RWS300B-15
Power Supply Approvals:ITE
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: RWS-B Series
- No. of Outputs: 1Outputs
- Output Power Max: 300W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20A
- Output Voltage - Output 1: 15V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 90.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RWS-B Series** **www.** uk.tdk-lambda.com/rws-b **50W to 600W Single Output General Purpose Power Supplies** |**Features**|**Benefits**| |---|---| |• 10 Year e-cap Lifetime|• Better Field Reliability| |• 7 Year Warranty|• Lower Cost of Ownership| |• Global Safety Approvals|• Supports Worldwide Use| |• Compact Size|• Easier System Integration| |**Specification**|||||||| |---|---|---|---|---|---|---|---| |**Model**||**RWS50B**<br>**RWS100B**<br>**RWS150B**||||**RWS300B**|**RWS600B**| |AC Input Voltage range**(1)**|VAC||85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds|||85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds|| |Inrush Current (100 / 200VAC)|A|18 / 36<br>15 / 30<br>16 / 32||||17 / 34|20 / 40| |Power Factor (100 / 200VAC)|-||Meets EN61000-3-2||||| |Input Current (115/230VAC) (typ)|A|1.1 / 0.65<br>1.2 / 0.65<br>1.8 / 0.9<br>(5V model 0.9/0.45)<br>(5v model 1.3/0.7)|||(5v model 3.1/1.6)|3.6 / 1.9<br>(5v model 3.1/1.6)|6.6 / 3.6<br>(5v model 6.2/3.2)| |DC Input|VDC||120 - 370VDC||||120 - 330VDC| |Temperature Coefficient|-||<0.02%/°C||||| |Regulation|-||See table||||| |Overcurrent Protection|-|>105%, 5V & 12V constant current limit & hiccup autorecovery, 24V &48V constant current limit with autorecovery|||||| |Overvoltage Protection|V||115-140%, Cycle AC line to reset|115-140%, Cycle AC line to reset||115-140%, Cycle AC line to reset|| |Hold Up Time (typ at full load)|ms||20ms||||| |Leakage Current (max)|uA||750uA maximum, typically 175uA at 115VAC, 63Hz||||| |Remote Sense|-||No||||| |Remote ON/OFF Control**(4)**|-|-|-<br>-<br>-|||Option|Option| |Parallel Operation|-|-|-<br>-<br>-|||-|Option| |Operating Temperature**(1)**|-|-20° to +70°C, derate above 45°C for 50W &100W, 40°C for 150W & 50°C for 300W & 600W (see graphs below)||20° to +70°C, derate above 45°C for 50W &100W, 40°C for 150W & 50°C for 300W & 600W (see graphs below)|20° to +70°C, derate above 45°C for 50W &100W, 40°C for 150W & 50°C for 300W & 600W (see graphs below)||| |Storage Temperature|-||-30° to +75°C||||| |Operating Humidity(non condensing)%RH|%RH||30 - 90||||| |Storage Humidity(non condensing)|%RH||10 - 90||||| |Cooling|-||Convection|||Internal Fan|Internal Fan| |Withstand Voltage|-||Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.||||| |Isolation Resistance|-||>100M at 25°C & 70%RH, Output to Ground 500VDC|||>100M at 25°C & 70%RH, Output to Ground 500VDC|| |Vibration (non operating)|-||10 - 55Hz: 19.6m/s2(sweep 1 min) X, Y, Z for 1 hour|(sweep 1 min) X, Y, Z for 1 hour|(sweep 1 min) X, Y, Z for 1 hour||| |Shock|-||< 196.1 m/s2||||| |Safety Agency Approvals**(2) (3)**|-||IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1, UL508 and CE Mark||||| |Line Dips|-||SEMI-F47 (200VAC input)||||| |Conducted & Radiated EMI|-||EN55011 / EN55022-B, FCC Class B, VCCI-B||||| |Immunity|-||IEC61000-4-2, -3, -4, -5, -6, -8, -11||IEC61000-4-2, -3, -4, -5, -6, -8, -11|IEC61000-4-2, -3, -4, -5, -6, -8, -11|| |Weight (Typ)|g|230|230<br>400<br>480|||900|1600| |Size (WxHxD)|mm|82 x 34 x 81.5|82 x 34 x 81.5<br>94 x 39 x 108<br>94 x 41 x 128||102 x 41 x 170||120 x 61 x 190| |MTBF**(5)**|hours|4,170,949<br>1,978,533<br>2,235,743||||2,027,824|2,157,340| |Warranty|Yrs||7||||| **Notes: (1)** See graphs below for derating at low line input voltage **(2)** UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24 & RWS300B-24 only **(3)** Consult Sales Office for use under DC Input conditions **(4)** External 5V source required, see instruction manual for details **(5)** According to Telcordia document SR-332, issue 3, “Reliability Prediction Procedure for Electronic Equipment”. Conditions: ambient temp. 25deg C, 230Vac input, full load (figures shown for 24V models) RWS-B Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Model Selector**||||||||| |---|---|---|---|---|---|---|---|---| |||**Adjust**|**Max**|**Max**|**Load**|**Line**|**Ripple**|**Effciency**| |**Model**|**Voltage**|**Range**|**Current**|**Output**|**Reg.**|**Reg.**|**Noise**|**(typ) %**| |||**(V)**|**(A)**|**Power**|**(mV)**|**(mV)**|**(mV)**|**115/230VAC**| |RWS50B-5|5V|4.5-5.75|10|50|40|20|120|78 / 79| |RWS100B-5|5V|4.5-5.75|14|70|40|20|120|77.5 / 79| |RWS150B-5|5V|4.5-5.75|21|105|40|20|120|77.5 / 79.5| |RWS300B-5|5V|4.5-5.75|50|250|40|20|120|75 / 78.5| |RWS600B-5|5V|4.5-5.75|100|500|70|20|120|74 / 77.5| |RWS50B-12|12V|10.8-13.8|4.3|51.6|96|48|150|83 / 84| |RWS100B-12|12V|10.8-13.8|8.5|102|96|48|150|83 / 84| |RWS150B-12|12V|10.8-13.8|13|156|96|48|150|84.5 / 87.5| |RWS300B-12|12V|10.8-13.8|25|300|96|48|150|79.5 / 82.5| |RWS600B-12|12V|10.8-13.8|50|600|96|48|150|82 / 84.5| |RWS100B-15|15V|13.5-17.25|6.8|102|120|60|150|84 / 85| |RWS150B-15|15V|13.5-17.25|10|150|120|60|150|84.5 / 87.5| |RWS300B-15|15V|13.5-17.3|20|300|120|60|150|81.5 / 84.5| |RWS600B-15|15V|13.5-17.3|40|600|120|60|150|82 / 84.5| |RWS50B-24|24V|21.6-27.6|2.2|52.8|192|96|150|86 / 87| |RWS100B-24|24V|21.6-27.6|4.5|108|192|96|150|86 / 87.5| |RWS150B-24|24V|21.6-27.6|6.5|156|192|96|150|86.5 / 89.5| |RWS300B-24|24V|21.6-27.6|12.5|300|192|96|150|85 / 88| |RWS600B-24|24V|21.6-27.6|25|600|192|96|150|85 / 88.5| |RWS150B-28|28V|25.2-32.2|5.4|151.2|224|112|180|86.5 / 89.5| |RWS300B-36|36V|32.4-41.4|8.4|302.4|288|144|200|85 / 88| |RWS600B-36|36V|32.4-41.4|16.7|601.2|288|144|200|84 / 88.5| |RWS50B-48|48V|43.2-52.8|1.1|52.8|384|192|200|87 / 88| |RWS100B-48|48V|43.2-52.8|2.1|100.8|384|192|200|86 / 87| |RWS150B-48|48V|43.2-52.8|3.3|158.4|384|192|200|86.5 / 89.5| |RWS300B-48|48V|43.2-52.8|6.3|302.4|384|192|200|85 / 88| |RWS600B-48|48V|43.2-52.8|12.5|600|384|192|200|85 / 88.5| ## **Output Derating RWS50B Series** **==> picture [511 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>Mounting (A)<br>80 Mounsing (B),(C),(D)<br>Load (%)<br>60 Ta (°C) Mounting (A) Mounsing (B),(C),(D)<br>20 50 50<br>40 10 +35 100 100<br>45 100 77<br>20 50 84 65<br>60 52 42<br>70 20 20<br>0<br>20 10 0 10 20 30 40 50 60 70 80<br>Ta (℃)<br>Load (%)<br>**----- End of picture text -----**<br> ## **Output Derating RWS100B Series** **==> picture [512 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80 Mounting (A)<br>Mounsing (B),(C),(D)<br>60<br>Ta (°C) Load (%)<br>Mounting (A) Mounsing (B),(C),(D)<br>40 20 50 50<br>10 +35 100 100<br>20 45 100 68<br>60 52 20<br>0 70 20 <br>20 10 0 10 20 30 40 50 60 70 80<br>Ta (℃)<br>Load (%)<br>**----- End of picture text -----**<br> RWS-B Series 2 **==> picture [516 x 34] intentionally omitted <==** ## **Output Derating RWS150B Series** **==> picture [511 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100 Mounting (A)<br>Mounsing (B),(C),(D)<br>80<br>Load (%)<br>Ta (°C)<br>Mounting (A) Mounsing (B),(C),(D)<br>60<br>20 50 50<br>10 +20 100 100<br>40 30 100 80<br>40 100 60<br>20 50 73 40<br>60 46 20<br>0 70 20 <br>20 10 0 10 20 30 40 50 60 70 80<br>Ta (℃)<br>Output Derating RWS300B Series<br>120<br>100<br>80<br>Mounting (A)(D)<br>60<br>40 Ta ( ° C) MountinLoad g((%A))(D)<br>20 50<br>20 10 +50 100<br>60 85<br>0 70 50<br>20 10 0 10 20 30 40 50 60 70 80<br>Ta (℃)<br>Load (%)<br>Load (%)<br>**----- End of picture text -----**<br> ## **Output Derating RWS600B Series** **==> picture [511 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>Mounting (A)(D)<br>40 Load (%)<br>Ta (°C) Mounting (A)(D)<br>20 20 +50 100<br>60 75<br>0 70 50<br>20 10 0 10 20 30 40 50 60 70 80<br>Ta (℃)<br>Load (%)<br>**----- End of picture text -----**<br> ~~RWS-B Ser~~ ies 3 ## **Mounting Direction RWS-B Series** **Options Suffix Description** /CO2 Double Sided Board Coating /R Remote On/Off (RWS300B and RWS600B) /RFO Remote On/Off, Remote Sense, Parallel Operation, DC Good Signal (RWS600B only) /FO Remote Sense, Parallel Operation, DC Good Signal (RWS600B only) ## **Output Derating according to Input Voltage** **==> picture [438 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> RWS50B RWS100B, RWS150B RWS300B, RWS600B<br>/ #50 conning ; e” a; Note: Load (%) is percent of maximum current<br>value in a rated output voltage<br>**----- End of picture text -----**<br> ## **Outline Drawing RWS50B Series** **Notes:** A: Model name, input voltage range, nominal output voltage, maximum output current and country of manufacture are shown here in accordance with the specifications. B: 4 – M3 BR and countersink are for customer’s chassis mounting. (Screw penetration depth 6mm max.) RWS-B Series 4 ## **Outline Drawing RWS100B Series** - a\' 7 temenenenenenene - **Notes:** A: Model name, input voltage range, nominal output voltage, maximum output current and country of manufacture are shown here in accordance with the specifications. - B: 4 – M3 BR and countersink are for customer’s chassis mounting. (Screw penetration depth 6mm max.) ## **Outline Drawing RWS150B Series** - | i ae P ~~a~~ ta OOOO OO CR NAME_PLATE(2) = 12851 - **Notes:** A: Model name, input voltage range, nominal output voltage, po maximum output current and country of manufacture are shown here in accordance with the specifications. © - B: 4 – M3 BR and countersink are for customer’s chassis mounting. (Screw penetration depth 6mm max.) RWS-B Series 5 ## **Outline Drawing RWS300B Series** **==> picture [467 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> (pets) Ub e : Loy<br>Notes:<br>. A: Model name, input voltage range, nominal<br>output voltage, maximum output current and<br>—_ —) country of manufacture are shown here in<br>accordance with the specifications.<br>° ef<br>B: 4 – M3 BR and countersink are for customer’s<br>(|<br>chassis mounting.<br>(Screw penetration depth 6mm max.)<br>R<br>**----- End of picture text -----**<br> ## **Outline Drawing RWS600B Series** **==> picture [183 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>A: Model name, input voltage range, nominal output voltage,<br>maximum output current and country of manufacture are shown<br>here in accordance with the specifications.<br>B: 8 – M4 BR and countersink are for customer’s chassis mounting.<br>(Screw penetration depth 6mm max.)<br>**----- End of picture text -----**<br> RWS-B Series 6 ## **TDK-Lambda France SAS** 3 Avenue du Canada Parc Technopolis Bâtiment Sigma 91940 les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com ## **Italy Sales Office** Via Giacomo Matteotti 62 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com ## **Netherlands** info@nl.tdk-lambda.com www.nl.tdk-lambda.com ## **TDK-Lambda Germany GmbH** Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com ## **TDK-Lambda UK Ltd.** Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com ## **TDK-Lambda Ltd.** 1 Alexander Yanai Segula Petah-Tikva Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il ## **C.I.S.** **Commercial Support:** Tel: +7 (495) 665 2627 **Technical Support:** Tel: +7 (812) 658 0463 info@tdk-lambda.ru www.tdk-lambda.ru ## **Local Distribution** CG ## **Austria Sales Office** Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info@at.tdk-lambda.com www.de.tdk-lambda.com ## **Switzerland Sales Office** Eichtalstrasse 55 8634 Hombrechtikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@ch.tdk-lambda.com www.de.tdk-lambda.com ## **Nordic Sales Office** Haderslevvej 36B DK-6000 Kolding Denmark Tel: +45 8853 8086 info@dk.tdk-lambda.com **www.emea.tdk-lambda.com** RWS-B Series Aug19 v18 RWS-B Series 7
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →