RSP-1600-36
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 1.602 kW, 36 VDC, 44.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:1.602kW; Output Voltage - Output 1:36V; Output Current - Output 1:44.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RSP-1600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 1.602kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 44.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 331.53 € |
| Current stock | 10+ |
| Lead time | 30 days |
> 1600W Power Supply with Single Output **RSP - 1600 series** **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g www.ID 2000000000tuv.com Parallel &® Vv Wks ~~L~~ A ~~]~~ EAL CB C E ■ Certificates * Safety: UL/EN/IEC 60950-1 * EMC: EN 55032 / 55024 ■ ## ■ ## ■ _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** 1600W Power Supply with Single Output ## **SPECIFICATION** |**RSP-1600-12**<br>**RSP-1600-24**<br>**RSP-1600-27**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.5**<br>12V<br>24V<br>27V<br>125A<br>67A<br>59A<br>0 ~ 125A<br>0 ~ 67A<br>0 ~ 59A<br>1500W<br>1608W<br>1593W<br>150mVp-p<br>11.5 ~ 15V<br>200mVp-p<br>200mVp-p<br>23.5 ~ 30V<br>26.5 ~ 33.5V<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>1500ms, 60ms/230VAC at full load<br>16ms / 230VAC at 75% load 10ms / 230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>89%<br>COLD START 35A/230VAC<br>14A/115VAC 8A/230VAC 15A/115VAC 8.5A/230VAC<br><2mA / 230VAC<br>**RSP-1600-48**<br>**RSP-1600-36**<br>48V<br>36V<br>33.5A<br>44.5A<br>0 ~ 33.5A<br>0 ~ 44.5A<br>1608W<br>1602W<br>300mVp-p<br>250mVp-p<br>47.5 ~ 58.8V<br>35.5 ~ 45V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.4**<br>91.5%<br>92%<br>93%<br>92%<br>**OVER TEMPERATURE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 115% rated output power<br>15.75 ~ 18.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>31.5 ~ 37.5V<br>35.2 ~ 41.9V<br>63 ~ 75V<br>47.2 ~ 56.3V<br>**PROTECTION**<br>**ALARM SIGNAL**<br>**REMOTE SENSE**<br>**REMOTE ON-OFF CONTROL**<br>**AUXILIARY POWER**<br>5V @ 0.3A, 12V @ 0.8A<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL60950-1, TUV EN60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>160.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>300*85*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.1Kg;6pcs/13.6Kg/1.03CUFT<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class A<br>Class A<br>-----<br>**NOTE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Isolated signal output for T-alarm and DC OK<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual<br>By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual<br>Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).<br>Please refer to the Function Manual.<br>EN55024 , EN61204-3, EN61000-6-2, BSMI CNS13438<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 4, 2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>℃<br>℃<br>℃<br>Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 6**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 6**<br>~~———————~~<br>_<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the<br>output load is more than 5%.<br>4. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**RSP-1600-12**<br>**RSP-1600-24**<br>**RSP-1600-27**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.5**<br>12V<br>24V<br>27V<br>125A<br>67A<br>59A<br>0 ~ 125A<br>0 ~ 67A<br>0 ~ 59A<br>1500W<br>1608W<br>1593W<br>150mVp-p<br>11.5 ~ 15V<br>200mVp-p<br>200mVp-p<br>23.5 ~ 30V<br>26.5 ~ 33.5V<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>1500ms, 60ms/230VAC at full load<br>16ms / 230VAC at 75% load 10ms / 230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>89%<br>COLD START 35A/230VAC<br>14A/115VAC 8A/230VAC 15A/115VAC 8.5A/230VAC<br><2mA / 230VAC<br>**RSP-1600-48**<br>**RSP-1600-36**<br>48V<br>36V<br>33.5A<br>44.5A<br>0 ~ 33.5A<br>0 ~ 44.5A<br>1608W<br>1602W<br>300mVp-p<br>250mVp-p<br>47.5 ~ 58.8V<br>35.5 ~ 45V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.4**<br>91.5%<br>92%<br>93%<br>92%<br>**OVER TEMPERATURE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 115% rated output power<br>15.75 ~ 18.