Image not available
Illustrative purposes only
RL90-18/00
Fan Blower, RL90AC Series, IP20, Flatpak, 115 VAC, AC, 121 mm, 37 mm, 24.7 CFM
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EBM-PAPST
- Product type: Blowers
- Blower Type:Flatpak; Supply Voltage:115V; Current Type:AC; Fan Frame Size:121mm; External Depth:37mm; Flow Rate - Metric:42m³/h; Flow Rate - Imperial:24.7cu.ft/min; Noise Rating:60dBA; Bearing Type:Sl
- SVHC: Lead (14-Jun-2023)
- IP Rating: IP20
- Blower Type: Flatpak
- Bearing Type: Sleeve Bearing
- Noise Rating: 60dBA
- Power Rating: 19.5W
- Voltage Type: AC
- Product Range: RL90AC
- Air Flow - CFM: 24.7CFM
- External Depth: 37mm
- Fan Frame Size: 121mm
- Supply Voltage: 115VAC
- Air Flow - m3/min: 0.7m³/min
- Flow Rate - Metric: 42m³/h
- Flow Rate - Imperial: 24.7CFM
- Power Connection Type: 2 Lead Wires
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 48.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Product Data Sheet 9214014005**
VHS0090XQHCS RL90-18/00
# **The engineer's choice** ebmpapst
**Product Data Sheet 9214014005** VHS0090XQHCS RL90-18/00
## **RL90-18/00**
|**INDEX**|**INDEX**||
|---|---|---|
|**1**|**General ............................................................................................................................................................... 3**||
|**2**|**Mechanics .......................................................................................................................................................... 3**||
||2.1|General......................................................................................................................................................... 3|
||2.2|Connections.................................................................................................................................................. 4|
|**3**|**Operating Data ................................................................................................................................................... 5**||
||3.1|Electrical Operating Data .............................................................................................................................. 5|
||3.2|Electrical Features ........................................................................................................................................ 6|
||3.3|Aerodynamics............................................................................................................................................... 6|
||3.4|Sound Data................................................................................................................................................... 7|
|**4**|**Environment....................................................................................................................................................... 7**||
||4.1|General......................................................................................................................................................... 7|
||4.2|Climatic Requirements.................................................................................................................................. 8|
|**5**|**Safety.................................................................................................................................................................. 8**||
||5.1|Electrical Safety............................................................................................................................................ 8|
||5.2|Approval Tests.............................................................................................................................................. 8|
|**6**|**Reliability............................................................................................................................................................ 8**||
||6.1|General......................................................................................................................................................... 9|
ebmpapst
09/12/2019
page 2 of 10
**Product Data Sheet**
**9214014005** VHS0090XQHCS RL90-18/00
## **1 General**
|Fantype|Blower|
|---|---|
|Rotating direction looking atrotor|Clockwise|
|Airflowdirection|Air inaxially,Airoutradially|
|Bearing system|Sleeve bearing|
|Mounting position -shaft|Any|
|Balancing grade|2,5|
## **2 Mechanics**
## **2.1 General**
|Width|121,0mm||
|---|---|---|
|Height|121,0mm||
|Depth|37,0mm||
|Diameter|0,0mm||
|Mass|0,680kg||
|Housingmaterial|Plastic||
|Impeller material|Plastic||
|Max. torque when mounted across both mounting<br>flanges<br>Screw size|Wire outlet corner: 280 Ncm<br>Remaining corners: 280 Ncm<br>ISO 4762 - M4 degreased, without an additional<br>brace andwithoutwasher||
ebmpapst
09/12/2019
page 3 of 10
**Product Data Sheet**
**9214014005** VHS0090XQHCS RL90-18/00
## **2.2 Connections**
|Electricalconnection|Wires||
|---|---|---|
|Lead wire length<br>Tolerance|L = 310,0 mm<br>+- 10,0 mm||
|Tube length<br>Tolerance|See drawing||
|Wire size (AWG)|20||
|Insulationdiameter|1,3mm||
|Plug|See drawing||
|Contact|See drawing||
||Color|Operation|
|---|---|---|
|1|black|L|
|2|black|N|
ebmpapst
09/12/2019
page 4 of 10
**Product Data Sheet**
**9214014005** VHS0090XQHCS RL90-18/00
## **3 Operating Data**
## **3.1 Electrical Operating Data**
Measurement Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up conditions: time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m.
∆ p = 0: corresp. to free air flow (see chapter aerodynamics) I: corresp. to RMS line current
|**Features**|**Condition**|**Symbol**|**Values**|**Values**|
|---|---|---|---|---|
|Frequency|∆p=0|f|50Hz|60Hz|
|Nominal voltage<br>Tolerance|∆p = 0|UN|115 V<br>+- 10 %|115 V<br>+- 10 %|
|Power consumption<br>Tolerance|∆p = 0|P|21 W<br>+5 %<br>- 10 %|21 W<br>+5 %<br>- 10 %|
|Speed<br>Tolerance|∆p = 0|n|2.450 1/min<br>+- 3 %|2.550 1/min<br>+- 3 %|
ebmpapst
09/12/2019
page 5 of 10
**Product Data Sheet**
**9214014005** VHS0090XQHCS RL90-18/00
**3.2 Electrical Features**
## Locked rotor protection Impedance Locked rotor current at ~~es~~
## **3.3 Aerodynamics**
Measurement Measured with a double chamber intake rig acc. to DIN EN ISO 5801. conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal.
The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions.
a.) Operation condition:
2.450 1/min at free air flow Frequency: 50 Hz
|Max. free-air flow(∆p=0 /|= max.)|35,0m3/h|
|---|---|---|
|Max.static pressure (∆p= m|= max./<br>=0)|90Pa|
b.) Operation condition: 2.550 1/min at free air flow Frequency: 60 Hz
|Max. free-air flow(∆p=0 /|= max.)|37,0m3/h|
|---|---|---|
|Max.static pressure (∆p= m|= max./<br>=0)|130Pa|
ebmpapst
09/12/2019
page 6 of 10
**Product Data Sheet 9214014005** VHS0090XQHCS RL90-18/00 ~~rr~~
**3.4 Sound Data**
Measurement Sound pressure level: 1 meter distance between microphone and the air intake. conditions: Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics.
a.) Operation condition: 2.450 1/min at free air flow Frequency: 50 Hz Optimal operating point 6,0 m3/h @ 76 Pa Sound power level at the optimal operating 5,4 bel(A) point Sound pressure level at free air flow, measured in rubber bands ~~—<———<<e~~ b.) Operation condition: 2.550 1/min at free air flow Frequency: 60 Hz Optimal operating point 9,0 m3/h @ 107 Pa Sound power level at the optimal operating 5,8 bel(A) point Sound pressure level at free air flow, measured in rubber bands ~~es~~ **4 Environment**
**4.1 General** -10 °C / 50 Hz Min. permitted ambient temperature TU min. -10 °C / 60 Hz 50 °C / 50 Hz Max. permitted ambient temperature TU max. 60 °C / 60 Hz Min. permitted storage temperature TL min. -40 °C ~~SSS~~ Max. permitted storage temperature TL max. 80 °C
09/12/2019
page 7 of 10
**Product Data Sheet 9214014005** VHS0090XQHCS RL90-18/00 ~~rr~~
**Climatic Requirements**
**4.2**
Humidity requirements humid heat, constant; according to DIN EN 60068-278, 14 days Water exposure None Dust requirements None ~~es~~ Salt fog requirements None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
## **5 Safety**
## **5.1 Electrical Safety**
|Dielectric strength<br>DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE<br>0700)<br>A.) Type test<br>Measuring conditions: After 48h of storage at 95%<br>R.H. and 25°C.<br>No arcing or breakdown is allowed!<br>All connections together to ground.<br>B.) Routine test<br>Measuring conditions: At indoor climate.<br>No arcing or breakdown is allowed!<br>All connections together toground.|1000 VAC / 1 Min.<br>1500 VAC / 1 Sec.|
|---|---|
|Isolation resistance<br>Measuring conditions: After 48h of storage at 95%<br>R.H. and 25°C measured with U=500 VDC for 1 min.|RI > 50 MOhm|
|Clearance / creepage distance|2,0 mm / 1,1 mm|
|Protection class|I|
**5.2 Approval Tests** CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans E38324 Association for Electrical, Electronic and Yes / Approval acc. to EN 60950 (VDE 0805) - Information VDE Information Technologies technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators ~~S~~ CCC China Compulsory Certification Yes ~~e~~ / GB 12350 Safety Requirements for small Power Motors The approval tests are observed to: U approval max.: 115 V / f: 60 Hz @ TU approval max.: 75 °C
## **6 Reliability**
09/12/2019
page 8 of 10
**Product Data Sheet**
**9214014005** VHS0090XQHCS RL90-18/00
|**6.1**|**6.1**|**General**|**General**|||||
|---|---|---|---|---|---|---|---|
||Life expectancy L10 at TU = 40 °C|Life expectancy L10 at TU = 40 °C|Life expectancy L10 at TU = 40 °C|Life expectancy L10 at TU = 40 °C|Life expectancy L10 at TU = 40 °C|Life expectancy L10 at TU = 40 °C|37.500 h / 50 Hz<br>37.500 h / 60 Hz|
||Life expectancy L10 at TU max.|Life expectancy L10 at TU max.|Life expectancy L10 at TU max.|Life expectancy L10 at TU max.|Life expectancy L10 at TU max.|Life expectancy L10 at TU max.|30.000 h / 50 Hz<br>25.000 h / 60 Hz|
ebmpapst
09/12/2019
page 9 of 10
**==> picture [507 x 721] intentionally omitted <==**
**----- Start of picture text -----**<br>
2a<br>a ~<br>= ao<br>.Cc<br>ca<br>N<br>S<br>% Y w-<br>wee Y<br>COR WIL<br>A<br>nN aX ia a<br>\ AA. _z =3 2[8<br>f(}lS<br>! ] == mo<br>s © Ss5 “a Be5aF<br>.— © Ci) _ mn2|S & Sobofeu<br>: = - =l_ a ro<br>[== So ala<br>* /[f 2 Q) x $ wi Z<br>> ! y; 3 — SE Sls<br>== PSZS O- At OF4e‘ay a || 3© 2£ Bza aeale<br>‘\\ 2 wv<br>a 2 g Als<br>S GK - 8 oe5 a2i= s<br>N = Sia ula<br>JIA E £35 13<br>Vv = a BR 25<br><o 2S sre&§ 22 | ==<br>=<br>/ s E_IL// [Bes<br>pF fy h j t-G>}<br>ee Oe S y || \ WDSC y<br>3<br>GN<br>OF 8'401<br><— KYD<br>EIN<br><x LSLTL7/LTS/LY7XY<br>SKSASSIILTS<br>Sg Or<br>Oe a<br>~ CY A<br>—_<br>= Ss<br>— ~~<br>a=ESPsOo . aa3<br>EZ Eoo C07 Q<br>o_-S-<br>Sze<br>WY Sin€ v0F 7°19<br>Hia :SD, zo—<br>5S Ne<br>‘ubisap Jo japow Aynyn e Jo UolyeJysiBad ayy Jo yuayed e Jo yueJB ayy Jo JuaAa ay UI =<br>paasasadaJe Syybls yy “sabewepjo yuawAed ayy oJ ayger) ave sJapuasjg ‘AylJoyjne ssasdxa ynoyy!M UAppIqJo) Wa{U2ERqYE Nid Yeu YseuLIBAZ {NYS SLeAnse<br>Ue ‘Joasay) S4Ua{UG) BYj Jo UO!Je>1UNWWO3 Jo asN ayy PUE SJayjo of 41 BuIAlb pue ‘yuauNd0p siyy yo HuIAdo} SN<br>-<br>r<br>**----- End of picture text -----**<br>
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →