RWS1500B36
POWER SUPPLY, AC-DC, 36V, 1.5KW
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: RWS1500B Series
- No. of Outputs: 1Outputs
- Output Power Max: 1.5kW
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 42A
- Output Voltage - Output 1: 36V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 404.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RWS1000/1500-B Series** **www.** emea.tdk-lambda.com/rws-b ## **1000W to 1500W Single Output General Purpose Power Supplies** |**Features**|**Benefits**| |---|---| |• Enclosed Compact Construction|• Easy Installation| |• Class B Conducted & Radiated EMI • Easier System Compliance|• Class B Conducted & Radiated EMI • Easier System Compliance| |• SEMI F47 Line Dips|• Better System Integrity| |• 7 Year Warranty|• Lower Cost of Ownership| |**Specification**||||| |---|---|---|---|---| |**Model**||**RWS1000B**|**RWS1500B**|| |AC Input Voltage range (1)|VAC|85 - 265VAC (47 - 63Hz)||| |DC Input Voltage range*|VDC|120 - 340VDC*||| |Inrush Current (100 / 200VAC)|A|60 / 60A|60 / 60A|| |Power Factor (100 / 200VAC)|-|Meets EN61000-3-2 (0.98 / 0.95)||| |Input Current (100/200VAC) (Typ)|A|13 / 7A|19 / 10A|| |Temperature Coefficient<br>Regulation|%/°C<br>-|<0.02%/°C<br>See Model Selector||| |Overcurrent Protection|-|>105%, Constant Current Style. After 5s unit will shutdown||| |Overvoltage Protection|V|120-145% (115-125% for 48V), Cycle AC line to reset||| |Hold Up Time (Typ at 100% load)|ms|20ms||| |Leakage Current (max)|mA|<1.2mA||| |Remote Sense|-|Yes||| |Remote On/Off|-|See options table||| |DC Good, Fan Alarm|-|See options table||| |Parallel Operation|-|See options table||| |Series Operation|-|Yes||| |Operating Temperature|°C|-20 to +60°C, derate linearly to 60% load from 50 to 60°C|-20 to +60°C, derate linearly to 60% load from 50 to 60°C|| |Storage Temperature|°C|-30 to +75°C|-30 to +75°C|| |Operating Humidity (non condensing)|%RH|10 - 90%RH||| |Storage Humidity (non condensing)|%RH|10 - 90%RH||| |Cooling|-|Internal Fan, air intake from input/output terminals||| |Withstand Voltage|VAC|Input to Ground 2kVAC, Input to Output 4kVAC, Output to Ground 1.5kVAC for 1 min.||| |Isolation Resistance|MΩ|>100MΩ at 25°C & 70%RH, Output to Ground 500VDC||| |Vibration (non operating)||10 - 55Hz: 19.6m/s2(sweep 1 min) X, Y, Z for 1 hour||(sweep 1 min) X, Y, Z for 1 hour| |Shock|-|< 196.1 m/s2||| |Safety Agency Certifications|-|UL60950-1, CSA60950, EN60950-1, CE Mark||UL60950-1, CSA60950, EN60950-1, CE Mark| |Line Dips|-|SEMI-F47 (200VAC input)||| |Conducted & Radiated EMI|-|EN55011 / EN55022-B, FCC Class B, VCCI-B||EN55011 / EN55022-B, FCC Class B, VCCI-B| |Immunity|-|IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2||| |Weight (Typ)|g|2,000g||3,000g| |Size (WxHxD)|mm|127 x 63 x 198mm|127 x 63 x 261mm|127 x 63 x 261mm| |MTBF - Telcordia SR-332 issue 3**|hours|1,834,313|1,222,361|| |Warranty|yrs|7||| **Notes:** *Safety certified for AC input only **24V output model, 25°C ambient, full load, 230VAC input (1) Derate linearly to 80% load from 90 to 85VAC input RWS1000/1500B Series 1 **==> picture [517 x 34] intentionally omitted <==** ## **Model Selector** |**Model**|**Voltage**|**Adjust Range**<br>**(V)**|**Max Current**<br>**(A)**|**Max Output**<br>**Power (w)**|**Load Reg**<br>**(mV)**|**Line Reg**<br>**(mV)**|**Ripple Noise**<br>**(mV)**|**Effciency (typ) %**<br>**115/230VAC**| |---|---|---|---|---|---|---|---|---| |RWS1000B-12|12V|10.2-13.8V|84|1008|96|48|150|82 / 85| |RWS1500B-12|12V|10.2-13.8V|125|1500|96|48|150|81 / 85| |RWS1000B-15|15V|12.8-17.2V|67|1005|120|60|150|82 / 85| |RWS1500B-15|15V|12.8-17.2V|100|1500|120|60|150|82 / 85| |RWS1000B-24|24V|20.4-27.6V|42|1008|144|96|180|85 / 88| |RWS1500B-24|24V|20.4-27.6V|63|1512|144|96|180|85 / 88| |RWS1000B-36|36V|30.6-41.4|28|1008|216|144|250|85 / 88| |RWS1500B-36|36V|30.6-41.4|42|1512|216|144|250|85 / 88| |RWS1000B-48|48V|40.8-52.8|21|1008|288|192|300|85 / 88| |RWS1500B-48|48V|40.8-52.8|32|1536|288|192|300|85 / 88| |**Options**|| |---|---| |**Suffx**|**Description**| |**/CO2**|Double Sided Board Coating| |**/R**|Remote On/Off| |**/RF**|Reverse Fan (Air exits over input/output terminals)| |**/RFO**|Remote On/Off, Parallel Operation, DC Good and Fan Alarm Signals| RWS1000/1500B Series 2 ## **RWS 1000B Outline Drawing** Cn ## **RWS 1500B Outline Drawing** Cn RWS1000/1500B Series 3 ## **TDK-Lambda France SAS** 3 Avenue du Canada Parc Technopolis Bâtiment Sigma 91940 les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com ## **Italy Sales Office** Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com ## **TDK-Lambda UK Ltd.** Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com ## **TDK-Lambda Ltd.** Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il ## **Netherlands** info@nl.tdk-lambda.com www.nl.tdk-lambda.com ## **TDK-Lambda Germany GmbH** Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com ## **C.I.S.** ## **Commercial Support:** Tel: +7 (495) 665 2627 **Technical Support:** Tel: +7 (812) 658 0463 info@tdk-lambda.ru www.tdk-lambda.ru ## **Local Distribution** Ce ## **Austria Sales Office** Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info@at.tdk-lambda.com www.de.tdk-lambda.com ## **Switzerland Sales Office** Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@ch.tdk-lambda.com www.de.tdk-lambda.com ## **Nordic Sales Office** Haderslevvej 36B DK-6000 Kolding Denmark Tel: +45 2911 9556 info@dk.tdk-lambda.com **www.emea.tdk-lambda.com** RWS1000/1500B Feb17 v2 RWS1000/1500B Series 4
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →