RMD3H48MA30
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (21-Jan-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 204.23 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Solid State Relays Zero Switching Type RMD Hybrid Relay** - **Hybrid Relay: SSR + EMR combination** - **Current rating @ 60˚C: 30 AAC, 40 AAC** - **Nominal voltage ratings: 240 VAC, 227 VAC/ 480 VAC + Neutral** - **Control voltage: 24 VAC, 120 VAC, 240 VAC** - **Mercury-free, leading to a safer environment** - **Similar mounting to mercury relays** - **RoHS compliant** - **Switching with arc-free operation** - **Switching rate: up to 20 cycles per minute** - **Operating life: 4 million operating cycles** ## **Product Descri tion p** RMD3H combines the benefits of solid state relays and electromechanical relays to provide a hybrid relay. This means that there is virtually no contact arcing and much less heat emission inside the panel. RMD3H switches heaters on three legs while RMD2H has two poles which are switched and the third one is directly conneced between the L2 and the T2 terminals. This hybrid relay also provides a solution which does not contain mercury and is RoHS compliant. The maximum current reached per pole is 40AAC in a surrounding temperature of 60˚C (140˚F). ## **Ordering Key** **Hybrid Relay Number of poles Platform Rated Voltage Control voltage Rated Operational current** ## **RMD 3 H 48 HA 40** ## **Selection Guide** |**Rated Voltage**|**Blocking Voltage**|**Blocking Voltage**|**Number of**|**Rated**|**Rated operational current at 60°C surrounding temperature**|**Rated operational current at 60°C surrounding temperature**| |---|---|---|---|---|---|---| ||||**switched Poles**|**Control Voltage**|**30 Arms**|**40 Arms**| |240Vrms||600Vp|2|24 VAC/DC|RMD2H24LA30|RMD2H24LA40| |(1phase loads)||||120 VAC|RMD2H24MA30|RMD2H24MA40| |(3phase delta)||||240 VAC|RMD2H24HA30|RMD2H24HA40| |240Vrms||600Vp|3|24 VAC/ DC|RMD3H24LA30|RMD3H24LA40| |(3phase delta)||||120 VAC|RMD3H24MA30|RMD3H24MA40| |||||240 VAC|RMD3H24HA30|RMD3H24HA40| |480Vrms||600Vp|3|24 VAC/ DC|RMD3H48LA30|RMD3H48LA40| |(3phase star+Neutral)||||120 VAC|RMD3H48MA30|RMD3H48MA40| |||||240 VAC|RMD3H48HA30|RMD3H48HA40| ## **General S ecifications p** ||**RMD..24**|**RMD..48**| |---|---|---| |Operational voltage Range|240 VAC -15% / +10%|277 VAC (480 VAC with neutral| |||connection) -15%/+10%| |Non-rep peak voltage||600 Vp| |Operational frequency range||45 - 65Hz| |Power factor||> 0.90| |CE marking||Yes| |Finger Protection||IP20| |Operating life||4 million cycles| |Control input status|continuously ON|Green LED when control input is applied| |Varistor protection across outputs||420V| |Pollution degree|2 (non-conductive|pollution with possibilities of condensation)| |Over-voltage category||III (fixed installations)| |Isolation - input to Output||4000Vrms| |RoHS compliance||YES| **1** Specifications are subject to change without notice (18.01.2010) **RMD3H48HA40** ## **In ut S ecifications p p** ||**RMD..LA**||**RMD..MA**||**RMD..HA..**| |---|---|---|---|---|---| |Rated Control voltage range|24 VAC/DC +10/-15%||120 VAC +10/-15%||240 VAC +10/-15%| |Pick-up voltage|15 VAC/ 9 VDC||36 VAC||90 VAC| |Drop-out voltage|15 VAC/ 9 VDC||36 VAC||90 VAC| |Maximum Input current|400 mA||400 mA||400 mA| |Response time pick-up ZC|0.5 cycle||0.5 cycle||0.5 cycle| |Response time drop-out|2 cycles||2 cycles||2 cycles| ## **Out ut S ecifications p p** |**Output Specifications**|||| |---|---|---|---| ||**RMD..30**||**RMD..40**| |Rated operational current (see derating curve)|30 AAC||40 AAC| |Min. operational current|150 mA||150 mA| ## **Deratin Curves g** **==> picture [381 x 248] intentionally omitted <==** **----- Start of picture text -----**<br> 44<br>42<br>— | |<br>RMD..40 with AWG8<br>40<br>38 —Oe RMD..40 with<br>—_ | | | AK AWG6<br>36<br>re ee eee eee<br>34<br>— ||}<br>32<br>— | J | ft NTNI<br>RMD..30 with AWG8<br>30 a ee<br>28<br>— | | | ft<br>26 a ee<br>24<br>— ee<br>22<br>— |ff<br>20 | fT<br>— |ff<br>20°C/68°F 30°C/86°F 40°C/104°F 50°C/122°F 60°C/140°F 70°C/158°F<br>Surrounding Temperature<br>Current Rating (AAC)<br>**----- End of picture text -----**<br> **2** Specifications are subject to change without notice (18.01.2010) **RMD3H48HA40** ## **A enc A rovals & EMC g y pp** |**CE marking**|| |---|---| |Low Voltage Directive|IEC / EN 60947-4-3| |EMC Immunity|IEC / EN 61000-6-3| |EMC Emission|IEC / EN 61000-6-1| |**Electrostatic Discharge (ESD)**|| |**Immunity**|IEC / EN 61000-4-2| ||8kV, PC2 Air discharge<br>4kV, PC2 Contact| |**Electrical Fast Transient**|| |**Burst Immunity**|IEC / EN 61000-4-4| |Output<br>Input<br>**Electrical Surge Immunity**<br>Output, line to line|2kV, performance criteria 1<br>1kV, performance criteria 1<br>IEC / EN 61000-4-5<br>1kV, performance criteria 1| |Output, line to earth|2kV, performance criteria 1| |Input, line to line<br>Intput, line to earth|1kV, performance criteria 2<br>2kV, performance criteria 2| |**Radio Interference field**<br>**emissions (radiated)**|IEC / EN 55011<br>Class B (light industry)| |**Approvals**|cURus (E80573)| |---|---| |**Endurance Test**|100,000 cycle as per UL508| |**Restrictions of hazardous**|| |**substances**|RoHS| |**Radiated Radio Frequency**|| |**Immunity**|EN 61000-4-3| |10 V/m, 80 - 1000 MHz,|| |1.4 - 2.0 GHz|Performance criteria 1| |1 V/m, 2.0 - 2.7 GHz|Performance criteria 1| |**Conducted Radio Frequency**|| |**Immunity**|IEC / EN 61000-4-6| |10V/m, 0.15 - 80 MHz|Performance criteria 1| |**Voltage Dips Immunity**|IEC / EN 61000-4-11| |0% for 10ms/20ms,|| |70% for 500ms|Performance criteria 2| |40% for 200ms|Performance criteria 3| |**Voltage Interruptions Immunity**|IEC / EN 61000-4-11| |0% for 5000ms|Performance criteria 3| |**Radio Interference voltage**|EC / EN 55011| |**emissions (conducted)**|Class A (industrial)| ## **Connection S ecifications p** |Connection Type|Power Connection|Screw terminal|Control Connection|Control Connection|Control Connection|FASTON terminal|FASTON terminal| |---|---|---|---|---|---|---|---| |Illustration of terminal|=||PL||||| |Terminal Designations|1L1, 2T1, 3L2, 4T2, 5L3, 6T3, 7N||A1, A2||||| |Rigid (Solid or Stranded)|1 x (2.5-16)mm²||N/A||||| ||1 x (14-6)AWG||||||| |Tightening torque|18 in lb (2.1Nm)||N/A||||| |Size|No. 10 screw||6.35mm (1/4||inch) FASTON||| |Aperture for termination lug|Max 13.5mm for ring and||fork/spade termination|||lugs|| ## **Housin S ecifications g p** |Weight|approx. 360g|| |---|---|---| |Housing Material|PA66|| |Flame class|UL94V0|| |Dimensions (w x h x d)||| |(without input connector)|105 x 45 x 90|mm| ## **Environmental S ecifications p** |Operating Temperature|0 to 70°C| |---|---| |Storage Temperature|0 to 100°C| |Humidity|95% RH, non condensing @ 40°C| |Impact resistance|15/11 g/ms| **3** Specifications are subject to change without notice (18.01.2010) **RMD3H48HA40** ## **Connection Dia rams g** **==> picture [480 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> RMD2H<br>Line to line voltage: 240 VAC 240 VAC<br>L1 L2 L3 L N<br>N L1 L2 L3 N L1 L2 L3<br>T1 T2 T3 T1 T2 T3<br>Pele [els<br>3pole, 2 phase switching - RMD2H24.. 2pole, 1 phase switching -<br>240V heaters connected in Delta, RMD2H24..<br>with 240V 3-phase supply. 240V heater with switched Neutral<br>and Main Supply connection, in a<br>A Le 240V 1-phase system.<br>RMD3H<br>Line to line voltage: 240 VAC 480 VAC<br>L1 L2 L3 N L1 L2 L3<br>Circuit breaker<br>Overload protection<br>(may also be semiconductor fuse)<br>N L1 L2 L3 N L1 L2 L3<br>T1 T2 T3 T1 T2 T3<br>3pole, 3 phase switching - RMD3H24.. 3pole, 3 phase switching -<br>240V heaters connected in Delta, RMD3H48..<br>with 240V 3-phase supply. 240V heaters connected in<br>star(wye) with Neutral connection<br>AN supplied by a 480V 3-phase<br>system.<br>**----- End of picture text -----**<br> WARNING: Internal power supply in RMD2H and RMD3H24 is taken through terminals L1-L3, while for RMD3H48 it is taken through L1-N. If these are not connected correctly, the internal bypass relays will not work. The ‘N’ terminal must be left unconnected for RMD2H and RMD3H24. **4** Specifications are subject to change without notice (18.01.2010) **RMD3H48HA40** ## **Dimensions (mm)** **==> picture [366 x 287] intentionally omitted <==** **----- Start of picture text -----**<br> 140.7<br>48.5<br>82.6<br>97 eee<br>oH<br>i<br>14.9 6.35<br>}<br>50.7<br>24.7<br>82.6<br>97<br>**----- End of picture text -----**<br> **5** Specifications are subject to change without notice (18.01.2010)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →