RSP-750-24
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 751.2 W, 24 VDC, 31.3 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:751.2W; Output Voltage - Output 1:24V; Output Current - Output 1:31.3A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RSP-750 Series
- No. of Outputs: 1Outputs
- Output Power Max: 751.2W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 31.3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 199.82 € |
| Current stock | 50+ |
| Lead time | 30 days |
**RSP - 750 series** 750W Power Supply with Single Output ## ■ ## ■ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ## ■ cooled by the built-in fan with fan speed control, working for the temperature up to 70. ℃ Moreover, RSP-750 ## ■ _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** 750W Power Supply with Single Output ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**AUXILIARY POWER**<br>**REMOTE ON-OFF CONTROL**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE (OVP)**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC<br>25A/115VAC 40A/230VAC<br><2.0mA / 240VAC<br>105 ~ 125% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>13.8 ~ 16.8V<br>5.75 ~ 6.75V<br>17 ~ 20.5V<br>27.6 ~ 32.4V<br>31 ~ 36.5V<br>56.6 ~ 66.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>Power on : short between<br>&<br>on CN50 Power off : open between<br>&<br>on CN50<br>_Remote ON-OFF(pin13)_<br>_12V-AUX(pin14)_<br>_Remote ON-OFF(pin13)_<br>_12-AUX(pin14)_<br>The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V<br>12V @ 0.1A ; tolerance :<br>10%<br>±<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>336.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>250*127*41mm (L*W*H)<br>1.64Kg; 6pcs/10.8Kg/1.1CUFT<br>87%<br>82%<br>89%<br>90.5%<br>90.5%<br>92%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>150mVp-p<br>150mVp-p<br>10 ~ 13.5V<br>4.75 ~ 5.5V<br>150mVp-p<br>13.5 ~ 16.5V<br>150mVp-p<br>20 ~ 26.4V<br>150mVp-p<br>24 ~ 30V<br>150mVp-p<br>43 ~ 55V<br>12V<br>5V<br>62.5A<br>100A<br>0 ~ 62.5A<br>0 ~ 100A<br>750W<br>500W<br>15V<br>50A<br>0 ~ 50A<br>750W<br>24V<br>31.3A<br>0 ~ 31.3A<br>751.2W<br>27V<br>27.8A<br>0 ~ 27.8A<br>750.6W<br>48V<br>15.7A<br>0 ~ 15.7A<br>753.6W<br>**RSP-750-12**<br>**RSP-750-5**<br>**RSP-750-15**<br>**RSP-750-24**<br>**RSP-750-27**<br>**RSP-750-48**<br>℃<br>℃<br>℃<br>**POWER FACTOR (Typ.)**<br>0.97/230VAC 0.98/115VAC at full load<br>**SAFETY STANDARDS**<br>UL60950-1, TUV EN60950-1 EAC TP TC 004, CCC GB4943.1<br>approved<br>,<br>,BSMI CNS14336-1<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**PROTECTION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2,<br>,<br>CCC GB17625.1,GB/T9254 BSMI CNS13438<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual.<br>**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**<br>Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line<br>~~EE~~<br>~~_aaaa—_-~~<br>—~~———————~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 —_of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. There is high possibility to trigger the floating over voltage protection when PV voltage istrimmed froma high voltage level to a lower voltage level at light<br>load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value.<br>6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5)<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambienttemperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**AUXILIARY POWER**<br>**REMOTE ON-OFF CONTROL**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE (OVP)**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC<br>25A/115VAC 40A/230VAC<br><2.0mA / 240VAC<br>105 ~ 125% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>13.8 ~ 16.8V<br>5.75 ~ 6.75V<br>17 ~ 20.5V<br>27.6 ~ 32.4V<br>31 ~ 36.5V<br>56.6 ~ 66.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>Power on : short between<br>&<br>on CN50 Power off : open between<br>&<br>on CN50<br>_Remote ON-OFF(pin13)_<br>_12V-AUX(pin14)_<br>_Remote ON-OFF(pin13)_<br>_12-AUX(pin14)_<br>The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V<br>12V @ 0.1A ; tolerance :<br>10%<br>±<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>336.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>250*127*41mm (L*W*H)<br>1.64Kg; 6pcs/10.8Kg/1.1CUFT<br>87%<br>82%<br>89%<br>90.5%<br>90.5%<br>92%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>150mVp-p<br>150mVp-p<br>10 ~ 13.5V<br>4.75 ~ 5.5V<br>150mVp-p<br>13.5 ~ 16.5V<br>150mVp-p<br>20 ~ 26.4V<br>150mVp-p<br>24 ~ 30V<br>150mVp-p<br>43 ~ 55V<br>12V<br>5V<br>62.5A<br>100A<br>0 ~ 62.5A<br>0 ~ 100A<br>750W<br>500W<br>15V<br>50A<br>0 ~ 50A<br>750W<br>24V<br>31.3A<br>0 ~ 31.3A<br>751.2W<br>27V<br>27.8A<br>0 ~ 27.8A<br>750.6W<br>48V<br>15.7A<br>0 ~ 15.7A<br>753.6W<br>**RSP-750-12**<br>**RSP-750-5**<br>**RSP-750-15**<br>**RSP-750-24**<br>**RSP-750-27**<br>**RSP-750-48**<br>℃<br>℃<br>℃<br>**POWER FACTOR (Typ.)**<br>0.97/230VAC 0.98/115VAC at full load<br>**SAFETY STANDARDS**<br>UL60950-1, TUV EN60950-1 EAC TP TC 004, CCC GB4943.1<br>approved<br>,<br>,BSMI CNS14336-1<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**PROTECTION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2,<br>,<br>CCC GB17625.1,GB/T9254 BSMI CNS13438<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual.<br>**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**<br>Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line<br>~~EE~~<br>~~_aaaa—_-~~<br>—~~———————~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 —_of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. There is high possibility to trigger the floating over voltage protection when PV voltage istrimmed froma high voltage level to a lower voltage level at light<br>load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value.<br>6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5)<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambienttemperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).|**RSP-750-5**|**RSP-750-12**|**RSP-750-15**|**RSP-750-24**|**RSP-750-27**|**RSP-750-48**| |---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|5V|12V|15V|24V|27V|48V| ||**RATED CURRENT**|100A|62.5A|50A|31.3A|27.8A|15.7A| ||**CURRENT RANGE**|0 ~ 100A|0 ~ 62.5A|0 ~ 50A|0 ~ 31.3A|0 ~ 27.8A|0 ~ 15.7A| ||**RATED POWER**|500W|750W|750W|751.2W|750.6W|753.6W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p|150mVp-p|150mVp-p|150mVp-p|150mVp-p| ||**VOLTAGE ADJ. RANGE**|4.75 ~ 5.5V|10 ~ 13.5V|13.5 ~ 16.5V|20 ~ 26.4V|24 ~ 30V|43 ~ 55V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**LOAD REGULATION**|±2.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms at full load|||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC 127 ~ 370VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR (Typ.)**|0.97/230VAC 0.98/115VAC at full load|||||| ||**EFFICIENCY (Typ.)**|82%|87%|89%|90.5%|90.5%|92%| ||**AC CURRENT (Typ.)**|5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|25A/115VAC 40A/230VAC|||||| ||**LEAKAGE CURRENT**<br>~~EE~~|<2.0mA / 240VAC<br>~~EE~~|||||| ||**OVERLOAD**<br>~~EE~~|105 ~ 125% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>~~EE~~|||||| ||**OVER VOLTAGE (OVP)**<br>~~EE~~|13.8 ~ 16.8V<br>5.75 ~ 6.75V<br>17 ~ 20.5V<br>27.6 ~ 32.4V<br>31 ~ 36.5V<br>56.6 ~ 66.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~EE~~|||||| ||**OVER TEMPERATURE**<br>~~EE~~|Shut down o/p voltage, recovers automatically after temperature goes down<br>~~EE~~|||||| ||**OUTPUT VOLTAGE PROGRAMMABLE(PV)**|Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.|||||| ||**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**|Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual.|||||| ||**AUXILIARY POWER**|12V @ 0.1A ; tolerance :<br>10%<br>±|||||| ||**REMOTE ON-OFF CONTROL**|Power on : short between<br>&<br>on CN50 Power off : open between<br>&<br>on CN50<br>_Remote ON-OFF(pin13)_<br>_12V-AUX(pin14)_<br>_Remote ON-OFF(pin13)_<br>_12-AUX(pin14)_|||||| ||**DC OK SIGNAL**<br>~~_aaaa—_-~~|The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V<br>~~_aaaa—_-~~|||||| ||**WORKING TEMP.**<br>~~_aaaa—_-~~|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>~~_aaaa—_-~~|||||| ||**WORKING HUMIDITY**<br>~~_aaaa—_-~~|20 ~ 90% RH non-condensing<br>~~_aaaa—_-~~|||||| ||**STORAGE TEMP., HUMIDITY**<br>~~_aaaa—_-~~|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>~~_aaaa—_-~~|||||| ||**TEMP. COEFFICIENT**<br>~~_aaaa—_-~~|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>~~_aaaa—_-~~|||||| ||**VIBRATION**<br>~~_aaaa—_-~~|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>~~_aaaa—_-~~|||||| ||**SAFETY STANDARDS**<br>~~_aaaa—_-~~|UL60950-1, TUV EN60950-1 EAC TP TC 004, CCC GB4943.1<br>approved<br>,<br>,BSMI CNS14336-1<br>~~_aaaa—_-~~|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~———————~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||Conducted||EN55032 (CISPR32) / EN55011 (CISPR11)||Class B|| |||Radiated||EN55032 (CISPR32) / EN55011 (CISPR11)||Class B|| |||Harmonic Current||EN61000-3-2||-----|| |||Voltage Flicker||EN61000-3-3||-----|| |||EN55024 , EN61204-3, EN61000-6-2,<br>,<br>CCC GB17625.1,GB/T9254 BSMI CNS13438|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||ESD||EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated||EN61000-4-3||Level 3|| |||EFT / Burst||EN61000-4-4||Level 3|| |||Surge||EN61000-4-5||Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line|| |||Conducted||EN61000-4-6||Level 3|| |||Magnetic Field||EN61000-4-8||Level 4|| |||Voltage Dips and Interruptions<br>~~———————~~||EN61000-4-11<br>~~———————~~||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| ||**MTBF**<br>~~———————~~|336.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~———————~~|||||| ||**DIMENSION**<br>~~———————~~|250*127*41mm (L*W*H)<br>~~———————~~|||||| ||**PACKING**<br>~~———————~~|1.64Kg; 6pcs/10.8Kg/1.1CUFT<br>~~———————~~|||||| ||℃<br>℃<br>℃<br>~~———————~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 —_of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. There is high possibility to trigger the floating over voltage protection when PV voltage istrimmed froma high voltage level to a lower voltage level at light<br>load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value.<br>6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5)<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>8. The ambienttemperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).||||||| > ℃ /1000m with fanless models and of 5 ℃ = /1000m with fan models for operating altitude higher _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** ## 750W Single Output Power Supply ## **Block Diagram** **==> picture [460 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 90KHz<br>PWM fosc : 70KHz<br>+S<br>I/P FILTEREMI CURRENTINRUSHACTIVE RECTIFIERS& SWITCHINGPOWER RECTIFIERS& +V-V<br>LIMITING PFC FILTER<br>-S<br>O.L.P.<br>PFC PWM DETECTION DC OK<br>CONTROL CONTROL CIRCUIT PV/PC<br>O.V.P.<br>RECTIFIERS<br>CONTROL REMOTE ON-OFF<br>ON/OFF<br>AUX FAN RECTIFIERS AUX POWER(12V/0.1A)<br>POWER &<br>FILTER AUX GND<br>**----- End of picture text -----**<br> ## **Static Characteristics** **==> picture [198 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 95 100 115 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> |**MODEL**<br>**INPUT**|**5V**|**12V**|**15V**| |---|---|---|---| |100~264VAC|500W<br>100A|750W<br>62.5A|750W<br>50A| |90VAC|450W<br>90A|675W<br>56.25A|675W<br>45A| |**MODEL**<br>**INPUT**|**24V**|**27V**|**48V**| |100~264VAC|751.2W<br>31.3A|750.6W<br>27.8A|753.6W<br>15.7A| |90VAC|676.08W<br>28.17A|675.54W<br>25.02A|678.24W<br>14.13A| ## **Derating Curve** **==> picture [237 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>50<br>40<br>20<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [8 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> EFFICIENCY (%)<br>**----- End of picture text -----**<br> ## **Efficiency vs Load (48V Model)** **==> picture [243 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> 95<br>90<br>85<br>230V<br>80<br>75<br>70<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>**----- End of picture text -----**<br> ※ The curve above is measured at 230VAC. _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** ## 750W Single Output Power Supply ## **Function Manual** ## **1.Remote Sense** **==> picture [484 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> The remote sensing compensates voltage drop on the load wiring up to 0.5V.<br>1 3 5 7 CN50 13<br>+S -S PV PC DC_OK GND REMOTE<br>TB1 ON-OFF<br>CN50<br>+VS -VS PS PO GND G-AUX 12V-AUX<br>1 13<br>2 4 6 8 14<br>-V +V 2 14<br>LOAD<br>PIN3 -S - + PIN1 +S Fig 1.1<br>**----- End of picture text -----**<br> - The _+S_ signal should be connected to the positive terminal of the load whereas _-S_ signal to the negative terminal. - ◎ By factory default, on CN50 _, Remote ON-OFF_ (pin13) and _12V-AUX_ (pin14), _PV_ (pin5) and _PS_ (pin6), and _PC_ (pin7) and _PO_ (pin8, respectively, are shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated. ## **2.Remote ON-OFF** - ※ The power supply can be turned ON/OFF by using the “Remote ON-OFF” function. **==> picture [476 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> CN50<br>1 3 5 7 13<br>CN50 TB1 +S -S PV PC DC_OK GND REMOTEON-OFF SW<br>1 13<br>+VS -VS PS PO GND G-AUX 12V-AUX<br>2 4 6 8 14<br>-V +V 2 14<br>LOAD<br>- +<br>Fig 2.1<br>Between Remote ON-OFF(pin13) and 12V-AUX(pin14) Power Supply Status<br>SW close (Short) ON<br>SW open (Open) OFF<br>**----- End of picture text -----**<br> - When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power supply should be connected. _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** 750W Single Output Power Supply **3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying EXTERNAL VOLTAGE. **==> picture [428 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> Nominal Vout Vout 120%(Typ.)<br>120<br>110 External Voltage (2~5.5VDC)<br>100<br>80 Non-Linear<br>1 3 5 7 CN50 11 13<br>60<br>+S -S PV PC DC_OK GND REMOTE<br>40 ON-OFF<br>+VS -VS PS PO GND G-AUX 12V-AUX<br>20 UVP 10%(Typ.)<br>2 4 8 14<br>1 2 3 4 5 5.5 6<br>EXTERNAL VOLTAGE (VDC)<br>◎ If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may Fig 3.1<br>enter under voltage protection; it needs to be restarted to work.<br>OUTPUT VOLTAGE (%)<br>**----- End of picture text -----**<br> - ※ Caution: By factory default, the Output Voltage Programming is not activated, and _PV (pin5)_ and _PS(pin6)_ are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections’ diagrams, please keep _PV (pin5)_ and _PS(pin6)_ shorted ; other wise, the power supply will have no output. ## **4. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)** ※ The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [398 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Current Io 115%(Typ.)<br>120<br>110 External Voltage (2~5.5VDC)<br>100<br>80 Non-Linear 1 3 5 7 CN50 11 13<br>+S -S PV PC DC_OK GND REMOTE<br>60 ON-OFF<br>+VS -VS PS PO GND G-AUX 12V-AUX<br>40<br>2 4 6 14<br>20<br>1 2 3 4 5 5.5 6<br>EXTERNAL VOLTAGE (VDC) Fig 4.1<br>CONSTANT CURRENT LEVEL (%)<br>**----- End of picture text -----**<br> - ※ Caution: By factory default, the Output Current Programming is not activated, and _PC(pin7)_ and _PO(pin8)_ are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections’ diagrams, please keep _PC(pin7)_ and _PO(pin8)_ shorted ; otherwise, the power supply will have no output. **==> picture [232 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> TB1<br>CN50<br>1 13<br>-V +V 2 14<br>LOAD<br>- +<br>**----- End of picture text -----**<br> _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** 750W Single Output Power Supply ## **5.DC_OK signal** - ※ "DC_OK" is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. - **Sinking current from external TTL signal:** The maximum sink current is 10mA and the maximum external voltage is 5.6V. **==> picture [480 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Sending out TTL voltage signal :<br>Between DC- OK(pin9) and GND(pin10&11) Output Status<br>0 ~ 1V Power supply ON<br>3.3 ~ 5.6V Power supply OFF<br>CN50<br>1 3 5 7 9 11 13<br>REMOTE<br>+S -S PV PC DC_OK GND<br>ON-OFF<br>TB1<br>CN50 +VS -VS PS PO GND G-AUX 12V-AUX<br>1 13<br>2 4 6 8 14<br>-V +V 2 14<br>LOAD<br>- + Fig 5.1<br>**----- End of picture text -----**<br> _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** ## 750W Single Output Power Supply **==> picture [512 x 667] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No.212A Unit:mm<br>236<br>6<br>1<br>3-M4 L=6<br>1<br>1<br>250<br>231.5<br>41 33.5<br>2-M5<br>-V<br>+V 2<br>2 1 Air flow<br>SVR51 CN50 14 13 direction<br>3 2<br>2<br>1<br>3-M4 L=4<br>TB1 2<br>1<br>3-M4 L=6 1<br>1<br>6<br>236<br>Chassis of RSP-750<br>※ Mounting Instruction Mounting Surface<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque<br>1 M4 6mm 7~11Kgf-cm<br>2 M4 4mm 7~11Kgf-cm<br>Mounting Screw<br>※Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent L<br>1 13<br>Mating Housing HRS DF11-14DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>2 14<br>Pin No. Function Description<br>1 +S Positive sensing for remote sense.<br>2 +VS +V Signal. The +VS should be connected to the +S to reduce the noise when "output voltage programming" function is in use.<br>3 -S Negative sensing for remote sense.<br>4 -VS -V Signal. The -VS should be connected to the -S to reduce the noise when "output voltage programming" function is in use.<br>5 PV Connect to external DC voltage source for output voltage programming, referenced to pin 10,11 (GND).<br>6 PS Reference pin regarding output voltage programming. Please refer to the Function Manual.<br>7 PC Connect to external DC voltage source for output current programming.<br>8 PO Reference pin regarding output current programming. Please refer to the Function Manual.<br>Open collector signal, referenced to pin10,11(GND). Low when PSU turns on.<br>9 DC_OK<br>The maximum sink current is 10mA and the maximum external voltage is 5.6V.<br>10,11 GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output.<br>Auxiliary voltage output ground.<br>12 G-AUX<br>The signal return is isolated from the output terminals (+V & -V).<br>REMOTE Turns the output on and off by electrical or dry contact between pin 13 ( ON/OFF) and pin 14 (12V-AUX).<br>13<br>ON-OFF Short: Power ON, Open: Power OFF.<br>Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AUX).<br>14 12V-AUX<br>The maximum load current is 0.1A. This output is not controlled by the "remote ON/OFF control".<br>127 90<br>25.4<br>7.8<br>7.8<br>20.5<br>25.4<br>18.5<br>63.5<br>10<br>20.5<br>7<br>**----- End of picture text -----**<br> _File Name:RSP-750-SPEC 2018-12-10_ **RSP - 750 series** 750W Single Output Power Supply **==> picture [288 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> ※AC Input Terminal Pin No. Assignment<br>Pin No. Assignment Diagram Maximum mounting torque<br>1 AC/N<br>2 AC/L 18Kgf-cm<br>3 FG<br>※DC Output Terminal Pin No. Assignment<br>Assignment Diagram Maximum mounting torque<br>+V, -V 10Kgf-cm<br>Installation Manual<br>Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:RSP-750-SPEC 2018-12-10_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →