Image not available
Illustrative purposes only
RM1E23AA50
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 169.68 € |
| Current stock | 25+ |
| Lead time | 15 days |
**RM1ESolid State Relays Industrial, 1-Phase Analog Switching Type RM1E** - **AC Solid State Relay** - **Analog switching (phase-angle control) for resistive and slightly inductive load applications** - **4 - 20 mA or 0 -10 V control input** - **Rated operational current: 25, 50, 100 and 125 AACrms** - **Rated operational voltage: Up to 600 VACrms** - **Variable intensity LED-indication according to input current** - **Integral snubber network** **==> picture [167 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> RM1E..AA<br>RM1E..V |<br>**----- End of picture text -----**<br> ## **Product De scri tion p** zero output power whilst 20 mA or 10 VDC correspond to full output power (near linear power response). The relay switches off every time the output cur rent cross es zero, and switches ON in ac cord ance with the ap plied control input. The analog switching relay works in accordance with the phase angle control prin ci ple, i.e., the output switching point in the AC sine wave depends on the control input which can be either 4-20 mA or 0-10 VDC. 4 mA or 0 VDC correspond to **• Polarized lockable control connector for safe connection for voltage controlled version** C€ **Orderin Ke g y RM 1E 60 AA 50 Solid State Relay** ~~.~~ | **Number of Poles Switching mode** ~~|~~ **Rated operational voltage Control input Rated operational current** ## **T e Selection yp** |**Type Selection**|||| |---|---|---|---| |**Switching mode**|**Rated operational**<br>**voltage**|**Rated operational**<br>**current**|**Control input**| |E: Analog switching|23: 230 VACrms*|25: 25 AACrms|AA: 4 - 20 mADC| ||48: 480 VACrms|50: 50 AACrms|V: 0-10 VDC**| ||60: 600 VACrms|100: 100 AACrms|| |||125: 125 AACrms|| - For nominal operational voltage of 110 VACrms, use RM1E23... ** RM1E..V.. require an external supply voltage ## **Selection Guide** |**Rated**|**Blocking**|**Control**|**Rated operational current**|**Rated operational current**||| |---|---|---|---|---|---|---| |**op. volatge**|**voltage**|**input**|**25 A 50A**|**25 A 50A**|**100 A**|**125 A**| |230 VAC|650 Vp|4 - 20 mA|RM1E23AA25|RM1E23AA50|RM1E23AA100|RM1E23AA125| |||0 - 10 VDC|RM1E23V25|RM1E23V50|RM1E23V100|RM1E23V125| |480 VAC|1200 Vp|4 - 20 mA|RM1E48AA25|RM1E48AA50|RM1E48AA100|RM1E48AA125| |||0 - 10 VDC|RM1E48V25|RM1E48V50|RM1E48V100|RM1E48V125| |600 VAC|1400 Vp|4 - 20 mA|RM1E60AA25|RM1E60AA50|RM1E60AA100|| |||0 - 10 VDC|RM1E60V25|RM1E60V50|RM1E60V100|| ## **General S ec i fi ca tions p** ||**RM 1E 23 ...**|**RM 1E 48 ...**|**RM 1E 60 ...**<br>410 to 660 VAC<br>410 to 660 VAC<br>1400 Vp<br>45 to 65 Hz<br>> 0.75<br>UR, cUR, CSA, EAC<br>Yes<br>Yes| |---|---|---|---| |Operational voltage range<br>RM1E..AA..<br>RM1E..V..|90 to 280 VAC<br>90 to 265 VAC|200 to 550 VAC<br>200 to 550 VAC|| |Blockingvoltage|650 Vp|1200 Vp|| |Operational frequencyrange|45 to 65 Hz|45 to 65 Hz|| |Power factor|> 0.75|> 0.75|| |Approvals<br>~~=~~|UR, cUR, CSA, EAC<br>~~=~~|UR, cUR, CSA, EAC|| |CE-marking<br>~~=~~|Yes<br>~~=~~|Yes|| |UKCA-marking<br>~~=~~|Yes<br>~~=~~|Yes|| * Heatsink must be connected to ground for 600 V types **1** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Out ut S ec i fi ca tions p p** |**Output Spec i fi ca tions**||||| |---|---|---|---|---| ||**RM1C...25**|**RM1C...50**|**RM1C...100**|**RM1C...125**| |Rated operational current<br>AC51 @ Ta=25oC<br>AC56a @ Ta=25oC|25 Arms<br>10 Arms|50 Arms<br>20 Arms|100 Arms<br>30 Arms|100 Arms<br>30 Arms| |Minimum operational current|150 mA|250 mA|500 mA|500 mA| |Rep. overload current t=1 s|55 Arms|125 Arms|200 Arms|200 Arms| |Non-repsurge current t=10ms|325 Ap|600 Ap|1900 Ap|1900 Ap| |Off-state leakage current|< 3 mA|< 3 mA|< 3 mA|< 3 mA| |I2t for fusing t=10 ms|< 525 A2s|< 1800 A2s|< 6600 A2s|< 18000 A2s| |Critical dV/dt off state min.|1000 V/μs|1000 V/μs|1000 V/μs|1000 V/μs| ## **In ut S ec i fi ca tions p p** ||**RM1E..AA..**|| |---|---|---| |**Current controlled input**||| |Control current range(A1-A2)|4-20 mADC|| |Pick upcurrent|4.2 mADC|| |Dropout current|4.1 mADC|| |Response time(input to output)≤ 20 ms|≤ 20 ms|| |Voltage drop|< 10 VDC @ 20 mA|| |Dynamic impedance|≥ 330 Ω|| |Max. allowable input current|50 mA|| |Reverse polarity protected|Yes|| ||**RM1E..V..**| |---|---| |**Voltage controlled input**|| |Supplyvoltage,Vss(A3-A2)|24 VDC ±20%| |Max. supply current|15 mA @ 19.2 VDC| ||20 mA @ 30 VDC| |Control voltage,Vcc(A1-A2)|0-10 VDC| |Pick upvoltage|0.2 VDC| |Dropout voltage|0.1 VDC| |Control input current|0.15 mA @10 VDC| |Response time(input to output)≤ 20 ms|≤ 20 ms| |Supply reverse protected|Yes| Note: The use of twisted pair cable for the control input is recommended ## **Out ut Power Dissi ation p p** **==> picture [440 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> 140<br>RM1E..125<br>120<br>RM1E..100<br>100<br>80<br>RM1E..50<br>60 RM1E.60..50<br>40<br>RM1E..25<br>20<br>0<br>0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125<br>Load current per pole in AACrms<br>Power dissipation in W<br>**----- End of picture text -----**<br> **2** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Electroma netic Com atibilit g p y** |**Immunity**|EN60947-4-3|**Radiated Radio Frequency**|| |---|---|---|---| |**Electrostatic Discharge (ESD)**<br>**Immunity**<br>Air discharge, 8 kV<br>Contact, 4 kV|IEC/EN 61000-4-2<br>Performance Criteria 2<br>Performance Criteria 2|**Immunity**<br>10 V/m, 80 - 1000 MHz<br>10 V/m, 1.4 - 2.0 GHz<br>3 V/m, 2.0 - 2.7 GHz<br>**Conducted Radio Frequency**|IEC/EN 61000-4-3<br>Performance Criteria 1<br>Performance Criteria 1<br>Performance Criteria 1| |**Electrical Fast Transient**||**Immunity**|IEC/EN 61000-4-6| |**(Burst) Immunity**|IEC/EN 61000-4-4|10 V/m, 0.15 - 80 MHz|Performance Criteria 1| |Output: 2 kV, 5 kHz|Performance Criteria 1|**Voltage Dips Immunity**|IEC/EN 61000-4-11| |Input: 1 kV, 5 kHz<br>**Electrical Surge Immunity**|Performance Criteria 1<br>IEC/EN 61000-4-5|0% for 0.5 , 1 cycle<br>40% for 10 cycles<br>70% for 25 cycles|Performance Criteria 2<br>Performance Criteria 2<br>Performance Criteria 2| |Output, line to line, 1 kV|Performance Criteria 2|80% for 250 cycles|Performance Criteria 2| |Output, line to earth, 1 kV|Performance Criteria 2|**Voltage Interruptions Immunity**|IEC/EN 61000-4-11| |Output, line to earth, 2 kV|Performance Criteria 2|0% for 5000 ms|Performance Criteria 2| ||with external varistor||| |Input, line to line, 1 kV|Performance Criteria 2||| |Input, line to earth, 2 kV|Performance Criteria 2||| ||||| |**EMC Emission**|EN60947-4-3|**Radio Interference**|| |**Radio Interference**||**Field Emission (Radiated)**|IEC/EN 55011| |**Voltage Emission (Conducted)**|IEC/EN 55011|**30 - 1000 MHz**|Class B| |**0.15 - 30 MHz**|Class A (industrial) with filters||| Notes: - Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indications, the filter attenuation will depend on the final application. - The manufacturer has set the maximum allowable deviation under the influence of RFI to +/- 1.0% FSD or +/-1 step in distributed modes. - Control input lines must be installed together to maintain products’ susceptibility to Radio Frequency interference. - Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended. - Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However, when the test is complete the product should return operating as intended by itself. - Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. **3** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Connection S ecifications p** |**Connection terminals**<br>Strippinglength(X)||**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~|**L1, T1**<br>12 mm<br>~~a~~||**A1, A2**<br>8 mm|**A1, A2**<br>8 mm|**A1, A2**<br>8 mm|**A1, A2**<br>8 mm|||||||**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~|**A1, A2, A3**<br>~~ai~~| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Connection Type||M5 screw with captivated washer|||||M5 screw with captivated washer<br>**RM1E..AA..:**|||||||||||||**RM1E..V..:**||||||| |||||||||||M3 screw with||||||||||M3 screw with<br>3 pins, pitch 2.54 mm||||||3 pins, pitch 2.54 mm| |||||||||||captivated||||||||captivated||square pin 0.64’||||||| |||||||||||washer||||||||||Accessory: RCS3-100-1||||||| |||||||||||||||||||||terminated cable||||||| |Rigid (solid & stranded)<br>UR rated data<br>X<br>1x 2.5 - 6.0 mm²<br>1x 14 - 10 AWG<br>ves||||||||||2x 2.5 - 6.0 mm²<br>2x 14 - 10 AWG<br>1x 0.5 - 2.5 mm~~²~~<br>1x 18 - 12 AWG||||||||||||||||| |Flexible with end sleeve<br>1x 1.0 - 4.0~~mm~~²<br>1x 1~~8 - 1~~2 AWG<br>2x 1.0 - 2.5 mm²<br>2x 2.5 - 4.0 mm²<br>2x 18 - 14 AWG<br>2x 14 - 12 AWG<br>1x 0.5 - 2.5 mm²<br>1x 18 - 12 AWG<br>Flexi~~ble~~without~~end~~<br>sleeve<br>1x 1.0 - 6.0 mm²<br>1x 18 - 10 AWG<br>2x 1.0 - 2.5 mm²<br>2x 2.5 - 6.0 mm²<br>2x 18 - 14 AWG<br>2x 14 - 10 AWG<br>Ce~~a~~||||||||||||||||||||||||||| |Torque specification||Pozidrive 2||||Pozidrive 2||||Pozidrive 1|||||||Pozidrive 1|||||||||| |||2.4 Nm (21.2 lb-in)||||||||0.5 Nm (4.4 lb-in)|||||0.5 Nm (4.4 lb-in)|||||||||||| |Aperture for termination<br>lug||12 mm||||||||7.5 mm||||||||||||||||| ## **Housin S ecifications g p** Weight 25 A, 50 A, Approx. 60 g 100 A, 125 A Approx. 100 g Housing material Noryl, black Baseplate 25 A, 50 A, Aluminium 100 A, 125 A Copper, nickel-plated Relay Mounting screws M5 Mounting torque 1.5-2.0 Nm ## **Functional Di a gram** **==> picture [199 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> A2(-) L1<br>IC IO<br>A1(+) T1<br>**----- End of picture text -----**<br> RM1E..AA.. **==> picture [227 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> (Brown) A3(+)<br>(Black) A2(-) L1<br>IC IO<br>(Blue) A1(+) T1<br>RM1E..V..<br>**----- End of picture text -----**<br> **4** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Thermal S ec i fi ca tions p** |Operatingtemperature|-20° to +70°C(-4˚ to +158 ˚F)| |---|---| |Storage temperature|-20° to +100°C(-4˚ to +212 ˚F)| |Junction temperature|≤125°C (257 ˚F)| ## **Isolation** |**Isolation**|| |---|---| |Rated isolation voltage|| |Input to output|≥ 4000 Vrms| |Output to case|≥ 4000 Vrms| ## **Heatsink Dimensions (load current versus ambient temperature)** With the output fully ON (360 ° conduction angle) ## **RM1E..25** ## **RM1E..50** |**RM1E..25**|||**RM1E..50**|**RM1E..50**|||| |---|---|---|---|---|---|---|---| |Load<br>Thermal resistance|||Load||Thermal resistance||| |current [A]<br>[°C/W]|||current [A]||[°C/W]||| |**25.0**<br>3.23<br>2.80<br>2.37<br>1.94<br>1.51<br>1.09<br>**22.5**<br>3.70<br>3.21<br>2.73<br>2.24<br>1.75<br>1.26<br>**20.0**<br>4.30<br>3.74<br>3.17<br>2.61<br>2.05<br>1.49<br>**17.5**<br>5.07<br>4.41<br>3.76<br>3.10<br>2.44<br>1.78<br>**15.0**<br>6.12<br>5.33<br>4.54<br>3.75<br>2.96<br>2.17<br>**12.5**<br>7.58<br>6.61<br>5.64<br>4.66<br>3.69<br>2.72<br>**10.0**<br>9.80<br>7.19<br>6.14<br>5.08<br>4.02<br>2.97<br>**7.5**<br>13.5<br>11.80<br>10.09<br>8.37<br>6.66<br>4.94<br>**5.0**<br>-<br>18.3<br>15.7<br>13.04<br>10.39<br>7.74<br>**2.5**<br>-<br>-<br>-<br>-<br>-<br>7<br>**20**<br>**30**<br>**40**<br>**50**<br>**60**<br>**70**<br>~~pot ft~~<br>~~pot~~<br>~~ft fT~~<br>~~pot~~<br>~~ft~~<br>~~fT TT~~<br>~~Pot ft~~<br>~~poof~~<br>~~ft fT~~<br>~~pot~~<br>~~ft fT~~<br>~~Pp of ff~~<br>~~po f~~<br>~~|~~<br>~~| TT~~<br>~~pot~~<br>~~fF fT~~<br>~~PF of of~~||TA|**50.0**<br>**45.0**<br>**40.0**<br>**35.0**<br>**30.0**<br>**25.0**<br>**20.0**<br>**15.0**<br>**10.0**<br>**5.0**|1.25<br>1.07<br>0.88<br>0.70<br>0.52<br>0.34<br>1.46<br>1.25<br>1.04<br>0.84<br>0.63<br>0.42<br>1.73<br>1.49<br>1.25<br>1.01<br>0.77<br>0.52<br>2.08<br>1.80<br>1.51<br>1.23<br>0.94<br>0.66<br>2.56<br>2.22<br>1.87<br>1.53<br>1.18<br>0.84<br>3.24<br>2.81<br>2.38<br>1.95<br>1.52<br>1.09<br>4.26<br>3.71<br>3.15<br>2.59<br>2.03<br>1.47<br>5.99<br>5.22<br>4.45<br>3.67<br>2.90<br>2.12<br>9.49<br>8.27<br>7.06<br>5.85<br>4.64<br>3.43<br>-<br>17.5<br>15.0<br>12.4<br>9.91<br>7.39<br>**20**<br>**30**<br>**40**<br>**50**<br>**60**<br>**70**<br>~~pot~~<br>~~ftfT~~<br>~~pot~~<br>~~ftfT~~<br>~~| of~~<br>~~ftfT~~<br>~~pot~~<br>~~ftfT~~<br>~~pf~~<br>~~fF~~<br>~~flTT~~<br>~~pot~~<br>~~fFfT~~<br>~~p of~~<br>~~ftfT~~<br>~~pot~~<br>~~fFfT~~<br>~~pot~~<br>~~fF~~<br>~~flTT~~<br>~~| of offT~~|||TA| |Ambient temp. [°C]|||||Ambient temp. [°C]||| |**RM1.60..50**|||||||| |Load<br>Thermal resistance|||||||| |current [A]<br>[°C/W]|||||||| |**50.0**<br>0.99<br>0.81<br>0.63<br>0.44<br>0.26<br>0.08<br>**45.0**<br>1.28<br>1.07<br>0.86<br>0.65<br>0.44<br>0.23<br>**40.0**<br>1.64<br>1.40<br>1.15<br>0.91<br>0.67<br>0.42<br>**35.0**<br>2.11<br>1.82<br>1.54<br>1.25<br>0.96<br>0.67<br>**30.0**<br>2.60<br>2.25<br>1.90<br>1.55<br>1.20<br>0.85<br>**25.0**<br>3.30<br>2.86<br>2.43<br>1.99<br>1.55<br>1.11<br>**20.0**<br>4.36<br>3.79<br>3.22<br>2.65<br>2.08<br>1.51<br>**15.0**<br>6.1<br>5.4<br>4.6<br>3.77<br>2.97<br>2.18<br>**10.0**<br>9.76<br>8.52<br>7.3<br>6.0<br>4.8<br>3.54<br>**5.0**<br>--<br>--<br>15.47<br>12.85<br>10.24<br>7.6<br>**20**<br>**30**<br>**40**<br>**50**<br>**60**<br>**70**<br>~~pot~~<br>~~ft~~<br>~~|TT~~<br>~~pot~~<br>~~fFfT~~<br>~~Pp of~~<br>~~tf~~<br>~~pof~~<br>~~|~~<br>~~|TT~~<br>~~Pp of~~<br>~~ff~~<br>~~|TT~~<br>~~Pp of ff~~<br>~~pot~~<br>~~ftfT~~<br>~~Pp of~~<br>~~|~~<br>~~|TT~~<br>~~poof~~~~**f**f~~<br>~~P| o~~<br>~~offT~~||TA|||||| |Ambient temp. [°C]|||||||| ## **RM1.60..50** **5** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Heatsink Dimensions (load current versus ambient temperature)** ## **RM1E..100** |**RM1E..100**||||||**RM1E..125**||||| |---|---|---|---|---|---|---|---|---|---|---| |Load|Thermal resistance|||||Load|Thermal resistance|||| |current [A]|[°C/W]|||||current [A]|[°C/W]|||| |**100.0**<br>0.60<br>0.52<br>0.43<br>**90.0**<br>0.74<br>0.64<br>0.54<br>**80.0**<br>0.91<br>0.79<br>0.68<br>**70.0**<br>1.09<br>0.96<br>0.82<br>**60.0**<br>1.33<br>1.16<br>1.00<br>**50.0**<br>1.66<br>1.45<br>1.24<br>**40.0**<br>2.16<br>1.89<br>1.62<br>**30.0**<br>3.01<br>2.64<br>2.26<br>**20.0**<br>4.73<br>4.14<br>3.55<br>**10.0**<br>9.94<br>8.70<br>7.45<br>**20**<br>**30**<br>**40**<br>~~of~~<br>~~ft~~<br>~~Ff~~<br>~~|~~<br>~~Pot~~<br>~~ft~~<br>~~P|~~<br>~~tf ~~<br>~~Pf~~<br>~~|~~<br>~~Pot~~<br>~~tT~~<br>~~P|~~<br>~~tf ~~<br>~~of~~<br>~~|~~<br>~~Pf~~<br>~~ft~~<br>~~|~~<br>~~|~~<br>~~tf~~||0.34<br>0.26<br>0.44<br>0.34<br>0.56<br>0.45<br>0.68<br>0.55<br>0.83<br>0.66<br>1.04<br>0.83<br>1.35<br>1.08<br>1.88<br>1.51<br>2.96<br>2.37<br>6.21<br>4.97<br>**50**<br>**60**<br>~~|~~<br>~~fl~~<br>~~|~~<br> ~~tt~~<br>~~|~~<br>~~|~~<br> ~~tt~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~ft~~||0.17<br>0.24<br>0.33<br>0.41<br>0.50<br>0.62<br>0.81<br>1.13<br>1.78<br>3.73<br>**70**|TA|**125.0**<br>0.63<br>0.55<br>**112.5**<br>0.73<br>0.64<br>**100.0**<br>0.84<br>0.74<br>**87.5**<br>0.99<br>0.87<br>**75.0**<br>1.20<br>1.05<br>**62.5**<br>1.48<br>1.30<br>**50.0**<br>1.92<br>1.68<br>**37.5**<br>2.65<br>2.32<br>**25.0**<br>4.12<br>3.60<br>**12.5**<br>8.55<br>7.48<br>**20**<br>**30**<br>~~Pot~~<br>~~P|~~<br>~~P|~~<br>~~P|~~<br>~~Pot~~<br>~~P|~~<br>~~P|~~<br>~~Pot~~<br>~~P|~~<br>~~Pot~~|0.47<br>0.54<br>0.63<br>0.74<br>0.90<br>1.11<br>1.44<br>1.98<br>3.09<br>6.41<br>**40**<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~tf ~~<br>~~tf~~|0.40<br>0.32<br>0.45<br>0.36<br>0.52<br>0.42<br>0.62<br>0.50<br>0.75<br>0.60<br>0.93<br>0.74<br>1.20<br>0.96<br>1.65<br>1.32<br>2.57<br>2.06<br>5.34<br>4.27<br>**50**<br>**60**<br>~~|~~<br>~~tl~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~tt~~<br>~~|~~<br> ~~tt~~<br>~~|~~<br>~~|~~|0.24<br>0.27<br>0.32<br>0.37<br>0.45<br>0.56<br>0.72<br>0.99<br>1.54<br>3.21<br>**70**|TA| |||Ambient temp. [°C]||||||Ambient temp. [°C]||| ## **Dimensions** **==> picture [493 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> 44.8 44.8<br>ai —— =|<br>12.3 12.3<br>2 x M5 2 x M5<br>LED LED<br>1.84<br>Pitch 2.54<br>2 x M3<br>EB eSAPPLY nee =APPLY<br>5.2 RM1E..AA 5.2 RM1E..V<br>All dimensions in mm All dimensions in mm<br>28.8 28.9 29.6<br>58.2 47.5 58.2 47.5<br>8.6<br>**----- End of picture text -----**<br> **6** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **A lications pp** **==> picture [236 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> RM1E..AA.. Iin A2 L1<br>(Ay © @ 0<br>4 to<br>20 mA Uline<br>‘ A1 @ @ T1 —<br>**----- End of picture text -----**<br> **==> picture [232 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> RM1E..V..<br>L1<br>@ —<br>(Black)(Blue) 0-10VDC0V A2 (GRD)A1 (Vcc) Uline<br>(Brown) +24VDC A3 (Vss)<br>rat) T1 oT<br>**----- End of picture text -----**<br> ## **Transfer Characteristics** Output power as a function of control output |**Control current**<br>**(mA)**|**Control voltage**<br>**(VDC)**|**Output power**| |---|---|---| |4<br>8<br>12<br>16<br>20|0<br>2.5<br>5<br>7.5<br>10|0<br>25<br>50<br>75<br>99| This relay is suitable for control of heaters, lighting and slightly inductive loads such as small fans. The relay can also be used for soft turn-on of high-power incandescent lamps. ## **Heatsink Selection** ## **Orderin Ke g y** ## **RHS..** - Heatsinks and fans - 5.40[o] C/W to 0.12[o] C/W thermal resistance - DIN, panel or thru wall mounting - Single or multiple SSR mounting Heatsink Range Overview: https://gavazziautomation.com/images/PIM/DATASHEET/ENG/SSR_Accessories.pdf ## Heatsink Selector Tool: https://www.gavazziautomation.com/en-global/products/solid-state-relays/heatsink-selector-tool **7** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Short Circuit Protection** Protection Co-ordination, Type 1 vs. Type 2: Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In type 2 co-ordination the device under test will still be functional after the short circuit. In both cases, however, the short circuit has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not be blown open. There shall be no damage to conductors of terminals and the conductors shall not separate from terminals. Therese shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is impaired. Discharge of parts or any risk of fire shall not occur. The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than 65,000 Arms Symmetrical Amperes, 600 Volts maximum when protected by fuses. Tests at 65,000 A were performed with Class J, fast acting: please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only. ## **Co-ordination Type 1 (UL508)** |**Part No.**|**Prospective short**|**Max. fuse size [A]**|**Class**|**Voltage [VAC]**| |---|---|---|---|---| ||**circuit current [kArms]**|||| |RM1E..25..|65|30|J / CC|600| |RM1E..50..|65|30|J|600| |||20|HSJ20(Mersen*)|600| |RM1E..100..|65|80|J|600| |||60|HSJ60(Mersen*)|600| |RM1E..125..|65|125|J|600| |||60|HSJ60 (Mersen*)|600| ## **Co-ordination Type 2 (IEC/EN60947-4-3)** |**Part No.**|**Prospective short**|**Max. fuse**|**Brand**|**Model**|**Size**| |---|---|---|---|---|---| ||**circuit current [kArms]**|**size [A]**|||| |RM1E.xx.25..(xx =23 or 48)|10|25|Mersen*|6.9gRB 10-25|10.3 x 38| |RM1E.60..25..|10|20|Mersen*|6.9gRB 10-20|10.3 x 38| |RM1E.xx.50..(xx = 23)|10|50|Mersen*|6.9zz CPgRC 14x51/50|14 x 51| |RM1E.xx.50..(xx = 48 or 60)|10|50|Mersen*|6.9zz CPgRC 22x58/50|22 x 58| |RM1E.xx.100..(xx = 23 or 48)|10|100|Mersen*|6.9zz CPgRC 22x58/100|22 x 58| |RM1E.60.100..|10|80|Mersen*|6.9zz CPgRC 22x58/80|22 x 58| |RM1E.xx.125.. (xx = 23 or 48)|10|125|Mersen*|6.921 CP URGD 27x60/125|27 x 60| zz = 00, without fuse trip indication zz = 21, with fuse trip indication * Formerly Ferraz Shawmut **8** Specifications are subject to change without notice (05.08.2025) ## **RM1E** ## **Type 2 Protection with Miniature Circuit Breakers (M.C.B.s)** |**Solid State Relay**|**ABB Model no. for**|**ABB Model no. for**|**Wire cross**|**Minimum length of**| |---|---|---|---|---| |**type**|**Z - type M. C. B.**|**B - type M. C. B.**|**sectional area [mm2] **|**Cu wire conductor [m]***| ||**(rated current)**|**(rated current)**||| |**RM1E..25..**|**1-pole**|||| ||S201-Z4 (4 A)|S201-B2 (2 A)|1.0|21.0| ||S201-Z6 UC (6 A)|S201-B2 (2 A)|1.0|21.0| ||||1.5|31.5| |**RM1E..50..**|**1-pole**|||| ||S201-Z10 (10 A)|S201-B4 (4 A)|1.0|7.6| ||||1.5|11.4| ||||2.5|19.0| ||S201-Z16 (16 A)|S201-B6 (6 A)|1.0|5.2| ||||1.5|7.8| ||||2.5|13.0| ||||4.0|20.8| ||S201-Z20 (20 A)|S201-B10 (10 A)|1.5|12.6| ||||2.5|21.0| ||S201-Z25 (25 A)|S201-B13 (13 A)|2.5|25.0| ||||4.0|40.0| ||**2-poles**|||| ||S202-Z25 (25 A)|S202-B13 (13 A)|2.5|19.0| ||||4.0|30.4| ||**1-pole**|||| |**RM1E..100..**||||| ||S201-Z20 (20 A)|S201-B10 (10 A)|1.5|4.2| ||||2.5|7.0| ||||4.0|11.2| ||S201-Z32 (32 A)|S201-B16 (16 A)|2.5|13.0| ||||4.0|20.8| ||||6.0|31.2| ||**2-poles**|||| ||S202-Z20 (20 A)|S202-B10 (10 A)|1.5|1.8| ||||2.5|3.0| ||||4.0|4.8| ||S202-Z32 (32 A)|S202-B16 (16 A)|2.5|5.0| ||||4.0|8.0| ||||6.0|12.0| ||||10.0|20.0| ||S202-Z50 (50 A)|S202-B25 (25 A)|4.0|14.8| ||||6.0|22.2| ||||10.0|37.0| |**RM1E..125..**|**1-pole**|||| ||S201-Z50 (50 A)|S201-B25 (25 A)|4.0|4.8| ||||6.0|7.2| ||||10.0|12.0| ||||16.0|19.2| ||S201-Z63 (63 A)|S201-B32 (32 A)|6.0|7.2| ||||10.0|12.0| ||||16.0|19.2| * Between MCB and Load (including return path which goes back to the mains). Note: A prospective current of 6 kA and a 230/400 V power supply system is assumed for the above suggested specifications. For cables with different cross section than those mentioned above please consult Carlo Gavazzi’s Technical Support Group. **9** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **Environmental Information** The declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/ T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products. Part Name Toxic or Harardous Substances and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium biphenyls (PBB) diphenyl ethers (Cr(Vl)) (PBDE) Power Unit Assembly x O O O O O O: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit requirement of GB/T 26572. X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. **环境特性** 这份申明根据中华人民共和国电子工业标准 SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质 零件名称 有毒或有害物质与元素 铅 汞 镉 六价铬 多溴化联苯 多溴联苯醚 (Pb) (Hg) (Cd) (Cr(Vl)) (PBB) (PBDE) 功率单元 x O O O O O O:此零件所有材料中含有的该有害物低于GB/T 26572的限定。 ~~[a]~~ X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。 ~~en~~ 25 re) **10** Specifications are subject to change without notice (05.08.2025) **RM1E** ## **FASTON Terminals** - Faston tabs - Tab dimensions according to DIN 46342 part 1 - Pure tin-plated brass ## **Orderin Ke g y** ## **Screw mounted Faston terminals RM1E48V25 F 4** RAM Solid State Relay Faston terminals Tab orientation Input Tab width: 4.8 mm Output Tab width: 6.3 mm **Faston terminals in packs of 20 RM48 F4** RS, RM Solid State Relay Tab orientation ~~ae~~ * 0: Flat (0º) 4: Angled (45º) ** 48: 4.8 mm faston for input 63: 6.3 mm faston for output ## **Fork Terminals** - Terminal adaptors for 35 mm[2] cable **Ordering Key RM635FK P** • Type RM635FK RM terminal adaptor - • Pack size: 10 pieces Touch protected (optional) ~~OO~~ - • Graphite thermal pad • Touch safety cover ## **Other Accessories** - Graphite thermal pad with adhesive on one side - Type RMIP20* - IP20 protection degree - Pack size: 20 pieces - Type KK071CUT - Dimensions: 35 x 43 x 0.25 mm - Cover not suitable with RM1E..V.. - Packing quantity: 50 pcs. All accessories can be ordered pre-assembled with Solid State Relays. Other accessories include DIN rail adaptors, fuses, varistors and spacers. For futher information refer to Accessories datasheets at: https://www.gavazziautomation.com/fileadmin/images/PIM/DATASHEET/ENG/SSR_Accessories.pdf **11** Specifications are subject to change without notice (05.08.2025)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →