RSP-1000-15
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 750 W, 15 VDC, 50 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:750W; Output Voltage - Output 1:15V; Output Current - Output 1:50A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outp
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RSP-1000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 750W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 50A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 246.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
1000W Power Supply with Single Output ## **RSP - 1000 series** **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g Parallel &® V ~~&~~ v Wks ~~EEL~~ A www.ID 2000000000 ~~)~~ tuv.com ©N EAL CB C E ■ Certificates **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** 1000W Power Supply with Single Output ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|||||||| |---|---|---|---|---|---|---|---|---| |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**AUXILIARY POWER**<br>**REMOTE ON-OFF CONTROL**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>300ms, 50ms at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>12A/115VAC 6A/230VAC<br>25A/115VAC 40A/230VAC<br><2.0mA / 240VAC<br>105 ~ 125% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>13.8 ~ 16.8V<br>17 ~ 20.5V<br>27.6 ~ 32.4V<br>31 ~ 36.5V<br>56.6 ~ 66.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>-20 ~ +60<br>(Refer to "Derating Curve")<br>℃<br>Power ON : short Power OFF : open. Please refer to the Function Manual.<br>The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V. Please refer to the Function Manual.<br>5V @ 0.5A (+5%, -8%)<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.02%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>313.1K hrs min.<br>Telcordia SR-332 (Bellcore) ; 116.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>295*127*41mm (L*W*H)<br>1.95Kg; 6pcs/12.7Kg/1.15CUFT<br>83%<br>85%<br>88%<br>88%<br>90%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>150mVp-p<br>10 ~ 13.5V<br>150mVp-p<br>13.5 ~ 16.5V<br>150mVp-p<br>20 ~ 26.4V<br>150mVp-p<br>24 ~ 30V<br>150mVp-p<br>43 ~ 55V<br>12V<br>60A<br>0 ~ 60A<br>720W<br>15V<br>50A<br>0 ~ 50A<br>750W<br>24V<br>40A<br>0 ~ 40A<br>960W<br>27V<br>37A<br>0 ~ 37A<br>999W<br>48V<br>21A<br>0 ~ 21A<br>1008W<br>**RSP-1000-12**<br>**RSP-1000-15**<br>**RSP-1000-24**<br>**RSP-1000-27**<br>**RSP-1000-48**<br>℃<br>℃<br>℃<br>**POWER FACTOR (Typ.)**<br>0.95/230VAC 0.98/115VAC at full load<br>**SAFETY STANDARDS**<br>UL60950-1, TUV EN60950-1, EAC TP TC 004, CCC GB4943.1<br>approved<br>,BSMI CNS14336-1<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN55032 (CISPR32) / EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 peniods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>En55024 , EN61204-3, EN61000-6-2,<br>,<br>,<br>CCC GB17625.1 GB/T9254 BSMI CNS13438<br>**CURRENT SHARING**<br>Up to 4000W or (3+1) units. Please refer to the Function Manual.<br>**REMOTE SENSE**<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.<br>Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line<br>po<br>tt<br>~~en~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).||**RSP-1000-12**|**RSP-1000-15**||**RSP-1000-24**|**RSP-1000-27**||**RSP-1000-48**| ||**DC VOLTAGE**|12V|15V||24V|27V||48V| ||**RATED CURRENT**|60A|50A||40A|37A||21A| ||**CURRENT RANGE**|0 ~ 60A|0 ~ 50A||0 ~ 40A|0 ~ 37A||0 ~ 21A| ||**RATED POWER**|720W|750W||960W|999W||1008W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p||150mVp-p|150mVp-p||150mVp-p| ||**VOLTAGE ADJ. RANGE**|10 ~ 13.5V|13.5 ~ 16.5V||20 ~ 26.4V|24 ~ 30V||43 ~ 55V| ||**VOLTAGE TOLERANCE Note.3**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%||±0.5%|±0.5%||±0.5%| ||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%|±0.5%||±0.5%| ||**SETUP, RISE TIME**|300ms, 50ms at full load||||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load||||||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC 127 ~ 370VDC||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||| ||**POWER FACTOR (Typ.)**|0.95/230VAC 0.98/115VAC at full load||||||| ||**EFFICIENCY (Typ.)**|83%|85%||88%|88%||90%| ||**AC CURRENT (Typ.)**|12A/115VAC 6A/230VAC||||||| ||**INRUSH CURRENT (Typ.)**|25A/115VAC 40A/230VAC||||||| ||**LEAKAGE CURRENT**|<2.0mA / 240VAC||||||| ||**OVERLOAD**<br>po|105 ~ 125% rated output power<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>tt||||||| ||**OVER VOLTAGE**<br>po|13.8 ~ 16.8V<br>17 ~ 20.5V<br>27.6 ~ 32.4V<br>31 ~ 36.5V<br>56.6 ~ 66.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>tt||||||| ||**OVER TEMPERATURE**<br>po<br>~~en~~|Shut down o/p voltage, recovers automatically after temperature goes down<br>tt<br>~~en~~||||||| ||**OUTPUT VOLTAGE PROGRAMMABLE(PV)**|Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.||||||| ||**CURRENT SHARING**|Up to 4000W or (3+1) units. Please refer to the Function Manual.||||||| ||**AUXILIARY POWER**|5V @ 0.5A (+5%, -8%)||||||| ||**REMOTE ON-OFF CONTROL**|Power ON : short Power OFF : open. Please refer to the Function Manual.||||||| ||**REMOTE SENSE**|Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.||||||| ||**DC OK SIGNAL**|The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V. Please refer to the Function Manual.||||||| ||**WORKING TEMP.**|-20 ~ +60<br>(Refer to "Derating Curve")<br>℃||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃||||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.02%/<br>(0 ~ 50<br>)||||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||||||| ||**SAFETY STANDARDS**|UL60950-1, TUV EN60950-1, EAC TP TC 004, CCC GB4943.1<br>approved<br>,BSMI CNS14336-1||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**||**Standard**|||**Test Level / Note**|| |||Conducted||EN55032 (CISPR32) / EN55011 (CISPR11)|||Class B|| |||Radiated||EN55032 (CISPR32) / EN55011 (CISPR11)|||Class A|| |||Harmonic Current||EN61000-3-2|||-----|| |||Voltage Flicker||EN61000-3-3|||-----|| |||En55024 , EN61204-3, EN61000-6-2,<br>,<br>,<br>CCC GB17625.1 GB/T9254 BSMI CNS13438||||||| |||**Parameter**||**Standard**|||**Test Level / Note**|| |||ESD||EN61000-4-2|||Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated||EN61000-4-3|||Level 3|| |||EFT / Burst||EN61000-4-4|||Level 3|| |||Surge||EN61000-4-5|||Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line|| |||Conducted||EN61000-4-6|||Level 3|| |||Magnetic Field||EN61000-4-8|||Level 4|| |||Voltage Dips and Interruptions||EN61000-4-11|||>95% dip 0.5 periods, 30% dip 25 peniods,<br>>95% interruptions 250 periods|| |||313.1K hrs min.<br>Telcordia SR-332 (Bellcore) ; 116.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| ||**DIMENSION**|295*127*41mm (L*W*H)||||||| ||**PACKING**<br>1.95Kg; 6pcs/12.7Kg/1.15CUFT<br>℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Wwww.meanwell.com)<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|||||||| ℃ /1000m with fanless models and of 5 ℃ /1000m _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** ## 1000W Power Supply with Single Output ## **Block Diagram** **==> picture [527 x 576] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 110KHz<br>PWM fosc : 90KHz<br>+S<br>I/P FILTEREMI CURRENTINRUSHACTIVE RECTIFIERS& SWITCHINGPOWER RECTIFIERS& +V-V<br>LIMITING PFC FILTER<br>-S<br>CURRENT<br>O.L.P. CURRENT<br>SHARE<br>SHARE<br>PFC PWM DETECTION DC OK<br>CONTROL CONTROL CIRCUIT V_TRIM<br>O.V.P.<br>RECTIFIERS<br>CONTROL REMOTE ON-OFF<br>ON/OFF<br>AUX FAN RECTIFIERS AUX POWER(5V/0.5A)<br>POWER &<br>FILTER AUX GND<br>Static Characteristics<br>100<br>90<br>INPUT MODEL 12V 15V 24V 27V 48V<br>80<br>720W 750W 960W 999W 1008W<br>100~264VAC<br>70 60A 50A 40A 37A 21A<br>60 90VAC 648W 675W 864W 899.1W 907.2W<br>54A 45A 36A 33.3A 18.9A<br>50<br>40<br>90 95 100 115 264<br>INPUT VOLTAGE (VAC) 60Hz<br>Derating Curve Efficiency vs Load (48V Model)<br>95<br>100 90<br>85<br>80<br>80<br>60<br>75<br>40 70<br>65<br>20<br>60<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>LOAD<br>AMBIENT TEMPERATURE ( ℃ )<br>※ The curve above is measured at 230VAC.<br>LOAD (%)<br>EFFICIENCY (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** 1000W Power Supply with Single Output ## **Function Manual** ## **1.Remote Sense** **==> picture [248 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V<br>**----- End of picture text -----**<br> **==> picture [409 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> Sense lines should be twisted in pairs to minimize noise pick-up.<br>1 11 PIN1 +S +V<br>2 12<br>LOAD<br>PIN2 -S PIN10 Vca -V<br>+V -V CN50 TB1 PIN8 Vco<br>PIN6 REMOTE ON-OFF<br>◎ The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.<br>◎ This configuration is based on the assumption the Output Voltage Programming is not activated and power supply is ON.<br>**----- End of picture text -----**<br> **==> picture [19 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Fig 1.1<br>**----- End of picture text -----**<br> ## **2.Remote ON-OFF Control** **==> picture [389 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> ※ The power supply can be turned ON-OFF indivicluaaly or along with other units by using the “Remote ON-OFF” function.<br>Between Remote ON-OFF (pin6) and -S(pin2) Power Supply Status<br>Switch Short ON<br>Switch Open OFF<br>1 11<br>2 12<br>PIN2 -S PIN10 Vca<br>PIN8 Vco<br>+V -V CN50 TB1 Switch<br>PIN6 REMOTE ON-OFF<br>LOAD<br>+ - Fig 2.1<br>**----- End of picture text -----**<br> - The power supply is shipped, by factory default, with _Remote ON-OFF(pin6)_ and _-S(pin2)_ shorted by connector. - ◎ When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V, as well as +S & +V, on each power supply should be connected. ## **3.DC_OK signal** - ※ "DC_OK" is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. **==> picture [397 x 206] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Sinking current from external TTL signal: The maximum sink current is 10mA and the maximum external voltage is 5.6V.<br>◎ Sending out TTL voltage signal :<br>Between DC- OK(pin5) and GND(pin11&12) Output Status<br>0 ~ 1V ON<br>3.3 ~ 5.6V OFF<br>PIN5 DC_OK PIN12 GND<br>1 11<br>2 12<br>PIN2 -S PIN10 Vca<br>PIN8 Vco<br>PIN6 REMOTE ON-OFF<br>+V -V CN50 TB1<br>Fig 3.1<br>**----- End of picture text -----**<br> _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** 1000W Power Supply with Single Output ## **4. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** **==> picture [473 x 685] intentionally omitted <==** **----- Start of picture text -----**<br> ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying<br>either an EXTERNAL VOLTAGE or an EXTERNAL RESISTANCE.<br>(1)Applying EXTERNAL VOLTAGE between " Vci " (pin9) and " -S " (pin2) as shown in Fig4.1<br>1 CN50 11<br>+S AUXG DC_OK CS Vci GND<br>-S AUX ON/OFF Vco Vca GND<br>2 12<br>1 11 PIN1 +S<br>2 12 +V External Voltage<br>LOAD<br>-V<br>PIN2 -S<br>+V -V CN50 TB1 PIN9 Vci<br>EXTERNAL VOLTAGE (DC)<br>PIN6 REMOTE ON-OFF<br>◎ +S & +V and -S & -V also need to be connected on CN50<br>Fig 4.1<br>(2)Applying EXTERANL RESISTANCE as shown in Fig4.2 & Fig 4.3<br>(A) Output voltage goes down<br>CN50 11<br>1<br>+S AUXG DC_OK CS Vci GND<br>REMOTE<br>-S AUX Vco Vca GND<br>PIN3 AUXG ON-OFF<br>1 11 PIN1 +S PIN9 Vci 2 12<br>2 12<br>R1<br>PIN2 -S PIN10 Vca<br>+V -V CN50 TB1 PIN4 AUX +V-V LOAD<br>R1<br>PIN6 REMOTE ON-OFF<br>◎ +S & +V and -S & -V also need to be connected on CN50.<br>Fig 4.2<br>(B)Output voltage goes up<br>CN50 11<br>1<br>+S AUXG DC_OK CS Vci GND<br>REMOTE<br>-S AUX Vco Vca GND<br>ON-OFF<br>PIN3 AUXG 2 12<br>1 11 PIN1 +S PIN9 Vci<br>2 12 R2<br>PIN2 -S PIN10 Vca +V<br>LOAD<br>+V -V CN50 TB1 PIN4 AUX -V<br>R2<br>PIN6 REMOTE ON-OFF<br>◎ +S & +V and -S & -V also need to be connected on CN50.<br>Fig 4.3<br>Vout OVP 120%(Typ.) Vout Vout OVP 120%(Typ.)<br>120<br>100<br>100 90<br>110<br>80 Non-Linear 80 Non-Linear Non-Linear<br>70<br>60 105<br>60<br>40<br>50<br>20 40 100<br>1 2 3 4 5 6 Vci(Referenced to -S) 390 560 820 1K2 2K2 4K7 open R1, 1/8W(Typ.) open 18K 7K5 R2, 1/8W(Typ.)<br>EXTERNAL VOLTAGE (VDC) EXTERNAL RESISTANCE ( Ω ) EXTERNAL RESISTANCE ( Ω )<br>Fig 4.1.1 Fig 4.2.1 Fig 4.3.1<br>OUTPUT VOLTAGE (%) OUTPUT VOLTAGE (%)<br>OUTPUT VOLTAGE (%)<br>**----- End of picture text -----**<br> ※ Caution: By factory default, the Output Voltage Programming is not activated, and _Vco (pin8)_ and _Vca(pin10)_ are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections’ diagrams, please keep _Vco(pin8)_ and _Vca(pin10)_ shorted ; other wise, the power supply will have no output. _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** 1000W Power Supply with Single Output ## **5.Current Sharing with Remote Sense** RSP-1000 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : - ※The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: **==> picture [482 x 322] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9<br>※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit)<br>the current shared among units may not be fully balanced.<br>PSU PSU PSU PSU<br>+V -V CN50 TB1 +V -V CN50 TB1 +V -V CN50 TB1 +V -V CN50 TB1<br>1 11 1 11 1 11 1 11<br>2 12 2 12 2 12 2 12<br>+S(pin1)<br>-S(pin2)<br>CS(pin7)<br>+V -V Sense lines should<br>be twisted in pairs<br>LOAD<br>Fig 5.1<br>1 CN50 11 1 CN50 11 1 CN50 11 1 CN50 11<br>+S AUXG DC_OK CS Vci GND +S AUXG DC_OK CS Vci GND +S AUXG DC_OK CS Vci GND +S AUXG DC_OK CS Vci GND<br>-S AUX ON/OFF Vco Vca GND -S AUX ON/OFF Vco Vca GND -S AUX ON/OFF Vco Vca GND -S AUX ON/OFF Vco Vca GND<br>2 12 2 12 2 12 2 12<br>**----- End of picture text -----**<br> - +S,-S and CS are connected mutually in parallel. _File Name:RSP-1000-SPEC 2018-12-10_ ## 1000W Power Supply with Single Output ## **RSP - 1000 series** **==> picture [488 x 585] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 952B Unit:mm<br>277.7<br>6<br>1<br>3-M4 L=6<br>1<br>1<br>295<br>41 21 34.5<br>2-M5<br>+V<br>-V 2<br>Air flow<br>SVR51 direction<br>2 1<br>CN50 12 11 2<br>3<br>2<br>1<br>3-M4 L=4<br>TB1 2<br>1<br>3-M4 L=6 1<br>1<br>6<br>277.7<br>Chassis of RSP-1000<br>※ Mounting Instruction Mounting Surface<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque<br>1 M4 6mm 7~11Kgf-cm<br>2 M4 4mm 7~11Kgf-cm<br>Mounting Screw<br>※Control Pin No. Assignment (CN50) : HRS DF11-12DP-2DS or equivalent L<br>1 11<br>Mating Housing HRS DF11-12DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>2 12<br>Pin No. Function Description<br>1 +S Positive sensing for remote sense.<br>2 -S Negative sensing for remote sense.<br>Auxiliary voltage output ground.<br>3 G-AUX<br>The signal return is isolated from the output terminals (+V & -V).<br>Auxiliary voltage output, 4.6~5.25V, referenced to pin 3(G-AUX).<br>4 5V-AUX<br>The maximum load current is 0.5A. This output has the built-in oring diodes and is not controlled by the "remote ON/OFF control".<br>Open collector signal, referenced to pin11,12(GND).<br>5 DC_OK<br>Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 5.6V.<br>Remote<br>6 ON-OFF Turns the output on and off by electrical or dry contact between pin 6 (Remote ON-OFF) and pin 2 (-S). Short: Power ON, Open: Power OFF.<br>Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance<br>7 CS<br>between units.<br>8 Vco Short connecting between Vco (pin8) and Vca (pin10) if output voltage programming function is not activated.<br>9 Vci Connect to external DC voltage source for output voltage programming, referenced to pin 2 (-S).<br>10 Vca Connect to external resistor (1/8W) for output voltage programming.<br>11,12 GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output.<br>7.8<br>20.5<br>25.4<br>18.5<br>59<br>127 90<br>10<br>25.4<br>20.5<br>7.8<br>7<br>**----- End of picture text -----**<br> _File Name:RSP-1000-SPEC 2018-12-10_ **RSP - 1000 series** 1000W Power Supply with Single Output **==> picture [288 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> ※AC Input Terminal Pin No. Assignment<br>Pin No. Assignment Diagram Maximum mounting torque<br>1 AC/N<br>2 AC/L 18Kgf-cm<br>3 FG<br>※DC Output Terminal Pin No. Assignment<br>Assignment Diagram Maximum mounting torque<br>+V, -V 10Kgf-cm<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:RSP-1000-SPEC 2018-12-10_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →