Image not available
Illustrative purposes only
RPS-30-5
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 30 W, 80V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):30W; Power Rating (Forced Cooling):-; Input Voltage VAC:80V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; Output
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPS-30 Series
- No. of Outputs: 1 Output
- Output Power Max: 30W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 30W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 12.01 € |
| Current stock | 200+ |
| Lead time | 30 days |
**RPS-30 series** 30W Single Output Medical Type ## **Features** 3"×2" miniature size Oral irrigator Universal AC input / Full range Hemodialysis machine ClassⅡ(without FG) installations Medical monitors Medical safety approved Sleep apnea devices (2 x MOPP between primary to secondary) Suitable for BF application with appropriate system consideration Low leakage current <100μA No load power consumption<0.1W High efficiency up to 91% For 1U applications Protections: Short circuit / Overload / Over voltage Cooling by free air convection -30~70℃wide range of operating temperature LED indicator for power on 3 years warranty ## **Description** RPS-30 is a 30W highly reliable green PCB type medical power supply with a high power density on the 3” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.1W. RPS-30 is able to be used for ClassⅡ(no FG) system design. The extremely low leakage current is less than 100μA. In addition, it conforms to international medical regulations (2*MOPP) and EMC EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.a _File Name:R_ PS-30 _-SPEC 2015-11-04_ **RPS-30 series** 30W Single Output Medical Type ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|**SPECIFICATION**|| |---|---|---|---| |**VOLTAGE TOLERANCE**<br>I/P-O/P: 4KVAC<br>**VOLTAGE ADJ.RANGE**<br>3.8~5V<br>5.7~6.8V<br>8.62~11.3V<br>13.8~16.2V<br>17.25~20.3V<br>28.4~32.4V<br>55.2~64.8V<br>**ORDER NO.**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**5**<br>**Note.**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note. 8)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>**RPS 30 3 3**<br>-<br>- .<br>3.3V<br>80mVp-p<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>±0.5%<br>±1.0%<br>80 ~ 264VAC<br>47 ~ 63Hz<br>80%<br>1A / 115VAC 0.5A / 230VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>628.7 hrs min.<br>K<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>0.09Kg; 120pcs/11.8Kg/0.97CUFT<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2 medical level, criteria A<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>115 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>6A<br>0 ~ 6 6A<br>.<br>19.8W<br>Protection type :Shut down o/p voltage, re-power on to recover<br>ANSI/AAMI ES60601-1 TUV EN60601-1 EN60601-1-1 approved<br>,<br>,<br>Compliance to EN55011(CISPR11) class B, EN61000-3-2,3<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load<br>50ms / 230VAC 12ms / 115VAC at full load<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>СOLD STAR 30A/115VAC 60A/230VAC<br>±0.03% /<br>(0 ~ 50<br>)<br>℃<br>℃<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>��������������������������������<br>�����������������������������������������������������������<br>℃<br>7.<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)<br>**PEAK LOAD(10sec.)**<br>**Note.2** 21.8W<br>3.1~3.6V<br>±2.0%<br>Touch current< 100 A/264VAC<br>**RPS 30**<br>-<br>-**5**<br>5V<br>80mVp-p<br>±0.5%<br>±1.0%<br>82%<br>6A<br>0 ~ 6 6A<br>.<br>30W<br>33W<br>4 7 5 5<br>. ~ . V<br>±2.0%<br>**RPS 30**<br>-<br>- .**7 5**<br>7.5V<br>80mVp-p<br>±0.5%<br>±1.0%<br>84%<br>0 ~ 4 4A<br>.<br>30W<br>33W<br>7.12~8.3V<br>±2.0%<br>**RPS 30**<br>-<br>-**12**<br>12V<br>120mVp-p<br>±0.5%<br>±1.0%<br>88%<br>4A<br>0 ~ 2.75A<br>11.4~13.2V<br>±2.0%<br>**RPS 30**<br>-<br>-**15**<br>15V<br>150mVp-p<br>±0.5%<br>±1.0%<br>89%<br>2.5A<br>0 ~ 2 2A<br>.<br>13.5~16.5V<br>±2.0%<br>**RPS 30**<br>-<br>-**24**<br>24V<br>240mVp-p<br>±0.5%<br>±1.0%<br>89.5%<br>1.25A<br>0 ~ 1.375A<br>22.8~27.6V<br>±1.0%<br>**RPS 30**<br>-<br>-**48**<br>48V<br>300mVp-p<br>±0.5%<br>±1.0%<br>91%<br>0.625A<br>0 ~ 0.687A<br>45.6~52.8V<br>±1.0%<br>2A<br>30W<br>33W<br>30W<br>33W<br>30W<br>33W<br>30W<br>33W<br>76.2*50.8*24mm<br>(L*W*H)<br>or 3" * 2" *0.945" inch<br>MIL-HDBK-217(25<br>)<br>℃|||| ||**VOLTAGE TOLERANCE**<br>I/P-O/P: 4KVAC<br>**VOLTAGE ADJ.RANGE**<br>3.8~5V<br>5.7~6.8V<br>8.62~11.3V<br>13.8~16.2V<br>17.25~20.3V<br>28.4~32.4V<br>55.2~64.8V<br>**ORDER NO.**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**5**<br>**Note.**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note. 8)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>**RPS 30 3 3**<br>-<br>- .<br>3.3V<br>80mVp-p<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>±0.5%<br>±1.0%<br>80 ~ 264VAC<br>47 ~ 63Hz<br>80%<br>1A / 115VAC 0.5A / 230VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>628.7 hrs min.<br>K<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>0.09Kg; 120pcs/11.8Kg/0.97CUFT<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2 medical level, criteria A<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>115 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>6A<br>0 ~ 6 6A<br>.<br>19.8W<br>Protection type :Shut down o/p voltage, re-power on to recover<br>ANSI/AAMI ES60601-1 TUV EN60601-1 EN60601-1-1 approved<br>,<br>,<br>Compliance to EN55011(CISPR11) class B, EN61000-3-2,3<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load<br>50ms / 230VAC 12ms / 115VAC at full load<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>СOLD STAR 30A/115VAC 60A/230VAC<br>±0.03% /<br>(0 ~ 50<br>)<br>℃<br>℃<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>��������������������������������<br>�����������������������������������������������������������<br>℃<br>7.<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)<br>**PEAK LOAD(10sec.)**<br>**Note.2** 21.8W<br>3.1~3.6V<br>±2.0%<br>Touch current< 100 A/264VAC<br>**RPS 30**<br>-<br>-**5**<br>5V<br>80mVp-p<br>±0.5%<br>±1.0%<br>82%<br>6A<br>0 ~ 6 6A<br>.<br>30W<br>33W<br>4 7 5 5<br>. ~ . V<br>±2.0%<br>**RPS 30**<br>-<br>- .**7 5**<br>7.5V<br>80mVp-p<br>±0.5%<br>±1.0%<br>84%<br>0 ~ 4 4A<br>.<br>30W<br>33W<br>7.12~8.3V<br>±2.0%<br>**RPS 30**<br>-<br>-**12**<br>12V<br>120mVp-p<br>±0.5%<br>±1.0%<br>88%<br>4A<br>0 ~ 2.75A<br>11.4~13.2V<br>±2.0%<br>**RPS 30**<br>-<br>-**15**<br>15V<br>150mVp-p<br>±0.5%<br>±1.0%<br>89%<br>2.5A<br>0 ~ 2 2A<br>.<br>13.5~16.5V<br>±2.0%<br>**RPS 30**<br>-<br>-**24**<br>24V<br>240mVp-p<br>±0.5%<br>±1.0%<br>89.5%<br>1.25A<br>0 ~ 1.375A<br>22.8~27.6V<br>±1.0%<br>**RPS 30**<br>-<br>-**48**<br>48V<br>300mVp-p<br>±0.5%<br>±1.0%<br>91%<br>0.625A<br>0 ~ 0.687A<br>45.6~52.8V<br>±1.0%<br>2A<br>30W<br>33W<br>30W<br>33W<br>30W<br>33W<br>30W<br>33W<br>76.2*50.8*24mm<br>(L*W*H)<br>or 3" * 2" *0.945" inch<br>MIL-HDBK-217(25<br>)<br>℃||**RPS 30 3 3**<br>-<br>- .<br>**RPS 30**<br>-<br>-**5**<br>**RPS 30**<br>-<br>- .**7 5**<br>**RPS 30**<br>-<br>-**12**<br>**RPS 30**<br>-<br>-**15**<br>**RPS 30**<br>-<br>-**24**<br>**RPS 30**<br>-<br>-**48**| |||**DC VOLTAGE**|3.3V<br>5V<br>7.5V<br>12V<br>15V<br>24V<br>48V| |||**RATED CURRENT**|6A<br>6A<br>4A<br>2.5A<br>1.25A<br>0.625A<br>2A| |||**CURRENT RANGE**|0 ~ 6 6A<br>.<br>0 ~ 6 6A<br>.<br>0 ~ 4 4A<br>.<br>0 ~ 2.75A<br>0 ~ 2 2A<br>.<br>0 ~ 1.375A<br>0 ~ 0.687A| |||**RATED POWER**|19.8W<br>30W<br>30W<br>30W<br>30W<br>30W<br>30W| |||**PEAK LOAD(10sec.)**<br>**Note.2**|21.8W<br>33W<br>33W<br>33W<br>33W<br>33W<br>33W| |||**RIPPLE & NOISE (max.) Note.3**|80mVp-p<br>80mVp-p<br>80mVp-p<br>120mVp-p<br>150mVp-p<br>240mVp-p<br>300mVp-p| |||**VOLTAGE ADJ.RANGE**|3.1~3.6V<br>4 7 5 5<br>. ~ . V<br>7.12~8.3V<br>11.4~13.2V<br>13.5~16.5V<br>22.8~27.6V<br>45.6~52.8V| |||**VOLTAGE TOLERANCE**|±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%| |||**LINE REGULATION**|±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%| |||**LOAD REGULATION**|±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%| |||**SETUP, RISE TIME**|200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load| |||**HOLD UP TIME (Typ.)**|50ms / 230VAC 12ms / 115VAC at full load| |||**VOLTAGE RANGE**<br>**5**<br>**Note.**|80 ~ 264VAC| |||**FREQUENCY RANGE**|47 ~ 63Hz| |||**EFFICIENCY (Typ.)**|80%<br>82%<br>84%<br>88%<br>89%<br>89.5%<br>91%| |||**AC CURRENT (Typ.)**|1A / 115VAC 0.5A / 230VAC| |||**INRUSH CURRENT (Typ.)**|СOLD STAR 30A/115VAC 60A/230VAC| |||**LEAKAGE CURRENT(max.)**|Touch current< 100 A/264VAC| |||**OVERLOAD**|115 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed| |||**OVER VOLTAGE**|3.8~5V<br>5.7~6.8V<br>8.62~11.3V<br>13.8~16.2V<br>17.25~20.3V<br>28.4~32.4V<br>55.2~64.8V<br>Protection type :Shut down o/p voltage, re-power on to recover| |||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃| |||**WORKING HUMIDITY**|20% ~ 90% RH non-condensing| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃| |||**TEMP. COEFFICIENT**|±0.03% /<br>(0 ~ 50<br>)<br>℃<br>℃| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br> <br>| |||**SAFETY STANDARDS**|ANSI/AAMI ES60601-1 TUV EN60601-1 EN60601-1-1 approved<br>,<br>,| |||**ISOLATION LEVEL**|Primary-Secondary: 2xMOPP| |||**WITHSTAND VOLTAGE**|I/P-O/P: 4KVAC| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃| |||**EMC EMISSION**|Compliance to EN55011(CISPR11) class B, EN61000-3-2,3| |||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2 medical level, criteria A| |||**MTBF**|628.7 hrs min.<br>K<br>MIL-HDBK-217(25<br>)<br>℃| |||**DIMENSION**|76.2*50.8*24mm<br>(L*W*H)<br>or 3" * 2" *0.945" inch| |||**PACKING**<br>0.09Kg; 120pcs/11.8Kg/0.97CUFT<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>��������������������������������<br>�����������������������������������������������������������<br>℃<br>7.<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)|| _File Name:R_ PS-30 _-SPEC 2015-11-04_ **RPS-30 series** 30W Single Output Medical Type **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 65KHz<br>EMI FILTER RECTIFIERS POWER RECTIFIERS +V<br>I/P & & &<br>SWITCHING -V<br>RECTIFIER FILTER FILTER<br>DETECTION<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:R_ PS-30 _-SPEC 2015-11-04_ **RPS-30 series** 30W Single Output Medical Type **==> picture [481 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. Unit:mm<br>76.2<br>3.175<br>69.85<br>HS2<br>FS1<br>AC FUSE<br>T2A/250V<br>3<br>2<br>CN2<br>1<br>1<br>CN1<br>2<br>LED<br>SVR1<br>4-ψ3.2<br>AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN2) : JST B2P-VH or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal<br>1 AC/N 1 +V JST VHR JST SVH-21T-P1.1<br>JST VHR JST SVH-21T-P1.1<br>2 No Pin 2 -V or equivalent or equivalent<br>or equivalent or equivalent<br>3 AC/L<br>3 max.<br>24<br>50.8 44.45<br>3.175<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html _File Name:R_ PS-30 _-SPEC 2015-11-04_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →