RWS600B12/CO2
Power Supply Approvals:ITE
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: RWS-B Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 50A
- Output Voltage - Output 1: 12V
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 225.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
- RWS B Series ## **50-600W Single Output General Purpose Power Supplies** ## **Features** - Low Cost - Wide Range AC Input 85 - 265VAC (300VAC for 5s) - - Enclosed Construction - Compact Size - 7 Year Warranty ## **Key Market Segments & Applications** ## |Specifi cations|Specifi cations|Specifi cations| |---|---|---| |Specifi cations||| |**Model**<br>**RWS50B**<br>**RWS100B**<br>**RWS150B**<br>**RWS300B**<br>**RWS600B**||| |AC Input Voltage range (1)<br>DC Input Voltage range<br>Inrush Current (100 / 200VAC)<br>Power Factor (100 / 200VAC)<br>Input Current (100/200VAC) (Typ)<br>Temperature Coeffi cient<br>Regulation<br>Overcurrent Protection<br>Overvoltage Protection<br>Hold Up Time (Typ at 100% load)<br>Leakage Current (max)<br>Remote Sense<br>Operating Temperature<br>Storage Temperature<br>Operating Humidity (non condensing) %RH<br>Storage Humidity (non condensing)<br>Cooling<br>Withstand Voltage<br>Isolation Resistance<br>Vibration (non operating)<br>Shock<br>Safety Agency Approvals (2)<br>Conducted & Radiated EMI<br>Immunity<br>Weight (Typ)<br>Size (WxHxD)<br>MTBF - Telcordia SR-332 issue 3**<br>Warranty|VAC<br>VDC<br>A<br>-<br>A<br>-<br>-<br>-<br>V<br>ms<br>uA<br>-<br>-<br>-<br>Operating Humidity (non condensing) %RH<br>%RH<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>g<br>mm<br>In<br>Hours<br>Yrs|85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds<br>120 - 370VDC (330VDC for RWS600B)*<br>18 / 36<br>15 / 30<br>16 / 32<br>17 / 34<br>20 / 40<br>Meets EN61000-3-2 (0.95 / 0.9)<br>1.1 / 0.7<br>1.3 / 0.7<br>1.9 / 1.0<br>3.8 / 2.1<br>7.2 / 4.0<br><0.02%/°C<br>See sheet 2<br>>105%, Constant Current Style<br>115-140%, Cycle AC line to reset<br>20ms (RWS50B: 15ms at 100VAC input)<br>750uA maximum, typically 175uA at 115VAC, 63Hz<br>No<br>-10 to +70°C, derate linearly to 20% load from 50 to 70°C (100-150W from 40 to 70°C) (3)<br>-30 to +75°C<br>30 - 90%RH<br>10 - 90%RH<br>Convection<br>Internal Fan<br>Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.<br>>100M at 25°C & 70%RH, Output to Ground 500VDC<br>10 - 55Hz: 19.6m/s2(sweep 1 min) X, Y, Z for 1 hour<br>< 196.1 m/s2<br>UL / CSA(cUL) / IEC 60950-1 (2nd Ed), UL:508, CSA C22.2 No.107.1-01,<br>CE Mark (Additionally evaluated to EN 60950-1)<br>EN55011 / EN55022-B, FCC Class B, VCCI-B<br>IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2<br>230<br>400<br>480<br>900<br>1600<br>82 x 34 x 81.5<br>94 x 39 x 108<br>94 x 41 x 128<br>102 x 41 x 170<br>120 x 61 x 190<br>3.23 x 1.34 x 3.2<br>3.7 x 1.54 x 4.25<br>3.7 x 1.61 x 5.04<br>4.02 x 1.61 x 6.7<br>4.72 x 2.4 x 7.48<br>Hours<br>4,170,949<br>1,978,533<br>2,235,743<br>2,027,824<br>2,157,340<br>Seven Years| *Safety certifi ed for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input Notes: (1) See Instruction Manual for derating below 115VAC input (2) UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24, RWS300B-24 and RWS600B-24 only (3) RWS600B operates down to -20°C 1-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm 22 ## - RWS B Series ## Output Ratings |||**Adjust Range**|**Max Current**|**Max Output**|**Load Reg**|**Line Reg**|**Ripple Noise**|**Effi ciency (typ) %**| |---|---|---|---|---|---|---|---|---| |**Model**|**Voltage**|**(V)**|**(A)**|**Power**|**(mV)**|**(mV)**|**(mV)**|**100/200VAC**| |RWS50B-5|5V|4.5-5.75V|10|50|40|20|120|77 / 79| |RWS100B-5|5V|4.5-5.75V|14|70|40|20|120|77 / 79| |RWS150B-5|5V|4.5-5.75V|21|105|40|20|120|77 / 79| |RWS300B-5|5V|4.5-5.75V|50|250|40|20|120|75 / 78| |RWS600B-5|5V|4.5-5.75V|100|500|70|20|120|74 / 77| |RWS50B-12|12V|10.8-13.8V|4.3|51.6|96|48|150|82 / 84| |RWS100B-12|12V|10.8-13.8V|8.5|102|96|48|150|82 / 84| |RWS150B-12|12V|10.8-13.8V|13|156|96|48|150|84 / 87| |RWS300B-12|12V|10.8-13.8V|25|300|96|48|150|79 / 82| |RWS600B-12|12V|10.8-13.8V|50|600|96|48|150|81 / 84| |RWS300B-15|15V|13.5-17.2V|20|300|120|60|150|81 / 84| |RWS600B-15|15V|13.5-17.2V|40|600|120|60|150|81 / 84| |RWS50B-24|24V|21.6-27.6V|2.2|52.8|192|96|150|86 / 87| |RWS100B-24|24V|21.6-27.6V|4.5|108|192|96|150|85 / 87| |RWS150B-24|24V|21.6-27.6V|6.5|156|192|96|150|86 / 89| |RWS300B-24|24V|21.6-27.6V|12.5|300|192|96|150|85 / 88| |RWS600B-24|24V|21.6-27.6V|25|600|192|96|150|84 / 88| |RWS300B-36|36V|32.4-41.4|8.4|302.4|288|144|200|85 / 88| |RWS600B-36|36V|32.4-41.4|16.7|601.2|288|144|200|84 / 88| |RWS50B-48|48V|43.2-52.8|1.1|52.8|384|192|200|86 / 88| |RWS100B-48|48V|43.2-52.8|2.1|100.8|384|192|200|85 / 87| |RWS150B-48|48V|43.2-52.8|3.3|158.4|384|192|200|86 / 89| |RWS300B-48|48V|43.2-52.8|6.3|302.4|384|192|200|85 / 88| |RWS600B-48|48V|43.2-52.8|12.5|600|384|192|200|85 / 88| ## Outline Drawing (RWS600B) **==> picture [136 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> fret Ta t e<br>a<br>isFea ) ’ TI A tp qj ft e&<br>| |dn as qj (AT<br>aq a<br>b4t_(8 8) 1qi N A M E_ P<br>i — SEE NO<br>aH ee KSI<br>_ eheda |_@ Ep LGeal U? fi.be] @—<br>H V.ADJ OUTPUT :<br>+V 5 V<br>+V 100 A<br>-V<br>-VLN Pollution Degree : 2 Use wires rating at least 75°CMax. surrounding air temperature : 70°C EHFP JAPAMADE INN OUTPUT : 5 V 100 A 50-60Hz INPUT : 100-240VAC 6.5 A RWS600B-5<br>**----- End of picture text -----**<br> ## Options Suffi x Description /CO2 Double Sided Board Coating /R Remote On/Off (RWS300B only) /RFO Remote On/Off, Remote Sense, Parallel Operation, DC Good Signal (RWS600B only) ## Other TDK-Lambda Industrial Products |HWS|15W to 1500W Single output| |---|---| |LS|25W to 200W Single output low cost| |SWS-L|600W to 1000W Single output, full featured| For Additional Information, please visit us.tdk-lambda.com/lp/products/rwsb-series.htm 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 23 Revision A9: Sept 2016
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →