Image not available
Illustrative purposes only
RPS-160-24
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 161W @ 20.5CFM, 113.4 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPS-160 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): 161W @ 20.5CFM
- Power Rating (Convection Cooling): 113.4W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 46.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RPS - 160 series** ## 160W Reliable Green Medical Power Supply ## ■ ## + + ey) ECO | Medical ■ EMI class B for class Ⅰ configuration **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> Ⅰ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:RPS-160-SPEC 2020-10-20_ **RPS - 160 series** 160W Reliable Green Medical Power Supply ## **SPECIFICATION** **==> picture [497 x 694] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |MODEL|RPS|□|-160-5|RPS|□|-160-12|RPS|□|-160-15|RPS|□|-160-24|RPS|□|-160-48| |DC VOLTAGE|5V|12V|15V|24V|48V| |RATED CURRENT (20.5CFM)|30A|12.9A|10.3A|6.5A|3.25A| |Convection|0 ~ 20A|0 ~ 9.1A|0 ~ 7.3A|0 ~ 4.6A|0 ~ 2.3A| |CURRENT| |20.5CFM|0 ~ 30A|0 ~ 12.9A|0 ~ 10.3A|0 ~ 6.5A|0 ~ 3.25A| |RATED|Convection|Note.2|103W|112.2W|112.5W|113.4W|113.4W| |POWER|20.5CFM|Note.3|155W|159.8W|159.5W|161W|161W| |OUTPUT|RIPPLE & NOISE (max.)|Note.4|80mVp-p|80mVp-p|120mVp-p|120mVp-p|150mVp-p| |VOLTAGE ADJ. RANGE(main output)|4.5 ~ 5.5V|10.8 ~ 13.2V|13.5 ~ 16.5V|22 ~ 27V|43.2 ~ 52.8V| |VOLTAGE TOLERANCE|Note.5|±4.0%|±3.0%|±3.0%|±2.0%|±2.0%| |LINE REGULATION|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |LOAD REGULATION|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| |SETUP, RISE TIME|1800ms, 30ms/230VAC 3500ms, 30ms/115VAC at full load| |HOLD UP TIME (Typ.)|20ms/115VAC 25ms/230VAC at full load| |VOLTAGE RANGE|Note.6|90 ~ 264VAC 127 ~ 370VDC| |FREQUENCY RANGE|47 ~ 63Hz| |POWER FACTOR (Typ.)|PF>0.93/230VAC PF>0.98/115VAC at full load| |INPUT|EFFICIENCY (Typ.)|86%|87%|87%|87%|88%| |AC CURRENT (Typ.)|2A/115VAC 1.1A/230VAC| |INRUSH CURRENT (Typ.)|COLD START 35A/115VAC 70A/230VAC| |LEAKAGE CURRENT|Note.7|Earth leakage current < 160|μ|A/264VAC , Touch current < 100|μ|A/264VAC| |105 ~ 135% rated output power| |OVERLOAD| |Protection type : Hiccup mode, recovers automatically after fault condition is removed| |5.7 ~ 6.8V|13.8 ~ 16.2V|17.2 ~ 20.3V|27.6 ~ 32.4V|55.2 ~ 64.8V| |PROTECTION|OVER VOLTAGE| |Protection type : Shut down o/p voltage, re-power on to recover| |TSW1: Shut down o/p voltage, recovers automatically after temperature goes down| |OVER TEMPERATURE| |TSW2: Shut down o/p voltage, re-power on to recover| |5V STANDBY (G model)|5Vsb : 5V@0.6A without fan, 0.8A with fan 20.5CFM ; Tolerance|±|2%, ripple : 50mVp-p(max.)| |PS-ON INPUT SIGNAL (G model)|Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"| |FUNCTION| |POWER GOOD / POWER FAIL|500ms>PG>10ms PF>1ms| |REMOTE SENSE|5 ~ 15V| |WORKING TEMP.|-20 ~ +70℃|(Refer to "Derating Curve")| |WORKING HUMIDITY|20 ~ 90% RH non-condensing| |ENVIRONMENT|STORAGE TEMP., HUMIDITY|-40 ~ +85℃, 10 ~ 95% RH non-condensing| |TEMP. COEFFICIENT|±0.03%/℃|(0 ~ 50℃)| |VIBRATION|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes| |OPERATING ALTITUDE|Note.8|3000 meters| |SAFETY STANDARDS|IEC60601-1,TUV EN60601-1 approvedEAC TP TC 004; Design refer to EN60335,ANSI/AAMI ES60601-1,-CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved1|,| |ISOLATION LEVEL|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP| |WITHSTAND VOLTAGE|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC| |ISOLATION RESISTANCE|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH| |Parameter|Standard|Test Level / Note| |Conducted emission|EN55011 (CISPR11)|Class B| |EMC EMISSION|Radiated emission|EN55011 (CISPR11)|Class B| |Harmonic current|EN61000-3-2|Class A| |SAFETY &|Voltage flicker|EN61000-3-3|-----| |EMC|EN60601-1-2| |(Note 10)|Parameter|Standard|Test Level / Note| |ESD|EN61000-4-2|Level 4, 15KV air ; Level 4, 8KV contact| |Level 3, 10V/m( 80MHz~2.7GHz )| |RF field susceptibility|EN61000-4-3| |Table 9, 9~28V/m( 385MHz~5.78GHz )| |EFT bursts|EN61000-4-4|Level 3, 2KV| |EMC IMMUNITY| |Surge susceptibility|EN61000-4-5|Level 4, 4KV/Line-FG ; 2KV/Line-Line| |Conducted susceptibility|EN61000-4-6|Level 3, 10V| |Magnetic field immunity|EN61000-4-8|Level 4, 30A/m| |100% dip 1 periods, 30% dip 25 periods,| |Voltage dip, interruption|EN61000-4-11| |100% interruptions 250 periods| |MTBF|230.5K hrs min. MIL-HDBK-217F (25℃)| |OTHERS|DIMENSION (L*W*H)|127*76.2*34.6mm or 5" * 3" *1.36" inch| |PACKING|0.32Kg; 36pcs/12.5Kg/0.96CUFT| |℃| **----- End of picture text -----**<br> **NOTE** > 8. The ambient temperature derating of 3.5 ℃ /1000m with fanless models and of 5 ℃ (as available on http://www.meanwell.com) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:RPS-160-SPEC 2020-10-20_ **RPS - 160 series** ## 160W Reliable Green Medical Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc :100KHz(5V)<br>70KHz(12~48V)<br>+5VSB<br>DETECTION<br>CIRCUIT<br>RECTIFIERS<br>POWER SWITCHING & +5Vsb<br>PWM CONTROL FILTER<br>+S<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>PFC FILTER<br>-S<br>PG PG<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>PS/ON PS/ON<br>CONTROL<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>With FAN<br>90<br>80<br>Without FAN 80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RPS-160-SPEC 2020-10-20_ **RPS - 160 series** ## 160W Reliable Green Medical Power Supply **==> picture [481 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>63.5<br>FAN<br>20.5CFM min.<br>SVR1<br>M1 CN3<br>HS1 1<br>2<br>3<br>4<br>1<br>2<br>FS1 HS2 3<br>4<br>1 5<br>CN1 23 HS3 67<br>FS2 8<br>CN2<br>CN901<br>M2 CN901 LED<br>1 2 3 4<br>5 117<br>127<br>PS/ON<br>5mA(max.)<br>GND<br>4-<br>ψ<br>3.5<br>76.2 66.2<br>34.6<br>3 max.<br>5cm<br>5<br>**----- End of picture text -----**<br> |AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>Power Good Connector(CN3):JST B4B-XH or equivalent<br>Pin No.<br>1<br>2<br>3<br>4<br>Status<br>PG<br>GND<br>-S<br>+S<br>Mating Housing<br>JST XHP<br>or equivalent<br>Terminal<br>JST SXH-001T-P0.6<br>or equivalent| |---|---|---|---|---|---|---|---| |Pin No.|Assignment|Mating Housing|Terminal|Pin No.|Status|Mating Housing|Terminal| |1|AC/L|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent|1|PG|JST XHP<br>or equivalent|JST SXH-001T-P0.6<br>or equivalent| |2|No Pin|||2|GND||| |3|AC/N|||3|-S||| |||||4|+S||| DC Output Connector (CN2) : JST B8P-VH or equivalent |Pin No.|Assignment|Mating Housing|Terminal| |---|---|---|---| |1,2,3,4|+V|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent| |5,6,7,8|-V||| 5VSB Connector(CN901) : JST B-XH or equivalent |Pin No.|Assignment|Assignment|Mating Housing|Terminal| |---|---|---|---|---| |1||PS/ON|JST XHP<br>or equivalent|JST SXH-001T<br>or equivalent| |2,4||GND||| |3||5VSB||| : Grounding Required - 1.HS1,HS2,HS3 cannot be shorted. - 2.M1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2, and chassis grounding. ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:RPS-160-SPEC 2020-10-20_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →