RTE-P1AF20
Analogue Timer, RTE Series, Multifunction, 20 Ranges, 0.1 s, 600 h, 2 Changeover Relays
- Manufacturer: IDEC
- Product type: Analogue Timers
- SVHC: No SVHC (25-Jun-2025)
- Time Max: 600h
- Time Min: 0.1s
- Timer Output: 2 Changeover Relays
- Product Range: RTE Series
- Timer Functions: Multifunction
- Current Rating Nom: 10A
- Panel Cutout Width: 45mm
- Supply Voltage Max: 240VAC
- Panel Cutout Height: 45mm
- No. of Timing Ranges: 20Ranges
- Connection / Termination: Plug-In
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 39.38 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RTE** **Timers** ## **RTE Series — Analog Timers** ## **Key features:** - 20 time ranges and 10 timing functions - Time delays up to 600 hours - Space-saving package - High repeat accuracy of ± 0.2% - ON and timing OUT LED indicators - Standard 8- or 11-pin and 11-blade termination - 2 form C delayed output contacts - 10A Contact Rating Cert. No. E9950913332316 (EMC, RTE) UL Listed Cert. No. BL960813332355 (LVD, RTE) File No. E66043 Ps@) us Cé ## **General Specifications** ## **Contact Ratings** ~~-~~ Operation System | Solid state CMOS Circuit 2 Form C, DPDT Contact Configuration Operation Type | Multi-Mode (Delay output) Time Range | 0.1sec to 600 hours Allowable Voltage / 240V AC, 30V DC / 10A Allowable Current Pollution Degree | 2 (IE60664-1) Maximum Permissible Over voltage category | III (IE60664-1) 1800 cycles per hour Operating Frequency | AF20 | 100-240V AC(50/60Hz) Resistive 10A 240V AC, 30V DC Rated Operational Voltage | AD24 | 24V AC(50/60Hz)/24V DC | Rated Inductive 7A 240V AC, 30V DC D12 12V DC | | Load Horse Power AF20 85-264V AC(50/60Hz) 1/6 HP 120V AC, 1/3 HP 240V AC Rating Voltage Tolerance AD24 20.4-26.4V AC(50/60Hz)/21.6-26.4V DC Electrical 500,000 op. minimum (Resistive) | D12 | 10.8-13.2V DC Life Mechanical 50,000,000 op. minimum Input off Voltage Rated Voltage x10% minimum Ambient Operating Temperature ~~|~~ -20 to +65ºC (without freezing) Ambient Storage and Transport Temperature ~~|~~ -30 to +75ºC (without freezing) Relative Humidity ~~|~~ 35 to 85%RH (without condensation) Atmospheric Pressure ~~|~~ 80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport) Reset Time 100msec maximum ~~|~~ Repeat Error | ±0.2%, ±20msec* Voltage Error | ±0.2%, ±20msec* Temperature Error | ±0.5%, ±20msec* Setting Error | ±10% maximum Insulation Resistance 100MΩ minimum (500V DC) Between power and output terminals: 2000V AC, 1 minute Dielectric Strength Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole:1000V AC, 1 minute Vibration Resistance | 10 to 55Hz amplitude 0.5mm[2] hours in each of 3 axes | Operating extremes: 98m/sec[2] (10G) Shock Resistance | Damage limits: 490m/sec[2] (50G) 3 times in each of 3 axes | Degree of Protection | IP40 (enclosure) (IEC60529) | TYPE | RTE-P1, -B1 | RTE-P2, -B2 Power Consumption | AF20 | 120V AC/60Hz | 6.5VA | 6.6VA (Approx.) ~~|~~ 240V AC/60Hz 11.6VA[|] 11.6VA 24V AC 60Hz/DC 3.4VA/1.7W 3.5VA/1.7W D12 1.6W 1.6W Mounting Position | Free Dimensions | RTE-P1, P2 | 40Hx 36W x 77.9D mm RTE-B1, B2 40Hx 36W x 74.9D mm RTE-P1 RTE-P2 RTE-B1, -B2 *For the value of the error against a preset Weight (Approx.) time, whichever the largest, applies. 87g 89g 85g ## HipEc 1705151136 **www.IDEC.com** 944 **RTE** **Timers** ## **Part Numbering Guide** RTE series part numbers are composed of 4 part number codes. When ordering a RTE series part, select one code from each category. Example: **RTE-P1AF20** **RTE — P 1 AF20** ~~| LILIL~~ j Series k Terminal l Function m Input Voltage Style Group ## **Part Numbers: RTE Series** ||Description|Part Number Code|Remarks| |---|---|---|---| |jSeries<br>kTerminal Style<br>lFunction Group<br>mInput Voltage|RTE series<br>Pin<br>Blade<br>ON-delay, interval, cycle OFF, cycle ON<br>ON-delay, cycle OFF, cycle ON, signal ON/<br>OFF delay, OFF-delay, one-shot<br>100 to 240V AC(50/60Hz)<br>24V AC(50/60Hz)/24V DC<br>12V DC|RTE<br>P<br>B<br>1<br>2<br>AF20<br>AD24<br>D12|For internal circuits, see next page.<br>Select one only.<br>Each function group has different timing functions.<br>See page 940.| ## **Part Numbers** |Voltage|Power Triggered|Power Triggered|Start Input Triggered|Start Input Triggered| |---|---|---|---|---| ||8-Pin|Blade|11-Pin|Blade| |12V DC<br>24V AC/DC<br>100-240V AC|RTE-P1D12<br>RTE-P1AD24<br>RTE-P1AF20|RTE-B1D12<br>RTE-B1AD24<br>RTE-B1AF20|RTE-P2D12<br>RTE-P2AD24<br>RTE-P2AF20|RTE-B2D12<br>RTE-B2AD24<br>RTE-B2AF20| ## **Time Range Determined by Time Range Selector and Dial Selector** |~~aa~~|Dial<br>~~aa~~|0 - 1<br>~~aa~~|0 - 3<br>~~aa ae~~|0 - 10<br>~~ae~~|0 - 30<br>~~ae~~|0 - 60<br>~~ae~~| |---|---|---|---|---|---|---| |Range<br>~~aa~~|Second<br>Minute<br>Hour<br>10 Hours<br>~~aa~~|0.1 sec - 1 sec<br>1.2 sec - 1 min<br>1.2 min - 1 hr<br>12 min - 10 hr<br>~~aa~~|0.1 sec - 3 sec<br>3.6 sec - 3 min<br>3.6 min - 3 hr<br>36 min - 30 hr<br>~~aa ae~~|0.2 sec - 10 sec<br>12 sec - 10 min<br>12 min - 10 hr<br>2 hr - 100 hr<br>~~ae~~|0.6 sec - 30 sec<br>36 sec - 30 min<br>36 min - 30 hr<br>6 hr - 300 hr<br>~~ae~~|1.2 sec - 60 sec<br>1.2 min - 60 min<br>1.2 hr - 60 hr<br>12 hr - 600 hr<br>~~ae~~| 1705151136 **800-262-IDEC** (4332) • USA & Canada 945 **RTE** **Timers** ## **Timing Diagrams** ## **RTE-P1, -B1** **==> picture [145 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> RTE-P1 RTE-B1<br>4 5 1 2 3<br>ar 3 n 6 4 _ 5 6<br>2 7 7 8 9<br>1 8 A B<br>(~/+) (~/-) (~/+) (~/-)<br>**----- End of picture text -----**<br> 1. RTE-B1: Do not apply voltage to terminals #2, #5 & #8. 2. IDEC so ~~cke~~ t ~~s a~~ re as follows: RTE-P1: SR2P-06* pin type socket, RTE-B1: SR3B-05* blade type socket, (*-may be followed by suffix letter A,B,C or U). ## A: ON-Delay 1 (power start) ## B: Interval (power start) Set timer for desired delay, apply power to coil. Contacts transfer after preset time has elapsed, and Set timer for desired delay, apply power to coil. Contacts transfer immediately, and return to original remain in transferred position until timer is reset. Reset occurs with removal of power. position after preset time has elapsed. Reset occurs with removal of power. **Item Terminal Number Operation Item Terminal Number Operation** Power (1) 2 - 7(2) A - B Power (1) 2 - 7(2) A - B ~~_~~ Delayed (1) 1 - 4, 5 - 8(2) 1 - 7, 3 - 9 (NC) ~~Si7V=z |~~ Delayed (1) 1 - 4, 5 - 8(2) 1 - 7, 3 - 9 (NC) ~~|oa~~ Contact (1) 1 - 3, 6 - 8(2) 4 - 7, 6 - 9 (NO) Contact (1) 1 - 3, 6 - 8(2) 4 - 7, 6 - 9 (NO) PWR PWR Indicator Indicator OUT OUT ~~=ee ee~~ Set Time **T** Set Time ~~——~~ **T** ~~ee~~ C: Cycle 1 (power start, OFF first) D: Cycle 3 (power start, ON first) |Set Time<br>**T**<br>D: Cycle 3 (power start, ON first)<br>Functions in same manner as Mode C, with the exception that first transfer of contacts occurs as soon<br>~~—— ~~| |---| |as power is applies. The ratio is 1:1. Time On = Time Off| |**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(1) 2 - 7<br>(2) A - B<br>Delayed<br>(1) 1 - 4, 5 - 8<br>(2) 1 - 7, 3 - 9<br>(NC)<br>~~ee~~| |Contact<br>(1) 1 - 3, 6 - 8<br>(2) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>OUT<br>Set Time<br>**T**<br>**T**| Functions in same manner as Mode C, with the exception that first transfer of contacts occurs as soon as power is applies. The ratio is 1:1. Time On = Time Off Set timer for desired delay, apply power to coil. First transfer of contacts occurs after preset delay has elapsed, after the next elapse of preset delay contacts return to original position. The timer now cycles between on and off as long as power is applied (duty ratio 1:1). **Item Terminal Number Operation** Power (1) 2 - 7(2) A - B ~~i~~ Delayed ~~a~~ (1) 1 - 4, 5 - 8(2) 1 - 7, 3 - 9 (NC) Contact (1) 1 - 3, 6 - 8(2) 4 - 7, 6 - 9 (NO) PWR Indicator OUT ~~=~~ Set Time ~~SS~~ **T T** ## WIDEC 1705151136 **www.IDEC.com** 946 **RTE** **Timers** ## **Timing Diagrams con’t** ## **RTE-P2, -B2** **==> picture [140 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> RTE-P2 RTE-B2<br>externalcontrolsignal start externalcontrolsignal start<br>5 6 7 1 2 3<br>4 8 4 5 6<br>3 9<br>7 8 9<br>2 10<br>1 11 A B<br>(~/+) (~/-) (~/+) (~/-)<br>**----- End of picture text -----**<br> ## A: ON-Delay 2 (signal start) When a preset time has elapsed after the start input turned on while power is on, the NO output contact goes on. 1. RTE-P2: Do not apply voltage to terminals #5, #6 & #7. 2. RTE-B2: Do not apply voltage to terminals #2, #5 & #8. 3. IDEC sockets are as follows: RTE-P2: SR3P-05* pin type socket, RTE-B2: SR3B-05* blade type socket, (*-may be followed by suffix letter A,B,C or U). ## B: Cycle 2 (signal start, OFF first) When the start input turns on while power is on, the output oscillates at a preset cycle (duty ratio 1:1), starting while the NO contact off. |**Item**<br>Power<br>Start<br>Delayed<br>Contact<br>Indicator<br>Set Time|**Terminal Number**<br>(A) 2 - 10<br>(B) A - B<br>(A) 5 - 6<br>(B) 2 - 5<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>PWR<br>OUT|||**Operation**<br>**T**||||**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>OUT<br>Set Time<br>**T**<br>**T**<br>**T**<br>**T**<br>**T**<br>**T**<br>**T**<br>**T**<br>**T**<br>**Ta**<br>~~|~~<br>~~ASS SS~~<br>~~ae eeweweeeweres~~<br>~~ee~~<br>~~nenaenaenenaenaeneenaenaenneee~~| |---|---|---|---|---|---|---|---|---| C: Cycle 4 (signal start, ON first) ## D: Signal ON/OFF-Delay When the start input turns on while power is on, the NO contact goes on. The output oscillates at a preset cycle (duty ratio 1:1). When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed while the start input remains on, the output contact goes off. When the start input turns off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the NO contact goes off. |**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br>Indicator<br>PWR<br>~~Se~~<br>~~||~~<br>~~ott fe) mmf | ~~|off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the<br>NO contact goes off.<br>**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br> ~~e~~~~**e**~~<br>~~e ee~~|off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the<br>NO contact goes off.<br>**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br> ~~e~~~~**e**~~<br>~~e ee~~|off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the<br>NO contact goes off.<br>**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br> ~~e~~~~**e**~~<br>~~e ee~~|off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the<br>NO contact goes off.<br>**Item**<br>**Terminal Number**<br>**Operation**<br>Power<br>(A) 2 - 10<br>(B) A - B<br>Start<br>(A) 5 - 6<br>(B) 2 - 5<br>Delayed<br>Contact<br>(A) 1 - 4, 8 - 11<br>(B) 1 - 7, 3 - 9<br>(NC)<br>(A) 1 - 3, 9 - 11<br>(B) 4 - 7, 6 - 9<br>(NO)<br> ~~e~~~~**e**~~<br>~~e ee~~| |---|---|---|---|---|---|---|---|---|---| |OUT||||||PWR|||| |||||||Indicator|||| |Set Time||**T**<br>**T**<br>**T**<br>**T**<br>**T**||**T**<br>**T**<br>**T**<br>**Ta**||OUT|||| |E: Signal OFF-Delay<br>When power is turned on while the start input is on, the NO output contact goes on. When a preset|When power is turned on while the start input is on, the NO output contact goes on. When a preset|When power is turned on while the start input is on, the NO output contact goes on. When a preset|When power is turned on while the start input is on, the NO output contact goes on. When a preset|When power is turned on while the start input is on, the NO output contact goes on. When a preset|When power is turned on while the start input is on, the NO output contact goes on. When a preset|Set Time<br>~~P|~~||**T**<br>**T**<br>**Ta**<br>**T**<br>**T**<br>**Ta**<br>~~eae~~|| ## E: Signal OFF-Delay When power is turned on while the start input is on, the NO output contact goes on. When a preset time has elapsed after the start input turned off, the NO output contact goes off. F: One-Shot (signal start) **Item Terminal Number Operation** When the start input turns on while power is on, the NO output contact goes on. When a preset time ~~gy ee~~ Power (A) 2 - 10(B) A - B has elapsed, the NO output contact goes off. **Item Terminal Number Operation** Start (A) 5 - 6(B) 2 - 5 Power (A) 2 - 10(B) A - B Delayed (A) 1 - 4, 8 - 11(B) 1 - 7, 3 - 9 (NC) Start (A) 5 - 6(B) 2 - 5 ~~SR~~ Contact (A) 1 - 3, 9 - 11(B) 4 - 7, 6 - 9 (NO) ~~Sts Ee~~ Delayed (A) 1 - 4, 8 - 11(B) 1 - 7, 3 - 9 (NC) Indicator PWR Contact (A) 1 - 3, 9 - 11(B) 4 - 7, 6 - 9 (NO) OUT PWR Indicator Set Time **T Ta T Ta** OUT ~~SS SS~~ Set Time ~~ee~~ 1705151136 **800-262-IDEC** (4332) • USA & Canada 947 **RTE** **Timers** ## **Temperature Derating Curves** **==> picture [370 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting B<br>Mounting A<br>10A H eO F<br>POI ' F L 1 I r o | 7A ,<br>7A<br>209| |fooofljoool| } Mounting ADerating Curve50 !' ºC 65ºC —i a _ | 5A Mounting BDerating Curve H'<br>Ambient Temperature 50ºC 65ºC<br>po t Ambient Temperature<br>Allowable Current Allowable Current<br>**----- End of picture text -----**<br> ## ## **Instructions** ## **Installation of Hold-Down Springs DIN Rail Mount Socket** **==> picture [430 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> Installation of Hold-Down Springs Switch Settings<br>DIN Rail Mount Socket<br>Insert the springs into the outer<br>slots with the projections Insert the springs<br>facing inside. into the slots.<br>j l<br>k<br>5D ais J 2 ..<br>P<br>j Operator Mode Selector<br>Socket SR2P-06 Hold-down Spring (sold separately) Socket SR2P-05 Hold-down Spring (sold separately) k Scale Selector<br>SFA-202 (use two springs) SFA-203 (use two springs) l Time Range Selector<br>**----- End of picture text -----**<br> 1. Turn the selectors securely using a flat screwdriver 4mm wide (maximum). Note that incorrect setting may cause malfunction. Do not turn the selectors beyond their limits. 2. Since changing the setting during timer operation may cause malfunction, turn power off before changing. ## **Safety Precautions** Special expertise is required to use Electronic Timers. - All Electronic Timers are manufactured under IDEC’s rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic Timer in applications where heavy damage or personal injury may occur should the Electronic Timer fail. - Install the Electronic Timer according to instructions described in this catalog. - Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. - In these directions, safety precautions are categorized in order of importance under Warning and Caution. ## **Warnings** Warning notices are used to emphasize that improper operation may cause severe personal injury or death. - Turn power off to the Electronic timer before starting installation, removal, wiring, maintenance, and inspection on the Electronic Timer. - Failure to turn power off may cause electrical shocks or fire hazard. - Do not use the Electronic Timer for an **emergency stop circuit** or **interlocking circuit** . If the Electronic Timer should fail, a machine malfunction, breakdown, or accident may occur. ## **Caution** Caution notices are used where inattention might cause personal injury or damage to equipment. - The Electronic Timer is designed for installation in equipment. Do not install the Electronic Timer outside equipment. - Install the Electronic Timer in environments described in the specifications. If the Electronic Timer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. - Use an IEC60127-approved fuse and circuit breaker on the power and output line outside the Electronic Timer. - Do not disassemble, repair, or modify the Electronic Timer. - When disposing of the Electronic Timer, do so as industrial waste. Mipec 1705151136 **www.IDEC.com** 948 **RTE** **Timers** ## **Accessories** ## **DIN Rail Mounting Accessories** ## **DIN Rail/Surface Mount Sockets and Hold-Down Springs** |**DIN Rail/Surface Mount Sockets and Hold-Down Springs**|Switches & Pilot Lights<br>**DIN Rail/Surface Mount Sockets and Hold-Down Springs**|| |---|---|---| |Style<br>11-Pin Screw Terminal<br>(dual tier)<br>11-Pin FingerSafe Socket|Switches & Pilot Lights<br>Signaling Lights<br>DIN Rail Mount Socket<br>Applicable Hold-Down Springs<br>Appearance<br>Use with Timers<br>Part Number<br>Appearance<br>Part Number<br>RTE-P2<br>SR3P-05<br>SFA-203<br>SR3P-05C<br>~~>a~~|~~a~~| |8-Pin Screw Terminal<br>8-Pin Fingersafe Socket<br>11-Blade Screw Terminal<br>DIN Mounting Rail<br>Length 1000mm|Relays & Sockets<br>**Timers**<br>RTE-P1<br>SR2P-06<br>SFA-202<br>SR2P-05C<br>RTE-B1<br>RTE-B2<br>SR3B-05<br>—<br>BNDN1000<br>~~a~~<br>~~:~~<br>~~eo~~<br>~~8 ~~ee<br>at~~a~~|| |||| ||**Panel Mounting Accessories**|| |Contactors<br>**Flush Panel Mount Adapter and Sockets that use an Adapter**<br>Accessory<br>Description<br>Appearance<br>Use with<br>Part No.<br>Panel Mount Adapter<br>Adaptor for flush panel<br>mounting RTE timers<br>All RTE timers<br>RTB-G01<br>~~—~~||| ||Terminal Blocks<br>8-pin screw terminal<br>(Shown: SR6P-M08G Wiring Socket Adapter)<br>RTE-P1<br>SR6P-M08G<br>11-pin screw terminal<br>RTE-P2<br>SR6P-M11G<br>~~<~~|~~<~~| |Sockets for use with<br>Panel Mount Adapter|~~|~~|| ||Circuit Breakers<br>8-pin solder terminal<br>RTE-P1<br>SR6P-S08<br>11-pin solder terminal<br>RTE-P2<br>SR6P-S11|| ## **Flush Panel Mount Adapter and Sockets that use an Adapter** 1705151136 **800-262-IDEC** (4332) • USA & Canada 949 **RTE** **Timers** ~~.~~ ## **Dimensions** **==> picture [202 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> 77.9 13.0<br>36.0 13.7<br>wo =<br>- je.<br>FO} Sl vite<br>RTE-P1 (8 pin) Terminal Style<br>40.0<br>**----- End of picture text -----**<br> **==> picture [71 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> RTE-P2 (11 pin)Terminal Style<br>**----- End of picture text -----**<br> ST: 7.3 a RTE-B1/RTE-B2 (11 blade) Terminal Style ## **Panel Mount Adapter** RTE Timer, 8-Pin and 11-Pin with SR6P-S08 or SR6P-S11 **==> picture [179 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> 98 maximum<br>Panel Thickness 0.8 to 5mm<br>48 11 61.2 Back Wiring Socket<br>pty<br>1.7<br>48 42.5<br>**----- End of picture text -----**<br> RTE Timer, 8-Pin with SR6P-M08G **==> picture [215 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> 8-M3.5 Terminal Screw<br>44.6<br>.<br>3.5 max. 5.6 min.<br>3 4 5 6 ø3.6 min.<br>6.9 max.<br>2 1 8 7<br>7<br>80.5 9.8 x 3<br>44.6 30.4<br>**----- End of picture text -----**<br> ## Panel Thickness 0.8 to 5mm RTE Timer, 11-Pin with SR6P-M11G 11-M3.5 Teminal Screws 45 16.7 3.5 max. 5.8 min. 2 1 11 7 6 ø3.6 min. 5 6.9 max. 4 3 8 9 10 30.5 7 Po ES 92 8.5 x 4 —ipeEc 1705151136 **www.IDEC.com** 950
Updated at April 29, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →