Image not available
Illustrative purposes only
RLF100-11/12
Fan Blower, RLF100 Series, Flatpak, 12 VDC, DC, 127 mm, 25 mm, 37.7 CFM
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EBM-PAPST
- Product type: Blowers
- Blower Type:Flatpak; Supply Voltage:12V; Current Type:DC; Fan Frame Size:127mm; External Depth:25mm; Flow Rate - Metric:64m³/h; Flow Rate - Imperial:37.7cu.ft/min; Noise Rating:60dBA; Be
- IP Rating: -
- Blower Type: Flatpak
- Bearing Type: Ball Bearing
- Noise Rating: 60dBA
- Power Rating: 8W
- Voltage Type: DC
- Product Range: RLF100
- Air Flow - CFM: 37.7CFM
- External Depth: 25mm
- Fan Frame Size: 127mm
- Supply Voltage: 12VDC
- Air Flow - m3/min: 1.07m³/min
- Flow Rate - Metric: 64m³/h
- Flow Rate - Imperial: 37.7CFM
- Power Connection Type: 2 Lead Wires
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 60.73 € |
| Current stock | 25+ |
| Lead time | 30 days |
## Max. 80 m[3] /h ## DC centrifugal fans 127 x 25 mm **– Material:** Scroll housing: GRP[1)] Impeller: GRP[1) ] Base plate: Sheet steel **– Direction of air flow:** Axial: Intake, Centrifugal: Exhaust - **Connection:** via single wires AWG 22, TR 64 - **Highlights:** Optional protective cap for outlet opening Backward-curved impeller - **– Weight:** 320 g ## **– Possible special versions:** (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection - Degree of protection: IP 54 1) Fiberglass-reinforced plastic |~~**Type m**~~**3**~~**/h cfm VDC VDC Bel(A)**~~<br>~~RLF 100-11/12 64 37.7~~<br>Air flow<br>Air flow<br>Series RLF 100<br>**Nominal data**<br>~~——~~|~~**/h cfm VDC VDC Bel(A)**~~<br>~~RLF 100-11/12 64 37.7~~~~**12** 8...15 6.4~~<br>**Nominal voltage**<br>Voltage range|~~**/h cfm VDC VDC Bel(A)**~~<br>~~8...15 6.4~~<br>Sound power level|~~**/h cfm VDC VDC Bel(A)**~~<br>~~/~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Sintec sleeve bearings<br>Ball bearings|~~**/h cfm VDC VDC Bel(A)**~~<br>~~/~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Sintec sleeve bearings<br>Ball bearings|~~**/h cfm VDC VDC Bel(A)**~~<br>~~/~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Sintec sleeve bearings<br>Ball bearings|~~**Watts rpm**~~**-1 **~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Power consumption<br>Nominal speed|~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Temperature range|~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Service life L10 (40 °C)<br>ebm-papst standard<br>Service life L10 (Tmax)<br>ebm-papst standard|~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Life expectancyL10IPC<br>(40 °C) see page 17|~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~<br>Life expectancyL10IPC<br>(40 °C) see page 17|~~**°C Hours Hours**~~<br>~~8.0 5 100 -20...+75 80 000 / 30 000 135 000➀~~<br>Curve| |---|---|---|---|---|---|---|---|---|---|---|---| |~~RLF 100-11/14 64 37.7~~|~~RLF 100-11/14 64 37.7~~~~**24** 16...30 6.4~~|~~16...30 6.4~~|||~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.0 5 100 -20...+75 80 000 / 30 000 135 000➀~~| |~~RLF 100-11/18 64 37.7~~|~~RLF 100-11/18 64 37.7~~~~**48** 36...60 6.4~~|~~36...60 6.4~~|||~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000~~|~~8.6 5 100 -20...+75 80 000 / 30 000 135 000➀~~| ||||||||||||| |High speed models with open-collector tachometer and PWM speed control.|||||||||||| |~~RLF 100-11/12/2 HP-200 80 47.1~~|~~80 47.1~~~~**12** 10...13.2 7.5~~|~~10...13.2 7.5~~|||~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500~~|~~18.6 6 400 -20...+60 72 500 / 45 000 122 500➁~~| |~~RLF 100-11/18/2 HP-182 80 47.1~~|~~80 47.1~~~~**48** 43...53 7.5~~|~~43...53 7.5~~|||~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500~~|~~17.0 6 400 -20...+70 72 500 / 35 000 122 500➁~~| |Subject to change|||||||||||| Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see **==> picture [125 x 43] intentionally omitted <==** **----- Start of picture text -----**<br> i b) | '<br>Tin-plated<br>**----- End of picture text -----**<br> http://www.ebmpapst.com/general conditions **100**
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →