RPS-400-18
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 401.4W @ 25CFM, 250.2 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPS-400 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13.9A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 18VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): 401.4W @ 25CFM
- Power Rating (Convection Cooling): 250.2W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 51.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RPS - 400 series**
400W Reliable Green Medical Power Supply
## ■
**==> picture [128 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
+ +<br>FOO — a B<br>■<br>**----- End of picture text -----**<br>
Ⅰ Ⅱ
**==> picture [13 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
Ⅰ Ⅱ
**==> picture [203 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
■ Model Encoding<br>RPS - 400- 12<br>Type<br>Lt Output voltage<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
## **SPECIFICATION**
||**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(main output )**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**(max.)**<br>**OPERATING ALTITUDE Note.6**|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(main output )**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**(max.)**<br>**OPERATING ALTITUDE Note.6**|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(main output )**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**(max.)**<br>**OPERATING ALTITUDE Note.6**|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(main output )**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT (Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**5V STANDBY**<br>**FAN SUPPLY**<br>**PS-ON INPUT SIGNAL**<br>**POWER GOOD / POWER FAIL**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**(max.)**<br>**OPERATING ALTITUDE Note.6**|**RPS-400-12**|**RPS-400-15**|**RPS-400-18**|**RPS-400-24**|**RPS-400-27**|**RPS-400-36**|**RPS-400-48**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||**DC VOLTAGE**|||12V|15V|18V|24V|27V|36V|48V|
|||**CURRENT**<br>**25CFM**<br>**25CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**RIPPLE & NOISE (max.) Note.2**|**25CFM**||33.3A|26.7A|22.3A|16.7A|14.9A|11.2A|8.4A|
||||**Convection**||20.8A|16.7A|13.9A|10.5A|9.3A|7A|5.3A|
||||**25CFM**||399.6W|400.5W|401.4W|400.8W|402.3W|403.2W|403.2W|
||||**Convection**||249.6W|250.5W|250.2W|252W|251.1W|252W|254.4W|
||||||120mVp-p|120mVp-p|150mVp-p|150mVp-p|200mVp-p|200mVp-p|200mVp-p|
|||**VOLTAGE ADJ. RANGE(main output )**|||11.4~12.6V|14.3~15.8V|17.1~18.9V|22.8~25.2V|25.6 ~ 28.4V|34.2 ~37.8V|45.6 ~50.4V|
|||**VOLTAGE TOLERANCE Note.3**|||±3.0%|±3.0%|±3.0%|±2.0%|±1.0%|±1.0%|±1.0%|
|||**LINE REGULATION**|||±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|
|||**LOAD REGULATION**|||±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|
|||**SETUP, RISE TIME**|||1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load|||||||
|||**HOLD UP TIME (Typ.)**|||16ms/230VAC 16ms/115VAC at full load|||||||
|||**VOLTAGE RANGE**<br>**Note.4**|||80 ~ 264VAC 113 ~ 370VDC|||||||
|||**FREQUENCY RANGE**|||47 ~ 63Hz|||||||
|||**POWER FACTOR**|||PF>0.94/230VAC PF>0.98/115VAC at full load|||||||
|||**EFFICIENCY (Typ.)**|||91.5%|92%|93%|93%|93.5%|94%|94%|
|||**AC CURRENT (Typ.)**|||4.2A/115VAC 2.1A/230VAC|||||||
|||**INRUSH CURRENT (Typ.)**|||COLD START 35A/115VAC 70A/230VAC|||||||
|||**LEAKAGE CURRENT**<br>**Note.5**<br>**(max.)**|||Earth leakage current <200 A/264VAC 50Hz , Touch current < 70 A/264VAC<br>μ<br>μ|||||||
|||**OVERLOAD**|||105 ~ 135% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||||
|||**OVER VOLTAG**||**E**|16.5 ~ 19.5V<br>29.7 ~ 35.1V<br>39.6 ~ 46.8V<br>13.2 ~ 15.6V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>52.8 ~ 62.4V<br>19.8 ~23.4V<br>26.4 ~ 31.2V|||||||
|||**OVER TEMPERATURE**|||Protection type :Shut down o/p voltage, recovers automatically after temperature goes down|||||||
|||**5V STANDBY**|||5Vsb : 5V@0.6A without fan, 1A with fan 25CFM ;<br>Tolerance<br>2%, ripple : 120mVp-p(max.)<br>±|||||||
|||**FAN SUPPLY**|||12V@0.5A for driving fan ;<br>Tolerance<br>10%<br>±|||||||
|||**PS-ON INPUT SIGNAL**|||Power on: PS-ON = "Hi" or " > 2 ~ 5V" ;<br>Power off: PS-ON = "Low" or " < 0 ~ 0.5V"|||||||
|||**POWER GOOD / POWER FAIL**|||500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ;<br>The TTL signal goes low at least 1ms before Vo below 90% of rated value|||||||
|||**WORKING TEMP.**|||-30 ~ +70<br>(Refer to "Derating Curve")<br>℃|||||||
|||**WORKING HUMIDITY**|||20 ~ 90% RH non-condensing|||||||
|||**STORAGE TEMP., HUMIDITY**|||-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||||
|||**TEMP. COEFFICIENT**|||±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||||
|||**VIBRATION**|||10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||||||
|||**OPERATING ALTITUDE Note.6**|||4000 meters|||||||
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
## **SPECIFICATION**
|**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**OTHERS**<br>**NOTE**|**SAFETY STANDARDS**|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|IEC60601-1, TUV EN60601-1,<br>,<br>EAC TP TC 004<br>UL ANSI / AAMI ES60601-1 (3.1 version),<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;<br>Design refer to EN60335 1<br>-|
|---|---|---|---|---|---|---|---|---|
||**ISOLATION LEVEL**|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP|||||||
||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||||||
||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||||
||**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>**Test Level / Note**<br>Class B(Please see last page note1)<br>Class B(Please see last page note1)<br>Class A<br>-----<br>100% dip 1 periods, 30% dip 25 periods,<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>100% interruptions 250 periods<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>194.1Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>L*W*H<br>G.W.<br>Q’TY<br>P.W.<br>RPS-400<br>127*76.2*35mm<br>0.39Kg<br>36pcs<br>15Kg<br>RPS-400-C<br>130*86*43mm<br>0.51Kg<br>24pcs<br>13.2Kg<br>RPS-400-TF<br>130*86*66.5mm<br>0.58Kg<br>24pcs<br>14.9Kg<br>RPS-400-SF<br>160*86*43mm<br>0.64Kg<br>24pcs<br>16.4Kg<br>℃<br>℃<br>ClassⅠ<br>Ⅱ<br>Class<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>Type<br>M’MENT<br>0.96CUFT<br>0.77CUFT<br>0.86CUFT<br>0.91CUFT<br>5 *3 *1 37 inch<br>″ ″ .<br>″<br>5 11 *3 39 *1.69 inch<br>.<br>″ .<br>″<br>″<br>5 11 *3 39 *2 62 inch<br>.<br>″ .<br>″ .<br>″<br>6 3 *3 39 *1.69 inch<br>. ″ .<br>″<br>″<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conducted emission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 4, 4KV/Line-FG ; 2KV/Line-Line<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 of ambient temperature.<br>2. Ripple & noise are measured at20MHz ofbandwidth by using a 12" twisted pair-wire terminated witha0.<br>&4 _ parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please checkthe derating curve for more details.<br>5. Touch currentwas measured from primary input to DC output.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher<br>than 2000m(6500ft).<br>7. The power supply is considered acomponent which will be installed into a final equipment. All the<br>(with FG) EMC tests are<br>executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The<br>(without FG) EMC tests are<br>executed by mounting the unit on a 130mm*86.6mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it stil<br>meets EMC directives. Forguidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|**Parameter**||**Standard**|||**Test Level / Note**||
|||Conducted emission||EN55011 (CISPR11)|||Class B(Please see last page note1)||
|||Radiated emission||EN55011 (CISPR11)|||Class B(Please see last page note1)||
|||Harmonic current||EN61000-3-2|||Class A||
|||Voltage flicker||EN61000-3-3|||-----||
|||EN55024 , EN60601-1-2, EN61204-3|||||||
|||**Parameter**||**Standard**|||**Test Level / Note**||
|||ESD||EN61000-4-2|||Level 4, 15KV air ; Level 4, 8KV contact||
|||RF field susceptibility||EN61000-4-3|||Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )||
|||EFT bursts||EN61000-4-4|||Level 3, 2KV||
|||Surge susceptibility||EN61000-4-5|||Level 4, 4KV/Line-FG ; 2KV/Line-Line||
|||Conducted susceptibility||EN61000-4-6|||Level 3, 10V||
|||Magnetic field immunity||EN61000-4-8|||Level 4, 30A/m||
|||Voltage dip, interruption||EN61000-4-11|||100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods||
|||194.1Khrs min. MIL-HDBK-217F (25<br>)<br>℃|||||||
|||L*W*H<br>Type|RPS-400<br>127*76.2*35mm<br>5 *3 *1 37 inch<br>″ ″ .<br>″||RPS-400-C<br>130*86*43mm<br>5 11 *3 39 *1.69 inch<br>.<br>″ .<br>″<br>″|RPS-400-TF<br>130*86*66.5mm<br>5 11 *3 39 *2 62 inch<br>.<br>″ .<br>″ .<br>″||RPS-400-SF<br>160*86*43mm<br>6 3 *3 39 *1.69 inch<br>. ″ .<br>″<br>″|
|||P.W.|0.39Kg||0.51Kg|0.58Kg||0.64Kg|
|||Q’TY|36pcs||24pcs|24pcs||24pcs|
|||G.W.|15Kg||13.2Kg|14.9Kg||16.4Kg|
|||M’MENT|0.96CUFT||0.77CUFT|0.86CUFT||0.91CUFT|
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
## 400W Reliable Green Medical Power Supply
**==> picture [464 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
Block Diagram<br>PFC fosc : 90KHz<br>PWM fosc : 100KHz<br>+5Vsb<br>DETECTION<br>CIRCUIT<br>RECTIFIERS<br>POWER SWITCHING & +5Vsb<br>PWM CONTROL FILTER<br>RECTIFIERS<br>& +12V Fan Supply<br>FILTER<br>+S<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>PFC FILTER<br>-S<br>PG PG<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>PS/ON PS-ON<br>CONTROL<br>**----- End of picture text -----**<br>
## **Output Derating vs Input Voltage**
**==> picture [241 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>90<br>80<br>70<br>60<br>50<br>40<br>80 90 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
## **Derating Curve**
**==> picture [493 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
◎ RPS-400 & RPS-400-C ◎ RPS-400-TF/SF<br>400<br>400<br>With 25CFM fan<br>|<br>|<br>250 250 |<br>RPS-400-C:115VAC Converction<br>RPS-400:115VAC Converction<br>200 { RPS-400-C:230VAC Converction 150<br>190<br>RPS-400:230VAC Converction<br>160 100<br>130 yrrt !<br>a7 50 !<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) -30 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE ( ℃ )<br>LOAD (W)<br>LOAD (W)<br>{<br>**----- End of picture text -----**<br>
**==> picture [438 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
Order No. RPS-400 RPS-400-C RPS-400-TF RPS-400-SF<br>es rs es<br>Products<br>--- ---<br>Convection 250W 250W<br>ee es ee ee<br>Force Air 400W 400W 400W 400W<br>a es<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
**==> picture [511 x 611] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mechanical Specification<br>RPS-400 (PCB Type)<br>Top View<br>127<br>5.7 115.6<br>HS1 CN95<br>HS4<br>3 1<br>4 2<br>21<br>43<br>HS2 HS3 -V<br>CN1 +V<br>1<br>3<br>1<br>F8A<br>250V 2<br>FS1<br>FG<br>Air flow<br>direction<br>FAN<br>25CFM<br>63.5<br>Side View<br>4-<br>ψ<br>3.5<br>5.7<br>76.2 64.8<br>35<br>3.0 max.<br>SVR1<br>CN11<br>CN12<br>ACL ACN<br>5cm<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
**==> picture [511 x 700] intentionally omitted <==**
**----- Start of picture text -----**<br>
RPS-400-C (Enclosed type) Case No. 247A Unit:mm<br>126<br>5.0<br>120<br>2 2<br>R1.75<br>110.5 15.5<br>Side View<br>Side View<br>Air flow Top View Side View<br>direction<br>FAN<br>25CFM<br>57<br>Side View<br>130<br>5<br>120<br>1 1<br>1 Bottom View 1<br>4-M3 L=2<br>2-M3 L=4<br>26.5 43<br>38.7<br>5cm<br>18.3<br>86 50<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
**==> picture [511 x 668] intentionally omitted <==**
**----- Start of picture text -----**<br>
RPS-400-TF (Enclosed type with fan on the top) Case No. 247A-D 247B-T Unit:mm<br>126<br>5.0<br>120<br>2 2<br>15.5<br>Side View<br>Side View Top View Side View<br>Air flow<br>direction<br>Side View<br>130<br>5<br>120<br>1 1<br>1 Bottom View 1<br>4-M3 L=2<br>2-M3 L=4 R1.75<br>26.5<br>38.7 43<br>15.5<br>18.3<br>86<br>50<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
**==> picture [357 x 629] intentionally omitted <==**
**----- Start of picture text -----**<br>
RPS-400-SF (Enclosed type with fan on the side)<br>160<br>Side View<br>Air flow<br>direction<br>Side View Side View<br>Top View<br>Side View<br>130<br>5.0<br>1 1<br>120<br>Bottom View<br>4-M3 L=2<br>43<br>86<br>50<br>45.6<br>**----- End of picture text -----**<br>
**==> picture [84 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Case No. 248A Unit:mm<br>**----- End of picture text -----**<br>
_File Name:RPS-400-SPEC 2020-10-20_
**RPS - 400 series**
400W Reliable Green Medical Power Supply
## ※ **Mounting Instruction for -C -TF/ /-SF Type**
|Hole No.|Recommended Screw Size|MAX. Penetration DepthL|Recommended mountingtorque|
|---|---|---|---|
|1|M3|2mm|4~ Kgf-cm<br>6|
|2|M3|4mm|4~ Kgf-cm<br>6|
|Mounting Screw<br>Mounting SurfaceChassis of RPS-400-C/TF/SF<br>L||||
## ※ **CONNECTION**
AC Input Connector (CN1) : JST B3P-VH or equivalent
|Pin No.|Assignment|Mating Housing|Terminal|
|---|---|---|---|
|1|AC/N|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent|
|2|No Pin|||
|3|AC/L|||
Function Connector(CN11): TKP DH2I-2X2 or equivalent
|Pin No.|Assignment|Mating Housing|Terminal|
|---|---|---|---|
|1|-S|TKP DH2<br>or equivalent|TKP<br>or equivalent|
|2|+S|||
|3|DC COM|||
|4|PG|||
DC Output Connector (CN2,CN3)
|Pin No.|Assignment|Output Terminals|
|---|---|---|
|CN2|-V|M3.5 Pan HD screw in 2 positions<br>Torque to 8 lbs-in(90cNm)max.|
|CN3|+V||
����������������������������������
Function Connector(CN95): TKP DH2L-2X2 or equivalent
|Pin No.|Assignment|Mating Housing|Terminal|
|---|---|---|---|
|1|5Vsb|TKP DH2<br>or equivalent|TKP<br>or equivalent|
|2,4|DC COM|||
|3|PS-ON|||
|FAN Connector(CN12) : TKP 8812-2 or equivalent<br>(Except for RPS-400-TF/SF)||||
|Pin No.|Assignment|MatingHousing|Terminal|
|1|DC COM|TKP 2502<br>or equivalent|TKP 8811<br>or equivalent|
|2|+12V|||
- ※ Note: 1. When the input voltage is 230VAC, the PCB type (Blank-Type) model delivers EMI Class B for both conducted emission and radiated emission for the power supply; When the input voltage is 110VAC, the PCB type (Blank Type) model delivers EMI Class B for conducted emission and Class A for radiated emission for the power supply. It delivers Class A for conducted emission and radiated emission, when configured into ClassⅡ (no FG) system.
2. The enclosed type (-C/TF/SF type) models are not suitable for configuration within a ClassⅡ (without FG) system, but suggested within a ClassⅠ(with FG) system.
3. Mounting Instruction for enclosed type.
## **Installation Manual**
Please refer to : http://www.meanwell.com/manual.html
_File Name:RPS-400-SPEC 2020-10-20_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →