RPS-60-12
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 60 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPS-60 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 60W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 14.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RPS - 60 series** 60W Reliable Green Medical Power Supply ## + + ## ■ ## ■ Suitable for BF application with appropriate system consideration Cooling by free air convection EMI class B for class Ⅰ configuration No load power consumption<0.75W Protections: Short circuit / Overload / Over voltage Operating altitude up to 3000 meters ## **Description** RPS-60 is a 60W highly reliable green PCB type medical power supply with a high power density on the 4” by 2” footprint. It accepts 90~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 86% and the extremely low no load power consumption is down below 0.75W. RPS-60 is able to be used for ClassⅠ (with FG) system design. The extremely low leakage current is less than 130 μ A. In addition, it conforms to international IT and medical regulations (2*MOPP) and EMC EN55022/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.y _File Name:RPS-60-SPEC 2020-10-20_ ## 60W Reliable Green Medical Power Supply ## **RPS - 60 series** ## **SPECIFICATION** |**MODEL**<br>**RPS-60-3.3**<br>**RPS-60-12**<br>**RPS-60-5**<br>**RPS-60-15**<br>**RPS-60-24**<br>**RPS-60-48**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**PEAK LOAD(10sec.)**<br>**Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT(max.) Note.5**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION (L*W*H)**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>3.3V<br>12V<br>5V<br>15V<br>24V<br>48V<br>10A<br>5A<br>10A<br>4A<br>2.5A<br>1.25A<br>0 ~ 11A<br>0 ~ 5.5A<br>0 ~ 11A<br>0 ~ 4.4A<br>0 ~ 2.75A<br>0 ~ 1.375A<br>33W<br>36.3W<br>60W<br>66W<br>50W<br>55W<br>60W<br>66W<br>60W<br>66W<br>60W<br>66W<br>60mVp-p<br>60mVp-p<br>60mVp-p<br>100mVp-p<br>100mVp-p<br>100mVp-p<br>3.1 ~ 3.6V<br>11.4 ~ 13.2V<br>4.75 ~ 5.5V<br>13.5 ~ 16.5V<br>22.8 ~ 27.6V<br>45.6 ~ 52.8V<br>±2.0%<br>±2.0%<br>±2.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±2.0%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±1.0%<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>60ms/230VAC 12ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>3.8 ~ 5V<br>5.7 ~ 6.8V<br>13.8 ~ 16.2V<br>17.2 ~ 20.3V<br>28.4 ~ 32.4V<br>55.2 ~ 64.8V<br>74%<br>84%<br>79%<br>85%<br>87%<br>86%<br>1.8A/115VAC 1 A/230VAC<br>COLD START 60A/230VAC 30A/115VAC<br>115 ~ 150% rated output power<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>353.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>101.6*50.8*29mmor 4" * 2" *1.141" inch<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**PROTECTION**<br>℃<br>6.<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>IEC62368-1, UL62368-1, TUV EN62368-1, IEC60601-1, TUV EN60601-1, UL ANSI / AAMI ES60601-1(3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3,<br>approved; Design refer to EN60335 1<br>-<br>EAC TP TC 004<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>Earth leakage current < 130 A/264VAC , Touch current < 100 A/264VAC<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN60601-1-2<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>**OPERATING ALTITUDE Note.6** 3000 meters<br>μ<br>μ<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conducted emission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 4, 4KV/Line-FG; 2KV/Line-Line<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>~~a=~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Heat Sink HS1,HS2 can not be shorted.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|**MODEL**<br>**RPS-60-3.3**<br>**RPS-60-12**<br>**RPS-60-5**<br>**RPS-60-15**<br>**RPS-60-24**<br>**RPS-60-48**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**PEAK LOAD(10sec.)**<br>**Note.2**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT(max.) Note.5**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION (L*W*H)**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>3.3V<br>12V<br>5V<br>15V<br>24V<br>48V<br>10A<br>5A<br>10A<br>4A<br>2.5A<br>1.25A<br>0 ~ 11A<br>0 ~ 5.5A<br>0 ~ 11A<br>0 ~ 4.4A<br>0 ~ 2.75A<br>0 ~ 1.375A<br>33W<br>36.3W<br>60W<br>66W<br>50W<br>55W<br>60W<br>66W<br>60W<br>66W<br>60W<br>66W<br>60mVp-p<br>60mVp-p<br>60mVp-p<br>100mVp-p<br>100mVp-p<br>100mVp-p<br>3.1 ~ 3.6V<br>11.4 ~ 13.2V<br>4.75 ~ 5.5V<br>13.5 ~ 16.5V<br>22.8 ~ 27.6V<br>45.6 ~ 52.8V<br>±2.0%<br>±2.0%<br>±2.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±2.0%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±1.0%<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>60ms/230VAC 12ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>3.8 ~ 5V<br>5.7 ~ 6.8V<br>13.8 ~ 16.2V<br>17.2 ~ 20.3V<br>28.4 ~ 32.4V<br>55.2 ~ 64.8V<br>74%<br>84%<br>79%<br>85%<br>87%<br>86%<br>1.8A/115VAC 1 A/230VAC<br>COLD START 60A/230VAC 30A/115VAC<br>115 ~ 150% rated output power<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>353.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>101.6*50.8*29mmor 4" * 2" *1.141" inch<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**PROTECTION**<br>℃<br>6.<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>IEC62368-1, UL62368-1, TUV EN62368-1, IEC60601-1, TUV EN60601-1, UL ANSI / AAMI ES60601-1(3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3,<br>approved; Design refer to EN60335 1<br>-<br>EAC TP TC 004<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>Earth leakage current < 130 A/264VAC , Touch current < 100 A/264VAC<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN60601-1-2<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>**OPERATING ALTITUDE Note.6** 3000 meters<br>μ<br>μ<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conducted emission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 4, 4KV/Line-FG; 2KV/Line-Line<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>~~a=~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Heat Sink HS1,HS2 can not be shorted.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|**RPS-60-3.3**|**RPS-60-5**|**RPS-60-12**|**RPS-60-12**|**RPS-60-15**|**RPS-60-24**|**RPS-60-48**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|5V|12V||15V|24V|48V| ||**RATED CURRENT**|10A|10A|5A||4A|2.5A|1.25A| ||**CURRENT RANGE**|0 ~ 11A|0 ~ 11A|0 ~ 5.5A||0 ~ 4.4A|0 ~ 2.75A|0 ~ 1.375A| ||**RATED POWER**|33W|50W|60W||60W|60W|60W| ||**PEAK LOAD(10sec.)**<br>**Note.2**|36.3W|55W|66W||66W|66W|66W| ||**RIPPLE & NOISE (max.) Note.3**|60mVp-p|60mVp-p|60mVp-p||100mVp-p|100mVp-p|100mVp-p| ||**VOLTAGE ADJ. RANGE**|3.1 ~ 3.6V|4.75 ~ 5.5V|11.4 ~ 13.2V||13.5 ~ 16.5V|22.8 ~ 27.6V|45.6 ~ 52.8V| ||**VOLTAGE TOLERANCE Note.4**|±2.0%|±2.0%|±2.0%||±2.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%||±0.5%|±0.5%|±0.5%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%||±1.0%|±1.0%|±1.0%| ||**SETUP, RISE TIME**|500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load||||||| ||**HOLD UP TIME (Typ.)**|60ms/230VAC 12ms/115VAC at full load||||||| ||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||| ||**EFFICIENCY (Typ.)**|74%|79%|84%||85%|87%|86%| ||**AC CURRENT (Typ.)**|1.8A/115VAC 1 A/230VAC||||||| ||**INRUSH CURRENT (Typ.)**|COLD START 60A/230VAC 30A/115VAC||||||| ||**LEAKAGE CURRENT(max.) Note.5**|Earth leakage current < 130 A/264VAC , Touch current < 100 A/264VAC<br>μ<br>μ||||||| ||**OVER LOAD**|115 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||||| ||**OVER VOLTAGE**<br>~~a=~~|3.8 ~ 5V<br>5.7 ~ 6.8V<br>13.8 ~ 16.2V<br>17.2 ~ 20.3V<br>28.4 ~ 32.4V<br>55.2 ~ 64.8V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~a=~~||||||| ||**WORKING TEMP.**<br>~~a=~~|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>~~a=~~||||||| ||**WORKING HUMIDITY**<br>~~a=~~|20 ~ 90% RH non-condensing<br>~~a=~~||||||| ||**STORAGE TEMP., HUMIDITY**<br>~~a=~~|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>~~a=~~||||||| ||**TEMP. COEFFICIENT**<br>~~a=~~|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>~~a=~~||||||| ||**VIBRATION**<br>~~a=~~|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>~~a=~~||||||| ||**SAFETY STANDARDS**<br>**OPERATING ALTITUDE Note.6** <br>~~a=~~|IEC62368-1, UL62368-1, TUV EN62368-1, IEC60601-1, TUV EN60601-1, UL ANSI / AAMI ES60601-1(3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3,<br>approved; Design refer to EN60335 1<br>-<br>EAC TP TC 004<br> 3000 meters<br>~~a=~~||||||| ||**ISOLATION LEVEL**|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25<br>/ 70% RH<br>℃||||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**|||**Standard**||**Test Level / Note**|| |||Conducted emission|||EN55011 (CISPR11)||Class B|| |||Radiated emission|||EN55011 (CISPR11)||Class B|| |||Harmonic current|||EN61000-3-2||Class A|| |||Voltage flicker|||EN61000-3-3||-----|| |||EN60601-1-2||||||| |||**Parameter**|||**Standard**||**Test Level / Note**|| |||ESD|||EN61000-4-2||Level 4, 15KV air ; Level 4, 8KV contact|| |||RF field susceptibility|||EN61000-4-3||Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )|| |||EFT bursts|||EN61000-4-4||Level 3, 2KV|| |||Surge susceptibility|||EN61000-4-5||Level 4, 4KV/Line-FG; 2KV/Line-Line|| |||Conducted susceptibility|||EN61000-4-6||Level 3, 10V|| |||Magnetic field immunity|||EN61000-4-8||Level 4, 30A/m|| |||Voltage dip, interruption|||EN61000-4-11||100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods|| |||353.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| ||**DIMENSION (L*W*H)**|101.6*50.8*29mmor 4" * 2" *1.141" inch||||||| ||**PACKING**<br>℃<br>6.<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Heat Sink HS1,HS2 can not be shorted.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|||||||| perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:RPS-60-SPEC 2020-10-20_ **RPS - 60 series** ## 60W Reliable Green Medical Power Supply **==> picture [476 x 615] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 100KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Output Derating<br>100<br>80<br>60<br>50<br>40<br>20<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>Output Derating VS Input Voltage<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 95 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RPS-60-SPEC 2020-10-20_ **RPS - 60 series** ## 60W Reliable Green Medical Power Supply **==> picture [391 x 337] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Top View<br>101.6<br>95.25 3.175<br>HS2<br>FS1 AC FUSE<br>T2.5/250V SVR1<br>3<br>CN1 2<br>1 1<br>2<br>FS2 3<br>AC FUSE 4<br>T2.5/250V<br>HS1 CN2<br>M1 M2<br>4-ψ3.3<br>Side View<br>3 max.<br>3.175<br>50.8 44.45<br>29<br>**----- End of picture text -----**<br> **==> picture [28 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Unit:mm<br>**----- End of picture text -----**<br> AC Input Connector (CN1) : JST B3P-VH or equivalent |Pin No.|Assignmen|t<br>Mating Housing|Terminal| |---|---|---|---| |1|AC/N|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent| |2|No Pin||| |3|AC/L||| DC Output Connector (CN2) : JST B4P-VH or equivalent |Pin No.|Assignment|Mating Housing|Terminal| |---|---|---|---| |1,2|+V|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent| |3,4|-V||| : Grounding Required 1.HS1,HS2 cannot be shorted. 2.M1 is safety ground. For better EMC performance, Please secure an electrical connection between M1,M2 and chassis grounding. ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:RPS-60-SPEC 2020-10-20_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →