RV8H-S-D12
RELAY, SPDT, 250VAC, 125VDC, 6A
- Manufacturer: IDEC
- Product type: Power Relays
- Coil Type: Non Latching
- Coil Voltage: 12VDC
- Product Range: RV8H Series
- Relay Mounting: DIN Rail
- Coil Resistance: 820ohm
- Contact Current: 6A
- Relay Terminals: Spring Clamp
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: 125VDC
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 13.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
## ag **6mm Hazardous Location Interface Relays - RV8H Series** So RA ## **Screw Terminals** ## **Spring Clamp Terminals** Top view with Marking Plate Only 70mm from DIN rail! Top view without Marking Plate Only 70mm from DIN rail! ## **Key Features** - Class 1, Division 2 and Class 1, Zone 2 hazardous locations models available - Space-saving 6mm width - Only 70mm in height from DIN rail - Gold-plated contacts - Pre-assembled relay and DIN mount socket - Universal screw terminals (flat and Phillips) or Spring clamp terminals - Universal AC/DC socket with built-in surge suppression and green LED - 6A contact rating - Lever for easy locking and removal of relay - Wide input voltage range: 6 to 240V - High dielectric strength and impulse withstand voltages - Reverse Polarity protected - 400V AC maximum switching voltage - 1500VA maximum switching power - RoHS compliant ## **Specifications** |Hazardous Location Rating<br>Number of Poles|Hazardous Location Rating<br>Number of Poles|Class 1, Division2, Groups A, B, C, D T5<br>Class 1, Zone 2, AEx nA nC IIC T4<br>Class 1, Zone 2, Ex nA nC IIC T4 X Gc<br>UL/c-UL Listed| |---|---|---| |||1 pole| |Contact Configuration||1 form C (SPDT)| |Contact material||AgNi (Au plating)| |Degree of Protection||IP20| |Dielectric<br>strength|Between contact and coil|4,000V AC for 1min| ||Between pole|1,000V AC for 1min| |Vibration<br>Resistance|Operating extremes|NO: Frequency 10 to 55Hz, Amplitude 0.5mm<br>NC: Frequency 10 to 55Hz, Amplitude 0.2mm| ||Damage limits|| |Shock<br>Resistance|Operating extremes|NO: 49m/s2(5G)<br>NC: 29.4m/s2(3G)| ||Damage limits|980m/s2(10G)| |Mechanical Life (without load)||Over 10,000,000 operations| |Operating Temperature||-25 to +55ºC without freezing| |Operating Humidity||5 to 85% (without condensation)| |Weight (approx.)||30g (RV8H-L), 26g (RV8H-S)| (when using combination of RV relay and SV socket) ## **Part Numbers** Complete Part Numbers (Relay & Socket) **==> picture [51 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>**----- End of picture text -----**<br> |**Part Numbers**<br>Complete Part Numbers (Relay & Socket)|| |---|---| |Screw Terminal<br>**New**<br>Coil voltage<br>Standard<br>Hazardous Location<br>(Class 1 Div 2)<br>~~=~~|Spring Clamp Terminal<br>**New**<br>Standard<br>Hazardous Location<br>(Class 1 Div 2)| |DC<br>6V<br>RV8H-L-D6<br>RV8H-L-D6-C1D2<br>9V<br>RV8H-L-D9<br>RV8H-L-D9-C1D2<br>12V<br>RV8H-L-D12<br>RV8H-L-D12-C1D2<br>18V<br>RV8H-L-D18<br>RV8H-L-D18-C1D2<br>24V<br>RV8H-L-D24<br>RV8H-L-D24-C1D2<br>~~=~~<br>~~ag~~|RV8H-S-D6<br>RV8H-S-D6-C1D2| ||RV8H-S-D9<br>RV8H-S-D9-C1D2| ||RV8H-S-D12<br>RV8H-S-D12-C1D2| ||RV8H-S-D18<br>RV8H-S-D18-C1D2<br>~~ag~~| ||RV8H-S-D24<br>RV8H-S-D24-C1D2<br>~~ag~~| |AC/<br>DC<br>12V<br>RV8H-L-AD12<br>RV8H-L-AD12-C1D2<br>18V<br>RV8H-L-AD18<br>RV8H-L-AD18-C1D2<br>24V<br>RV8H-L-AD24<br>RV8H-L-AD24-C1D2<br>48V<br>RV8H-L-AD48<br>RV8H-L-AD48-C1D2<br>60V<br>RV8H-L-AD60<br>RV8H-L-AD60-C1D2<br>110V - 125V<br>RV8H-L-AD110<br>RV8H-L-AD110-C1D2<br>220V - 240V<br>RV8H-L-AD220<br>RV8H-L-AD220-C1D2<br>~~ag~~|RV8H-S-AD12<br>RV8H-S-AD12-C1D2<br>~~ag~~| ||RV8H-S-AD18<br>RV8H-S-AD18-C1D2| ||RV8H-S-AD24<br>RV8H-S-AD24-C1D2| ||RV8H-S-AD48<br>RV8H-S-AD48-C1D2| ||RV8H-S-AD60<br>RV8H-S-AD60-C1D2| ||RV8H-S-AD110<br>RV8H-S-AD110-C1D2| ||RV8H-S-AD220<br>RV8H-S-AD220-C1D2| Note: When using a cut jumper, please use a spacer on the cut side. For additional information see instruction sheet. ## Replacement Parts |Replacement Parts|Replacement Parts|Replacement Parts|Replacement Parts||||| |---|---|---|---|---|---|---|---| |Screw Terminals<br>**New**<br>Complete Unit<br>Relay Only<br>Standard<br>Hazardous Location (Class 1 Div 2)<br>~~ee~~||||Spring Clamp Terminals<br>Relay Only<br>Complete Unit<br>**New**<br>Standard<br>Hazardous Location (Class 1 Div 2)<br>~~ee~~<br>~~eee~~|||| |Complete Part<br>Number<br>~~ee~~|Applicable<br>Relay<br>~~ee~~|Complete Part<br>Number<br>~~ee~~|Applicable<br>Relay<br>~~ee~~<br>~~ee~~|Complete Part<br>Number<br>~~ee~~<br>~~ee~~|Applicable<br>Relay<br>~~ee~~<br>~~ee~~|Complete Part<br>Number<br>~~ee~~<br>~~eee~~|Applicable<br>Relay| |RV8H-L-D6|RV1H-G-D5<br>RV8H-L-D6-C1D2||RV1H-G-D5-C1D2<br>~~ee~~|RV8H-S-D6<br>~~ee~~|RV1H-G-D5<br>RV8H-S-D6-C1D2<br>~~ee~~<br>~~eee~~||RV1H-G-D5-C1D2| |RV8H-L-D9|RV1H-G-D9<br>RV8H-L-D9-C1D2||RV1H-G-D9-C1D2|RV8H-S-D9|RV1H-G-D9<br>RV8H-S-D9-C1D2||RV1H-G-D9-C1D2| |RV8H-L-D12|RV1H-G-D12<br>RV8H-L-D12-C1D2||RV1H-G-D12-C1D2|RV8H-S-D12|RV1H-G-D12<br>RV8H-S-D12-C1D2||RV1H-G-D12-C1D2| |RV8H-L-D18|RV1H-G-D18<br>RV8H-L-D18-C1D2||RV1H-G-D18-C1D2|RV8H-S-D18|RV1H-G-D18<br>RV8H-S-D18-C1D2||RV1H-G-D18-C1D2| |RV8H-L-D24|RV1H-G-D24<br>RV8H-L-D24-C1D2||RV1H-G-D24-C1D2|RV8H-S-D24|RV1H-G-D24<br>RV8H-S-D24-C1D2||RV1H-G-D24-C1D2| |RV8H-L-AD12|RV1H-G-D12<br>RV8H-L-AD12-C1D2||RV1H-G-D12-C1D2|RV8H-S-AD12|RV1H-G-D12<br>RV8H-S-AD12-C1D2||RV1H-G-D12-C1D2| |RV8H-L-AD18|RV1H-G-D18<br>RV8H-L-AD18-C1D2||RV1H-G-D18-C1D2|RV8H-S-AD18|RV1H-G-D18<br>RV8H-S-AD18-C1D2||RV1H-G-D18-C1D2| |RV8H-L-AD24|RV1H-G-D24<br>RV8H-L-AD24-C1D2||RV1H-G-D24-C1D2|RV8H-S-AD24|RV1H-G-D24<br>RV8H-S-AD24-C1D2||RV1H-G-D24-C1D2| |RV8H-L-AD48|RV1H-G-D48<br>RV8H-L-AD48-C1D2||RV1H-G-D48-C1D2|RV8H-S-AD48|RV1H-G-D48<br>RV8H-S-AD48-C1D2||RV1H-G-D48-C1D2| |RV8H-L-AD60|RV1H-G-D60<br>RV8H-L-AD60-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD60|RV1H-G-D60<br>RV8H-S-AD60-C1D2||RV1H-G-D60-C1D2| |RV8H-L-AD110|RV1H-G-D60<br>RV8H-L-AD110-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD110|RV1H-G-D60<br>RV8H-S-AD110-C1D2||RV1H-G-D60-C1D2| |RV8H-L-AD220|RV1H-G-D60<br>RV8H-L-AD220-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD220|RV1H-G-D60<br>RV8H-S-AD220-C1D2||RV1H-G-D60-C1D2| ## Marking Plates |Item|||Part Number|Engraving||Part Number<br>Engraving| |---|---|---|---|---|---|---| ||||SV9Z-PW10|blank||SV9Z-PW10-jA-J<br>A-J| |Vertical Orientation<br>Horizontal Orientation<br>SV9Z-PW10-j1-10<br>1-10<br>SV9Z-PW10-jK-T<br>K-T<br>SV9Z-PW10-j11-20<br>11-20<br>SV9Z-PW10-jU-Z<br>U-Z<br>SV9Z-PW10-j21-30<br>21-30<br>SV9Z-PW10-jGROUND<br>GROUND<br>SV9Z-PW10-j31-40<br>31-40<br>SV9Z-PW10-jAC<br>AC<br>SV9Z-PW10-j41-50<br>41-50<br>1. In place ofjinsert orientation code:<br>V=Vertical, H=Horizontal<br>2. Each unit has 10 pieces (marking<br>plates).<br>SV9Z-PW10-j51-60<br>51-60<br>SV9Z-PW10-j61-70<br>61-70<br>]<br>‘| ~~ee~~<br>3<br>|<br>i<br>aif<br>i ~~po~~<br>OI<br>p |~~t~~<br>ai<br>~~Pl Eee~~<br>~~ee~~<br>F|<br>mi,<br>|<br>6!<br>o|<br>~~PMA~~<br>nd<br>Fs<br>=!<br>|||||||| ||||SV9Z-PW10-j71-80|71-80||| ||||SV9Z-PW10-j81-90|81-90||| ||||SV9Z-PW10-j91-100|91-100||| ## **Coil Ratings** |Rated Voltage|Rated Voltage|Rated Current<br>+-15% (mA)|Circuit<br>AC Resistance<br>+-10% (Ω)|Circuit<br>DC Resistance<br>+-10% (Ω)|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Power<br>Consumption| |---|---|---|---|---|---|---|---|---| ||6V|35|-|170||||0.21W| ||9V|18.6|-|485||||0.2W| |DC|12V|14.6|-|820|||110%|0.2W| ||18V|11.6|-|1550||||0.2W| ||24V|10.6|-|2270||||0.25W| ||12V<br>18V|15.5<br>13.3|755<br>1365|800<br>1345|90% max|7% min||0.2W<br>0.25W| ||24V|13.7|1730|1790||||0.33W| |AC/DC|48V|4|11880|12230|||110%|0.2W| ||60V|3.4|17600|17910||||0.2W| ||110V - 125V|3.4 - 3.9|31790 - 31890|32450 - 32900||||0.5W| ||220V - 240V|3.3 - 3.6|65670 - 66070|65940 - 68570||||0.85W| ## **Contact Ratings** |Allowable contact power|Resistive load|1500VA, 180W DC| |---|---|---| |Rated Load|Resistive load|250V AC 6A, 30V DC 6A| |Allowable Switching Current||6A| |Allowable Switching Voltage||400V AC, 125V DC| |Allowable Switching Power||1500VA, 180W DC| |Minimum Applicable Load||6V DC/10mA| ## **RV1H Relay** ## **Contact Ratings** **Maximum Switching Power AC** **Maximum Switching Power DC** **==> picture [87 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive<br>|<br>Inductive<br>|<br>7<br>are)<br>Contact Voltage (V)<br>Contact Current (A)<br>**----- End of picture text -----**<br> **==> picture [96 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> AC Resistive load<br>AC Inductive load (p. f=0.35)<br>|<br>.<br>0.<br>10 20 30 100 200<br>Contact Voltage (V)<br>Contact Current (A)<br>**----- End of picture text -----**<br> **==> picture [90 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> j=<br>DC Resistive load<br>DC Inductive load<br>7 (L/R = 56ms)<br>nw<br>Contact Voltage (V)<br>Contact Current (A)<br>**----- End of picture text -----**<br> ## **Dimensions (mm)** **==> picture [174 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> RV1H-G Relay<br>28<br>| | | i U<br>1.2 0.5 1<br>5 0.9 5.04 5.04<br>3.78 16.38<br>li<br>15.0<br>0.5<br>3.5<br>**----- End of picture text -----**<br> Note: Drawings are not to scale. SV1H-07L Screw Terminal **==> picture [239 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> A1(+) Coil 14 NO<br>11 (13+) COM<br>A2(-) Coil<br>=<br>12 NC<br>| h /t<br>35 6.1<br>|___d 88 |<br>69.6<br>74.2<br>**----- End of picture text -----**<br> ## **Internal Connection (bottom view)** **==> picture [228 x 376] intentionally omitted <==** **----- Start of picture text -----**<br> A1 A2 12 11 14<br>(13+)<br>SV9Z-SA2W<br>35<br>-— 96.7 2<br>SV9Z-PW10<br>3 Cut<br>le 1 86.5 6<br>SV9Z-J20*<br>115.9<br>6.1<br>i+]<br>120 2.8<br>——<br>66.8<br>71.4<br>16.5<br>10.5<br>6 12.3<br>**----- End of picture text -----**<br> **==> picture [113 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> RV8H-S Spring Clamp Terminal<br>**----- End of picture text -----**<br> **==> picture [228 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> 14 NO<br>A1(+) Coil<br>11 (13+) COM<br>A2(-) Coil<br>2 12 (NC) Al F<br>UU SS 8 i<br>Marking Plate Placement<br>**----- End of picture text -----**<br> *Available in black, gray and blue. IDEC Corporation • 1175 Elko Drive • Sunnyvale, CA 94089 • 800-262-IDEC (4332) • Fax: 408-745-5258 • www.IDEC.com/usa ©2013 IDEC Corporation. All Rights Reserved. RV9Y-DS100-2 08/13
Updated at February 9, 2023
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.