RU2S-D24
Power Relay, DPDT, 24 VDC, 10 A, RU Series, Socket, Non Latching
- Manufacturer: IDEC
- Product type: Power Relays
- SVHC: No SVHC (15-Jan-2019)
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: RU Series
- Relay Mounting: Socket
- Coil Resistance: 605ohm
- Contact Current: 10A
- Relay Terminals: Plug In
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 5.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Relays & Sockets**
**RU**
## **RU Series Universal Relays**
## **Key features:**
- Full featured universal miniature relays
- Designed with environment taken into consideration
- Two terminal styles: plug-in and PCB mount
- Non-polarized LED indicator
- No internal wires, lead-free construction
- Cadmium-free contacts
- Mechanical flag indicator
- Manual latching lever with color coding for AC or DC coil
- Snap-on yellow marking plate; optional marking plates are available in four other colors
- Maximum contact ratings: 10A (RU2), 6A (RU4), 3A (RU42)
- UL Recognized, CSA Certified, EN Compliant
**==> picture [29 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
EN61810-1<br>**----- End of picture text -----**<br>
## **With Latching or Momentary Lever**
## Latching and Momentary Lever
Mechanical Indicator* The contact position can be confirmed through the five small windows.
## Marking Plate
Standard yellow marking plate is easily replaced with optional marking plates in four colors for easy identification of relays.
## LED Indicator*
Non-polarized green LED indicator is standard provision for plug-in terminal, latching lever types
## **Standard (without lever)**
Using the lever, operation can be checked without energizing the coil. The lever is color coded for AC and DC coils.
**==> picture [169 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
Latching Momentary<br>AC coil: Orange Red<br>DC coil: Green Blue<br>In Normal Operation<br>Note: Turn off the power to the relay coil when using the latching<br>lever. After checking the operation, return the latching lever<br>in the normal position.<br>**----- End of picture text -----**<br>
AC/DC Color Marking For identification of AC or DC coils.
AC coil: Yellow DC coil: Blue
Mechanical Indicator*
## Marking Plate
## LED Indicator*
Non-polarized green LED indicator is standard provision for plug-in terminal types.
*Not available on PCB type.
**AC Coil**
**DC Coil**
|Coil Voltage|Tape Color|
|---|---|
|24V AC<br>100 to 110V AC<br>110 to 120V AC<br>200 to 220V AC<br>220 to 240V AC<br>24V DC<br>6V DC<br>12V DC<br>48V DC<br>110V DC<br>||White<br>Clear<br>Blue<br>Black<br>Red<br>Green<br>Voltage marking on<br>yellow tape<br>||
## —ipeEc
1705151135
**www.IDEC.com**
890
**Relays & Sockets**
**RU**
## **Part Number Selection**
|Contact<br>DPDT (10A)|Contact<br>DPDT (10A)|Model<br>Standard|Standard<br>RU2S-C-0|Part Number<br>With Latching Lever<br>RU2S-0||With Momentary Lever<br>RU2S-M-0|Coil Voltage Code<br>**(Standard Stock in bold)**<br>A24,**A110**,**A220**<br>D6, D12,**D24**, D48, D110|Coil Voltage Code<br>**(Standard Stock in bold)**<br>A24,**A110**,**A220**<br>D6, D12,**D24**, D48, D110|Coil Voltage Code<br>**(Standard Stock in bold)**<br>A24,**A110**,**A220**<br>D6, D12,**D24**, D48, D110|
|---|---|---|---|---|---|---|---|---|---|
|||With RC (AC coil only)|RU2S-CR-0|RU2S-R-0||RU2S-MR-0|A110, A220|A110, A220||
|||With diode (DC coil only)|RU2S-CD-0|RU2S-D-0||RU2S-MD-0|D6, D12,**D24**, D48, D110|||
|4PDT (6A)|4PDT (6A)|PCB<br>Standard<br>With RC (AC coil only)|RU2V-NF-0<br>RU4S-C-0<br>RU4S-CR-0|—<br>RU4S-0<br>RU4S-R-0||—<br>RU4S-M-0<br>RU4S-MR-0|A24, A110, A220<br>D6, D12,**D24**, D48, D110<br>A24,**A110**,**A220**<br>D6, D12,**D24**, D48, D110<br>A110, A220|||
|||With diode (DC coil only)|RU4S-CD-0|RU4S-D-0||RU4S-MD-0|D6, D12, D24, D48, D110||D6, D12, D24, D48, D110|
|4PDT Bifurcated (3A)|4PDT Bifurcated (3A)|PCB<br>Standard<br>With RC (AC coil only)<br>With diode (DC coil only)|RU4V-NF-0<br>RU42S-C-0<br>RU42S-CR-0<br>RU42S-CD-0|—<br>RU42S-0<br>RU42S-R-0<br>RU42S-D-0||—<br>RU42S-M-0<br>RU42S-MR-0<br>RU42S-MD-0|A24,**A110**, A220<br>D6, D12,**D24**, D48, D110<br>A24, A110, A220<br>D6, D12,**D24**, D48, D110<br>A110, A220<br>D6, D12, D24, D48, D110|||
|||PCB|RU42V-NF-0|—||—|A24, A110, A220<br>D6, D12,**D24**, D48, D110|||
|||||||||||
|A|1. Plug-in terminal models have an LED indicator and a mechanical indicator as standard.<br>2. PCB models do not have an LED indicator or a mechanical indicator.||||**Ordering Information**<br>When ordering, specify the Part No. and coil voltage code:|||||
|||||||(example) **RU2S-C A110**<br>Part No. Coil Voltage Code||**A110**<br>Part No. Coil Voltage Code|Part No. Coil Voltage Code|
## **Coil Voltage Table**
|**Coil Voltage Code**|A24<br>24V AC|A110<br>110-120V AC|A220<br>220-240V AC|D6<br>6V DC|D12<br>12V DC|D24<br>24V DC|D48<br>48V DC|D110<br>110V DC|
|---|---|---|---|---|---|---|---|---|
|**Coil Rating**|||||||||
## **Sockets**
**==> picture [359 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
Spring Clamp Standard DIN Finger-safe DIN<br>Relays Panel Mount PCB Mount<br>DIN Rail Mount Rail Mount Rail Mount<br>SM2S-61<br>RU2S (DPDT) SU2S-11L SM2S-05 SM2S-05C<br>SM2S-62<br>SY4S-51<br>RU4S (4PDT) SY4S-61<br>SU4S-11L SY4S-05 SY4S-05C<br>RU42S (4PDT) SY4S-62<br>**----- End of picture text -----**<br>
1705151135
**800-262-IDEC** (4332) • USA & Canada
891
**Relays & Sockets**
**RU**
## **Hold Down Springs & Clips**
**Hold Down Springs & Clips** For Through For DIN Appearance Item Relay Panel & PCB Mount Socket Mount Socket Pullover Wire RU2S/RU4S/ SY4S-02F1 SY4S-51F1 Spring RU42S Leaf Spring RU2S/RU4S/ SFA-202* SFA-302* aS (side latch) RU42S Leaf Spring RU2S/RU4S/ SFA-101* SFA-301* ~~>~~ (top latch) RU42S Note: Order 2 pieces for each relay **Accessories** Name Part Number Color Code * Marking Plate RU9Z-P* A (orange), G (green), S (blue), W (white), Y (yellow) ~~a~~ Specify a color code when ordering. The marking plate can be removed from the relay by inserting a flat screwdriver under the marking plate. ~~7:~~ **Specifications** Model (Contact) RU2 (DPDT) RU4 (4PDT) RU42 (4PDT-bifurcated) ~~es~~ Contact Material Silver alloy Silver (gold clad) Silver-nickel (gold clad)
|Model (Contact)<br>~~7:es~~|RU2 (DPDT)<br>~~es~~|RU4 (4PDT)<br>~~es~~|RU42 (4PDT-bifurcated)<br>~~es~~|
|---|---|---|---|
|Contact Material<br>Contact Resistance1<br>Minimum<br>Applicable Load2<br>Operating Time3<br>Release Time3<br>Power Consumption<br>Insulation Resistance<br>Dielectric Strength<br>~~es~~<br>|<br>||Silver alloy<br>Silver (gold clad)<br>Silver-nickel (gold clad)<br>50 mΩ maximum<br>24V DC, 5 mA<br>(reference value)<br>1V DC, 1 mA<br>1V DC, 0.1 mA<br>20 ms maximum<br>20 ms maximum<br>AC: 1.1 to 1.4VA (50 Hz), 0.9 to 1.2VA (60 Hz) DC: 0.9 to 1.0W<br>100MΩ minimum (500V DC megger)<br>Between contact and coil: 2500V AC, 1 minute<br>Between contacts of different poles:<br>2500V AC, 1 minute<br>2000V AC, 1 minute<br>Between contacts of the same pole: 1000V AC, 1 minute<br>Electrical: 1800 operations/h maximum<br>Mechanical: 18,000 operations/h maximum<br>Damage limits: 10 to 55 Hz, amplitude 0.5 mm<br>Operating extremes: 10 to 55 Hz, amplitude 0.5 mm<br>Damage limits: 1000 m/s2(100G)<br>Operating extremes: 150 m/s2(15G)<br>AC: 50,000,000 operations<br>DC: 100,000,000 operations<br>50,000,000 operations<br>See table on page 894<br>PCB model: –55 to +70°C (no freezing)<br>Blade model: –55 to +60°C (no freezing)<br>5 to 85% RH (no condensation)<br>Approx. 35g<br>~~es~~<br>|<br>|<br>|<br>||||
|Operating Frequency<br>Vibration Resistance<br>Shock Resistance<br>Mechanical Life<br>Electrical Life4<br>Operating<br>Temperature5<br>Operating Humidity<br>Weight<br>|||||
4. Contact Load and Electrical Life (at ambient temperature 20°C)
1. Measured using 5V DC, 1A voltage drop method
2. Measured at operating frequency of 120 operations/min (failure rate level P, reference value)
5. Measured at the rated voltage.
3. Measured at the rated voltage (at 20°C), excluding contact bouncing;
- Release time of AC relays with RC: 25 ms maximum Release time of DC relays with diode: 40 ms maximum
**==> picture [54 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
—ipeEc<br>**----- End of picture text -----**<br>
1705151135
**www.IDEC.com**
892
**Relays & Sockets**
**RU**
## **Accessories**
|Item<br>Appearance<br>Aluminum<br>DIN Rail<br>(1 meter length)|Item<br>Appearance<br>Aluminum<br>DIN Rail<br>(1 meter length)|Use with<br>All DIN rail sockets|Part No.<br>Remarks<br>BNDN1000<br>The BNDN1000 is designed to accommodate DIN mount sockets.<br>Made of durable extruded aluminum, the BNDN1000 measures 0.413<br>(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard<br>length is 39” (1,000mm).|
|---|---|---|---|
|DIN Rail End<br>Stop<br>Replacement<br>Hold-Down<br>Spring Anchor||DIN rail<br>Horseshoe clip for DIN rail<br>sockets|BNL5<br>9.1 mm wide.<br>Y778-011<br>For use on DIN rail mount socket when using pullover wire hold down<br>spring. 2 pieces included with each socket.|
|**Coil Ratings**||||
|Rated Voltage (V)<br>AC<br>(50/60 Hz)<br>24<br>110-120<br>220-240|Coil<br>Voltage<br>Code<br>A24<br>A110<br>A220|Rated Current (mA)<br>±15% (at 20°C)<br>Coil Resistance (Ω)<br>±10% (at 20°C)<br>Operating Characteristics (values at 20°C)<br>50 Hz<br>60 Hz<br>Maximum Continuous<br>Applied Voltage<br>Pickup Voltage<br>Dropout Voltage<br>49.3<br>42.5<br>164<br>110%<br>80% maximum<br>30% minimum<br>8.4-10.0<br>7.1-8.2<br>4,550<br>4.2-5.0<br>3.6-4.2<br>18,230||
|DC<br>6<br>12<br>24<br>48<br>110|D6<br>D12<br>D24<br>D48<br>D110|155<br>40<br>80<br>160<br>44.7<br>605<br>18<br>2,560<br>8.9<br>12,100|110%<br>80% maximum<br>10% minimum|
## **Coil Ratings**
1. The rated current includes the current of the LED indicator.
## **Surge Suppressor Ratings**
|Model|Model|Ratings|
|---|---|---|
|AC Coil<br>DC Coil|With RC<br>With Diode|RC series circuit<br>R: 20 kΩ, C: 0.033 µF<br>Diode reverse voltage: 1000V<br>Diode forward current: 1A|
## **UL and c-UL Ratings**
|Voltage<br>~~ef~~<br>~~—~~|Resistive<br>~~efff~~|Resistive<br>~~efff~~|Resistive<br>~~efff~~|General Use<br>~~ffPPPp~~|General Use<br>~~ffPPPp~~|General Use<br>~~ffPPPp~~|Horse Power Rating<br>~~Pp~~|Horse Power Rating<br>~~Pp~~|Horse Power Rating<br>~~Pp~~|
|---|---|---|---|---|---|---|---|---|---|
||RU2<br>10A<br>10A<br>~~ef~~<br>~~—~~|RU4<br>—<br>6A<br>~~ef ff~~|RU42<br>3A<br>3A<br>~~ff~~|RU2<br>—<br>—<br>~~ff PP~~|RU4<br>6A<br>—<br>~~PP~~|RU42<br>—<br>—<br>~~PP Pp~~|RU2<br>—<br>—<br>~~Pp~~|RU4<br>1/10HP<br>—<br>~~Pp~~|RU42<br>—<br>—<br>~~Pp~~|
|250V AC<br>30V DC<br>~~ef~~<br>~~—~~||||||||||
## **Contact Ratings**
|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|Maximum Contact Capacity<br>Contact<br>Continuous<br>Current<br>Allowable Contact Power<br>Voltage<br>(V)<br>Rated Load<br>Resistive Load<br>Inductive Load<br>Res. Load<br>Ind. Load|
|---|---|---|---|---|---|---|
|||Resistive Load|Inductive Load||Res. Load|Ind. Load|
|DPDT<br>4PDT<br>4PDT<br>bifurcated|10A<br>6A<br>3A|2500VA AC<br>300W DC<br>1500VA AC<br>180W DC<br>750VA AC<br>90W DC|1250VA AC<br>150W DC<br>600VA AC<br>90W DC<br>200VA AC<br>45W DC|250 AC<br>30 DC<br>250 AC<br>30 DC<br>250 AC<br>30 DC|10A<br>10A<br>6A<br>6A<br>3A<br>3A|5A<br>5A<br>0.8A<br>1.5A<br>0.8A<br>1.5A|
## **TÜV Ratings**
## **CSA Ratings**
|Voltage<br>Resistive<br>RU42<br>250V AC<br>3A<br>30V DC<br>3A<br>Voltage<br>Resistive<br>RU2<br>RU4<br>RU42<br>250V AC<br>10A<br>6A<br>3A<br>30V DC<br>10A<br>6A<br>3A<br>~~——~~|Inductive<br>RU2<br>RU4<br>RU42<br>5A<br>0.8A<br>0.8A<br>5A<br>1.5A<br>1.5A|
|---|---|
1. On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A).
2. Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
1705151135
**800-262-IDEC** (4332) • USA & Canada
893
**RU**
## **Relays & Sockets**
## **Socket Specifications**
**==> picture [533 x 675] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sockets Terminal Electrical Rating Wire Size Torque<br>SU2S-11L Spring clamp terminals 250V/10A 24-16 AWG —<br>SU4S-11L Spring clamp terminals 250V/6A (using RU4), 10A (using RU2) 24-16 AWG —<br>DIN Rail Mount SM2S-05 M3 screw with captive wire clamp 300V, 10A Maximum up to 2–#14AWG 5.5 - 9in•lbs<br>Sockets SM2S-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum up to 2–#14AWG 5.5 - 9in•lbs<br>SY4S-05 M3 screw with captive wire clamp 300V, 7A (using RU4), 10A (using RU2) Maximum up to 2–#14AWG 5.5 - 9in•lbs<br>SY4S-05C M3 screw with captive wire clamp, fingersafe 300V, 7A (using RU4), 10A (using RU2) Maximum up to 2–#14AWG 5.5 - 9in•lbs<br>Through Panel SY4S-51 Solder 300V, 7A — —<br>Mount Socket<br>SY4S-61 PCB mount 300V, 7A — —<br>PCB Mount Socket<br>SY4S-62 PCB mount 250V, 7A — —<br>Electrical Life Curves<br>RU2 (Resistive Load) RU4 (Resistive Load) RU42 (Resistive Load)<br>250V AC 250V AC 250V AC<br>30V DC 30V DC 30V DC<br>1000 110V DC 1000 110V DC 110V DC<br>a SS a SN } IN TIT SNP TTT<br>0 3 a a Se TNT NIT<br>100 TTT|) SCT 100 H-NETPIT ECP 100 rTa8 PAEaSTI FT<br>Seeee esti ieee eae ee St Senet i sevilla Neel EH NASH<br>a a A TN<br>10 cr ENT 10 CAa ATE 10 TTIpI ETT IN<br>EEE EeNA eee ree eee Cel rene SS VUee eeeNTT<br>a cas SS een tH<br>a EE nt a<br>1 1 1<br>0.1 0.5 1 5 10 0.1 0.5 1 3 6 0.02 0.1 0.5 1 3 6<br>Load Current (A) Load Current (A) Load Current (A)<br>RU2 (Inductive Load) RU4 (Inductive Load) RU42 (Inductive Load)<br>250V AC/30V DC 250V AC 250V AC<br>110V DC 30V DC 30V DC<br>110V DC 110V DC<br>1000 BSE Se eeete XT TTINGT ST OT Ty AT TT TNT ST TT Ty tT<br>ERE NC Se SE<br>GS‘ N\ NOTTS TT TTT PNT TTI SET<br>100 COENENN IN TTT 100 ——EP NUIING SUI | UT 100 ———PT [NUMING] TE TUT<br>a NS NS<br>ea SST INN aT oN NTC<br>Lt TT Pst NCE N NUM<br>10 ae=——PTT AC: cos ø = 0.3 ee eeNTT\Eee:a ee \\TNTee 10 Pt — aa————A PAssA — NA—NlOO 0 | 10 FePIPV—_————a 8 ——ONSUNS.A CTT<br>—_ DC: L/R = 7 ms |Eee te AC: cos ø = 0.3 ElOe rr AC: cos ø = 0.3 0Cert<br>DC: L/R = 7 ms DC: L/R = 7 ms<br>1 1 1<br>0.1 0.5 1 5 10 0.02 0.1 0.5 0.02 0.1 0.5<br>Load Current (A) Load Current (A) Load Current (A)<br>Maximum Switching Current<br>RU2 RU4 RU42 (Bifurcated)<br>AC resistive AC resistive AC resistive<br>AC inductive AC inductive AC inductive<br>10 (cos ø = 0.3) (cos 9 = 0.3) (cos 9 = 0.3)<br>5<br>Ys 0 | EEC AES 5 ee<br>PAN | A aTs TTT<br>1 ogPeee ee DC resistive ee N W| eeTTTT| <egcS YNeSESSNYX SEa at 2,z< UULUNEBS|ANANIMA) NNUINAEAATNT TT<br>eT A 8B Feep OC resistive SHA FEHTHH & Feb 0Cresistive THANE<br>0.1 ———=naman DC inductiveL/R = 7 ms aMil gS8 0.1 E=EFALRoc DC inductive=seeLUCSeetS ae Seat is}E O41 CollessseeeES EEEURDC inductive= 7 ms _ =eLLRES UlEEE<br>Eeeicee Seea Oe SEAS| He PR| SSS<br>a a [Ee ee<br>a a | a<br>PCE ETT Ee PLUME CCT TT TE<br>10 30 100 250 500 10. 30 100 250 500 10 30 100 250500<br>Load Voltage (V) Load Voltage (V) Load Voltaae (V)<br>Switches & Pilot Lights<br>Signaling Lights<br>Relays & Sockets<br>(¥ 10,000 operations)<br>(¥ 10,000 operations) (¥ 10,000 operations)<br>Timers<br>Contactors (¥ 10,000 operations) (¥ 10,000 operations) (¥ 10,000 operations)<br>Terminal Blocks<br>Load Current (A)<br>Circuit Breakers<br>**----- End of picture text -----**<br>
1705151135
**www.IDEC.com**
894
**Relays & Sockets**
**RU**
## **Ambient Temperature vs. Temperature Rise Curves**
**==> picture [64 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2 (AC Coil, 50 Hz)<br>**----- End of picture text -----**<br>
**==> picture [65 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2 (AC Coil, 60 Hz)<br>**----- End of picture text -----**<br>
**==> picture [44 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2 (DC Coil)<br>**----- End of picture text -----**<br>
**==> picture [512 x 322] intentionally omitted <==**
**----- Start of picture text -----**<br>
12011010090 SrSya 12011010090 aSESy 12011010090 aSESy<br>Load current<br>80 10A ¥ 2 poles 80 80<br>70 lS 70 Ta Load current 10A ¥ 2 poles 70 Ta Load current 10A ¥ 2 poles<br>60 yy RE 60 oe 60 oe<br>eS Sy 4 PST Pty TSE<br>50 SSS RS 50 eS 50 a<br>40 Load current 40 40<br>30 7 5A ¥ 2 poles TS7 S 30 >See Load current 30 [S Load current SEe +<br>20 ee No load current Fs 20 = 5A ¥ 2 poles 20 a 5A ¥ 2 poles e No load current at<br>No load current<br>10 a a 10 ee i n k 10 TT 2 |<br>0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70<br>Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)<br>RU4/RU42 (AC Coil, 50 Hz) RU4/RU42 (AC Coil, 60 Hz) RU4/RU42 (DC Coil)<br>1201101009080 aSrSya 1201101009080 aSrsyTa 1201101009080 aSrSya<br>Load current<br>70 6A ¥ 2 poles 70 Load current 70 Load current<br>60 fp RE 60 t 6A ¥ 2 poles s 60 t 6A ¥ 2 poles s<br>50 SySSeSSN 50 ppp— taTS 50 ppRoy ytPS<br>40 Load current 40 ST 40 SSS<br>30 JT 3A ¥ 4 poles [SSS,] 30 Load current 30 Load current RS<br>20 eeP No load current T s 20 = 3A ¥ 4 poles 20 Ct 3A ¥ 4 poles No load current eres<br>No load current<br>10 aa 10 eea T s 10 TTa 2 = _<br>0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70<br>Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)<br>Temperature Rise (C) Temperature Rise (C) Temperature Rise (C)<br>Temperature Rise (C) Temperature Rise (C) Temperature Rise (C)<br>**----- End of picture text -----**<br>
The above temperature rise curves show the characteristics when 100% the rated coil voltage is applied. The heat resistance of the coil is 120°C. The slant dashed line indicates the allowable temperature rise for the coil at different ambient temperatures. Load current 6A x 2 poles is for the RU4 models only.
1705151135
**800-262-IDEC** (4332) • USA & Canada
895
**Relays & Sockets**
**RU**
## **Internal Connection (View from Bottom)**
**==> picture [126 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2S-* Standard<br>(1)12 (4)42<br>(5)14 (8)44<br>(9)11 (12)41<br>(13)A1 (14)A2<br>24V AC/DC coil or less<br>(1)12 (4)42<br>(5)14 (8)44<br>(9)11 (12)41<br>(13)A1 (14)A2<br>Over 24V AC/DC coil<br>Switches & Pilot Lights<br>Signaling Lights<br>**----- End of picture text -----**<br>
**RU2S-*R with RC**
## **RU2S-*D With Diode**
**==> picture [36 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2V-NF-*<br>**----- End of picture text -----**<br>
**==> picture [535 x 318] intentionally omitted <==**
**----- Start of picture text -----**<br>
(1)12 (4)42 (1)12 (4)42 (1)12 (4)42 (1)12 (4)42<br>(5)14 (8)44 (5)14 (8)44 (5)14 (8)44 (5)14 (8)44<br>(9)11 (12)41 (9)11 (12)41 (9)11 (12)41 (9)11 (12)41<br>(13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2<br>24V AC/DC coil or less 24V DC coil or less<br>ea —<br>(1)12 (4)42 (1)12 (4)42<br>(5)14 (8)44 (5)14 (8)44<br>(9)11 (12)41 (9)11 (12)41<br>(13)A1 (14)A2 (13)A1 (14)A2<br>- +<br>Over 24V AC/DC coil Over 24V DC coil<br>RU4S-*/RU42S-* Standard RU4S-*R/RU42S-*R With RC RU4S-*D/RU42S-*D With Diode RU4V-NF-*/RU42V-NF-*<br>(1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42<br>(5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44<br>(9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41<br>(13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2<br>’ (1)12 — (2)22 (3)32 (4)42 fT (1)12 EEE (2)22 (3)32 (4)42 PEPY<br>(5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44<br>(9)11 f (10)21 ee (11)31 (12)41 (9)11 PPTs (10)21 (11)31 (12)41<br>(13)A1 (14)A2 (13)A1 (14)A2<br>ae<br>Over 24V AC/DC coil Over 24V DC coil<br>24V AC/DC coil or less 24V DC coil or less<br>Signaling Lights<br>Relays & Sockets<br>Timers<br>**----- End of picture text -----**<br>
## **Dimensions (mm)**
## **RU2S**
**==> picture [18 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU2V<br>**----- End of picture text -----**<br>
**==> picture [367 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking Plate Marking Plate<br>Removal Slot Removal Slot<br>13.2<br>0.5 0.8<br>0.5 2.6 2.6<br>ø1.2 ¥ 2.2 Hole<br>oe eel<br>27.5<br>27.5 po<br>Mounting Hole Layout<br>Marking plate removal slot is provided only on one side. 7.0<br>Insert a flat screwdriver into the slot to remove the marking<br>plate.<br>6.4<br>4.1 12.7<br>_ESe=<br>All dimensions in mm.<br>8-ø1 Holes<br>35.0 35.0<br>0.5<br>4.0<br>6.4<br>4 8 12 14<br>21.0 21.0<br>1 5 9 13<br>13.2<br>**----- End of picture text -----**<br>
—IipEc
1705151135
**www.IDEC.com**
896
**Relays & Sockets**
**RU**
## **Dimensions con’t (mm)**
**==> picture [42 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU4S/RU42S<br>**----- End of picture text -----**<br>
**==> picture [41 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RU4V/RU42V<br>**----- End of picture text -----**<br>
**==> picture [371 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking Plate Marking Plate<br>Removal Slot Removal Slot<br>a . 7 3-4.4<br>0.5<br>0.5 2.6 0.8<br>ell ell 2.6<br>ø1.2 × 2.2 Hole<br>a— Le Bee+<br>27.5 27.5<br>Marking plate removal slot is provided only on one side. Mounting Hole Layout<br>Insert a flat screwdriver into the slot to remove the marking 7.0<br>plate.<br>6.4<br>4.1 12.7<br>_ [Ear]<br>All dimensions in mm.<br>14-ø1 Holes<br>35.0 35.0<br>0.5<br>4.0<br>6.4<br>4 8 12 14<br>3 7 11<br>21.0 2 6 10<br>1 5 9 13 21.0<br>13.2<br>4.4<br>**----- End of picture text -----**<br>
## **Spring Clamp DIN Rail Mount Sockets**
**==> picture [259 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
SU2S-11L<br>31<br>Terminal Arrangement<br>12 9<br>8 5<br>2-ø3.2<br>24.0 Mounting Holes 4 1<br>(Ba pe = a Ref |<br>14 13<br>3238.3 Ring terminals cannot be used. (Top View)<br>80<br>37.5<br>28.8<br>4.4<br>**----- End of picture text -----**<br>
**==> picture [33 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SU4S-11L<br>**----- End of picture text -----**<br>
**==> picture [259 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
31<br>Terminal Arrangement<br>12 11 10 9<br>8 7 6 5<br>2-ø3.2<br>24.0 Mounting Holes 4 3 2 1<br>‘fied a fg |<br>14 13<br>3238.3 Ring terminals cannot be used. (Top View)<br>80<br>37.5<br>28.8<br>4.4<br>**----- End of picture text -----**<br>
## **Standard DIN Rail Mount Sockets**
**SM2S-05**
**==> picture [28 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SY4S-05<br>**----- End of picture text -----**<br>
**==> picture [526 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 6 M3 TerminalScrew 31.518 DIN Rail(BNDN) Terminal Arrangement 30 6 M3 TerminalScrew 31.518 DIN Rail(BNDN) 2-ø4.2 Mounting Holes Terminal Arrangement 8 7 6 5<br>2-ø4.2 Mounting Holes(or M4 Tapped Holes) 48 15 (or M4 Tapped Holes) 4 3 2 1<br>26<br>26<br>4 max. 4.8 min. 1214 139 4 max. 4.8 min. 1214 11 10 139<br>18.5 (Top View) 18.5 5.9 max. (Top View)<br>26 25 5.9 max. 26 25 ø3.2 min.<br>ø3.2 min.<br>0.7 0.7<br>62 45 62 45<br>4.2 4.2<br>3 3<br>**----- End of picture text -----**<br>
1705151135
**800-262-IDEC** (4332) • USA & Canada
897
**Relays & Sockets**
**RU**
## **Dimensions con’t (mm)**
**Finger-safe DIN Rail Mount Sockets SM2S-05C** 30 6 M3 Terminal 3525.525.5.55 DIN Rail(BNDN)(BNDN) Screw
## **SY4S-05C**
**==> picture [555 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 30 35.5<br>6 M3 Terminal 3525.525.5.55 DIN Rail(BNDN)(BNDN) 6 M3 TerminalScrew 25 DIN Rail(BNDN) Terminal Arrangement<br>Screw Terminal Arrangement<br>18 2-ø4.2 Mounting Holes(or M4 Tapped Holes) 8 5 18 2-ø4.2 Mounting Holes(or M4 Tapped Holes) 48 73 62 15<br>4 1<br>26 26<br>S wa * 2 ia 14 13<br>14 13 12 11 10 9<br>Ring terminals 12 9 Ring terminals (Top View)<br>26 18.2 cannot be used. (Top View) 26 18.2 cannot be used.<br>29<br>29<br>PCB Mount Sockets<br>SM2S-61 SM2S-62<br>Terminal Arrangement 13.2 13.8 min. 8.2 min.**<br>Terminal Arrangement<br>1 4<br>5 8 1 4<br>aeb 8 9 9 G 12 i sanarel gee A 5 G 8 l mesa<br>13 14 9 12<br>13 14<br>27 113 (Bottom View) 9-ø2 holes 21.2 3 11 (Bottom View) 9-ø2 holes<br>15 15<br>(Tolerance 0.1)<br>1.5 * 19.2 min. when using (Tolerance 0.1)<br>21.2 hold-down springs 1.5 **13.2 min. when using a hold-down spring for* 17.2 min. when using a hold-down spring.<br>the relay with check button.<br>13.2<br>ø5.5 ø5.5<br>4.2 4.2<br>64 46 64 46<br>1.6 2 1.6 2<br>Signaling Lights<br>4.1<br>31 25.4 10.4 4.1 9 29 0.3 16.8 10.4 9<br>16.8<br>0.3 1.4<br>Relays & Sockets *<br>14.2 min.* 1.4<br>12.2 min.<br>**----- End of picture text -----**<br>
**SY4S-61**
**SY4S-62**
**==> picture [512 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
13.2 13.8 min. 8.2 min.**<br>8.8<br>4.4<br>Terminal Arrangement Terminal Arrangement<br>195 1026 1137 1248 13195 1026 1137 121448<br>13 14<br>27 3 (Bottom View) 21.2 3 11 (Bottom View) 15-ø2 holes<br>11 15-ø2 holes 15<br>15 (Tolerance 0.1)<br>| a 1.5 #8 * 19.2 min. when using re a] (Tolerance 0.1) [BG 1.5 @ * 17.2 min. when using a hold-down spring. ee<br>21.2 hold-down springs * *13.2 min. when using a hold-down spring for<br>the relay with check button<br>13.2<br>8.8<br>4.4<br>Timers<br>10.4 4.1 4.1<br>31 25.4 16.8 9 29 0.3 16.8 10.4 9<br>1.4<br>0.3 14.2 min.*<br>1.4 12.2 min.*<br>Contactors<br>**----- End of picture text -----**<br>
## **Through Panel Mount Socket**
**==> picture [27 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SY4S-51<br>**----- End of picture text -----**<br>
**==> picture [286 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
Panel Thickness:1 to 2 [27 (N–1) + 21.4] +0.50<br>Terminal Arrangement<br>7 aon! 1 2 3 4 Po<br>5 6 7 8<br>9 10 11 12<br>13 14<br>27 3 (Bottom View) N: No. of sockets mounted<br>11<br>18.7<br>a<br>2.4 * 10.4 min. when using hold-down springs<br>21.2<br>ie<br>31 25.4 0.2+25.60<br>0.3<br>5.4 min.*<br>Terminal Blocks<br>**----- End of picture text -----**<br>
**==> picture [54 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
—ipeEc<br>**----- End of picture text -----**<br>
1705151135
**www.IDEC.com**
898
Updated at April 26, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →