RPD-75A
AC/DC Open Frame Power Supply (PSU), Medical, 2 Output, 95.5W @ 23.5CFM, 71 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:2 Output; Power Rating (Covection Cooling):71W; Power Rating (Forced Cooling):95.5W @ 23.5CFM; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Adjustab
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPD-75 Series
- No. of Outputs: 2 Output
- Output Power Max: 71W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7A
- Output Current - Output 2: 3A
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 12VDC
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 95.5W @ 23.5CFM
- Power Rating (Convection Cooling): 71W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 26.72 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- RPD 75 series** MEAN WELL 75W Dual Output Medical Type **- series** ~~a~~ ## ■ ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**Note.7**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>80ms/230VAC 20ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>1.5A/115VAC 1A/230VAC<br>COLD START 25A/115VAC 50A/230VAC<br>140 ~ 180% rated output power<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>569.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>127*76.2*31mm (L*W*H)<br>**OVER VOLTAGE**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>℃<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**RPD-75A**<br>5V<br>7A<br>1 ~ 9.5A<br>95.5W<br>71W<br>80mVp-p<br>CH1: 4.75 ~ 5.5V<br>±2.0%<br>±0.5%<br>±1.5%<br>CH1: 5.75 ~ 6.75V<br>77%<br>**RPD-75B**<br>12V<br>CH2<br>24V<br>CH2<br>5V<br>CH1<br>3A<br>2A<br>5A<br>0.3 ~ 4A<br>0.2 ~ 2.7A<br>1 ~ 6.8A<br>98.8W<br>73W<br>120mVp-p<br>200mVp-p<br>80mVp-p<br>CH1: 4.75 ~ 5.5V<br>±6.0%<br>±6.0%<br>±1.0%<br>±1.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±0.5%<br>±1.5%<br>79%<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>CH1<br>**OUTPUT NUMBER**<br>**PEAK LOAD (23.5CFM)**<br>Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>0.25Kg; 63pcs/16.7Kg/1.35CUFT<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VAC<br>μ<br>μ<br>**ISOLATION LEVEL**<br>Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. Heat Sink HS1,HS2,HS3 can not be shorted.<br>7. Touch current was measured from primary input to DC output.|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**Note.7**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>80ms/230VAC 20ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>1.5A/115VAC 1A/230VAC<br>COLD START 25A/115VAC 50A/230VAC<br>140 ~ 180% rated output power<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>569.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>127*76.2*31mm (L*W*H)<br>**OVER VOLTAGE**<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>℃<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**RPD-75A**<br>5V<br>7A<br>1 ~ 9.5A<br>95.5W<br>71W<br>80mVp-p<br>CH1: 4.75 ~ 5.5V<br>±2.0%<br>±0.5%<br>±1.5%<br>CH1: 5.75 ~ 6.75V<br>77%<br>**RPD-75B**<br>12V<br>CH2<br>24V<br>CH2<br>5V<br>CH1<br>3A<br>2A<br>5A<br>0.3 ~ 4A<br>0.2 ~ 2.7A<br>1 ~ 6.8A<br>98.8W<br>73W<br>120mVp-p<br>200mVp-p<br>80mVp-p<br>CH1: 4.75 ~ 5.5V<br>±6.0%<br>±6.0%<br>±1.0%<br>±1.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±0.5%<br>±1.5%<br>79%<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>CH1<br>**OUTPUT NUMBER**<br>**PEAK LOAD (23.5CFM)**<br>Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>0.25Kg; 63pcs/16.7Kg/1.35CUFT<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VAC<br>μ<br>μ<br>**ISOLATION LEVEL**<br>Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. Heat Sink HS1,HS2,HS3 can not be shorted.<br>7. Touch current was measured from primary input to DC output.|**RPD-75A**|**RPD-75A**|**RPD-75B**|**RPD-75B**| |---|---|---|---|---|---| ||**OUTPUT NUMBER**|CH1|CH2|CH1|CH2| ||**DC VOLTAGE**|5V|12V|5V|24V| ||**RATED CURRENT**|7A|3A|5A|2A| ||**CURRENT RANGE**|1 ~ 9.5A|0.3 ~ 4A|1 ~ 6.8A|0.2 ~ 2.7A| ||**RATED POWER**|71W||73W|| ||**PEAK LOAD (23.5CFM)**|95.5W||98.8W|| ||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p|80mVp-p|200mVp-p| ||**VOLTAGE ADJ. RANGE**|CH1: 4.75 ~ 5.5V||CH1: 4.75 ~ 5.5V|| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±6.0%|±2.0%|±6.0%| ||**LINE REGULATION**|±0.5%|±1.0%|±0.5%|±1.0%| ||**LOAD REGULATION**|±1.5%|±3.0%|±1.5%|±3.0%| ||**SETUP, RISE TIME**|500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load|||| ||**HOLD UP TIME (Typ.)**|80ms/230VAC 20ms/115VAC at full load|||| ||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**EFFICIENCY (Typ.)**|77%||79%|| ||**AC CURRENT (Typ.)**|1.5A/115VAC 1A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 25A/115VAC 50A/230VAC|||| ||**LEAKAGE CURRENT**<br>**Note.7**|Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VAC<br>μ<br>μ|||| ||**OVERLOAD**|140 ~ 180% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||| ||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>CH1: 5.75 ~ 6.75V|||| ||**WORKING TEMP.**|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**|ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved|||| ||**ISOLATION LEVEL**|Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| ||**EMC EMISSION**|Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3|||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A|||| ||**MTBF**|569.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|127*76.2*31mm (L*W*H)|||| ||**PACKING**|0.25Kg; 63pcs/16.7Kg/1.35CUFT|||| ||℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. Heat Sink HS1,HS2,HS3 can not be shorted.<br>7. Touch current was measured from primary input to DC output.||||| _File Name:RPD-75-SPEC 2015-08-06_ **- RPD 75 series** ## 75W Dual Output Medical Type **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>23.5CFM min. FAN<br>HS3 M2<br>M1<br>CN2<br>1<br>2<br>CN1 HS1 3<br>3 4<br>2 5 AC Input Connector (CN1) : JST B3P-VH or equivalent<br>1 67 Pin No. Assignment Mating Housing Terminal<br>HS2 8 1 AC/N<br>JST VHR JST SVH-21T-P1.1<br>2 No Pin<br>or equivalent or equivalent<br>AC FUSE 3 AC/L<br>T2.5/250V<br>FS2 FS1<br>DC Output Connector (CN2) : JST B8P-VH or equivalent<br>5.6 115.8 Pin No. Assignment Mating Housing Terminal<br>1,2 V1<br>127<br>3,4,5 COM JST VHR JST SVH-21T-P1.1<br>6,7 V2 or equivalent or equivalent<br>8 NC<br>: Grounding Required<br>1.HS1,HS2,HS3 cannot be shorted.<br>2.M1 is safety ground. For better EMC<br>performance,Please secure an electrical<br>connection between M1,M2 and chassis<br>grounding.<br>Block Diagram<br>fosc : 65KHz<br>RECTIFIERS<br>& +V2<br>FILTER<br>EMI RECTIFIERS POWER RECTIFIERS +V1<br>I/P FILTER & SWITCHING & COM<br>FILTER FILTER<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>133<br>23.5CFM Forced air Cooling 90<br>100<br>Convection Cooling 80<br>80 70<br>60<br>50<br>50<br>20<br>40<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>4-<br>ψ<br>3.8<br>LOAD (%) LOAD (%)<br>5.7<br>76.2 64.75<br>31<br>15cm<br>3max.<br>**----- End of picture text -----**<br> _File Name:RPD-75-SPEC 2015-08-06_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →