RPD-60B
AC/DC Open Frame Power Supply (PSU), Medical, 2 Output, 53.5 W, 90V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:2 Output; Power Rating (Covection Cooling):53.5W; Power Rating (Forced Cooling):-; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Fixed; Output Volt
- SVHC: No SVHC (25-Jun-2025)
- Product Range: RPD-60 Series
- No. of Outputs: 2 Output
- Output Power Max: 53.5W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.5A
- Output Current - Output 2: 1.5A
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 24VDC
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 53.5W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 16.99 € |
| Current stock | 10+ |
| Lead time | 30 days |
~~oe~~ 60W Dual Output Medical Grade ## **- RPD 60 series** **==> picture [42 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual .<br>**----- End of picture text -----**<br> **==> picture [14 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>**----- End of picture text -----**<br> **==> picture [53 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> + +<br>**----- End of picture text -----**<br> ## ■ ## ■ 4"×2" compact size Medical safety approved (2 x MOPP) accroding to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1 Suitable for BF application with appropriate system consideration Cooling by free air convection EMI class B for class Ⅰ configuration Extremely low leakage current ■ Protections: Short circuit / Overload / Over voltage MW Search: https://www.meanwell.com/serviceGTIN.aspx ~~a~~ 3 years warranty ## **Description** RPD-60 is a 60W highly reliable green PCB type medical power supply with a high power density on the 4” by 2” footprint. It accepts 90~264VAC input and offers dual output voltages . RPD-60 is able to be used for ClassⅠ (with FG) system design. The extremely low leakage current is less than 150 μ A. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011. _File Name:RPD-60-SPEC 2022-09-20_ **- RPD 60 series** > 60W Reliable Dual Output Medical Grade ## **SPECIFICATION** |**MODEL**<br>**RPD-60A**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION (L*W*H)**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>5A<br>0.5 ~ 5.5A<br>49W<br>53.9W<br>80mVp-p<br>+3,-2%<br>±0.5%<br>±1.5%<br>300ms, 15ms/230VAC 300ms, 15ms/115VAC at full load<br>70ms/230VAC 14ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>CH1: 5.75 ~ 6.75V<br>78%<br>1.1A/115VAC 0.7 A/230VAC<br>COLD START 60A/230VAC 30A/115VAC<br>115 ~ 150% rated output power<br>-20 ~ +65<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>101.6*50.8*29mm or 4" * 2" *1.14" inch<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**PROTECTION**<br>℃<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**RPD-60B**<br>12V<br>CH2<br>24V<br>CH2<br>5V<br>CH1<br>2A<br>1.5A<br>3.5A<br>0.1 ~ 2.2A<br>0.1 ~ 1.65A<br>0.5 ~ 3.85A<br>53.5W<br>58.85W<br>80mVp-p<br>100mVp-p<br>80mVp-p<br>±6.0%<br>+8,-4%<br>±1.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>+3,-2%<br>±0.5%<br>±1.5%<br>82%<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>CH1<br>**OUTPUT NUMBER**<br>**PEAK LOAD(10sec.)**<br>**Note.2**<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>Earth leakage current < 150<br>A/264VAC , Touch current < 100<br>A/264VAC<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>BS EN/EN55011 (CISPR11)<br>BS EN/EN55011 (CISPR11)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>Level 4, 4KV/Line-FG ; 2KV/Line-Line<br>Level 4, 15KV air ; Level 4, 8KV contact<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conducted emission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>μ<br>μ<br>BS EN/EN55035,BS EN/EN60601-1-2<br>**OPERATING ALTITUDE Note.6** 3000 meters<br>UL62368-1,TUV BS EN/EN62368-1,IEC62368-1,IEC60601-1,<br>UL ANSI/AAMI ES60601-1,<br>EAC TP TC 004,<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved,TUV BS EN/EN60601-1 approved<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>5031.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 679.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~SSS~~<br>~~==~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>8. Heat Sink HS1,HS2 can not be shorted.<br>9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|**MODEL**<br>**RPD-60A**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**Note.5**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION (L*W*H)**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>5A<br>0.5 ~ 5.5A<br>49W<br>53.9W<br>80mVp-p<br>+3,-2%<br>±0.5%<br>±1.5%<br>300ms, 15ms/230VAC 300ms, 15ms/115VAC at full load<br>70ms/230VAC 14ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>CH1: 5.75 ~ 6.75V<br>78%<br>1.1A/115VAC 0.7 A/230VAC<br>COLD START 60A/230VAC 30A/115VAC<br>115 ~ 150% rated output power<br>-20 ~ +65<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>101.6*50.8*29mm or 4" * 2" *1.14" inch<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**PROTECTION**<br>℃<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**RPD-60B**<br>12V<br>CH2<br>24V<br>CH2<br>5V<br>CH1<br>2A<br>1.5A<br>3.5A<br>0.1 ~ 2.2A<br>0.1 ~ 1.65A<br>0.5 ~ 3.85A<br>53.5W<br>58.85W<br>80mVp-p<br>100mVp-p<br>80mVp-p<br>±6.0%<br>+8,-4%<br>±1.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>+3,-2%<br>±0.5%<br>±1.5%<br>82%<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>CH1<br>**OUTPUT NUMBER**<br>**PEAK LOAD(10sec.)**<br>**Note.2**<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>Earth leakage current < 150<br>A/264VAC , Touch current < 100<br>A/264VAC<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>BS EN/EN55011 (CISPR11)<br>BS EN/EN55011 (CISPR11)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>Level 4, 4KV/Line-FG ; 2KV/Line-Line<br>Level 4, 15KV air ; Level 4, 8KV contact<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conducted emission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>μ<br>μ<br>BS EN/EN55035,BS EN/EN60601-1-2<br>**OPERATING ALTITUDE Note.6** 3000 meters<br>UL62368-1,TUV BS EN/EN62368-1,IEC62368-1,IEC60601-1,<br>UL ANSI/AAMI ES60601-1,<br>EAC TP TC 004,<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved,TUV BS EN/EN60601-1 approved<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>5031.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 679.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~SSS~~<br>~~==~~<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>8. Heat Sink HS1,HS2 can not be shorted.<br>9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to|**RPD-60A**|**RPD-60A**|**RPD-60A**|**RPD-60B**|**RPD-60B**|**RPD-60B**| |---|---|---|---|---|---|---|---| ||**OUTPUT NUMBER**|CH1|CH2||CH1||CH2| ||**DC VOLTAGE**|5V|12V||5V||24V| ||**RATED CURRENT**|5A|2A||3.5A||1.5A| ||**CURRENT RANGE**|0.5 ~ 5.5A|0.1 ~ 2.2A||0.5 ~ 3.85A||0.1 ~ 1.65A| ||**RATED POWER**|49W|||53.5W||| ||**PEAK LOAD(10sec.)**<br>**Note.2**|53.9W|||58.85W||| ||**RIPPLE & NOISE (max.) Note.3**|80mVp-p|80mVp-p||80mVp-p||100mVp-p| ||**VOLTAGE TOLERANCE Note.4**|+3,-2%|±6.0%||+3,-2%||+8,-4%| ||**LINE REGULATION**|±0.5%|±1.0%||±0.5%||±1.0%| ||**LOAD REGULATION**|±1.5%|±2.0%||±1.5%||±2.0%| ||**SETUP, RISE TIME**|300ms, 15ms/230VAC 300ms, 15ms/115VAC at full load|||||| ||**HOLD UP TIME (Typ.)**|70ms/230VAC 14ms/115VAC at full load|||||| ||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**EFFICIENCY (Typ.)**|78%|||82%||| ||**AC CURRENT (Typ.)**|1.1A/115VAC 0.7 A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|COLD START 60A/230VAC 30A/115VAC|||||| ||**LEAKAGE CURRENT**<br>**Note.5**|Earth leakage current < 150<br>A/264VAC , Touch current < 100<br>A/264VAC<br>μ<br>μ|||||| ||**OVERLOAD**|115 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||| ||**OVER VOLTAGE**<br>~~SSS~~|CH1: 5.75 ~ 6.75V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~SSS~~|||||| ||**WORKING TEMP.**<br>~~SSS~~|-20 ~ +65<br>(Refer to "Derating Curve")<br>℃<br>~~SSS~~|||||| ||**WORKING HUMIDITY**<br>~~SSS~~|20 ~ 90% RH non-condensing<br>~~SSS~~|||||| ||**STORAGE TEMP., HUMIDITY**<br>~~SSS~~|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>~~SSS~~|||||| ||**TEMP. COEFFICIENT**<br>~~SSS~~|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 45<br>)<br>~~SSS~~|||||| ||**VIBRATION**<br>~~SSS~~|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>~~SSS~~|||||| ||**OPERATING ALTITUDE Note.6** <br>~~SSS~~|3000 meters<br>~~SSS~~|||||| ||**SAFETY STANDARDS**<br>~~SSS~~<br>~~==~~|UL62368-1,TUV BS EN/EN62368-1,IEC62368-1,IEC60601-1,<br>UL ANSI/AAMI ES60601-1,<br>EAC TP TC 004,<br>CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved,TUV BS EN/EN60601-1 approved<br>~~SSS~~<br>~~==~~|||||| ||**ISOLATION LEVEL**<br>~~==~~|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP<br>~~==~~|||||| ||**WITHSTAND VOLTAGE**<br>~~==~~|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>~~==~~|||||| ||**MTBF**<br>**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~==~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**Parameter**<br>**Standard**<br>**Test Level / Note**<br>~~==~~|||||| |||Conducted emission<br>~~==~~||BS EN/EN55011 (CISPR11)<br>~~==~~||Class B<br>~~==~~|| |||Radiated emission<br>~~==~~||BS EN/EN55011 (CISPR11)<br>~~==~~||Class B<br>~~==~~|| |||Harmonic current<br>~~==~~||BS EN/EN61000-3-2<br>~~==~~||Class A<br>~~==~~|| |||Voltage flicker<br>~~==~~||BS EN/EN61000-3-3<br>~~==~~||-----<br>~~==~~|| |||BS EN/EN55035,BS EN/EN60601-1-2<br>~~==~~|||||| |||**Parameter**<br>~~==~~||**Standard**<br>~~==~~||**Test Level / Note**<br>~~==~~|| |||ESD<br>~~==~~||BS EN/EN61000-4-2<br>~~==~~||Level 4, 15KV air ; Level 4, 8KV contact<br>~~==~~|| |||RF field susceptibility<br>~~==~~||BS EN/EN61000-4-3<br>~~==~~||Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>~~==~~|| |||EFT bursts<br>~~==~~||BS EN/EN61000-4-4<br>~~==~~||Level 3, 2KV<br>~~==~~|| |||Surge susceptibility<br>~~==~~||BS EN/EN61000-4-5<br>~~==~~||Level 4, 4KV/Line-FG ; 2KV/Line-Line<br>~~==~~|| |||Conducted susceptibility<br>~~==~~||BS EN/EN61000-4-6<br>~~==~~||Level 3, 10V<br>~~==~~|| |||Magnetic field immunity<br>~~==~~||BS EN/EN61000-4-8<br>~~==~~||Level 4, 30A/m<br>~~==~~|| |||Voltage dip, interruption<br>~~==~~||BS EN/EN61000-4-11<br>~~==~~||100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>~~==~~|| |||5031.3K hrs min.<br>Telcordia SR-332 (Bellcore) ; 679.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~==~~|||||| ||**DIMENSION (L*W*H)**|101.6*50.8*29mm or 4" * 2" *1.14" inch|||||| ||**PACKING**<br>0.15Kg; 96pcs/15.4Kg/0.89CUFT<br>℃<br>℃<br>℃<br>(as available on http://www.meanwell.com)<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated witha0O.<br>&4 _<br>parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Touch current was measured from primary input to DC output.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>8. Heat Sink HS1,HS2 can not be shorted.<br>9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>Product Liability Disclaimer<br>For detailed information, please refer to||||||| ℃ /1000m with fanless models and of 5 ℃ /1000m (as available on http://www.meanwell.com) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:RPD-60-SPEC 2022-09-20_ **- RPD 60 series** 60W �������� Dual Output Medical Grade ## **Block Diagram** **==> picture [436 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 100KHz<br>RECTIFIERS<br>& V2<br>FILTER<br>EMI RECTIFIERS POWER RECTIFIERS +V1<br>I/P FILTER & SWITCHING & COM<br>FILTER FILTER<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **Derating Curve** **==> picture [241 x 385] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>50<br>40<br>20<br>-20 0 10 20 30 40 50 60 65 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>Output Derating VS Input Voltage<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 95 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:RPD-60-SPEC 2022-09-20_ **- RPD 60 series** 60W �������� Dual Output Medical Grade **==> picture [481 x 272] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Top View Unit:mm<br>101.6<br>95.25 3.175<br>FS1 AC FUSE HS2<br>T2.5/250V<br>3<br>CN1 2 1<br>2<br>1 3<br>4<br>FS2 5<br>AC FUSE 6<br>T2.5/250V HS1 CN2<br>M1 M2<br>4-ψ3.3<br>Side View<br>3 max.<br>3.175<br>44.45<br>29<br>50.8<br>**----- End of picture text -----**<br> |AC Input Connector (CN1) : JST B3P-VH or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent|AC Input Connector (CN1) : JST B3P-VH or equivalent| |---|---|---|---| |Pin No.|Assignment|Mating Housing|Terminal| |1|AC/N|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent| |2|No Pin||| |3|AC/L||| DC Output Connector (CN2) : JST B6P-VH or equivalent |Pin No.|Assignment|Mating Housing|Terminal| |---|---|---|---| |1,2|V1|JST VHR<br>or equivalent|JST SVH-21T-P1.1<br>or equivalent| |3,4|COM||| |5|V2||| |6|NC||| : Grounding Required - 1.HS1,HS2 cannot be shorted. - 2.M1 is safety ground. For better EMC performance, Please secure an electrical connection between M1,M2 and chassis grounding. ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:RPD-60-SPEC 2022-09-20_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →