Image not available
Illustrative purposes only
RS-150-5
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 150 W, 5 VDC, 26 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RS-150 Series
- No. of Outputs: 1Outputs
- Output Power Max: 150W
- Input Voltage VAC: 88V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 26A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 54.53 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RS - 150 series** ## 150W Single Output Switching Power Supply **User’s Manual** ## ■ - ‧ - ‧ - ‧ - ‧ - ‧℃ - ‧ - ‧℃ - ‧ - ‧ ## ■ **** ‧ |**SPECIFICATION**<br>**AS/NZS62368-1**<br>**IEC62368-1**<br>**UL62368-1**<br>**BS EN/EN62368-1**<br>**TPTC004**|**SPECIFICATION**<br>**AS/NZS62368-1**<br>**IEC62368-1**<br>**UL62368-1**<br>**BS EN/EN62368-1**<br>**TPTC004**|||**AS/NZS62368-1**|**AS/NZS62368-1**<br>**UL62368-1**<br>**BS EN/EN62368-1**|**IEC62368-1**<br>**BS EN/EN62368-1**|**TPTC004**| |---|---|---|---|---|---|---|---| |**ENVIRONMENT**<br>**PROTECTION**<br>**MODEL**<br>**RS-150-3.3**<br>**RS-150-5**<br>**RS-150-12**<br>**RS-150-15**<br>**RS-150-24**<br>**RS-150-48**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.)Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCENote.3**<br>**LINE REGULATIONNote.4**<br>**LOAD REGULATION Note.5**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY(Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOADNote.8**<br>**OVER VOLTAGE**<br>3.3V<br>5V<br>12V<br>15V<br>24V<br>48V<br>30A<br>26A<br>12.5A<br>10A<br>6.5A<br>3.3A<br>0 ~ 30A<br>0 ~ 26A<br>0 ~ 12.5A<br>0 ~ 10A<br>0 ~ 6.5A<br>0 ~ 3.3A<br>99W<br>130W<br>150W<br>150W<br>156W<br>158.4W<br>80mVp-p<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>3.2V ~ 3.5V<br>4.75 ~ 5.5V<br>11.4 ~ 13.2V<br>14.25 ~ 16.5V<br>22.8 ~ 26.4V<br>45.6 ~ 52.8V<br>±3.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load<br>28ms/230VAC 20ms/115VAC at full load<br>88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)<br>47 ~ 63Hz<br>74%<br>3.8 ~ 4.45V<br>5.75 ~ 6.75V<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>55.2 ~ 64.8V<br>78%<br>83%<br>84%<br>86%<br>86%<br>3A/115VAC 2A/230VAC<br>COLD START 40A/230VAC<br><2mA / 240VAC<br>110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>UL62368-1, TUV<br>EN62368-1, AS/NZS 62368.1,<br>approved<br>BS EN/<br>EAC TP TC 004<br>Compliance to<br>EN55032 (CISPR32) Class B,<br>EN61000-3-2,-3,<br>BS EN/<br>BS EN/<br>EAC TP TC 020<br>-25 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>244KHrs min. MIL-HDBK-217F (25℃)<br>199*98*38mm (L*W*H)<br>℃<br><br><br><br><br><br><br> <br><br><br><br><br><br>(as available on http://www.meanwell.com)<br><br><br><br>℃℃<br>※:https://www.meanwell.com/serviceDisclaimer.aspx<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>0.7Kg; 20pcs/14Kg/0.85CUFT<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25℃/ 70% RH<br>**SAFETY &**<br>**EMC**<br>**(Note 6)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>3044.1K hrs min. Telcordia SR-332 (Bellcore) ; 437.3K hrs min. MIL-HDBK-217F (25℃)<br>-————<br>Z<br>Po<br>___| ~~——~~<br>~~———<——~~<br>| pe||**RS-150-3.3**<br>Z|**RS-150-5**|**RS-150-12**|**RS-150-15**<br>**RS-150-24**|**RS-150-24**|**RS-150-48**| ||**DC VOLTAGE**<br>-————|3.3V<br>Z<br>|5V<br>~~——~~<br>pe|12V<br>~~——~~<br>pe|15V<br>24V|24V|48V| ||**RATED CURRENT**<br>-————<br>~~———<——~~|30A<br>Z<br><br>~~———<——~~|26A<br>~~——~~<br>~~———<——~~<br>pe|12.5A<br>~~——~~<br>pe|10A<br>6.5A|6.5A|3.3A| ||**CURRENT RANGE**<br>-————<br>~~———<——~~|0 ~ 30A<br>Z<br>___|<br>~~———<——~~|0 ~ 26A<br>___| ~~——~~<br>~~———<——~~<br> pe|0 ~ 12.5A<br>~~——~~<br>pe|0 ~ 10A<br>0 ~ 6.5A|0 ~ 6.5A|0 ~ 3.3A| ||**RATED POWER**<br>~~———<——~~|99W<br>___|<br>~~———<——~~|130W<br>___| <br>~~———<——~~<br>||150W<br><br>|150W<br>156W|156W|158.4W| ||**RIPPLE & NOISE (max.)Note.2**<br>~~———<——~~|80mVp-p<br>___|<br>~~———<——~~|80mVp-p<br>___| <br>~~———<——~~<br>||120mVp-p<br><br>|120mVp-p<br>120mVp-p|120mVp-p|200mVp-p| ||**VOLTAGE ADJ. RANGE**<br>Po<br>~~———<——~~|3.2V ~ 3.5V<br>~~———<——~~|4.75 ~ 5.5V<br>~~———<——~~|11.4 ~ 13.2V|14.25 ~ 16.5V<br>22.8 ~ 26.4V|22.8 ~ 26.4V|45.6 ~ 52.8V| ||**VOLTAGE TOLERANCENote.3**<br>Po<br>~~———<——~~|±3.0%<br>~~———<——~~|±2.0%<br>~~———<——~~|±1.0%|±1.0%<br>±|±1.0%|±1.0%| ||**LINE REGULATIONNote.4**<br>Po<br>~~———<——~~|±0.5%<br>~~———<——~~|±0.5%<br>~~———<——~~|±0.5%|±0.5%<br>±|±0.5%|±0.5%| ||**LOAD REGULATION Note.5**<br>~~———<——~~|±2.0%<br>~~———<——~~|±1.0%<br>~~———<——~~|±0.5%|±0.5%<br>±|±0.5%|±0.5%| ||**SETUP, RISE TIME**|800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load|||||| ||**HOLD UP TIME (Typ.)**|28ms/230VAC 20ms/115VAC at full load|||||| ||**VOLTAGE RANGE**|88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**EFFICIENCY(Typ.)**|74%|78%|83%|84%<br>86%|86%|86%| ||**AC CURRENT (Typ.)**|3A/115VAC 2A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|COLD START 40A/230VAC|||||| ||**LEAKAGE CURRENT**|<2mA / 240VAC|||||| ||**OVERLOADNote.8**|110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||| ||**OVER VOLTAGE**|3.8 ~ 4.45V<br>5.75 ~ 6.75V<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>55.2 ~ 64.8V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||| ||**WORKING TEMP.**|-25 ~ +70℃(Refer to "Derating Curve")|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH|||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL62368-1, TUV<br>EN62368-1, AS/NZS 62368.1,<br>approved<br>BS EN/<br>EAC TP TC 004|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25℃/ 70% RH|||||| ||**EMC EMISSION**|Compliance to<br>EN55032 (CISPR32) Class B,<br>EN61000-3-2,-3,<br>BS EN/<br>BS EN/<br>EAC TP TC 020|||||| ||**EMC IMMUNITY**|3044.1K hrs min. Telcordia SR-332 (Bellcore) ; 437.3K hrs min. MIL-HDBK-217F (25℃)|||||| ||**MTBF**|244KHrs min. MIL-HDBK-217F (25℃)|||||| ||**DIMENSION**|199*98*38mm (L*W*H)|||||| ||**PACKING**<br>℃<br><br><br><br><br><br><br> <br><br><br><br><br><br>(as available on http://www.meanwell.com)<br><br><br><br>℃℃<br>※:https://www.meanwell.com/serviceDisclaimer.aspx<br>0.7Kg; 20pcs/14Kg/0.85CUFT||||||| ## **SPECIFICATION** **NOTE** ℃ (as available on http://www.meanwell.com) ℃℃ ※:https://www.meanwell.com/serviceDisclaimer.aspx _File Name:RS-150-SPEC 2022-02-28_ **RS - 150 series** ## 150W Single Output Switching Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 902A Unit:mm<br>197<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>4.5 57.5 120<br>199<br>6.5 190<br>Terminal Pin No. Assignment<br>Pin No. Assignment Pin No. Assignment<br>1 AC/L 4,5 DC OUTPUT -V<br>2 AC/N 6,7 DC OUTPUT +V<br>3 FG<br>22 157<br>Block Diagram<br>230<br>115 fosc : 60KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P FILTER & SWITCHING & -V<br>FILTER FILTER<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>Others 90<br>80<br>80<br>60 70<br>3.3V,5V<br>60<br>40<br>50<br>20<br>40<br>-25 0 10 20 30 40 50 60 70 (VERTICAL) 88 95 100 115 120 132<br>-25 0 (HORIZONTAL) 176 190 200 230 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>3-M3<br>ψ3.5 4-M3<br>ψ<br>3.5<br>12 9 7<br>3.5<br>9.5<br>80 85.5 98<br>8.2<br>9 9.5<br>18<br>18 3.5 38<br>28.5<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RS-150-SPEC 2022-02-28_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →