RWS100B12
AC-DC CONVERTER, 1 O/P, 12V, 8.5A, 102W
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: RWS-B Series
- No. of Outputs: 1Outputs
- Output Power Max: 102W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8.5A
- Output Voltage - Output 1: 12V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 50.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
## - RWS B Series ## **50-600W Single Output General Purpose Power Supplies** ## **Features** - Low Cost - Wide Range AC Input 85 - 265VAC (300VAC for 5s) - - Enclosed Construction - Compact Size - 7 Year Warranty ## **Key Market Segments & Applications** ## |**Model**||**RWS50B**|**RWS100B**<br>**RWS150B**<br>**RWS300B**<br>**RWS600B**| |---|---|---|---| |AC Input Voltage range (1)<br>DC Input Voltage range|VAC<br>VDC||85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds<br>120 - 370VDC (330VDC for RWS600B)*| |Inrush Current (100 / 200VAC)|A|18 / 36|15 / 30<br>16 / 32<br>17 / 34<br>20 / 40| |Power Factor (100 / 200VAC)|-||Meets EN61000-3-2 (0.95 / 0.9)| |Input Current (115/230VAC) (Typ)|A|1.0 / 0.65|1.2 / 0.6<br>1.8 / 0.9<br>3.6 / 1.9<br>6.6 / 3.6<br>(5V: 0.9/0.45)<br>(5V: 1.3/0.7)<br>(5V: 3.1/1.6)<br>(5V: 6.2/3.2)| |Temperature Coeffi cient<br>Regulation<br>Overcurrent Protection<br>Overvoltage Protection<br>Hold Up Time (Typ at 100% load)<br>Leakage Current (max)<br>Remote Sense<br>Operating Temperature<br>Storage Temperature<br>Operating Humidity (non condensing) %RH<br>Storage Humidity (non condensing)|-<br>-<br>-<br>V<br>ms<br>uA<br>-<br>-<br>-<br>Operating Humidity (non condensing) %RH<br>%RH|<0.02%/°C<br>See sheet 2<br>>105%, Constant Current Style<br>115-140%, Cycle AC line to reset<br>20ms (RWS50B: 15ms at 100VAC input)<br>750uA maximum, typically 175uA at 115VAC, 63Hz<br>No<br>-20 to +70oC, see note (3) and instruction manual for low temperature derating<br>-30 to +75°C<br>30 - 90%RH<br>10 - 90%RH|| |Cooling|-||Convection<br>Internal Fan| |Withstand Voltage<br>Isolation Resistance<br>Vibration (non operating)<br>Shock<br>Safety Agency Approvals (2)<br>Conducted & Radiated EMI<br>Line Dips<br>Immunity|-<br>-<br>-<br>-<br>-<br>-<br>-<br>-|Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.<br>>100M at 25°C & 70%RH, Output to Ground 500VDC<br>10 - 55Hz: 19.6m/s2(sweep 1 min) X, Y, Z for 1 hour<br>< 196.1 m/s2<br>IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1, UL508 and CE Mark<br>EN55011 / EN55022-B, FCC Class B, VCCI-B<br>SEMI-F47 (200VAC input)<br>IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2|| |Weight (Typ)<br>Size (WxHxD)<br>MTBF - Telcordia SR-332 issue 3**|g<br>mm<br>In<br>Hours|230<br>82 x 34 x 81.5<br>3.23 x 1.34 x 3.2<br>Hours<br>4,170,949|400<br>480<br>900<br>1600<br>94 x 39 x 108<br>94 x 41 x 128<br>102 x 41 x 170<br>120 x 61 x 190<br>3.7 x 1.54 x 4.25<br>3.7 x 1.61 x 5.04<br>4.02 x 1.61 x 6.7<br>4.72 x 2.4 x 7.48<br>1,978,533<br>2,235,743<br>2,027,824<br>2,157,340| |Warranty|Yrs||Seven Years| *Safety certifi ed for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input Notes: (1) See instruction manual for derating below 115VAC input (2) UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24, RWS300B-12, -15, -24, -36 & -48 RWS600B-24 only (3) RWS50-100B derates linearly above 45[o] C to 20% load at 70[o] C, 150B derates above 40[o] C and 300-600B derates above 50[o] C to 50% load at 70[o] C 1-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm 20 ## - RWS B Series ## Output Ratings **==> picture [534 x 306] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||| |---|---|---|---|---|---|---|---|---| |Adjust Range|Max Current|Max Output|Load Reg|Line Reg|Ripple Noise|Effi ciency (typ) %| |Model|Voltage|(V)|(A)|Power|(mV)|(mV)|(mV)|115/230VAC| |RWS50B-5|5V|4.5-5.75V|10|50|40|20|120|78 / 79| |RWS100B-5|5V|4.5-5.75V|14|70|40|20|120|77.5 / 79| |RWS150B-5|5V|4.5-5.75V|21|105|40|20|120|77.5 / 79.5| |RWS300B-5|5V|4.5-5.75V|50|250|40|20|120|75 / 78.5| |RWS600B-5|5V|4.5-5.75V|100|500|70|20|120|74 / 77.5| |RWS50B-12|12V|10.8-13.8V|4.3|51.6|96|48|150|83 / 84| |RWS100B-12|12V|10.8-13.8V|8.5|102|96|48|150|83 / 84| |RWS150B-12|12V|10.8-13.8V|13|156|96|48|150|84.5 / 87.5| |RWS300B-12|12V|10.8-13.8V|25|300|96|48|150|79.5 / 82.5| |RWS600B-12|12V|10.8-13.8V|50|600|96|48|150|82 / 84.5| |RWS100B-15|15V|13.5-17.25V|6.8|102|120|60|150|84 / 85| |RWS150B-15|15V|13.5-17.25V|10|150|120|60|150|84.5 / 87.5| |RWS300B-15|15V|13.5-17.2V|20|300|120|60|150|81.5 / 84.5| |RWS600B-15|15V|13.5-17.2V|40|600|120|60|150|82 / 84.5| |RWS50B-24|24V|21.6-27.6V|2.2|52.8|192|96|150|86 / 87| |RWS100B-24|24V|21.6-27.6V|4.5|108|192|96|150|86 / 87.5| |RWS150B-24|24V|21.6-27.6V|6.5|156|192|96|150|86.5 / 89.5| |RWS300B-24|24V|21.6-27.6V|12.5|300|192|96|150|85 / 88| |RWS600B-24|24V|21.6-27.6V|25|600|192|96|150|85 / 88.5| |RWS150B-28|28V|25.2-32.2V|5.4|151.2|224|112|180|86.5 / 89.5| |RWS300B-36|36V|32.4-41.4|8.4|302.4|288|144|200|85 / 88| |RWS600B-36|36V|32.4-41.4|16.7|601.2|288|144|200|84 / 88.5| |RWS50B-48|48V|43.2-52.8|1.1|52.8|384|192|200|87 / 88| |RWS100B-48|48V|43.2-52.8|2.1|100.8|384|192|200|86 / 87| |RWS150B-48|48V|43.2-52.8|3.3|158.4|384|192|200|86.5 / 89.5| |RWS300B-48|48V|43.2-52.8|6.3|302.4|384|192|200|85 / 88| |RWS600B-48|48V|43.2-52.8|12.5|600|384|192|200|85 / 88/5| **----- End of picture text -----**<br> ## Outline Drawing (RWS600B) Options Suffi x Description /CO2 Double Sided Board Coating /R Remote On/Off (RWS300B only) /RFO Remote On/Off , Remote Sense, Parallel Operation, DC Good ~~—~~ Signal (RWS600B only) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ **==> picture [257 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Other TDK-Lambda Industrial Products| |HWS|15W to 1500W Single output| |LS|25W to 200W Single output low cost| |RWS1000/1500B 1000W to 1500W Single output (including medical /ME)| |For Additional Information, please visit|Opeart|aclos| **----- End of picture text -----**<br> RWS1000/1500B 1000W to 1500W Single output (including medical /ME) For Additional Information, please visit us.tdk-lambda.com/lp/products/rwsb-series.htm 21 Revision B6: Aug 2019
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →