Image not available
Illustrative purposes only
RJ1P48MBT50ECS
SSR-INDUSTRIAL MT. SSR H-S 480V 50A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (07-Nov-2024)
- Product Range: RJ1P Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 518.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Orderingg Keyy RJ 1 P 23 MBT 50 E BC** ## **Solid State Relays** _**SOLITRON MIDI**_ **Modbus Communication Interface Type RJ1P MB** - **AC semiconductor contactor** - **MODBUS RTU interface over RS485** - **RJ45 sockets for easy installation** - **Dual sockets for daisy chaining** - **Multi-function – 4 selectable modes of operation: ON/OFF, Phase angle, Distributed full cycle, Burst firing** - **Operational ratings up to 50 AACrms and 600 VAC** - **Temperature monitoring with over-temperature protection** - **Opto isolation: > 4000 VACrms** - **LED status indication** **Product Descri tion p Orderingg Keyy** The RJ1P MB series is a solid the Modbus RTU communica- **Solid State Relay** state relay equipped with a tion protocol, operating over an **Number of poles** fieldbus communication interRS485 interface. **Switching mode (Proportional)** face. **Rated operational voltage** The communication interface **Control input type** The ~~I~~ relay operates under conallows modification and read- ~~T~~ **Rated operational current** trol of a microcontroller that ing of several parameters very **Terminal layout** handles communication, moniquickly through a single con- **Configuration options** tors operational parameters nection. Diagnostic information and controls the SSR thyristor is easily accessible for troufiring. The RJ1P MB supports bleshooting and repair. ## **T e Selection yp** |**Switching**|**Rated operational**|**Control**|**Rated operational**|**Terminal**|**Options**| |---|---|---|---|---|---| |**mode**|**voltage**|**input**|**current**|**layout**|| |P: Proportional|23: 230VACrms|MBT: 2-wire Modbus RTU|50: 50AACrms|E: Contactor|BC: Basic Controller| |Output|48: 480VACrms|||layout|CS: Current Sensing| ||60: 600VACrms||||CV: Current & Voltage| ||||||Sensing| ## **Selection Guide** |**Rated operational**|**Blocking voltage**|**Supply voltage**|**Control input**|**Rated operational**| |---|---|---|---|---| |**voltage**||||**current**| |230VACrms|650Vp|24VDC|RS485 interface (2-wire)|**RJ1P23MBT50EBC**| |||||**RJ1P23MBT50ECS**| |||||**RJ1P23MBT50ECV**| |480VACrms|1200Vp|24VDC|RS485 interface (2-wire)|**RJ1P48MBT50EBC**| |||||**RJ1P48MBT50ECS**| |||||**RJ1P48MBT50ECV**| |600VACrms|1200Vp|24VDC|RS485 interface (2-wire)|**RJ1P60MBT50EBC**| |||||**RJ1P60MBT50ECS**| |||||**RJ1P60MBT50ECV**| ## **Thermal S ecifications p** |Operating temperature|-30 to +70ºC(-22 to +158 ˚F)| |---|---| |Storage temperature|-40to+100ºC(-40to+212˚F)| ## **Isolation** Rated isolation voltage Input to output ≥ 4000 VACrms Output to case ≥ 4000 VACrms **1** Specifications are subject to change without notice (04.11.2008) **RJ1P MB** ## **General S ecifications p** |Operational voltage range|| |---|---| |RJ1P23|90-265VAC| |RJ1P48|200-500VAC| |RJ1P60|410-660VAC| |Blocking Voltage|| |RJ1P23|650Vp| |RJ1P48|1200Vp| |RJ1P60|1200Vp| |Power Factor|| |RJ1P23|>0.9 @ 230VACrms| |RJ1P48|>0.9 @ 480VACrms| |RJ1P60<br>Operational frequency range<br>Output indication|>0.9 @ 600VACrms<br>45-65 Hz<br>Green LED (dual intensity)| |Alarm indication|Red LED| ## **Housin S ecifications g p** |Weight<br>Housing material|Approx. 415 g<br>PBT| |---|---| |Control terminal cable size|| |Min<br>Max<br>Mounting torque max.<br>Control terminal screw|1 x 0.5 mm2 (1 x AWG20)<br>1 x 4.0 mm2 (1 x AWG12) or<br>2 x 2.5 mm2 (2 x AWG14)<br>1 Nm Posidriv 0 bit<br>M3| |Power terminal cable size<br>Min<br>Max<br>Mounting torque max.<br>Power terminal screw|1 x 4 mm2 (1 x AWG12)<br>1 x 25 mm2 (1 x AWG3) or<br>2 x 10 mm2 (2 x AWG6)<br>2.4 Nm Posidriv 2 bit<br>M5| |Data Connection|Shielded RJ45| ## **Data S ecification p** |**Data Specification**||| |---|---|---| |Interface<br>Bus Loading|RS485<br>1/8 unit load|| |Communication protocol<br>Data line ESD voltage withstand|Modbus RTU<br>15KV HBM|| |Parity|Selectable - None,|| |Data Rate|Odd, Even<br>9600, 19200, 38400,|57600,| ||115200 baud|| |Devices on Bus|247|| |Address configuration|DIP-SWITCH|| |Data indication|Orange LED, flashing| |---|---| |SSR fault detection|Yes| |Over temperature protection|Yes| |Output power|0 – 99.6%| |Output power resolution|| |Mode 0 ON/ OFF|1/1| |Mode 1 Phase angle|1/256| |Mode 2 Full cycle|1/256| |Mode 3 Burst firing|1/32 – 1/256 depending| ||on time-base setting| |Pollution degree|2| |Installation category|III| |Approvals|UL, cUL| |CE-marking|Yes| ## **Out ut S ecifications p p** |Rated operational current<br>AC51<br>@Ta=25ºC|50AACrms| |---|---| |Min. operational current|500mAACrms| |Rep. overload current t=1 s|| |(Tj init.=25°C)|< 200AACrms| |Non-rep. surge current t=10 ms|| |(Tj init.=25°C)|1900Ap| |Off-state leakage current,|| |@ rated voltage and frequency|< 3 mArms| |I2t for fusing t=10 ms|18000A2s| |Max. On-state voltage drop @|| |rated current|1.6Vrms| |Critical dV/dt off-state|1000V/µs| ## **Su l S ecifications pp y p** |Supply voltage range|| |---|---| |(according to EN 61131-2)|19.2 - 30 VDC| |Supply current|| |@ 19.2 VDC|13mA| |@ 30 VDC|10mA| |Supply status indication|Green LED, half intensity| **2** Specifications are subject to change without notice (30.03.2007) **RJ1P MB** ## **Functional Diagram** ## **Alarms and Features** |**BC - Basic Controller**|• **Internal temperature **|**measurement from -32 to +128˚C**| |---|---|---| ||• **Power control by:**|| ||On/Off|Mode 0| ||Phase angle|Mode 1| ||Distributed firing|Mode 2| ||Burst firing|Mode 3| ||• **Fault detection:**|Over-temperature (Fault is detected when internal| |||temperature exceeds the factory set limit and is| |||automatically cleared when temperature falls to the| |||safe level, provided that the output power level has| |||been set manually to 0), SSR fault (shorted, 1/2| |||wave conduction, open circuit), Phase Loss, Full| |||Load Loss| |**CS – Adds Current Sensing capability**|Same features as RJ1P23MBT50EBC with additional:|| ||**• Current monitoring**|| |**CV – Adds Current and**|Same features as RJ1P23MBT50ECS with additional:|| |**Voltage sensing capability**|• **Voltage monitoring**|| ||• **Power measurement**|| **3** Specifications are subject to change without notice (04.11.2008) **RJ1P MB** ## **LED indication** The Green LED (Output) is a dual purpose indicator. When 24V power is applied the Green LED is dimly lit. When the output thyristors are activated, the Green LED is lit up more brightly in tandem with application of power to the load. The Yellow LED (Data) shows when there are communication communication activity. It errors or when the relay is lights up for the period of time operating abnormally. In the that the relay is involved in case of communication errors, communication over the the Alarm LED is reset by the RS485 bus. This applies for next valid communication seqboth transmission and recepuence. When there is abnortion. mal operation the Alarm LED The Red LED (Alarm) lights up resets when the operating con- ditions revert back to normal. All three LEDs flashing continuously indicate that the device is in configuration mode (Modbus address set to unsopported value). Details shown in product manual. ## **Deratin Curve g** ## **Dissipation Curve** **==> picture [215 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 50<br>50A<br>40<br>30<br>W<br>20<br>10<br>0<br>0 10 20 30 40 50 60<br>AACrms<br>**----- End of picture text -----**<br> **4** Specifications are subject to change without notice (30.03.2007) **RJ1P MB** ## **Connection Exam les p** **==> picture [470 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> RS485 from To other devices or<br>PLC/IPC terminating resistor<br>**----- End of picture text -----**<br> Notes: 1. A terminating resistor (value 100 Ω to 130 Ω ) must be fitted at each end of the RS485 network. 2. 24V power may be applied through terminals 6A4, 4A2 or through the RJ-45 connector. If daisy chaining several devices using standard ethernet patch leads, the connection to 6A4, 4A2 is optional for the second and successive devices. For large networks it is necessary to connect 6A4, 4A2 every 25th device. 3. Max. no of daisy chained devices may be limited by patch-lead conductor diameter and length. 4. Refer to product handbook for detailed installation instructions. ## **O eration p** **Mode 0 – ON/OFF control** In Mode 0 the relay operates as a standard ON/OFF relay with zero switching. In this mode the relay can deliver either 0% or 100% power. This mode is ideal for systems where the process controller employs a digital process variable, similar to that used in standard solid state relay applications. **Mode 1 – Phase angle control Mode 2 – Distributed firing** In Mode 1 the load power is In Mode 2 full cycles are adjusted by delaying the thyrisswitched ON/OFF over a peritor switching signal according od of 256 mains cycles. The to the required power. The number of cycles that are resulting output is a chopped switched ON corresponds to sine-wave. The relay switches the value specified in the load itself off every half cycle. power register. This mode Timings are calculated such uses an algorithm that distribthat a linear power response utes the ON cycles evenly over curve is obtained. This mode the 256 cycle period. is suited for loads where continuous control of power is required. **Mode 3 – Burst firing** In Mode 3 full cycles are switched ON/OFF over a period of mains cycles as defined by the Time-Base Register. Mode 3 uses an algorithm that will switch ON a number of cycles in a continuous burst for a time period corresponding to the required power. **5** Specifications are subject to change without notice (04.11.2008) **RJ1P MB** ## **Dimensions** ## **Terminal Layout** **==> picture [80 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> CARLO GAVAZZI<br>RJ1P23MBT50EBC<br>AC51: 50A, 230V~<br>**----- End of picture text -----**<br> All dimensions in mm Note: Terminals 5N/L2 and 3N/L2 are available only on RJ1P23MBT50ECV **6** Specifications are subject to change without notice (04.11.2008)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →