 150 g<br>Approvals CSA<br>CE-marking Yes<br>**----- End of picture text -----**<br> ## **Truth Table** ||Make switching|Make switching|Make switching|Break switching|Break switching|Break switching| |---|---|---|---|---|---|---| |Object present|Yes|No|No|Yes|No|No| |Dirt on lenses,<br>misaligned or<br>sensitivity toolow|--<br>|No|Yes1)|--|No|Yes1)| |Output LED yellow|OFF|ON|ON|OFF|ON|ON| |Level LED red|OFF|OFF|ON<br>or<br>flashing|OFF|OFF|ON<br>or<br>flashing| |Output NPN/PNP|OFF|ON|ON|ON|OFF|OFF| - 1) Under normal operating conditions, the red level indication LED has to be OFF. The level indication LED will turn on shortly each time an object enters or exits the sensing zone, even if the photoelectric switch is correctly installed and adjusted. ## **Procedure for Test Functions (Dip-Switch Selection)** ## **Transmitter test** **(switch 5 in the up position)** When switch 5 is placed in the up position all yellow and red LED’s on the front of the unit will flash simultaneously. Once the test is completed (approx. 3 scans) and a wiring fault is detected, such as reverse polarity or shortcircuit, the transmitter that has the fault condition will be indicated by the red LED being continuously ON. If a fault condition is not existing then only the yellow LED will be ON. If a fault exists, correct the fault condition and then repeat the test, this will ensure proper wiring has been done. Always reset **switch 5** for normal operation of system when testing completed. ## **Receiver test** **(switch 6 in the up position)** When switch 6 is placed in the up position all yellow and red LED’s on the front of the unit will flash simultaneously. Once the test is completed (approx. 3 scans) and a wiring fault is detected, such as reverse polarity or shortcircuit, the receiver that has the fault condition will be indicated by the red LED being continuously ON. If a fault condition is not existing then only the yellow LED will be ON. If a fault exists, correct the fault condition and then repeat the test, this will ensure proper wiring has been done. Always reset **switch 6** for normal operation of system when testing completed. ## **Function test** **(switch 5 and 6 in the up position)** When switch 5 and 6 are both placed in the up position (simultaneously) the yellow and red LED’s on the front of the housing will begin to flash simultaneously and then the LED’s ## **LED Indication** } - Yellow LED ON - ! Red LED OFF - Yellow LED ON - ! Red LED ON } Yellow LED OFF ! Red LED ON } will cycle from channel 1 to channel 2 and then to channel 3. Once the complete system scan is done the indication of the system condition will be displayed (see below). System test will continue until switch 5 and 6 are reset. **System Test OK** **Tx’s and Rx’s mismatched, e.g. Rx3 seeing Tx1** **Alignment error or beam obstructed by object** ## **O eration Dia ram p g** Signal strength Power supply Object present Signal quality ! Break switching Make switching **==> picture [146 x 36] intentionally omitted <==** **==> picture [21 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Time<br>**----- End of picture text -----**<br> **2** Specifications are subject to change without notice (25.06.99) **S 1430 UAP** ## **Dimensions** DIP-Switch (located behind cover): **==> picture [290 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>a<br>1: PNP/NPN CH 1 output<br>2: PNP/NPN CH 2 output<br>3: PNP/NPN CH 3 output<br>-@<br>“@<br>U sw 1, 2, 3:<br>PNP make/NPN break<br>ia<br>NPN make/PNP break :<br>84<br>sw 5:<br>Transmitter test<br>: Normal operation :<br>sw 5+6:<br>= System test<br>4 75 5<br>80<br>**----- End of picture text -----**<br> **==> picture [227 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 1: PNP/NPN CH 1 output<br>2: PNP/NPN CH 2 output SW 1 2 3 4 5 6<br>**----- End of picture text -----**<br> - 4: Low sensitivity (25%) / high sensitivity (100%) - 5: Test button, transmitters are transmitting, no short, wired correctly - 6: Test button, receivers are receiving, no short, wired correctly 5+6 together: System test (transmitter and receiver) sw 1, 2, 3: sw 4: ~~u~~ PNP make/NPN break Range 25% ~~:~~ NPN make/PNP break : Range 100%, normal operation sw 5: sw 6: ~~uu~~ Transmitter test Receiver test ~~:~~ Normal operation : Normal operation sw 5+6: = System test Normal operation ## **Wiring Diagrams** **==> picture [162 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Rx 1 Tx 1 ON sockets<br>Rx 2 Tx 2 1: Transmitter 1<br>Rx 13 Rx 1T 3 2: Supply (+ VDC)<br>3: No connection<br>4: Receiver 1<br>5: GND (Receivers)<br>5 6 7 6: Transmitter 3<br>4 8 7: Receiver 2<br>3 9 8: Receiver 3<br>2 1 11 10 9: Transmitter 2<br>10: Supply (- VDC)<br>Power Supply<br>**----- End of picture text -----**<br> 5: GND (Receivers) 7: Receiver 2 8: Receiver 3 9: Transmitter 2 10: Supply (- VDC) 11: GND (Transmitters) ## **Output** **==> picture [210 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> Output Wire colour coding<br>A: + (10-40 VDC) white<br>B: Output 1 (max. 100 mA) black<br>C: Output 2 (max. 100 mA) red<br>D: Output 3 (max. 100 mA) green<br>E: For handheld tester yellow<br>F: - DC blue<br>PNP NPN<br>B C D F<br>A B C D F<br>10-40 VDC +- 10-40 VDC +-<br>**----- End of picture text -----**<br> ## **Accessories** ## **Interface** - 11 pole circular socket S111, S111A, S411, ZPD11 - Socket cover for S111 BB1 - Socket cover for S411 BB4 - Holding down spring HF - Mounting rack SM13 - Front panel mounting bezel FRS2 - Connection cable (2 plugs) 2 x 6/6 modular plugs 2.0 m, 6 wires two plugs - - Power supply for 115/230 VAC SS120-series - DIN-rail interface 6IODC ## **Deliver Contents y** - Output connection cable - Output connection cable - Amplifier - DIN-rail interface 1 m, 6 wires one plug 0.2 m, 6 wires two plugs S 1430 UAP 912 6IODC ## **6IODC** DIN-rail interface (DIN EN 50 035, EN 50 022) output from plug to screw terminals - Screw driver - **Packaging:** Cardboard box **3** Specifications are subject to change without notice (25.06.99)
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.