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>31.5 ~ 37.5V<br>35.2 ~ 41.9V<br>63 ~ 75V<br>47.2 ~ 56.3V<br>**PROTECTION**<br>**ALARM SIGNAL**<br>**REMOTE SENSE**<br>**REMOTE ON-OFF CONTROL**<br>**AUXILIARY POWER**<br>5V @ 0.3A, 12V @ 0.8A<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL60950-1, TUV EN60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>160.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>300*85*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.1Kg;6pcs/13.6Kg/1.03CUFT<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class A<br>Class A<br>-----<br>**NOTE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Isolated signal output for T-alarm and DC OK<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual<br>By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual<br>Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).<br>Please refer to the Function Manual.<br>EN55024 , EN61204-3, EN61000-6-2, BSMI CNS13438<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 4, 2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>℃<br>℃<br>℃<br>Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 6**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 6**<br>~~———————~~<br>_<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the<br>output load is more than 5%.<br>4. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**RSP-1600-12**|**RSP-1600-24**|**RSP-1600-24**|**RSP-1600-27**|**RSP-1600-36**|**RSP-1600-36**|**RSP-1600-48**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|24V||27V|36V||48V| ||**RATED CURRENT**|125A|67A||59A|44.5A||33.5A| ||**CURRENT RANGE**|0 ~ 125A|0 ~ 67A||0 ~ 59A|0 ~ 44.5A||0 ~ 33.5A| ||**RATED POWER**|1500W|1608W||1593W|1602W||1608W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|200mVp-p||200mVp-p|250mVp-p||300mVp-p| ||**VOLTAGE ADJ. RANGE**|11.5 ~ 15V|23.5 ~ 30V||26.5 ~ 33.5V|35.5 ~ 45V||47.5 ~ 58.8V| ||**VOLTAGE TOLERANCE Note.4**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%||±0.5%|±0.5%||±0.5%| ||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%|±0.5%||±0.5%| ||**SETUP, RISE TIME**|1500ms, 60ms/230VAC at full load||||||| ||**HOLD UP TIME (Typ.)**|16ms / 230VAC at 75% load 10ms / 230VAC at full load||||||| ||**VOLTAGE RANGE**<br>**Note.5**|90 ~ 264VAC 127 ~ 370VDC||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||| ||**POWER FACTOR (Typ.)**|0.97/230VAC at full load||||||| ||**EFFICIENCY (Typ.)**|89%|91.5%||92%|92%||93%| ||**AC CURRENT (Typ.)**<br>**Note.5**|14A/115VAC 8A/230VAC|15A/115VAC 8.5A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|COLD START 35A/230VAC||||||| ||**LEAKAGE CURRENT**<br>~~———————~~|<2mA / 230VAC<br>~~———————~~||||||| ||**OVERLOAD**<br>~~———————~~|105 ~ 115% rated output power<br>Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover<br>~~———————~~||||||| ||**OVER VOLTAGE**<br>~~———————~~|15.75 ~ 18.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>31.5 ~ 37.5V<br>35.2 ~ 41.9V<br>63 ~ 75V<br>47.2 ~ 56.3V<br>~~———————~~||||||| ||**OVER TEMPERATURE**<br>~~———————~~|Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>~~———————~~||||||| ||**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 6**<br>~~———————~~|Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).<br>Please refer to the Function Manual.<br>~~———————~~||||||| ||**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 6**|Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.||||||| ||**AUXILIARY POWER**|5V @ 0.3A, 12V @ 0.8A||||||| ||**REMOTE ON-OFF CONTROL**|By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual||||||| ||**REMOTE SENSE**|Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual||||||| ||**ALARM SIGNAL**|Isolated signal output for T-alarm and DC OK||||||| ||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>non-condensing||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)||||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||||||| ||**SAFETY STANDARDS**|UL60950-1, TUV EN60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**|||**Test Level / Note**|| |||Conducted||EN55032 (CISPR32) / EN55011 (CISPR11)|||Class B|| |||Radiated||EN55032 (CISPR32) / EN55011 (CISPR11)|||Class A|| |||Harmonic Current||EN61000-3-2|||Class A|| |||Voltage Flicker||EN61000-3-3|||-----|| |||EN55024 , EN61204-3, EN61000-6-2, BSMI CNS13438||||||| |||**Parameter**||**Standard**|||**Test Level / Note**|| |||ESD||EN61000-4-2|||Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated||EN61000-4-3|||Level 3|| |||EFT / Burst||EN61000-4-4|||Level 3|| |||Surge||EN61000-4-5|||Level 4, 2KV/Line-Line 4KV/Line-Earth|| |||Conducted||EN61000-4-6|||Level 3|| |||Magnetic Field||EN61000-4-8|||Level 4|| |||Voltage Dips and Interruptions||EN61000-4-11|||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| |||160.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| ||**DIMENSION**|300*85*41mm (L*W*H)||||||| ||**PACKING**<br>2.1Kg;6pcs/13.6Kg/1.03CUFT<br>℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the<br>output load is more than 5%.<br>4. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|||||||| ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** ## 1600W Power Supply with Single Output ## **Block Diagram** **==> picture [496 x 593] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 90KHz<br>PWM fosc : 70KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& ORINGFET -V+V<br>-S<br>O.V.P.<br>ORING FET<br>CONTROL<br>PFC PWM DETECTION PV/PC<br>CONTROL CONTROL CIRCUIT<br>TRANSCEIVERS DA/DB<br>DETECTION T-Alarm<br>CIRCUIT MCU MCU ISOLATIONDATA DC-OK<br>SDA/SCL or<br>O.T.P. ( CANH/CANL<br>AUX FAN RECTIFIERS 12V/0.8A Remote ON-OFF<br>POWER & AUX POWER<br>FILTER 5V/0.3A<br>Static Characteristics<br>MODEL<br>100 INPUT 12V 24V 27V 36V 48V<br>90 1500W 1608W 1593W 1602W 1608W<br>180~264VAC<br>80 125A 67A 59A 44.5A 33.5A<br>70 115VAC 1200W 1286.4W 1274.4W 1281.6W 1286.4W<br>100A 53.6A 47.2A 35.6A 26.8A<br>60<br>1050W 1125.6W 1115.1W 1121.4W 1125.6W<br>50 100VAC<br>87.5A 46.9A 41.3A 31.15A 23.45A<br>40<br>900W 964.8W 955.8W 961.2W 964.8W<br>30 90VAC<br>75A 40.2A 35.4A 26.7A 20.1A<br>90 100 115 180 264<br>INPUT VOLTAGE (VAC) 60Hz<br>Derating Curve Efficiency vs Load (48V Model)<br>9 4<br>9 3<br>100 9 2<br>9 1<br>80 9 0<br>230VAC 8 9<br>60 Input only 8 8<br>50 8 7<br>8 6<br>40<br>8 5<br>8 4<br>20<br>8 3<br>8 2<br>-30 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 8 1<br>AMBIENT TEMPERATURE ( ℃ ) 1 0 % 2 0 % 3 0 % 4 0 % 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %<br>LOAD<br>LOAD (%)<br>EFFICIENCY (%)<br>LOAD (%)<br>(<br>**----- End of picture text -----**<br> **==> picture [141 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ The curve above is measured at 230VAC.<br>**----- End of picture text -----**<br> _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** ## 1600W Power Supply with Single Output ## **Function Manual** ## **1** . **Voltage Drop Compensation** **==> picture [439 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 1.1 Remote Sense<br>※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V<br>+V<br>PIN15 +S<br>LOAD<br>PIN16 -S<br>-V<br>-V CN1 +V<br>Sense lines should be twisted in pairs to minimize noise pick-up.<br>◎ The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.<br>**----- End of picture text -----**<br> **==> picture [461 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 1.2 Local Sense<br>※ The +S,-S have to be connected to the +V(signal), -V(signal), respectively, as the following diagram, in order to get the correct output voltage if<br>Remote Sense is not used.<br>+V<br>PIN13 +V(signal) LOAD<br>PIN15 +S<br>-V<br>PIN14 -V(signal)<br>PIN16 -S<br>-V CN1 +V<br>**----- End of picture text -----**<br> **2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE. **==> picture [482 x 242] intentionally omitted <==** **----- Start of picture text -----**<br> PIN12 PV PIN14 -V(signal)<br>-V CN1 +V<br>EXTERNAL VOLTAGE (DC)<br>Vout<br>100<br>125<br>80<br>100<br>Non-Linear<br>60<br>12V<br>40<br>60<br>20<br>40<br>V<br>Others 40 60 80 100 125<br>V<br>0 0.4 1 4.7 5 OUTPUT VOLTAGE (%)<br>◎ The rated current should change with the Output Voltage Programming accordingly.<br>EXTERNAL VOLTAGE (DC)<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.<br>OUTPUT VOLTAGE(%) OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** 1600W Power Supply with Single Output ## **3. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)** ※ The constant current level can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [440 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> Iout<br>110<br>100<br>Non-Linear<br>PIN11 PC PIN14 -V(signal)<br>-V CN1 +V<br>EXTERNAL VOLTAGE (DC)<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section. 20<br>V<br>0.4 1 4.7 5<br>EXTERNAL VOLTAGE (VDC)<br>OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> ## **4. Remote ON-OFF Control** - ※ The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function. **==> picture [421 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> PIN3 +5V-AUX switch Between Remote ON-OFF and +5V-AUX Power Supply Status<br>Switch Short ON<br>Switch Open OFF<br>PIN4 Remote ON-OFF<br>-V CN1 +V<br>**----- End of picture text -----**<br> ## **5. Alarm Signal Output** - ※ There are 2 alarm signals, DC OK and T-ALARM, in TTL signal form, on CN1. These signals are isolated from output. The maximum sink current is 10mA. **==> picture [293 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> PIN5 DC OK<br>Application<br>Circuit<br>PIN6 T-ALARM<br>-V CN1 +V PIN2 GND-AUX<br>**----- End of picture text -----**<br> _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** ## 1600W Power Supply with Single Output ## **6.Current Sharing with Remote Sense** - RSP-1600 has the built-in active current sharing function and can be connected in parallel, up to 6 units, to provide higher output power as exhibited below : ※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load. ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: - Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be balanced. - ※ Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. - ※ CN500/SW1 Function pin connection |(V : CN500 c<br>Parallel<br>1 unit<br>2 unit<br>3 unit<br>4 unit<br>5 unit<br>6 unit<br>RSP-1600<br>+V<br>PSU1|PSU1|PSU2|PSU2|PSU2|PSU2|PSU2|PSU3||PSU4|PSU4|PSU4||PSU5|PSU|SW1<br>6<br>∣<br>∣<br>∣<br>∣<br>∣<br>ON<br>0<br>3<br>TB1<br>5| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||CN500<br>SW1|CN500||CN<br>SW1|||500<br>S|CN50<br>W1|0<br>SW1|||CN50|0<br>SW1|CN500|| ||X<br>ON|∣||∣<br>|||∣<br>∣|∣|∣|||∣|∣|∣|| ||ON<br>V|V||ON|||∣<br>∣|∣|∣|||∣|∣|∣|| ||ON<br>V|V||OFF|||V<br>O|∣<br>N|∣|||∣|∣|∣|| ||ON<br>V|V||OFF|||O<br>V|FF<br>V|ON|||∣|∣|∣|| ||ON<br>V|V||OFF|||O<br>V|FF<br>V|OFF|||V|ON|∣|| ||ON<br>V|V||OFF|||O<br>V|FF<br>V|OFF|||V|OFF|V|| ||onnected ; X : CN5<br>R<br>TB1<br>-V<br>+V|00 not connected.)<br>SP-1600<br>RSP-160<br>TB1<br>-V<br>+V<br>PSU2<br>PSU3|||||0<br>TB1<br>-V|RSP-16<br>+V<br>PSU4|00<br>TB1|-V||RSP-<br>+V<br>PS|DA<br>DB<br><br>DB<br><br>1600<br>RSP-160<br>3<br>CN500<br>P<br>2<br>4<br>6<br>TB1<br>-V<br>+V<br>DA<br>-V(signal)<br>-V(signal)<br>U5<br>PSU6<br>1<br>5||| ||||||||||||||||| ||||||||||||||||| ||||||||||||||||| ||||||||||||||||| ||||||||||||||||| |3<br>1<br>5|||||3<br>1<br>||||6<br>(signal)<br>(signal)<br>5||||||| |||||||||3<br>1|||||||| |||||||||||||DA<br><br><br>PSU5<br>2<br>DA<br>1|||| ||||||||||||||||| |A<br>DB<br>-V(signa||||D|A|DB<br>-V(sig||DB<br>DA<br>-V|||||||DB<br>-V(signal)| |A<br>DB<br>-V(signa||||D|A|DB<br>-V(sig||DA<br>DB<br>-V|||||||DB<br>-V(signal)| ||||||2<br>4<br>||||||||||SU6 CN500<br>4<br>6| ||||||||||<br>||||||| ||||||||||||||||| _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** 1600W Power Supply with Single Output **==> picture [476 x 758] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No.250 Unit:mm<br>30 5.8 252<br>2-M4 L=5<br>20<br>28 1 1<br>-V<br>38<br>+V<br>Air flow<br>LED SW1 SVR (Top View) direction<br>1<br>2 I/P<br>3<br>2 2<br>2-M4 L=5<br>2-M3<br>12 max.<br>5.8 252<br>300<br>1 1<br>(Bottom View)<br>3-M3 L=4<br>1<br>16.1 264.7<br>Chassis of RSP-1600<br>※ Mounting Instruction Mounting Surface<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque<br>1 M3 6mm 6~8Kgf-cm<br>2 M4 7mm 7~1 K0 gf-cm<br>Mounting Screw<br>※ Control Pin No. Assignment(CN1) : HRS DF11-16DP-2DS or equivalent<br>1 15<br>Mating Housing HRS DF11-16DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>2 16<br>Pin No. Function Description<br>1 +12V-AUX Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin2).<br>The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF”.<br>2 GND-AUX Auxiliary voltage output GND.<br>The signal return is isolated from the output terminals (+V & -V).<br>3 +5V-AUX Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin2).<br>The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF<br>4 Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +5V-AUX . (Note.2)<br>ON-OFF Short (4.5 ~ 5.5V) : Power ON ; Open (0 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.<br>High (4.5 ~ 5.5V) : When the Vout ≦80%±5%.<br>5 DC-OK Low (-0.1 ~ 0.5V) : When Vout ≧80%±5%.<br>The maximum sourcing current is 10mA and only for output. (Note.2)<br>High (4.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails.<br>6 T-ALARM Low (-0.1 ~ 0.5V) : When the internal temperature is normal, and when Fan normally works.<br>The maximum sourcing current is 10mA and only for output(Note.2)<br>NC For standard model: Retain for future use.<br>7,8,9<br>A0,A1,A2 For PMBus / CANBus model: PMBus / CANBus interface address lines. (Note.1)<br>10 NC Retain for future use.<br>11 PC Connection for constant current level programming. (Note.1)<br>12 PV Connection for output voltage programming. (Note.1)<br>13 +V (Signal) Positive output voltage signal.<br>It is for local sense; it cannot be connected directly to the load.<br>14 -V (Signal) Negative output voltage signal.<br>It is for local sense and certain function reference; it cannot be connected directly to the load.<br>15 +S Positive sensing for remote sense.<br>16 -S Negative sensing for remote sense.<br>Note.1: Non-isolated signal, referenced to [-V(signal)].<br>Note.2: Isolated signal, referenced to GND-AUX.<br>ψ<br>6.5<br>7.5<br>9<br>21.6 22.8<br>29.6<br>2<br>85<br>10<br>13 41<br>22.8<br>70<br>42.5<br>2 1<br>CN1<br>16 15 1 7<br>2 8<br>CN500<br>**----- End of picture text -----**<br> _File Name:RSP-1600-SPEC 2018-12-10_ **RSP - 1600 series** ## 1600W Power Supply with Single Output **==> picture [80 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> ※ LED Status Indicators<br>**----- End of picture text -----**<br> ||||LED||Description|Description|Description||||| |---|---|---|---|---|---|---|---|---|---|---|---| ||||Green||The power supply functions normally.||||||| ||||Red||Abnormal|status (Over temperature protection, Overload protection, Fan fail.)|||||| ||※||AC Input Terminal Pin No. Assignment||||||||| |||Pin No.||Assignment||||Diagram<br>Maximummounting torque|||| ||||1||FG||||||| ||||2||AC/N|||8Kgf-cm|||| ||||3||AC/L||||||| |※Control Pin No. Assignment(<br>) : HRS DF11-8DP-2DS or equivalent<br>CN500|||||||||||| |||1|7|||||Mating Housing<br>HRS DF11-8DS or equivalent|||| |||||||||Terminal<br>HRS DF11-**SC or equivalent|||| |||2|8||||||||| ||||||||||||| |||**Pin No.**|||**Function**||**Description**||||| ||||1,2||DA||Differential digital signal for parallel control.||||| ||||3,4||DB||Differential digital signal for parallel control.||||| ||||5,6||-V (Signal)||Negative output voltage signal.<br>It is for certain function reference; it cannot be connected directly to the load.||||| ||||||NC||For standard model: None.||||| ||||7||SDA||For PMBus model: Serial Data used in the PMBus interface. (Note)||||| ||||||CANH||For CANBus model: Data line used in CANBus interface. (Note)||||| ||||||NC||For standard model: None.||||| ||||8||SCL||For PMBus model: Serial Clock used in the PMBus interface. (Note)||||| ||||||CANL||For CANBus model: Data line used in CANBus interface. (Note)||||| |Note: Isolated signal, referenced to GND-AUX.|||||||||||| |※Control Pin No. Assignment(SW1)|||||||||||| |||**Pin No.**|||**Function**||**Description**||||| ||||1,2||Terminal<br>resistance||SW1 is the selector of terminal resistor that is designed for DA/DB||signals and parallel control function.||| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:RSP-1600-SPEC 2018-12-10_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →