RIA452-A212A11A
Process Indicator, 7 Digit, Current, -20 to 60°C, 20 to 28VAC, 4 x SPDT, 1Analogue, RIA452 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ENDRESS+HAUSER
- Product type: Digital Panel Meters
- SVHC: No SVHC (27-Jun-2024)
- Meter Range: 0mA to 20mA, 4mA to 20mA, 0mA to 5mA
- Digit Height: -
- Product Range: RIA452 Series
- Meter Function: Current
- Panel Cutout Width: 92mm
- Supply Voltage Max: 0
- Supply Voltage Min: 20VAC
- Panel Cutout Height: 92mm
- No. of Digits / Alpha: 7
- Operating Temperature Max: 60°C
- Operating Temperature Min: -20°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 432.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Technical Information ## Prosonic T FMU30 ## Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials ## **Application** - Continuous, non-contact level measurement in fluids, pastes, sullages and coarse bulk materials - System integration via 4 to 20mA - Maximum measuring range: - 1½" sensor: 5 m (16 ft) in fluids 2 m (6 ft) in bulk materials - 2" sensor: 8 m (26 ft) in fluids - 3.5 m (11 ft) in bulk materials ## **Features and benefits** - Quick and simple commissioning via menu-guided onsite operation with four-line plain text display; 7 languages selectable - Envelope curves on the on-site display for simple diagnosis - Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate - Non-contact measurement method minimizes service requirements - Installation possible from thread G 1½“ or NPT 1½“ upwards - Integrated temperature sensor for automatic correction of the temperature dependent sound velocity TI00440F/00/EN/15.14 71225633 Prosonic T FMU30 ## **Table of contents** **Function and system design. . . . . . . . . . . . . . . . . . . . . 3** Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 **Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5** Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 **Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6** Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Output damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 **Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7** Terminal compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ## **Performance characteristics. . . . . . . . . . . . . . . . . . . . . 8** Reaction time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Measured value resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Pulse frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Maximum measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Typical measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Influence of the vapor pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Housing design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Process connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 **Operability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16** Display and operating elements . . . . . . . . . . . . . . . . . . . . . . . . . 16 On-site operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 **Certificates and Approvals. . . . . . . . . . . . . . . . . . . . . 20** CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ex approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 External standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . 20 **Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 21** FMU30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 **Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22** Installation bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Screw in flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Cantilever with mounting frame or wall bracket . . . . . . . . . . . . . 24 Weather protection cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Commubox FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 ToF Adapter FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 **Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27** Operating manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Description of device functions . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Short instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 **Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9** Installation variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installation conditions for level measurements . . . . . . . . . . . . . . 10 Installation in narrow shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation conditions for flow measurements . . . . . . . . . . . . . . . 11 Blocking distance, nozzle installation . . . . . . . . . . . . . . . . . . . . . 12 ## **Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13** Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Resistance to alternating temperature cycles . . . . . . . . . . . . . . . . 13 Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . 13 **Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13** Process temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Process pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 **Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 14** Design; dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Endress+Hauser 2 Prosonic T FMU30 ## **Function and system design** ## **Measuring principle** **==> picture [386 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> BD 20mA<br>100%<br>D<br>E<br>F<br>L<br>4mA<br>0%<br>L00-FMU30-15-00-00-xx-001<br>BD Blocking distance D Distance from sensor membrane - product surface<br>E Empty distance F Span (full distance)<br>L Level<br>**----- End of picture text -----**<br> |**Sensor**|**BD**|**Max. range fluids**|**Max. range bulk materials**| |---|---|---|---| |1½"|0.25 m (0.8 ft)|5 m (16 ft)|2 m (6.6 ft)| |2"|0.35 m (1.1 ft)|8 m (26 ft)|3.5 m (11 ft)| ## **Time-of-flight method** The sensor of the instrument transmits ultrasonic pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The instrument measures the time t between pulse transmission and reception. The instrument uses the time t (and the velocity of sound c) to calculate the distance D between the sensor membrane and the product surface: D = c t/2 As the device knows the empty distance E from a user entry, it can calculate the level as follows: L = E - D An integrated temperature sensor (NTC) compensates for changes in the velocity of sound caused by temperature changes. ## **Interference echo suppression** The interference echo suppression feature on the instrument ensures that interference echos (e.g. from edges, welded joints and installations) are not interpreted as a level echo. ## **Calibration** Enter the empty distance E and the span F to calibrate the device. ## **Blocking distance** Span F may not extend into the blocking distance BD. Level echos within the blocking distance cannot be evaluated due to the transient characteristics of the sensor. 3 Endress+Hauser Prosonic T FMU30 ## **Equipment architecture** The complete measuring system consists of: **==> picture [272 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>A Ul [[aL] 2<br>WES =<br>3<br>% E 4<br>6<br>ENDRESS + HAUSERRMA 422<br>= a 7NK. 5<br>**----- End of picture text -----**<br> **==> picture [56 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> L00-FMU30xxx-14-00-06-xx-008<br>**----- End of picture text -----**<br> - _1 PLC (programmable logic controller)_ - _2 Computer with operating tool (e.g. FieldCare)_ - _3 Commubox FXA291 and ToF Adapter FXA291 4 Operating and display module 5 Prosonic FMU30 6 Transmitter power supply unit RMA42 or RN221N_ ## **On-site operation** - With display and operating module - With a PC, Commubox FXA291 + ToF Adapter FXA291 and the operating software FieldCare 4 Endress+Hauser Prosonic T FMU30 ## **Input** **Measured variable** The distance D between the sensor membrane and the product surface is measured, see also figure ä 3. Using the linearization function, the device uses D to calculate: • Level L in any units • Volume V in any units • Flow Q across measuring weirs or open channels in any units **Measuring range** The measuring range is limited by the range of a sensor. The sensor range is, in turn, dependent on the operating conditions. To estimate the actual range, proceed as follows (see also the calculation example in the diagram): 1. Determine which of the influences shown in the following table are appropriate for your process. 2. Add the corresponding attenuation values. 3. From the total attenuation, use the diagram to calculate the range. |**Fluid surface**|**Attenuation**| |---|---| |Calm|0 dB| |Waves|5 to 10 dB| |Strong turbulence (e.g. stirrers)|10 to 20 dB| |Foaming|Please contact your Endress+Hauser sales representative.| ||| |**Bulk material surface**|**Attenuation**| |Hard, rough (e.g. rubble)|40 dB| |Soft (e.g. peat, dust-covered clinker)|40 to 60 dB| |**Dust**|**Attenuation**| |---|---| |No dust formation|0 dB| |Little dust formation|5 dB| |Heavy dust formation|5 to 20 dB| ||| |**Filling curtain in detection range**|**Attenuation**| |None|0 dB| |Small quantities|5 to 10 dB| |Large quantities|10 to 40 dB| ||| |**Temperature difference between**<br>**sensor and product surface**|**Attenuation**| |to 20 °C (68 °F)|0 dB| |to 40 °C (104 °F)|5 to 10 dB| |to 60 °C (140 °F)|10 to 15 dB| Endress+Hauser 5 Prosonic T FMU30 **==> picture [386 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> R [m]<br>10<br>1<br>2<br>5<br>1<br>A [dB]<br>10 20 30 40 50 60 70 80<br>L00-FMU3xxxx-05-00-00-xx-100<br>**----- End of picture text -----**<br> _1 Sensor 2"_ - _2 Sensor 1½" A Attenuation (dB) R Range (m)_ ## **Example** - Strong turbulence surface approx. 50 dB - • No dust formation 0 dB • Filling curtain in detection range 10 dB - • Temperature diff. < 20 °C (68 °F) 0 dB approx. 50 dB range approx. 3.5 m (11 ft) for FMU30 2" sensor These measuring conditions have been taken into account during the calculation of the maximum measuring range in solid applications. ## **Operating frequency** |**1½" sensor**|**2" sensor**| |---|---| |approx. 70 kHz|approx. 50 kHz| ## **Output** ||**Output signal**|4 to 20 mA| |---|---|---| |**Signal on alarm**||Error information can be accessed via the following interfaces:| |||• On-site display (error symbol, error code and plain text description)| |||• Current output, signal on error can be selected (e.g. according to NAMUR recommendation NE43)| |**Output damping**||Freely selectable, 0 to 255 s| |**Linearization**||The linearization function of the instrument allows conversion of the measured value into any unit of length| |||or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow| |||from the measured level).| The linearization table for calculating the volume in an horizontal cylindrical tank is preprogrammed. You can also enter any number of other tables containing up to 32 value pairs either manually or semi-automatically (by filling the vessel under controlled conditions). 6 Endress+Hauser Prosonic T FMU30 ## **Power supply** **Terminal compartment** The terminals are located underneath the housing cover. **==> picture [517 x 455] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>Display<br>3<br>4<br>L00-FMU30xxx-04-00-00-xx-001<br>1 Terminals<br>2 Optional: display<br>3 Internal earth terminal<br>4 External earth terminal<br>Terminal assignment<br>1<br>T 0.5A<br>2<br>4<br>3<br>1 2 3<br>L- L+<br>L00-FMU30xxx-04-00-00-de-015<br>1 Power<br>2 Fuse as per IEC 60127, T 0.5 A<br>3 Plant ground<br>3 4...20 mA<br>1 2<br>**----- End of picture text -----**<br> - Connect the connecting line to the screw terminals (line cross-sections of 0.25 to 2.5mm[] (24...14 AWG)) in the terminal compartment. - A standard installation cable is sufficient for the connection. - Protective circuitry against reverse polarity, RFI and over-voltage peaks is built into the device (see also Technical Information TI00241F/00/EN "EMC Test Procedures") Endress+Hauser 7 Prosonic T FMU30 ||**Supply voltage**|14-35 V| |---|---|---| |**Terminals**||Cable cross-section: 0.25 to 2.5 mm2 (24 to 14 AWG)| |**Cable entry**||G ½" or ½" NPT| |**Cable gland**||M20x1.5 (recommended cable diameter 6 to 10 mm (0.24 to 0.39 in))| |**Power consumption**||51 mW to 800 mW| |**Current consumption**||3.6 to 22 mA| ## **Performance characteristics** ||**Reaction time**|The reaction time depends on the parameter settings. The minimum value is: min. 2 s| |---|---|---| |**Reference operating**||• Temperature = +20 °C (+68 °F)| |**conditions**||• Pressure = 1013 mbar abs. (15 psi abs.)| |||• Humidity = 50 %| |||• Ideal reflective surface (e.g. calm, smooth fluid surface)| |||• No interference reflections within signal beam| |||• Set application parameters:| |||– Tank shape = dome ceiling| |||– Medium property = liquid| |||– process conditions = standard liquid| ||**Measured value resolution**|1 mm (0.04 in)| ||**Pulse frequency**|max. 0.5Hz| |||The exact values are dependent on the type of device and the parameter settings.| ||**Maximum measuring error1) 2)**|±0.2 % of the maximum span of the sensor| |**Typical measuring error**||Include linearity, repeatability, and hysteresis| |||Better than: ±3 mm (±0.12 in) or 0.2 % of measuring distance*| |||* whichever is greater| |**Influence of the vapor**||The vapor pressure at 20 °C (68 °F) gives a hint on the accuracy of the ultrasonic level measurement. If the| |**pressure**||vapor pressure at 20 °C (68 °F) is below 50 mbar (1 psi), ultrasonic level measurement is possible with a very| |||high accuracy. This is valid for water, aqueous solutions, water-solid-solutions, dilute acids (hydrochloric acid,| |||sulfuric acid, ...), dilute bases (caustic soda, ...), oils, greases, slurries, pastes, ...| |||High vapor pressures or outgassing media (ethanol, acetone, ammonia, ...) can influence the accuracy. If| |||conditions like these are present, please contact your Endress+Hauser sales representative.| > 2) with reference operating conditions 1) according to EN 61298-2 8 Endress+Hauser Prosonic T FMU30 ## **Installation** ## **Installation variants** **==> picture [289 x 278] intentionally omitted <==** **----- Start of picture text -----**<br> A B<br>|a!<j J |on!<i |an!< yl e 1<br>imml Imm! TI/<br>1 n s lo o e VFWxL __ | — |<br>C D<br>7 [I]<br>/ 4 ) he 1<br>Aon go \ WII on<br>3 ai et 2<br>**----- End of picture text -----**<br> **==> picture [56 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> L00-FMU30xxx-17-00-00-xx-002<br>**----- End of picture text -----**<br> - **A** _Installation with counter nut_ - _1 counter nut (PC) supplied for G1½ and G2 instruments_ - **B** _Installation with sleeve_ - _1 sealing (EPDM) supplied_ - **C** _Installation with installation bracket_ - **D** _Installation with screw in flange_ - _1 sealing (EPDM) supplied_ - _2 nozzle_ - _3 sensor_ - _4 screw in flange_ For installation bracket or screw in flange ä 22, "Accessories". 9 Endress+Hauser Prosonic T FMU30 ## **Installation conditions for level measurements** **==> picture [386 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> 2 3 4<br>1 5<br>1/6D<br>D<br>a 6 L<br>r<br>rl<br>L00-FMU30xxx-17-00-00-xx-005<br>• Do not install the sensor in the middle of the tank (3). We recommend leaving a distance between the sensor<br>and the tank wall (1) measuring 1/6 of the tank diameter.<br>**----- End of picture text -----**<br> - Protect the device against direct sun or rain (2) ä 26 "Weather protection cover". - Avoid measurements through the filling curtain (4). - For solid application where bulk solid cones appear, align the sensor membrane perpendicular to the surface. - Make sure that equipment (5) such as limit switches, temperature sensors, etc. are not located within the emitting angle . In particular, symmetrical equipment (6) such as heating coils, baffles etc. can influence measurement. - Never install two ultrasonic measuring devices in a tank, as the two signals may affect each other. • To estimate the detection range, use the 3 dB emitting angle . ## **Installation in narrow shafts** **Sensor** **Lmax rmax** 1½" 11° 5 m (16 ft) 0.48 m (1.6 ft) 2" 11° 8 m (26 ft) 0.77 m (2.5 ft) ~~————~~ In narrow shafts with strong interference echoes, we recommend using an ultrasound guide pipe (e.g. PE or PVC wastewater pipe) with a minimum diameter of 100 mm (3.94 in). 1 **==> picture [188 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>L00-FMU30xxx-17-00-00-xx-010<br>1 Venting hole<br>**----- End of picture text -----**<br> Make sure that the pipe is not soiled by accumulated dirt. If necessary, clean the pipe at regular intervals. 10 Endress+Hauser Prosonic T FMU30 **Installation conditions for flow measurements** - Install the instrument at the inflow side (B), as close above the maximum water level Hmax as possible (take into account the blocking distance BD). - Position the instrument in the middle of the channel or weir. - Align the sensor membrane parallel to the water surface. - Keep to the installation distance of the channel or weir. ## **Example: Khafagi-Venturi flume** **==> picture [386 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> B C<br>BD<br>E<br>Hmax =F V<br>A<br>_ |} Es<br>1 x b0<br>b0<br>( =a<br>A0019607<br>A Khafagi-Venturi flume BD Blocking distance<br>B Inflow E Empty calibration<br>C Outflow F Full calibration<br>V Direction of flow<br>**----- End of picture text -----**<br> **Example: Triangular weir** **==> picture [307 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> min. 2 Hmax.<br>Hmax.(= F)<br>min. 2 Hmax.<br>Ls<br>min. 3 Hmax.<br>BD<br>E<br>**----- End of picture text -----**<br> **==> picture [56 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> L00-FMU30xxx-17-00-00-xx-012<br>**----- End of picture text -----**<br> **==> picture [70 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> BD Blocking distance<br>E Empty calibration<br>F Full calibration<br>**----- End of picture text -----**<br> 11 Endress+Hauser Prosonic T FMU30 ## **Blocking distance, nozzle installation** Install the instrument at a height so that the blocking distance BD is not undershot, even at maximum fill level. Use a pipe nozzle if you cannot maintain the blocking distance in any other way. The interior of the nozzle must be smooth and may not contain any edges or welded joints. In particular, there should be no burr on the inside of the tank side nozzle end. Note the specified limits for nozzle diameter and length. To minimise disturbing factors, we recommend an angled socket edge (ideally 45°). **==> picture [176 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> BD ' _ F .<br>SD<br>gt<br>E PT<br>a fg<br>F<br>L Y)Y)LLIYJHHH }iY]qHq H<br>HYY el D ]q<br>**----- End of picture text -----**<br> **==> picture [56 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> L00-FMU30xxx-17-00-00-xx-004<br>**----- End of picture text -----**<br> _BD Blocking distance F Full calibration (span) SD Safety distance D Nozzle diameter E Empty calibration L Nozzle length_ ||**Maximum nozzle length mm (in)**|**Maximum nozzle length mm (in)**| |---|---|---| |**Nozzle diameter**|**1½" sensor**|**2" sensor**| |DN50/2"|80 (3.15)|| |DN80/3"|240 (9.45)|240 (9.45)| |DN100/4"|300 (11.8)|300 (11.8)| |DN150/6"|400 (15.7)|400 (15.7)| |DN200/8"|400 (15.7)|400 (15.7)| |DN250/10"|400 (15.7)|400 (15.7)| |DN300/12"|400 (15.7)|400 (15.7)| |**Sensor characteristics**||| |Emitting angle|11°|11°| |Blocking distance (m [ft])|0.25 (0.8)|0.35 (1.1)| |Max. range (m [ft]) in liquids|5 (16)|8 (26)| |Max. range (m [ft]) in solids|2 (6.6)|3.5 (11)| ## Caution! If the blocking distance is undershot, it may cause device malfunction. ## Note! In order to notice if the level approaches the blocking distance, you can specify a safety distance (SD). If the level is within this safety distance, the instrument outputs a warning or alarm message. 12 Endress+Hauser Prosonic T FMU30 |||**Environment**| |---|---|---| |**Ambient temperature range**||20 °C to +60 °C (4 °F to +140 °F)| |||Use a protective cover, in order to protect the sensor from direct sun or rainä26, "Weather protection| |||cover".| |**Storage temperature**||40 °C to +80 °C (40 °F to +176 °F)| |**Resistance to alternating**||To DIN EN 60068-2-14; Nb test : +60°C/20°C (+140 °F/4 °F), 0.5K/min, 100cycles| |**temperature cycles**||| |**Climate class**||DIN EN 60068-2-38 (Test Z/AD) DIN/IEC 68 T2-30Db| |**Ingress protection**||• With closed housing, tested according to| |||– IP68, 24h at 1.83 m (6.0 ft) under water surface| |||– IP66| |||• With open housing: IP20 (also ingress protection of the display)| |**Vibration resistance**||DIN EN 60068-2-64 / IEC 68-2-64: 20 to 2000 Hz, 1 (m/s)2/Hz; 3 x 100 min| ||**Electromagnetic compatibility**|• Electromagnetic compatibility to EN 61326. For details refer to the declaration of conformity.| ||**(EMC)**|• With regard to interference immunity the requirements for "industrial environment" are met.| |||• Influence of EMC < 1 % FS| |||**Process**| |**Process temperature range**||20°C to +60°C (4 °F to +140 °F)| |||A temperature sensor is integrated in the sensor for correction of the temperature-dependent time-of-flight.| |**Process pressure range**||0.7 bar to 3 bar abs. (10.15 psi to 43.5 psi)| 13 Endress+Hauser Prosonic T FMU30 ## **Mechanical construction** ## **Design; dimensions** **==> picture [388 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> A B<br>max. 76 max. 76<br>(2.99) (2.99)<br>ø85 (ø3.35) ø85 (ø3.35)<br>65 mm<br>65 mm<br>G 1½" G 2"<br>NPT 1½" NPT "2<br>ø39 (1.54) ø50 (1.97)<br>mm (in)<br>L00-FMU30xxx-06-00-00-xx-006<br>234 (9.21) 215 (8.46) 220 (8.66)<br>26<br>(1.02)<br> (3.23)<br>82<br>26<br>(1.02)<br>238 (9.37)<br>81 (3.19)<br>**----- End of picture text -----**<br> **A** _Sensor 1½"_ **B** _Sensor 2"_ ## **Weight** ## **Housing design** |**Sensor**<br>**We**|**ight**| |---|---| |1½"<br>app|rox. 0.75 kg (1.65 lbs)| |2"<br>app|rox. 0.8 kg (1.76 lbs)| ## **Type of housing** F16 plastic housing ## **Cover** ## Plastic cover - For version without on-site display (low, grey) - For version with on-site display (high, transparent) ## **Process connection** |**Sensor**<br>**Pro**|**cess connection**| |---|---| |1½"<br>• <br>•|Thread G 1½“, PP<br>Thread MNPT 1½“ - 11.5| |2"<br>• <br>•|Thread 2", PP<br>Thread MNPT 2" - 11.5| 14 Endress+Hauser Prosonic T FMU30 ## **Materials** **==> picture [180 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>13<br>3<br>12<br>4<br>11<br>10<br>9<br>8 5<br>7<br>6<br>**----- End of picture text -----**<br> L00-FMU3xxxx-16-00-00-xx-001 |**Pos.**|**Part**|**Material**| |---|---|---| |1|Cover (grey)|PBT| ||Cover (transparent)|PA| ||O-ring|EPDM| |2|Ground terminal:<br>Screws<br>Spring washer<br>Clamp<br>Holder|A2<br>A4<br>304 (1.4301)<br>301 (1.4310)| |3|Nameplate|Polyester| |4|O-ring|EPDM| |5|Sensor (in contact with process)|PP| |6|Matching Layer (in contact with process)|EPDM| |7|Counter nut (in contact with process)|PC| |8|Sealing (in contact with process)|EPDM| |9|Sealing|EPDM| |10|Adapter of housing|PBT GF 30-FR| |11|Goretex filter|PBT-20GF / grey RAL7035| |12|Cable gland|Polyamid (PA)| ||Plug|PBT-GF30| |13|Housing|PBT-FR| ## Note! The chemical compatibility of the sensors must be checked before installation with compatibility charts. 15 Endress+Hauser Prosonic T FMU30 ## **Operability** ## **Display and operating elements** The LCD module for display and operation is located beneath the housing cover. Open the cover to operate the device. **==> picture [387 x 233] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2<br>FEU31<br>4...20mA- +<br>%<br>Display E<br>4 3<br>L00-FMU30xxx-07-05-xx-xx-000<br>**----- End of picture text -----**<br> - _1 Display symbol_ - _2 Display (rotatable) 3 Plug-in module 4 Function keys_ |**Symbol in display**|continuous|flashing|| |---|---|---|---| |**Meaning**|Alarm|Warning|Security Locking| 16 Endress+Hauser Prosonic T FMU30 |**Function of the keys**|**Function of the keys**|**Function of the keys**|**Function of the keys**| |---|---|---|---| |**Key(s)**<br>(The keys to press are displayed in grey.)|||**Meaning**| ||||Navigate upwards in the selection list<br>Edit numeric value within a function| ||||| ||||| ||||Navigate downwards in the selection list<br>Edit numeric value within a function| ||||| ||||| ||||Navigate to the left within a function group| ||||| ||||| ||||Navigate to the right within a function group, confirmation.| ||||| ||||| |||or|Contrast settings of the LCD| ||||| ||||| ||||| ||||| ||||Hardware lock / unlock<br>After a hardware lock, an operation of the instrument via display or<br>communication is not possible!<br>The hardware can only be unlocked via the display. An unlock parameter must<br>be entered to do so (unlock parameter: 100).| ||||| ||||| 17 Endress+Hauser Prosonic T FMU30 **On-site operation** ## **Operation** The LC-Display allows configuration via 3 keys directly at the instrument. All device functions can be set through a menu system. The menu consists of function groups and functions. Within a function, application parameters can be read or adjusted. The user is guided through a complete configuration procedure. For ease operation can choose between 7 language: (de: german; en: english; es: spanish; fr: french; it: italian; ja: japanese; nl: dutch). **==> picture [357 x 251] intentionally omitted <==** **----- Start of picture text -----**<br> Headline Position indicator<br>4 z= |<br>M EASURED UALUE 8ee]) pol Boek x<br>‘ oo65.0 % Symbol ee Main value Bargraph Unit<br>_ + E ites = -_- =, 7 =_— a a ~~".<br>“ K E aw SL<br>Selection list<br>Function groups -> Functions<br>HOME<br>FG00 F000 F001 F002 F003 F004 ...<br>6°+ FG01FG02 aE E l ~ ho min, level~~<br>Help text<br>FG03<br>| FG06FG05FG04 O oO (oo6mne) ° 9 ;i iode RESi<br>(oe) FG07... Envelopcurve e a = et Terrea lcatasa—<br>**----- End of picture text -----**<br> **==> picture [56 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> L00-FMU30xxx-07-00-00-en-004<br>**----- End of picture text -----**<br> ## **Remote operation** ## **Operation with FieldCare** FieldCare is Endress+Hauser's FDT based Plant Asset Management Tool. It can configure all intelligent field devices in your plant and supports you in managing them. By using status information, it also provides a simple but effective means of checking their health. - Supports Ethernet, HART, PROFIBUS PA, FOUNDATION Fieldbus etc. - Operates all Endress+Hauser devices - Operates all third-party actuators, I/O systems and sensors supporting the FDT standard - Ensures full functionality for all devices with DTMs - Offers generic profile operation for any third-party fieldbus device that does not have a vendor DTM Connection for FMU30: - Commubox FXA291 and ToF adapter FXA291 (available as accessory) Using the following functions: - Signal analysis via envelope curve - Linearization table (graphically supported creation, editing, importing and exporting) - Loading and saving of instrument data (Upload/Download) - Documentation of measuring point 18 Endress+Hauser Prosonic T FMU30 ## _Menu-guided commissioning:_ _Signal analysis via envelope curve:_ 19 Endress+Hauser Prosonic T FMU30 ## **Certificates and Approvals** ||**CE mark**|The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms the| |---|---|---| |||instrument passing the required tests by attaching the CE-mark.| |**Ex approvals**||• ATEX| |||• IECEx| |||• CSA C/US| |||• NEPSI| |||Additional safety instructions must be observed for applications in hazardous areas. They arecontained in the| |||separate "Safety Instructions" (XA) document, which is included in the scope ofdelivery. Reference is made to| |||the XA on the nameplate of the device.| |||Note!| |||Details on the available certificats as well as the associated XAs can be found in the Associated documentation| |||chapter documentationä27.| |**Ex approval**||The available certificates are listed in the ordering information. Note the associated safety instructions (XA) and| |||control or installation drawings (ZD).| ## **External standards and EN 60529 guidelines** Protection class of housing (IP-code) ## **EN 61326 series** EMC product family standard for electrical equipment for measurement, control and laboratory use ## **NAMUR** User association for automation technology in process industries 20 Endress+Hauser Prosonic T FMU30 ## **Ordering information** ## **FMU30** Versions that mutually exclude one another are not marked. |**010**|**Approval:**|**Approval:**|**Approval:**|**Approval:**|**Approval:**|**Approval:**|**Approval:**|**Approval:**|**Approval:**| |---|---|---|---|---|---|---|---|---|---| |AA<br>Non-hazardous area<br>BB<br>ATEX II 1/2G Ex ia IIC T5<br>CA<br>CSA C/US General Purpose<br>CB<br>CSA C/US IS CI.I Div.1 Gr.A-D<br>IB<br>IEC Ex zone 0/1, Ex ia IIC T5 Ga/Gb<br>NB<br>NEPSI zone 0/1, Ex ia IIC T5 Ga/Gb<br>99<br>Special version|||||||||| |**020**|**Display; Operating:**||||||||| |G<br>W/o; via spare part display FMU30<br>H<br>Envelope curve display on site; push button<br>Y<br>Special version|||||||||| |**030**|**Electrical Connection:**||||||||| |E<br>Gland M20, IP68<br>F<br>Thread G1/2, IP68<br>G<br>Thread NPT1/2, IP68<br>Y<br>Special version|||||||||| |**040**|**Sensor; Max Range; Blocking Distance:**||||||||| |AA<br>1-1/2"; 5m liquid/2m solid; 0.25m<br>AB<br>2"; 8m liquid/3.5m solid; 0.35m<br>YY<br>Special version|||||||||| |**050**|**Process Connection:**||||||||| |GGF<br>Thread ISO228 G1-1/2, PP<br>GHF<br>Thread ISO228 G2, PP<br>RGF<br>Thread ANSI MNPT1-1/2, PP<br>RHF<br>Thread ANSI MNPT2, PP<br>YYY<br>Special version|||||||||| |**620**|**Accessory Enclosed:**||||||||| |RA<br>UNI flange 2"/DN50/50, PP max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>RB<br>UNI flange 2"/DN50/50, PVDF max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>RC<br>UNI flange 2"/DN50/50, 316L max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>RD<br>UNI flange 3"/DN80/80, PP max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>RE<br>UNI flange 3"/DN80/80, PVDF max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>RF<br>UNI flange 3"/DN80/80, 316L max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>RG<br>UNI flange 4"/DN100/100, PP max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>RH<br>UNI flange 4"/DN100/100, PVDF max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>RI<br>UNI flange 4"/DN100/100, 316L max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>R9<br>Special version|||||||||| |**895**|**Marking**:||||||||| ||Z1||Tagging (TAG),see additional spec.||||||| |You can enter the versions for the specific feature in the following table. The versions entered make up the<br>complete order code. Options which are mutuallyexclucive are not marked.|||||||||| |||**010**||**020**|**030**|**040**|**050**|**620**|**895**| |FMU30 -|||||||||| Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L with the material number 1.4404 or 1.4435. With regard to their temperature stability properties, the materials 1.4404 and 1.4435 are grouped under 13E0 in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical. 21 Endress+Hauser Prosonic T FMU30 ## **Scope of delivery** - Instrument according to the version ordered - Short instructions KA01054F; additional documentations on the supplied CD-ROM - For certified instrument versions: Safety Instructions, Control- or Installation drawings - Counter nut (PC): option 50, versions GGF/GHF, ä 21 "Ordering information" - Sealing ring (EPDM): option 50, versions GGF/GHF ä 21 "Ordering information" - For gland M20x1.5: 1 cable gland for 2-wire instruments The cable gland is mounted on delivery. ## **Accessories** ## **Installation bracket** **==> picture [387 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> 400 (15.7) 120 (4.72)<br>ø16 (0.6)<br>G<br>3 (0.12)<br>“N IGP mm (in)<br>A0019346<br>Process connection Order No. Material Weight<br>G 1½" 942669-0000<br>316 Ti (1.4571) 3.4 kg (7.5 lbs)<br>G 2" 942669-0001<br>———<br>suited for NPT 1½" and 2" as well<br>120<br>250 (9.84) (4.72)<br>30 (1.2)<br>**----- End of picture text -----**<br> 22 Endress+Hauser Prosonic T FMU30 ## **Screw in flange** **==> picture [386 x 118] intentionally omitted <==** **----- Start of picture text -----**<br> 4 1<br>3 2<br>A0019281<br>**----- End of picture text -----**<br> - _1 Screw in flange_ - _2 Nozzle_ - _3 Sensor_ - _4 Sealing ring EPDM (supplied)_ ## **Screw in flange FAX50** |**015**|**Material**:|**Material**:| |---|---|---| ||BR1<br>BS1<br>BT1<br>JF1<br>JG1<br>JH1<br>JK2<br>XIF<br>XIG<br>XIJ<br>XJF<br>XJG<br>XJJ<br>XKF<br>XKG<br>XKJ<br>XLF<br>XLG<br>XLJ<br>XMG<br>XNG<br>YYY|DN50 PN10/16 A, steel flange EN1092-1<br>DN80 PN10/16 A, steel flange EN1092-1<br>DN100 PN10/16 A, steel flange EN1092-1<br>2" 150lbs FF, steel flange ANSI B16.5<br>3" 150lbs FF, steel flange ANSI B16.5<br>4" 150lbs FF, steel flange ANSI B16.5<br>8" 150lbs FF, PP max 3bar abs/44psia flange ANSI B16.5<br>UNI flange 2"/DN50/50, PVDF max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>UNI flange 2"/DN50/50, PP max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>UNI flange 2"/DN50/50, 316L max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50<br>UNI flange 3"/DN80/80, PVDF max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>UNI flange 3"/DN80/80, PP max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>UNI flange 3"/DN80/80, 316L max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80<br>UNI flange 4"/DN100/100, PVDF max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>UNI flange 4"/DN100/100, PP max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>UNI flange 4"/DN100/100, 316L max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100<br>UNI flange 6"/DN150/150, PVDF max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150<br>UNI flange 6"/DN150/150, PP max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150<br>UNI flange 6"/DN150/150, 316L max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150<br>UNI flange DN200/200, PP max 4bar abs/58psia, suitable for DN200 PN16/10K 200<br>UNI flange DN250/250, PP max 4bar abs/58psia, suitable for DN250 PN16/10K 250<br>Special version| |**020**|**Sensor Connection**:|**Sensor Connection**:| |---|---|---| ||A<br>B<br>C<br>D<br>E<br>F<br>G<br>H<br>Y|Thread ISO228 G3/4<br>Thread ISO228 G1<br>Thread ISO228 G1-1/2<br>Thread ISO228 G2<br>Thread ANSI NPT3/4<br>Thread ANSI NPT1<br>Thread ANSI NPT1-1/2<br>Thread ANSI NPT2<br>Special version| The filled in options result in the complete order code. |||**015**|**020**| |---|---|---|---| |FAX50|-||| For more information, see the documentation TI00426F/00/EN. 23 Endress+Hauser Prosonic T FMU30 ## **Cantilever with mounting frame or wall bracket** **==> picture [386 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> A B<br>1 1<br>3 2<br>A0019566<br>**----- End of picture text -----**<br> - **A** _Installation with cantilever and wall bracket_ - **B** _Installation with cantilever and mounting frame_ - _1 Cantilever_ - _2 Mounting frame_ - _3 Wall bracket_ ## **Cantilever** **==> picture [386 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>35 (1.4)<br>D<br>M8<br>75 (2.9) 75 (2.9) 100 (3.9) B 35 (1.4)<br>mm (in)<br>A0019349<br>50 (2.0)<br>C<br>100 (3.9)<br>20 (0.8) 20 (0.8)<br>25 (1.0)<br>C<br>105 (4.1)<br>50/62 (2.0/2.4) 22 (0.9) 6.5 (0.3) 15 (0.6)<br>**----- End of picture text -----**<br> |**A**|**B**<br>**C**||**D**|**Weight**<br>**Senso**|**r**<br>**Material**|**Order Code**| |---|---|---|---|---|---|---| |585 (23)|250 (9.84)<br>2 (0.0|8)|200 (7.87|)<br>1.9 kg<br>(4.19 lbs)<br>1½"<br>2"|316Ti (1.4571)<br>galv. steel|52014132| |||||||52014131| ||||||316Ti (1.4571)<br>galv. steel|52014136| |||||||52014135| |1085 (42.7)|750 (29.5)<br>3 (0.1|2)|300 (11.8|)<br>4.4 kg<br>(9.7 lbs)<br>1½"<br>2"|316Ti (1.4571)<br>galv. steel|52014134| |||||||52014133| ||||||316Ti (1.4571)<br>galv. steel|52014138| |||||||52014137| |mm (in)||||||| - The 50 mm (2.17 in) or 62 mm (2.44 in) orifices serve for the mounting of the 1½" or 2" sensor, respecitvely. - The 22 mm (0.87 in) orifice may be used for an additional sensor. Fixing screws are supplied. 24 Endress+Hauser Prosonic T FMU30 ## **Mounting Frame** **==> picture [364 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> 3.2 (0.13)<br>60 (2.36)<br>ø33.7 (1.3)<br>20 (0.8) 4 (0.16)<br>55 (2.17)<br>100<br>130 (5.12) (3.94)<br>150 (5.91)<br>mm (in)<br>700/1400<br>13 (0.5) 100 (3.94) (27.6 / 55.1) 76 (2.99)<br>45 (1.77) 6.5 (0.3) 100 200 (7.87)<br>(3.94)<br>25 (0.98)<br>**----- End of picture text -----**<br> **==> picture [18 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> A0019279<br>**----- End of picture text -----**<br> |**Height**<br>**M**|**aterial**|**Weight**|**Order Code**| |---|---|---|---| |700 (27.6)<br>ga|lv. steel|3.2 kg (7.06 lbs)|919791-0000| |700 (27.6)<br>3|16Ti (1.4571)||919791-0001| |1400 (55.1)<br>ga|lv. steel|4.9 kg (10.08 lbs)|919791-0002| |1400 (55.1)<br>3|16Ti (1.4571)||919791-0003| |mm (in)|||| ## **Wall Bracket** **==> picture [386 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> 3.2 (0.1)<br>5 (0.2)<br>ø33.7 (1.3)<br>6.5 (0.3)<br>25 (1.0)<br>~ 88 (3.5) 110 (4.3)<br>150 (5.9)<br>mm (in)<br>A0019350<br>180 (7.1) ~213 (8.4)<br>13 (0.5) 110 (4.3) 150 (5.9)<br>**----- End of picture text -----**<br> |**Material**|**Weight**|**Order Code**| |---|---|---| |galv. steel|1.4 kg (3.09 lbs)|919792-0000<br>919792-0001| |316Ti (1.4571)||| 25 Endress+Hauser Prosonic T FMU30 ## **Weather protection cover** A Weather protection cover is recommended for outdoor mounting. **==> picture [386 x 494] intentionally omitted <==** **----- Start of picture text -----**<br> ø110 (4.33) 140 (5.51)<br>114 (4.49)<br>220 (8.66)<br>200 (7.87)<br>A<br>mm (in)<br>L00-FMU30-00-00-00-xx-000<br>A Foam pad<br>45°<br>140 (5.51)<br>140<br>**----- End of picture text -----**<br> |**Material**|**Order No.**|**Weight**<br>|**Operating conditions**| |---|---|---|---| |PBT, grey|71127762|240 g (8.46 oz)<br>|50 °C to +150 °C (58 °F to +302 °F)| 26 Endress+Hauser Prosonic T FMU30 |**Commubox FXA291**|The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB<br>interface of a personal computer or a notebook. For details refer to TI00405C/07/EN.<br>Note!<br>For the FMU30 you need the "ToF Adapter FXA291" as an additional accessory.|The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB<br>interface of a personal computer or a notebook. For details refer to TI00405C/07/EN.<br>Note!<br>For the FMU30 you need the "ToF Adapter FXA291" as an additional accessory.|The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB<br>interface of a personal computer or a notebook. For details refer to TI00405C/07/EN.<br>Note!<br>For the FMU30 you need the "ToF Adapter FXA291" as an additional accessory.|The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB<br>interface of a personal computer or a notebook. For details refer to TI00405C/07/EN.<br>Note!<br>For the FMU30 you need the "ToF Adapter FXA291" as an additional accessory.| |---|---|---|---|---| |**ToF Adapter FXA291**|The ToF Adapter FXA291 connects the Commubox FXA291 via the USB interface of a personal computer or<br>a notebook to the FMU30.<br>For details refer to KA00271F/00/A2.<br>**Documentation**|||| |**Operating manual**|**BA00387F**<br>This instruction describe the installation and first commissioning of the instrument. From the operating menu,<br>all functions are included, which are required for standard measurement tasks. Additional functions are not<br>contained in the manual.<br>The documentation can be found on the supplied documentation CD. The documentation is also available via<br>the Internetsiehe: www.endress.com Download.|||| |**Description of device**<br>**functions**|**BA00388F**<br>This contains a detailed description of all the functions of the isntrument and is valid for all communication<br>variants.<br>The documentation can be found on the supplied documentation CD. The documentation is also available via<br>the Internetwww.endress.com Download.|||| |**Short instructions**|**KA01054F**<br>is for rapid commissioning of the device. The instructions are attached to the device. The documentation can<br>be found on the supplied documentation CD.<br>The documentation is also available via the Internetwww.endress.com Download.<br>**KA00290F**<br>can be found under the device housing cover.<br>The most important menu functions are summarised on this sheet. It is intended primarily as a memory jogger<br>for users who are familiar with the operating concept of Endress+Hauser time-of-flight instruments.|||| |Safety Instructions|Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They<br>are an integral part of the Operating Instructions.|||| ||Certificate/type of protection|**Documentation**|Order code|| ||||Feature|Version| ||ATEX II 1/2 G Ex ia IIC T5 Ga/Gb|XA01054F|10|BB| ||IECEx, Ex ia IIC T5 Ga/Gb|||CB| ||Ex ia Class I, Division 1, Group A-D, T5<br>Class I, Zone 0, AEx/Ex ia IIC T5 Ga|XA01080F||IB| ||NEPSI Zone 0/1, Ex ia IIC T5 Ga/Gb|XA01264F||NB| For certified devices the relevant Safety Instructions (XA) are indicated on the nameplate. 27 Endress+Hauser ## **Instruments International** Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com **==> picture [122 x 36] intentionally omitted <==** TI00440F/00/EN/15.14 71225633 SGML+FM10 71225633
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →