- Manufacturer: EBM-PAPST
- Product type: Blowers
- Blower Type:Radial; Supply Voltage:24V; Voltage Type:DC; Fan Frame Size:64.6mm; External Depth:65.5mm; Air Flow - CFM:15.1CFM; Air Flow - m3/min:-; Noise Rati 50AJ6925
- IP Rating: -
- Blower Type: Radial
- Bearing Type: Ball Bearing
- Noise Rating: 58dBA
- Power Rating: 36W
- Voltage Type: DC
- Product Range: RVE45 Series
- Air Flow - CFM: 15.1CFM
- External Depth: 65.5mm
- Fan Frame Size: 64.6mm
- Supply Voltage: 24V
- Air Flow - m3/min: -
- Power Connection Type: 4 Lead Wires
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 212.02 € |
| Current stock | 25+ |
| Lead time | 30 days |
251657216 **Product Data Sheet 8315100115** VCS0045XUGAS RVE45-3/54/2A **The engineer's choice** ebmpapst
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **RVE45-3/54/2A**
|**INDEX**|**INDEX**||
|---|---|---|
|**1**|**General ............................................................................................................................................................... 3**||
|**2**|**Mechanics .......................................................................................................................................................... 3**||
||2.1|General......................................................................................................................................................... 3|
||2.2|Connections.................................................................................................................................................. 3|
|**3**|**Operating Data ................................................................................................................................................... 5**||
||3.1|Electrical Interface - Input.............................................................................................................................. 5|
||3.2|Electrical Operating Data .............................................................................................................................. 6|
||3.3|Electrical Interface - Output........................................................................................................................... 7|
||3.4|Electrical Features ........................................................................................................................................ 8|
||3.5|Aerodynamics............................................................................................................................................... 9|
||3.6|Sound Data................................................................................................................................................. 10|
|**4**|**Environment..................................................................................................................................................... 10**||
||4.1|General....................................................................................................................................................... 10|
||4.2|Climatic Requirements................................................................................................................................ 10|
||4.3|EMC ........................................................................................................................................................... 10|
|**5**|**Safety................................................................................................................................................................ 12**||
||5.1|Electrical Safety.......................................................................................................................................... 12|
||5.2|Approval Tests............................................................................................................................................ 12|
|**6**|**Reliability.......................................................................................................................................................... 12**||
||6.1|General....................................................................................................................................................... 12|
ebmpapst
page 2 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
**1 General**
|Fantype<br>Rotating direction looking atrotor<br>Airflowdirection<br>Bearing system<br>Mounting position -shaft<br>**2**<br>**Mechanics**<br>~~S=SS ~~|Blower<br>Counterclockwise<br>Air inaxially,Airoutradially<br>Ballbearing<br>Any<br> ~~S58~~|Blower<br>Counterclockwise<br>Air inaxially,Airoutradially<br>Ballbearing<br>Any<br> ~~S58~~|
|---|---|---|
|**2.1**<br>**General**|||
|Width|64,6mm||
|Height|64,5mm||
|Depth|65,5mm||
|Diameter|57 mm||
|Mass|0,16kg||
|Housing material|FDA approved plastics for the air-conducting parts||
||(top and bottom housing) and V0 for the motor and||
||electronics cover||
|Impeller material|FDA approvedplastics||
**Connections**
|Electricalconnection<br>~~ee~~|Wires<br>~~ee~~|~~ee~~|
|---|---|---|
|Lead wire length<br>Tolerance<br>~~ee~~|L = 354 mm<br>+- 11 mm<br>~~ee~~|~~ee~~|
|Wire size (AWG)<br>~~ee~~|22<br>~~ee~~|~~ee~~|
|Insulationdiameter<br>~~ee~~|1,7 mm<br>~~ee~~|~~ee~~|
page 3 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
**==> picture [227 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wire Color<br>1 red<br>2 blue<br>3 violet<br>4 white<br>[do]<br>**----- End of picture text -----**<br>
|**Wire**<br>[do]|**Color**<br>[do]|**Operation**<br>[do]|**Wire size**|**Insulation diameter**|
|---|---|---|---|---|
|1<br>[do]|reded<br>[do]|+UB<br>[do]|AWG22|1,7 mm|
|2<br>[do]|bluelueue<br>[do]|-GND<br>[do]|AWG22|1,7 mm|
|3<br>[do]|violetoletletet<br>[do]|CTRL<br>[do]|AWG22|1,7 mm|
|4<br>[do]|whitete<br>[do]|Tacho<br>[do]|AWG22|1,7 mm|
ebmpapst
page 4 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **3 Operating Data**
## **3.1 Electrical Interface - Input**
**==> picture [364 x 408] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control input Analog<br>Features<br>Input voltage range 0 V - 10 V<br>35000 +--------+---------<br>30000 +—-—-----+---------<br>=<br>= 25000 +—______+______<br>z<br>3<br>& 20000 +—____} _______ !<br>Characteristics =<br>N<br>s<br>& 15000 -——___-—___ 4<br>10000 -+--_______+-______-<br>5000 -—--_-_+-—<br>a<br>0) 1 2 3 4 5<br>Steuerspannung/ control<br>Lifter/Fan<br>Schematics<br>**----- End of picture text -----**<br>
## **Features**
## Information to the curve:
- 0V - 0,5V: 0 1/min (corresponding to minimum speed or power) 0,5V - 1V: 3000 1/min (corresponing to minimum speed) 1V - 9V: linearly increasing curve (coming from 0V) 9V - 10V: 37.000 1/min (corresponding to maximum speed) 1V - 0,3V 3000 1/min (corresponing to minimum speed, coming from 10V) 0,3V - 0V 0 1/min (corresponding to minimum speed or power)
page 5 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
If the setpoint is set to 0V, the fan brakes from < 20,000 rpm. The fan is controlled and not regulated. The speed depends on the operating voltage and the operating point.
## **3.2 Electrical Operating Data**
Measurement Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up conditions: time before measuring 5 minutes. In the intake and outlet area should not be any solid obstruction within 0,5 m.
- ∆ p = 0: corresp. to free air flow (see chapter aerodynamics) I: corresp. to arithm. mean current value
|**Name**<br>U Contr.0001<br>~~[_~~|**Condition**<br>U Contr.: 10V|
|---|---|
|**Features**|**Condition**|**Symbol**|**Values**|**Values**|**Values**|
|---|---|---|---|---|---|
|Voltagerange||U|16V||30V|
|Nominal voltage||UN||24 V||
|Power consumption<br>Tolerance|∆p = 0<br>U Contr. 0010|P|16 W<br>+- 10 %|36 W<br>+- 10 %|37 W<br>+- 10 %|
|Current consumption<br>Tolerance|∆p = 0<br>U Contr. 0010|I|1.000 mA<br>+- 10 %|1.500 mA<br>+- 10 %|1.250 mA<br>+- 10 %|
|Speed<br>Tolerance|∆p = 0<br>U Contr. 0010|n|27.500 1/min<br>+- 10 %|36.500 1/min<br>+- 10 %|37.000 1/min<br>+- 10 %|
|Starting current<br>consumption||||<= 3.000 mA||
ebmpapst
page 6 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **3.3 Electrical Interface - Output**
Tacho type /2 (open collector)
|**Features**|**Note**|**Values**|
|---|---|---|
|Tacho operatingvoltage<br>UBS||<=30V|
|Tacho signal Low<br>US low|Isink: 2 mA|<=0,4 V|
|Tacho signal High<br>US high|Isource:0mA|<=30V|
|S high<br>Maximumsinkcurrent<br>Isink||<= 4 mA|
|Maximumsource current||0mA|
|External resistor|External resistor Ra from UBS to US required. All voltages measured<br>to GND.||
|Tachofrequency|n/ 60|616Hz@ 37.0001/min|
|Tachoisolatedfrom motor|No||
|Slew rate||=>0,5V/us|
n = revolutions per minute (1/min)
page 7 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **3.4 Electrical Features**
|Electronicfunction|Open loop speed||
|---|---|---|
|Reversed polarity protection<br>Max. residualcurrent at UN|N-CH FET<br>IF<= 1 mA||
|Lockedrotorprotection|Autorestart||
|Lockedrotorcurrent at UN|Iblock approx. 70mA||
|Clocksignalatlockedrotor|t3 / t4 typical:0,22s / 0,22s||
|Voltage control *)|Fan turns on at UB> 15 V or < 31 V<br>Fanturns offat UB< 14 Vor >32 V||
*) This fan has an undervoltage and overvoltage control circuit integrated which turns the motor off if the voltage is out of range.
ebmpapst
page 8 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **3.5 Aerodynamics**
Measurement Measured with a double chamber intake rig acc. to DIN EN ISO 5801. conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal.
The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. Power consumption of the fan motor when operating at normal voltage is shown. Depending on the operating conditions of the application, the power input may be higher.
a.) Operation condition:
|a.) Operation condition:||||||
|---|---|---|---|---|---|
|36.5001/minatfree air flow||U|Contr. 10V|||
|||||||
|Max. free-air flow(∆p=0 /|= max.)||||30m3/h|
|Max.static pressure (∆p= max./|||=0)||4.500Pa|
The fan must not be operated at < 1m3 / h.
ebmpapst
page 9 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **3.6 Sound Data**
Measurement Sound pressure level: 1 meter distance between microphone and the air intake. conditions: Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics.
## a.) Operation condition:
36.500 1/min at free air flow U Contr. 10 V
Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, 58 dB(A) measured in rubber bands ~~—<————————~~ **4 Environment 4.1 General**
Min. permitted ambient temperature TU min. -20 °C Max. permitted ambient temperature TU max. 65 °C Min. permitted storage temperature TL min. -40 °C ~~——~~ Max. permitted storage temperature TL max. 85 °C
## **4.2**
**Climatic Requirements**
Humidity requirements humid heat, constant; according to DIN EN 60068-2-78, 14 days Water exposure None Dust requirements None ~~——~~ Salt fog requirements None
## Permitted application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided.
## Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
Please require severity levels and specification parameters from the responsible development departments.
**4.3 EMC**
**Kind Electrostatic Discharge Immunity Test** According DIN EN 61000-4-2:2001-12 Ceck accuracy / Limit Contact Discharge +/- 4 kV; Air Discharge +/- 8 kV Result A: The monitored function operates as designed during and after exposure ~~oo~~ to a disturbance.
page 10 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
|**Kind**<br>**Electromagnetic Field Immunity Test**<br>According<br>DIN EN 61000-4-3:2006-12<br>Ceck accuracy/ Limit<br>10 V/m;80 - 1000 MHz;AM;m = 0,8;f = 1 kHz;1%;t = 3 s<br>Result<br>A: The monitored function operates as designed during and after exposure<br>to a disturbance.<br>~~————~~|
|---|
|**Kind**<br>**Electrical Fast Transient / Burst Immunity Test**<br>According<br>DIN EN 61000-4-4:2005-07<br>Ceck accuracy / Limit<br>+/- 2 kV on Power Lines; Coupling: POS, NEG, {PE}, ALL, 5 kHz and 100<br>kHz;1 min<br>Result<br>A: The monitored function operates as designed during and after exposure<br>to a disturbance.<br>~~—~~|
|**Kind**<br>**Immunity to Conducted Disturbances, Induced by RF-Fields**<br>According<br>DIN EN 61000-4-6:2001-12<br>Ceck accuracy/ Limit<br>10 Vrms;150 kHz - 80 MHz;AM;m = 0,8;f = 1 kHz;1%;t = 3 s<br>Result<br>A: The monitored function operates as designed during and after exposure<br>to a disturbance.<br>~~or~~|
page 11 of 13
06/11/2021
251658752 **Product Data Sheet**
**8315100115** VCS0045XUGAS RVE45-3/54/2A
## **5 Safety**
## **5.1 Electrical Safety**
|Dielectric strength<br>DIN EN 62368 and DIN EN 60335<br>A.) Type test<br>Measuring conditions: After 48h of storage at 95% R.H. and<br>25°C.<br>No arcing or breakdown is allowed!<br>All connections together to ground.<br>B.) Routine test<br>Measuring conditions: At indoor climate.<br>No arcing or breakdown is allowed!<br>All connections together toground.|500 VAC / 1 Min.<br>850 VDC / 1 Sec.||
|---|---|---|
|Isolation resistance<br>Measuring conditions: After 48h of storage at 95% R.H. and<br>25°C measured with U=500 VDC for 1 min.|RI > 10 MOhm||
|Clearance / creepage distance|1,0 mm / 1,2 mm||
|Protection class|III||
**5.2 Approval Tests** CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans E38324 VDE Association for Electrical, Electronic and Information Yes / Approval acc. to EN 62368 - Audio/video, information Technologies and communication technology equipment CSA Yes / CSA audited by UL according to C22.2 No. 113 Fans Canadian Standards Association and Ventilators ~~——_——~~ CCC China Compulsory Certification Not applicable **6 Reliability 6.1 General** Life expectancy L10 at TU = 20 °C 22.500 h Life expectancy L10 at TU = 40 °C 17.500 h Life expectancy L10 at TU max. 8.500 h Life expectancy L10 acc. to IPC 9591 at TU = 40 °C 27.5 00 h Life expectancy L10 acc. to IPC 9591 at TU = 25 °C 45.0 00 hrs ~~————~~
page 12 of 13
06/11/2021
**==> picture [473 x 661] intentionally omitted <==**
**----- Start of picture text -----**<br>
| aaa - = = ~N |<br>2 Q<br>2<br>VK AEA B<br>z Sy) w:<br>s ZL “ Se<br>alsolo vq re. 5:3<br>s £ Sn a mi Fe ° 16<br>_ 32 _<br>‘sls 20= 160<br>3| 2 we<br>\ SU —_ Ww: «OB<br>|<br>.<br>|<br>T ° \)\ NO || 7<br>g PS ceACUUl GG ci ————KH|____.<br>2 le © @) i 1h Mab.<br>ealleoes WN(~~ AVZA \ pbb———a iadl 22<br>Saige<br>Safe<br>meEILe<br>IOLOOL OS] 99!]0U UO!Ie}O1d 0}a JaJoy “UBISep Jo JapoW Aji|I}n ‘jUayed eB Jo JULIBH ay) Jo JUBAe ae pedsases $}yBiJ ||y “saBewep jo jueWAed ey) J0J 9/qeI| pjey eq ||IM<br>SI9PUGJO “Pa}!q/YOJd S| UO!JezZ|JOYINE sseidxe JNOYyIM S1BU}O 0} SJUAJUOD $}] JO UO!JBOJUNWWOD ayy Se [Jam SB JVAWNIOD S{yj JO UO!EZI|I]N pUe UO!INgUySIp ‘Uo|}oNpoldal By<br>|<br>**----- End of picture text -----**<br>
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →