RV8H-L-D24-C1D2
RELAY, SPDT, 250VAC, 30VDC, 6A
- Manufacturer: IDEC
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:24VDC; Contact Current:6A; Product Range:RV8H Series; Relay Mounting:Socket; Coil Type:Non Latching; Contact Voltage VAC:250V; 23X4851
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: RV8H Series
- Relay Mounting: Socket
- Coil Resistance: 2.27kohm
- Contact Current: 6A
- Relay Terminals: Quick Connect
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 16.23 € |
| Current stock | 25+ |
| Lead time | 30 days |
## ag **6mm Hazardous Location Interface Relays - RV8H Series** So RA ## **Screw Terminals** ## **Spring Clamp Terminals** **==> picture [186 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Top view with<br>Marking Plate<br>Only 70mm from DIN rail!<br>**----- End of picture text -----**<br> **==> picture [214 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Top view without<br>Marking Plate Only 70mm from DIN rail!<br>**----- End of picture text -----**<br> ## **Key Features** - Class I, Division 2 and Class I, Zone 2 hazardous locations - Space-saving 6mm width - Only 70mm in height from DIN rail - Gold-plated contacts - Pre-assembled relay and DIN mount socket - Universal screw terminals (flat and Phillips) or Spring clamp terminals - Universal AC/DC socket with built-in surge suppression and green LED - 6A contact rating - Lever for easy locking and removal of relay - Wide input voltage range: 6 to 240V - High dielectric strength and impulse withstand voltages - Operating Temperature: -40C ~ +70C - Reverse Polarity protected - 400V AC maximum switching voltage - 1500VA maximum switching power - RoHS compliant ## **Specifications** |Hazardous Location Rating<br>Number of Poles|Hazardous Location Rating<br>Number of Poles|Class I, Division2, Groups A, B, C, D T4A<br>Class I, Zone 2, AEx nA nC IIC T4<br>Class I, Zone 2, Ex nA nC IIC T4 X Gc<br>UL/c-UL Listed| |---|---|---| |||1 pole| |Contact Configuration||1 form C (SPDT)| |Contact material||AgNi (Au plating)| |Degree of Protection||IP20| |Dielectric<br>strength|Between contact and coil|4,000V AC for 1min| ||Between pole|1,000V AC for 1min| |Vibration<br>Resistance|Operating extremes|NO: Frequency 10 to 55Hz, Amplitude 0.5mm<br>NC: Frequency 10 to 55Hz, Amplitude 0.2mm| ||Damage limits|| |Shock<br>Resistance|Operating extremes|NO: 49m/s2(5G)<br>NC: 29.4m/s2(3G)| ||Damage limits|980m/s2(10G)| |Mechanical Life (without load)||Over 10,000,000 operations<br>(operation frequency 18,000 operations per hour)| |Operating Temperature||-40 to +70ºC without freezing<br>(-40 to +55ºC for AD110 and AD220 coil voltages)| |Operating Humidity||5 to 85% (without condensation)| |Weight (approx.)||30g (RV8H-L), 26g (RV8H-S)| (when using combination of RV relay and SV socket) ## **Part Numbers** Complete Part Numbers (Relay & Socket) and Replacement Relay |**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay|**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay|**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay|**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay|**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay|**Part Numbers**<br>Complete Part Numbers (Relay & Socket) and Replacement Relay||||| |---|---|---|---|---|---|---|---|---|---| |Screw Terminals<br>**New**<br>Complete Unit<br>Relay Only<br>Coil voltage<br>Standard<br>Hazardous Location (Class I Div 2)<br>Complete Part<br>Number<br>Replacement<br>(Relay Only)<br>Complete Part<br>Number<br>Replacement<br>(Relay Only)||||||Spring Clamp Terminals<br>Relay Only<br>Complete Unit<br>**New**<br>Standard<br>Hazardous Location (Class I Div 2)<br>a3<br>ie<br>_|||| |||Complete Part<br>Number|Replacement<br>(Relay Only)|Complete Part<br>Number|Replacement<br>(Relay Only)|Complete Part<br>Number|Replacement<br>(Relay Only)|Complete Part<br>Number|Replacement<br>(Relay Only)| |DC|6V<br>RV8H-L-D6||RV1H-G-D5<br>RV8H-L-D6-C1D2||RV1H-G-D5-C1D2|RV8H-S-D6|RV1H-G-D5<br>RV8H-S-D6-C1D2||RV1H-G-D5-C1D2| ||9V<br>RV8H-L-D9||RV1H-G-D9<br>RV8H-L-D9-C1D2||RV1H-G-D9-C1D2|RV8H-S-D9|RV1H-G-D9<br>RV8H-S-D9-C1D2||RV1H-G-D9-C1D2| ||12V<br>RV8H-L-D12||RV1H-G-D12<br>RV8H-L-D12-C1D2||RV1H-G-D12-C1D2|RV8H-S-D12|RV1H-G-D12<br>RV8H-S-D12-C1D2||RV1H-G-D12-C1D2| ||18V<br>RV8H-L-D18||RV1H-G-D18<br>RV8H-L-D18-C1D2||RV1H-G-D18-C1D2|RV8H-S-D18|RV1H-G-D18<br>RV8H-S-D18-C1D2||RV1H-G-D18-C1D2| ||24V<br>RV8H-L-D24||RV1H-G-D24<br>RV8H-L-D24-C1D2||RV1H-G-D24-C1D2|RV8H-S-D24|RV1H-G-D24<br>RV8H-S-D24-C1D2||RV1H-G-D24-C1D2| |AC/DC|12V<br>RV8H-L-AD12||RV1H-G-D12<br>RV8H-L-AD12-C1D2||RV1H-G-D12-C1D2|RV8H-S-AD12|RV1H-G-D12<br>RV8H-S-AD12-C1D2||RV1H-G-D12-C1D2| ||18V<br>RV8H-L-AD18||RV1H-G-D18<br>RV8H-L-AD18-C1D2||RV1H-G-D18-C1D2|RV8H-S-AD18|RV1H-G-D18<br>RV8H-S-AD18-C1D2||RV1H-G-D18-C1D2| ||24V<br>RV8H-L-AD24||RV1H-G-D24<br>RV8H-L-AD24-C1D2||RV1H-G-D24-C1D2|RV8H-S-AD24|RV1H-G-D24<br>RV8H-S-AD24-C1D2||RV1H-G-D24-C1D2| ||48V<br>RV8H-L-AD48||RV1H-G-D48<br>RV8H-L-AD48-C1D2||RV1H-G-D48-C1D2|RV8H-S-AD48|RV1H-G-D48<br>RV8H-S-AD48-C1D2||RV1H-G-D48-C1D2| ||60V<br>RV8H-L-AD60||RV1H-G-D60<br>RV8H-L-AD60-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD60|RV1H-G-D60<br>RV8H-S-AD60-C1D2||RV1H-G-D60-C1D2| ||110V - 125V<br>RV8H-L-AD110||RV1H-G-D60<br>RV8H-L-AD110-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD110|RV1H-G-D60<br>RV8H-S-AD110-C1D2||RV1H-G-D60-C1D2| ||220V - 240V<br>RV8H-L-AD220||RV1H-G-D60<br>RV8H-L-AD220-C1D2||RV1H-G-D60-C1D2|RV8H-S-AD220|RV1H-G-D60<br>RV8H-S-AD220-C1D2||RV1H-G-D60-C1D2| ## Accessories |Description|Color|Part Number| |---|---|---| |Jumper (20 combsNote 1)<br>Rated current: 6A Note 2<br>Black<br>Gray<br>Blue<br>Ne||SV9Z-J20B| |||SV9Z-J20W| |||SV9Z-J20S| |Spacer (circuit separator)Note 3<br>-||SV9Z-SA2W| |Screwdriver<br>-||BC1S-SD0| 1. Jumper combs come with 20 points, if shorter lengths are needed simply cut off the excess points. 2. Ensure that the total current to the jumper does not exceed the overall rated current. 3. Width of spacer: 2mm ## Marking Plates (Blank and Pre-marked) |Item|Part Number|Engraving| |---|---|---| |Vertical Orientation<br>Horizontal Orientation<br>SV9Z-PW10<br>SV9Z-PW10-j1-10<br>SV9Z-PW10-j11-20<br>SV9Z-PW10-j21-30<br>SV9Z-PW10-j31-40<br>SV9Z-PW10-j41-50<br>SV9Z-PW10-j51-60<br>SV9Z-PW10-j61-70<br>SV9Z-PW10-j71-80<br>SV9Z-PW10-j81-90<br>SV9Z-PW10-j91-100<br>SV9Z-PW10-jA-J<br>SV9Z-PW10-jK-T<br>SV9Z-PW10-jU-Z<br>SV9Z-PW10-jGROUND<br>SV9Z-PW10-jAC<br>Fta<br>oO)<br>a<br>Aj|<br>|<br>‘|<br>ll<br>|<br>|<br>|||blank| |||1-10| |||11-20| |||21-30| |||31-40| |||41-50| |||51-60| |||61-70| |||71-80| |||81-90| |||91-100| |||A-J| |||K-T| |||U-Z| |||| |||| 1. In place of j insert orientation code: V=Vertical, H=Horizontal 2. Each unit has 10 pieces (marking plates). 4. When using a cut jumper, please use a spacer on the cut side. For additional information see instruction sheet. ## **Coil Ratings** |Rated Voltage|Rated Voltage|Rated Current<br>+-15% (mA)|Circuit<br>AC Resistance<br>+-10% (Ω)|Circuit<br>DC Resistance<br>+-10% (Ω)|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Operating Characteristics<br>Pickup<br>Voltage<br>Dropout<br>Voltage<br>Maximum<br>Allowable voltage|Power<br>Consumption| |---|---|---|---|---|---|---|---|---| ||6V|35|-|170||||0.21W| ||9V|18.6|-|485||||0.2W| |DC|12V|14.6|-|820|||110%|0.2W| ||18V|11.6|-|1550||||0.2W| ||24V|10.6|-|2270||||0.25W| ||12V<br>18V|15.5<br>13.3|755<br>1365|800<br>1345|90% max|7% min||0.2W<br>0.25W| ||24V|13.7|1730|1790||||0.33W| |AC/DC|48V|4|11880|12230|||110%|0.2W| ||60V|3.4|17600|17910||||0.2W| ||110V - 125V|3.4 - 3.9|31790 - 31890|32450 - 32900||||0.5W| ||220V - 240V|3.3 - 3.6|65670 - 66070|65940 - 68570||||0.85W| ## **Contact Rating** |Max. Allowable Contact Power|Resistive load|1500VA, 180W DC| |---|---|---| |Rated Load|Resistive load|250V AC 6A, 30V DC 6A| |Allowable Switching Current||6A| |Allowable Switching Voltage||400V AC, 125V DC| |Allowable Switching Power||1500VA, 180W DC| |Minimum Applicable Load||6V DC/10mA| ## **RV1H Relay** **==> picture [458 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Contact Ratings Maximum Switching Power AC Maximum Switching Power DC<br>er es QO OO |<br>> 5 | Resistive 5 aele0 AC Resistive load a 5 aeeaes QO Wee OO<br>; Inductive , INGE AC Inductive load (p. f=0.35) ;A ee<br>LH | IIE ALT ENTE<br>~ Coo 05<br>[PINE DC Resistive load<br>DC Inductive load<br>(L/R = 56ms)<br>arr ) 2 30 100 200 300 400 a 10 20 30 100 200 300 400 O. 1 0 Ww | 100<br>Contact Voltage (V) Contact Voltage (V) Contact Voltage (V)<br>Contact Current (A) Contact Current (A) Contact Current (A)<br>**----- End of picture text -----**<br> ## 800.262.4332 www.IDEC.com/relays ## **Dimensions (mm)** **==> picture [481 x 556] intentionally omitted <==** **----- Start of picture text -----**<br> RV1H-G Relay SV1H-07L Screw Terminals<br>28<br>A1(+) Coil 14 NO<br>11 (13+) COM<br>A2(-) Coil<br>1.2 0.5 1<br>5 0.9 5.04 5.04<br>3.78 16.38 12 NC<br>35 6.1<br>Note: Drawings are not to scale. 88<br>pT<br>SV9Z-SA2W RV8H-S Spring Clamp Terminals<br>14 NO<br>A1(+) Coil<br>11 (13+) COM<br>A2(-) Coil<br>12 (NC)<br>35<br>al 96.7 2 NG S|<br>a<br>SV9Z-PW10* Marking Plate Placement<br>3 Cut<br>lL 1 86.5 L.| 6 RV8H<br>.<br>*Available blank or pre-marked.<br>SV9Z-J20*<br>115.9<br>6.1<br>— os<br>120 2.8<br>ee enBp oop<br>*Available in black, gray and blue.<br>15.0 69.6<br>74.2<br>0.5<br>3.5<br>66.8<br>71.4<br>16.5<br>10.5<br>6 12.3<br>**----- End of picture text -----**<br> ## **Internal Connection (bottom view)** **==> picture [123 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> A1 A2 12 11 14<br>(13+)<br>**----- End of picture text -----**<br> IDEC Corporation • 1175 Elko Drive • Sunnyvale, CA 94089 • 800-262-IDEC (4332) • Fax: 408-745-5258 • www.IDEC.com/usa ©2013 IDEC Corporation. All Rights Reserved. _08/13 PDF only_
Updated at June 5, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →