- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 222.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
**RGC**
## **RGC**
## **1-Phase Solid State Contactors, ‘E’- type connection**
## **Benefits**
- **Panel space savings.** The slimmest product in the range accomodates up to 37 AAC in a width of only 17.5 mm giving 25% space saving per SSR compared to 22.5 mm solutions.
- **Less maintenance costs.** Wire bonding technology reduces thermal and mechanical stresses of the output chips resulting in a larger number of operational cycles compared to other assembly technologies.
- **Low machine downtime.** Integrated overvoltage protection prevents the solid state relay from breaking down due to uncontrolled transients that may occur on the lines.
## **Description**
This slimline range of solid state contactors is an evolution of solid state switches for which Carlo Gavazzi is very well known. The RG solid state contactors present a unique opportunity for panel space savings thanks to their very slim footprint.
The **RGC** is the ready-to-use range that is provided with an integrated heatsink. The smallest footprint occupies only a width of 17.5 mm with ratings up to 37 AAC. The power and control teminals allow for safe looping of cables. Springloaded pluggable control terminals are an option when faster installation time is required.
- **Ease of use.** The RGC ready-to-use solution is provided with integrated heatsink thus eliminating the need for the user to calculate the size of heatsink needed for adequate thermal dissipation.
- **Cost effective protection co-ordination** . The high I²t specification permits easy Type 2 protection co-ordination with B-type Minitaure Circuit Breakers.
- **Fast wiring** . Power connections for models rated ≥37 A are equipped with terminals that can handle cables up to 25 mm[2] / AWG3 cables. Spring loaded control terminals are also available that help reduce installation time.
- **Accommodates UL508A requirements for Industrial Control Panels.** The RGC is certified as a listed product. All models carry a 100 kArms Short Circuit Current Rating.
- **Protection against SSR overheat.** Optional feature with integrated over temperature protection protects the RGC output from getting damaged in case of overheating. This feature is present by default on the variants with integrated fan and optional on other variants.
The RGC output is protected against overvoltages by means of an integrated varistor. Control ON indication is provided through a green LED.
Specifications are at a surrounding temperature of 25°C unless otherwise specified.
## **Applications**
Plastic injection machines, extrusion machines, blow moulding machines, thermoformers, dryers, electrical ovens, fryers, shrink tunnels, air handling units, sterilisation equipment, climatic chambers, ovens and furnaces, ambient heating.
## **Main features**
- Ratings up to 660 VAC, 85 A @ TA 40°C
- Up to 18000 A²s for I²t for protection coordination with M.C.Bs
- 100kA short circuit current rating according to UL508
- Conformance to Railway standards
**1**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
**==> picture [483 x 509] intentionally omitted <==**
**----- Start of picture text -----**<br>
Order code<br>RGC1 E<br>Enter the code option instead of . Refer to the selection guide section for valid part numbers.<br>Code Option Description Comments<br>R -<br>Solid State Relay (RG)<br>G -<br>C - With integrated heatsink<br>1 - 1-pole switching<br>A Zero Cross switching (ZC)<br>B Instant ON switching (IO)<br>23 Rated voltage: 24-264 VAC, 800 Vp<br>60 Rated voltage: 42-660 VAC, 1200 Vp<br>D Control voltage: 3-32 VDC 4-32 VDC for 600 VAC version<br>A Control voltage: 20-275 VAC, 24-190 VDC<br>15 Rated current: 20 AAC (525 A²s) 17.5 mm wide, low depth<br>20 Rated current: 23 AAC (525 A²s) 17.5 mm wide<br>25 Rated current: 25 AAC (1800 A²s) 17.5 mm wide, low depth<br>30 Rated current: 30 AAC (1800 A²s) 22.5 mm wide<br>32 Rated current: 30 AAC (18000 A²s) 17.5 mm wide, low depth<br>17.5 mm wide, low depth -<br>32 Rated current: 37 AAC (18000 A²s) only with box clamp power terminals<br>40 Rated current: 40 AAC (3200 A²s) 35 mm wide<br>42 Rated current: 43 AAC (18000 A²s) 35 mm wide<br>60 Rated current: 60 AAC (3200 A²s) 70 mm wide<br>62 Rated current: 65 AAC (18000 A²s) 70 mm wide<br>K Screw connection for control terminals<br>M Pluggable spring-loaded connection for control terminals<br>Applicable only for:<br>K Screw connection for power terminals<br>RGC..15, 20, 25, 30, 32<br>Applicable only to:<br>G Box clamp connection for power terminals<br>RGC..32, 40, 42, 60, 62<br>E - Contactor configuration<br>-<br>Single packaging<br>Applicable only to:<br>X20 Bulk packaging of 20 pcs.<br>RGC..15, 25, 32<br>**----- End of picture text -----**<br>
Refer to page 3 for the Order Code of the RGC with integrated Over Temperature Protection
**2**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Order code - integrated Over Temperature Protection**
**RGC1A60 G EP**
**==> picture [484 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
Enter the code option instead of . Refer to selection guide section for valid part numbers.<br>Code Option Description Comments<br>R -<br>Solid State Relay (RG)<br>G -<br>C - With integrated heatsink<br>1 - 1-pole switching<br>A - Zero Cross switching (ZC)<br>60 - Rated voltage: 42-660 VAC, 1200 Vp<br>D Control voltage: 5-32 VDC<br>A Control voltage: 20-275 VAC, 24-190 VDC Applicable only for: RGC..92..P<br>30 Rated current: 30 AAC (1800 A²s) 22.5 mm wide<br>42 Rated current: 43 AAC (18000 A²s) 35 mm wide<br>62 Rated current: 65 AAC (18000 A²s) 70 mm wide<br>92 Rated current: 85 AAC (18000 A²s) 70 mm wide with fan<br>G - Box clamp connection for control terminals<br>K Screw connection for power terminals Applicable only for: RGC..30..P<br>G Box clamp connection for power terminals<br>E - Contactor configuration<br>P - Integrated Over Temperature Protection<br>**----- End of picture text -----**<br>
**3**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Selection guide**
## For 17.5 mm wide variants having low depth heatsink:
**==> picture [483 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated operational current @ 40°C<br>Rated 20 AAC 25 AAC 30 AAC 37 AAC<br>voltage, Control (525 A [2] s) (1800 A [2] s) (18000 A [2] s) (18000 A [2] s)<br>Switching voltage<br>Product width<br>mode<br>17.5 mm, low depth 17.5 mm, low depth 17.5 mm, low depth 17.5 mm, low depth<br>3 - 32 VDC RGC1A23D15KKE RGC1A23D25KKE - -<br>230 VAC,<br>ZC 20-275 VAC, RGC1A23A15KKE RGC1A23A25KKE - -<br>24-190 VDC<br>RGC1A60D15KKE RGC1A60D25KKE RGC1A60D32KKE RGC1A60D32KGE<br>4- 32 VDC<br>600 VAC, RGC1A60D15MKE RGC1A60D25MKE RGC1A60D32MKE RGC1A60D32MGE<br>ZC 20-275 VAC,24-190 VDC RGC1A60A15MKERGC1A60A15KKE RGC1A60A25MKERGC1A60A25KKE - -<br>600 VAC, 4- 32 VDC - RGC1B60D25KKE - -<br>IO<br>**----- End of picture text -----**<br>
For 17.5 mm wide and 22.5 mm wide variants:
**==> picture [483 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated operational current @ 40°C<br>Rated 23 AAC 30 AAC<br>voltage, Control (525 A [2] s) (1800 A [2] s) - -<br>Switching voltage<br>mode Product width<br>17.5 mm 22.5 mm - -<br>3 - 32 VDC RGC1A23D20KKE RGC1A23D30KKE - -<br>230 VAC,<br>ZC 20-275 VAC, RGC1A23A20KKE RGC1A23A30KKE - -<br>24-190 VDC<br>4- 32 VDC RGC1A60D20KKE RGC1A60D30KKE - -<br>600 VAC, RGC1A60D20MKE RGC1A60D30MKE<br>ZC 20-275 VAC,24-190 VDC RGC1A60A20MKERGC1A60A20KKE RGC1A60A30MKERGC1A60A30KKE - -<br>600 VAC, 4- 32 VDC - RGC1B60D30KKE - -<br>IO<br>**----- End of picture text -----**<br>
## For 35 mm wide and 70 mm wide variants:
**==> picture [483 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated operational current @ 40°C<br>Rated 40 AAC 43 AAC 60 AAC 65 AAC<br>voltage, Control (3200 A [2] s) (18000 A²s) (3200 A²s) (18000 A²s)<br>Switching voltage<br>mode Product width<br>35 mm 35 mm 70 mm 70 mm<br>RGC1A60D40KGE RGC1A60D42KGE RGC1A60D60KGE RGC1A60D62KGE<br>600 VAC, 4- 32 VDC - RGC1A60D42MGE - RGC1A60D62MGE<br>ZC 20-275 VAC, RGC1A60A40KGE RGC1A60A42KGE RGC1A60A60KGE RGC1A60A62KGE<br>24-190 VDC - RGC1A60A42MGE - RGC1A60A62MGE<br>600 VAC, 4- 32 VDC - RGC1B60D42KGE - RGC1B60D62KGE<br>IO<br>**----- End of picture text -----**<br>
KKE: input terminals = screw KGE: input terminals = screw MKE: input terminals = pluggable spring MGE: input terminals = pluggable spring
output terminals = screw output terminals = box clamp output terminals = screw output terminals = box clamp
**4**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Selection guide - continued**
For variants with integrated Over Temperature Protection:
|||**Rated operational current @ 40°C**|**Rated operational current @ 40°C**|**Rated operational current @ 40°C**|**Rated operational current @ 40°C**|
|---|---|---|---|---|---|
|**Rated**<br>**voltage,**<br>**Sithi**|**Control**<br>**lt**|**30 AAC**<br>**(1800 A²s)**|**43 AAC**<br>**(18000 A2s)**|**65 AAC**<br>**(18000 A2s)**|**85 AAC**<br>**(18000 A²s)**|
|**wcng**<br>**mode**|**voage**|**Product width**||||
|||**22.5 mm**|**35 mm**|**70 mm**|**70 mm + fan**|
|**600 VAC,**<br>**ZC**|5 - 32 VDC|RGC1A60D30GKEP|RGC1A60D42GGEP|RGC1A60D62GGEP|RGC1A60D92GGEP|
||20-275 VAC,<br>24-190 VDC|-|-|-|RGC1A60A92GGEP|
GKEP: input terminals = box clamp output terminals = screw GGEP: input terminals = box clamp output terminals = box clamp
For variants with bulk packaging of 20 pcs.
**==> picture [483 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated operational current @ 40°C<br>Rated 20 AAC 25 AAC 30 AAC<br>voltage, Control (525 A²s) (1800 A [2] s) (18000 A [2] s) -<br>Switching voltage<br>mode Product width<br>-<br>17.5 mm, low depth 17.5 mm, low depth 17.5 mm, low depth<br>3 - 32 VDC RGC1A23D15KKEX20 RGC1A23D25KKEX20 - -<br>230 VAC,<br>ZC 20-275 VAC,24-190 VDC - - - -<br>4 - 32 VDC RGC1A60D15KKEX20 RGC1A60D25KKEX20 RGC1A60D32MKEX20 -<br>600 VAC,<br>ZC 20-275 VAC, RGC1A60A15KKEX20 RGC1A60A25KKEX20 - -<br>24-190 VDC<br>**----- End of picture text -----**<br>
## **Carlo Gavazzi compatible components**
|**Description**|**Component code**|**Notes**|
|---|---|---|
|**Control Plugs**|RGM25|Pack of 10 spring loaded control plugs|
## **Carlo Gavazzi further reading**
**==> picture [483 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
Information Where to find it Notes<br>Datasheet https://gavazziautomation.com/images/PIM/DATASHEET/ Solid state contactor, RGC with 'U' - type<br>ENG/rgc_u.pdf configuration<br>Datasheet https://gavazziautomation.com/images/PIM/DATASHEET/ Solid state relay, RGS series without<br>ENG/rgs.pdf integrated heatsink<br>**----- End of picture text -----**<br>
**5**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**==> picture [32 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC<br>**----- End of picture text -----**<br>
**==> picture [37 x 37] intentionally omitted <==**
## **Structure**
**==> picture [181 x 288] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..KKE<br>PE<br>Heatsink<br>1/L1<br>A1+<br>A2- LED<br>2/T1<br>**----- End of picture text -----**<br>
**==> picture [51 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..KGE<br>**----- End of picture text -----**<br>
**==> picture [483 x 435] intentionally omitted <==**
**----- Start of picture text -----**<br>
PE<br>Heatsink<br>1/L1<br>A1+<br>A2- LED<br>2/T1<br>A1+<br>LED<br>A2-<br>2/T1<br>Element Component Function<br>1/L1 Power connection Mains connection<br>2/T1 Power connection Load connection<br>A1+, A2- Control connection Terminals for control voltage<br>LED ON indicator Indicates presence of control voltage<br>Heatsink Integrated heatsink DIN rail mounting (panel mounting also possible)<br>PE Protective Earth Connection for Protective Earth, PE screw not provided with RGC<br>**----- End of picture text -----**<br>
**6**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**==> picture [32 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC<br>**----- End of picture text -----**<br>
**==> picture [37 x 37] intentionally omitted <==**
## **Structure**
|**Structure**|**Structure**|**Structure**|**Structure**|
|---|---|---|---|
|**RGC...D92GGEP***<br>**RGC...30GKEP**<br>LED<br>A1+<br>Heatsink<br>1/L1<br>2/T1<br>PE<br>LED<br>A2-<br>LED<br>LED<br>12-<br>11+<br>2/T1<br>Heatsink<br>1/L1<br>PE<br>A1+<br>A2-<br>IN1<br>OUT<br>IN3<br>IN2||||
|A1+<br>A2-<br>12-<br>11+|LED<br>Heatsink<br>1/L1<br>2/T1<br>PE<br>LED<br>LED<br>LED<br>2/T1<br>Heatsink<br>1/L1<br>PE<br>A1+<br>A2-<br>IN1<br>OUT<br>IN3<br>IN2|||
|||||
|**Element**|**Component**|**Function**||
|**1/L1**|Power connection|Mains connection||
|**2/T1**|Power connection|Load connection||
|**A1+, A2-**|Control connection|Terminals for control voltage (Supply voltage for RGC..D92GGEP)||
|**IN1**|Control connection|Terminals for control voltage (Only for RGC..D92GGEP)||
|**11+, 12-, OU**|**T**<br>Alarm output|Alarm output signal, Normally closed (OUT only for RGC..D92GGEP)||
|**IN2, IN3**|Fan supply connection|Terminals for fan supply||
|**LED, Green**|<br>CONTROL indicator|Indicates presence of control voltage||
|**LED, Red**|FAULT indicator|Indicates presence of an over temperature fault||
|**Heatsink**|Integrated heatsink|DIN rail mounting (panel mounting also possible)||
|**PE**|Protective Earth|Connection for Protective Earth, PE screw not provided with RGC||
- Refer to Terminal layout section for terminal labelling reference of RGC..A92GGEP
**7**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
## **RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Features**
## **General data**
|**Material**|PA66 or PA6 (UL94 V0), RAL7035<br>Glow wire ignition temperature and Glow wire fammability index conform to<br>EN 60335-1 requirements|
|---|---|
|**Mounting**|DIN rail (panel mount also possible)|
|**Touch Protection**|IP20|
|**Overvoltage Category**|III, 6 kV (1.2/50 μs) rated impulse withstand voltage|
|**Isolation**|Input and Output to Case:<br>Input to Output:<br>Input to FAN/ Alarm Output:<br>4000 Vrms<br>4000 Vrms, 2500 Vrms for RGC..D..P<br>2500 Vrms applicable only to RGC..A..P|
|**Weight**|RGC..15, RGC..25, RGC..32:<br>RGC..20:<br>RGC..32xGE:<br>RGC..30 / P:<br>RGC..4x / P:<br>RGC..6x / P:<br>RGC..92P<br>approx. 260 g<br>approx. 315 g<br>approx. 269 g<br>approx. 375 g / 412 g<br>approx. 515 g / 581 g<br>approx. 972 g / 1020 g<br>approx. 1100g|
## **Performance**
## **Output specifications**
**==> picture [483 x 280] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..15.. RGC..20.. RGC..25.. RGC..30.. RGC..32..KE RGC..32..GE<br>Max. operational current [1] :<br>20 AAC 25.5 AAC 30 AAC 30 AAC 30 AAC 43 AAC<br>AC-51 @ Ta=25°C<br>Max. operational current [1] :<br>20 AAC 23 AAC 25 AAC 30 AAC 30 AAC 37 AAC<br>AC-51 @ Ta=40°C<br>Max. operational current [1] :<br>5 AAC 5 AAC 5 AAC 8 AAC 5 AAC 5 AAC<br>AC-53a @ Ta=40°C<br>Operational frequency range 45 to 65 Hz<br>Output protection Integrated varistor<br>Leakage current @ rated voltage <3 mAAC<br>Minimum operational current 150 mAAC 150 mAAC 250 mAAC 250 mAAC 500 mAAC 500 mAAC<br>Repetitive overload current<br>(Motor rating) UL508: Ta=40°C, 51 AAC 60 AAC 51 AAC 84 AAC 51 AAC 51 AAC<br>tON=1 s, tOFF=9 s, 50 cycles<br>Non-repetitive surge current<br>325 Ap 325 Ap 600 Ap 600 Ap 1900 Ap 1900 Ap<br>(ITSM), t=10 ms<br>I²t for fusing (t=10 ms), min. 525 A²s 525 A²s 1800 A²s 1800 A²s 18000 A²s 18000 A²s<br>No. of motor starts per hour [2]<br>30<br>(x=6, Tx=6s, F=50%) @ 40°C<br>Power factor >0.5 at rated voltage<br>Critical dV/dt (@Tj init = 40°C) 1000 V/μs<br>**----- End of picture text -----**<br>
1. Refer to Current derating curves
2. Overload profile for AC-53a; Ie: AC-53a: xIe-Tx: F-S, where Ie = nominal current (AC-53a AAC), xIe = overload current (AAC), Tx = duration of overload current (seconds), F = duty cycle (%), S = number of starts. Example; 5A: AC-53a: 30-6 : 50-30 = max. 30 starts for the RGC..15 with an overload profile of 30 A for 6 seconds with a duty cycle of 50%
**8**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Output specifications - continued**
**==> picture [483 x 280] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..40.. RGC..42.. RGC..60.. RGC..62.. RGC..92..P<br>Max. operational current [1] :<br>47 AAC 50 AAC 70 AAC 75 AAC 85 AAC<br>AC-51 @ Ta=25°C<br>Max. operational current [1] :<br>40 AAC 43 AAC 60 AAC 65 AAC 85 AAC<br>AC-51 @ Ta=40°C<br>Max. operational current [1] :<br>13 AAC 16 AAC 14.8 AAC 20 AAC 20 AAC<br>AC-53a @ Ta=40°C<br>Operational frequency range 45 to 65 Hz<br>Output protection Integrated varistor<br>Leakage current @ rated voltage <3 mAAC<br>Minimum operational current 400 mAAC 500 mAAC 400 mAAC 500 mAAC 500 mAAC<br>Repetitive overload current<br>(Motor rating) UL508: Ta=40°C, 126 AAC 126 AAC 126 AAC 168 AAC 168 AAC<br>tON=1 s, tOFF=9 s, 50 cycles<br>Non-repetitive surge current<br>800 Ap 1900 Ap 800 Ap 1900 Ap 1900 Ap<br>(ITSM), t=10 ms<br>I²t for fusing (t=10 ms), min. 3200 A²s 18000 A²s 3200 A²s 18000 A²s 18000 A²s<br>No. of motor starts per hour [2]<br>30<br>(x=6, Tx=6s, F=50%) @ 40°C<br>Power factor >0.5 at rated voltage<br>Critical dV/dt (@Tj init = 40°C) 1000 V/μs<br>**----- End of picture text -----**<br>
1. Refer to Current derating curves
2. Overload profile for AC-53a; Ie: AC-53a: xIe-Tx: F-S, where Ie = nominal current (AC-53a AAC), xIe = overload current (AAC), Tx = duration of overload current (seconds), F = duty cycle (%), S = number of starts. Example; 5A: AC-53a: 30-6 : 50-30 = max. 30 starts for the RGC..15 with an overload profile of 30 A for 6 seconds with a duty cycle of 50%
## **Output voltage specifications**
**==> picture [483 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..23.. RGC..60..<br>24-240 VAC, 42-600 VAC,<br>Operational voltage range<br>+10% -15% on max +10% -15% on max<br>Blocking voltage 800 Vp 1200 Vp<br>Internal varistor 275 V 625 V<br>**----- End of picture text -----**<br>
## **Motor ratings: HP (UL508) / kW (EN/IEC 60947-4-2) @ 40°C**
**==> picture [483 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
115 VAC 230 VAC 400 VAC 480 VAC 600 VAC<br>RGC..15 1/3HP / 0.18kW 1HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW<br>RGC..20 ½HP / 0.18kW 1½HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW<br>RGC..25 1/3HP / 0.18kW 1HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW<br>RGC..30 ¾HP / 0.37kW 2HP / 1.1kW 3HP / 1.5kW 5HP / 2.2kW 5HP / 3.7kW<br>RGC..32 1/3HP / 0.18kW 1HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW<br>RGC..40 1HP / 0.56kW 3HP / 1.5kW 5HP / 2.2kW 5HP / 2.2kW 7½HP / 4kW<br>RGC..42 1½HP / 0.56kW 3HP / 1.5kW 5HP / 2.2kW 7½HP / 3.7kW 10HP / 4kW<br>RGC..60 1½HP / 0.56kW 3HP / 1.5kW 5HP / 3kW 7½HP / 4kW 10HP / 4kW<br>RGC..62 2HP / 0.75kW 5HP / 1.5kW 7½HP / 4kW 10HP / 4kW 15HP / 5.5kW<br>RGC..92 2HP / 0.75kW 5HP / 1.5kW 7½HP / 4kW 10HP / 4kW 15HP / 5.5kW<br>**----- End of picture text -----**<br>
**9**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
## **Input specifications**
||**RGC..D..**|**RGC..A..**|
|---|---|---|
|**Control voltage range3 RGC..23..**<br>**RGC..60..**|3 - 32 VDC<br>4 - 32 VDC|20-275 VAC,<br>24 (-10%) -190 VDC|
|**Control voltage range RGC...P**|5 - 32 VDC||
|**Control voltage frequency range**|-|45 to 65 Hz|
|**Pick-up voltage RGC..23..**<br>**RGC..60..**|**RGC..60..**<br>3.0 VDC<br>3.8 VDC|20 VAC/DC|
|**Pick-up voltage RGC..P**|5 VDC|20 VAC/ 24 VDC|
|**Drop-out voltage**|1.0 VDC|5 VAC/DC|
|**Maximum reverse voltage**|32 VDC|-|
|**Maximum response time RGC1A..**|0.5 cycle + 500μs@24 VDC|2 cycles@230 VAC/110 VDC|
|**Maximum response time RGC1B..**|350μs@24 VDC|-|
|**Response time drop-out**|0.5 cycle + 500μs@24 VDC|0.5 cycle + 40μs@230 VAC/110 VDC|
|**Input current@ 40°C**|See diagrams below||
3. For DNV approved models control range for RGC1.23... is 4-32VDC and for RGC1.60... 5-32VDC
## **Input current vs. input voltage**
**==> picture [224 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..D<br>A1 Characteristics: DC input current vs Input voltage [x]<br>25.0mA RGC..D..P<br>(Normal Operation)<br>20.0mA<br>RGC..D..P<br>(Active Protection)<br>15.0mA L e<br>———<br>10.0mA RGC..D.<br>5.0mA oe<br>2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V<br>eqdearrresnarasraniss<br> x: Input currents for all models except RGC1..D92GGEP<br>**----- End of picture text -----**<br>
## **RGC..A**
**==> picture [227 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC1 .. A : input current vs input voltage<br>40m A<br>35m A<br>30mA<br>25m A<br>[\<br>20m A u RGC .. A<br>15m A RGC..A..P<br>(Normal Operation)<br>10mA<br>RGC..A..P<br>5mA (Active Protection)<br>0mA inhi sua tte<br>0VAC 50VAC 100VAC 150VAC 200VAC 250VAC 300VAC<br>**----- End of picture text -----**<br>
**==> picture [477 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
20.0mA IN1 Characteristics: DC input current vs Input voltagex [y] RGC1 .. A : input current vs input voltage<br>40m A<br>RGC..D92GGEP RGC..A..P<br>15.0mA (Normal Operation) FEECEECE 35m A LTTE (Active Protection)<br>30mA<br>10.0mA pee ere 25m A PINE ETE T T LETTEEET<br>5.0mA C RGC..D92GGEP(Active Protection SHB) ) 20m A A RGC .. A<br>15m A<br>REECE EER SS ert N ELTA IN EEENEEE<br>0.0mA 10mA<br>2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V RGC..A..P<br>5mA (Normal Operation)<br>y: input currents valid only for RGC1..D92GGEP<br>0mA iliiiscarenes<br>0VDC 50VDC 100VDC 150VDC 200VDC 250VDC<br>**----- End of picture text -----**<br>
**10**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Overtemperature alarm specifications - RGC..P**
**==> picture [483 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..D..P RGC..A..P<br>Output type PNP open collector Potential Free<br>Normal state Closed<br>Visual indication Continous red LED when fault (over temperature) is present<br>Maximum current rating 50 mADC<br>Rated voltage, Ua (11, 12, OUT) [4, 5 ] 24 VDC -15%, +20%<br>Rated supply voltage, Us (A1)<br>24V DC ± 10% N/A<br>only for RGC..D92GGEP<br>Fan supply rating, Uf (IN2, IN3)<br>N/A 24 VDC ±10%, 50 mA nominal<br>only for RGC..A92GGEP<br>Alarm voltage drop Typical 2.8 VDC 1.8 VDC<br>Maximum 4.0 VDC 3.5 VDC<br>**----- End of picture text -----**<br>
4. According to EN 61131-2: 2003. DC supply for alarm signal should be supplied from a Class 2 power source
5. Maximum voltage to be applied between 11+ and 12- (Ua) terminals should be 35VDC maximum with reference to A2-
## **Output power dissipation**
**==> picture [484 x 316] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>90<br>80<br>70<br>60<br>RGC..15, 20<br>50 RGC..25, 30<br>RGC..40, 60<br>40 RGC..32, 42, 62, 92<br>30<br>20<br>10<br>0<br>0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85<br>Load Current in AACrms<br>Load current (AAC)<br>Power dissipation (W)Power Dissipa�on in W<br>**----- End of picture text -----**<br>
**11**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Current derating**
**==> picture [483 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
44<br>42<br>40<br>RGC..32.GE<br>38<br>36 RGC..32.KE<br>34<br>32 RGC..30<br>30<br>28 RGC..25<br>26<br>RGC..20<br>24<br>22<br>RGC..15<br>20<br>18<br>16<br>14<br>12<br>10<br>8<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>Load Current in AACrmsLoad current (AAC)<br>**----- End of picture text -----**<br>
**==> picture [483 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
90<br>80 RGC..92<br>70<br>RGC..62<br>60<br>RGC..60<br>50<br>40 RGC..42<br>30<br>RGC..40<br>20<br>10<br>0<br>0 10 20 30 40 50 60 70 80<br>Surrounding Ambient Temperature in Surrounding ambient temperature (°C) [o] C<br>Load current (AAC)<br>Load Current in AACrms<br>**----- End of picture text -----**<br>
RGC...P models max. operating temperature is + 70˚C / + 158°F
**12**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**==> picture [32 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC<br>**----- End of picture text -----**<br>
**==> picture [37 x 37] intentionally omitted <==**
## **Derating vs. spacing curves**
**==> picture [483 x 629] intentionally omitted <==**
**----- Start of picture text -----**<br>
RGC..15..<br>25<br>20<br>0mm<br>15<br>5mm<br>10<br>10mm & over<br>5<br>0<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..20.. 35<br>30<br>25 0mm<br>20 10mm<br>10mm<br>15<br>20mm & over<br>10<br>5<br>0<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..25..<br>30<br>25<br>0mm<br>20 5mm<br>15 10mm<br>10 22.5mm & over<br>5<br>0<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..30..<br>35<br>30<br>0mm<br>25 5mm<br>10mm & over<br>20<br>Stand alone unit<br>15<br>10<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>Load Current in AAC<br>Load current (AAC)<br>ent in AAC<br>Load Curr<br>Load current (AAC)<br>Load current (AAC)Load Current in AAC<br>Load Current in AAC<br>Load current (AAC)<br>**----- End of picture text -----**<br>
> Carlo Gavazzi Ltd. **13**
15/05/2026 RGC DS ENG
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
**==> picture [484 x 635] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating vs. Spacing curves<br>RGC..32.. [6] 40<br>35<br>30<br>25 0mm<br>5mm<br>20<br>20mm<br>15 Stand alone<br>10<br>5<br>0<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..40.. 50<br>45<br>40<br>35 0mm<br>30 10mm & over<br>25<br>Stand alone unit<br>20<br>15<br>10<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..42..<br>0mm<br>22.5mm & over<br>Surrounding ambient temperature (°C)<br>RGC..60..<br>70<br>65<br>60<br>0mm<br>55<br>50 10mm & over<br>45<br>Stand alone unit<br>40<br>35<br>30<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>Load Current in AAC<br>Load current (AAC)<br>Load Current in AAC<br>Load current (AAC)<br>Load current (AAC)<br>Load Current in AAC<br>Load current (AAC)<br>**----- End of picture text -----**<br>
6. UL current ratings for the RGC..32KKE/MKE are limited to max. 30 AAC. Current derating vs. spacing tests are carried out in an unventilated panel. The max. rating for the RGC..32KGE/MGE in such conditions is limited to max. 35 AAC.
**14**
15/05/2026
RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [421 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating vs. Spacing curves<br>RGC..62.. 75<br>oj} _| {| | | [| | |<br>6s posspoeepes fT<br>o SR ee 0mm<br>eS<br>10mm & over<br>0<n<br>Stand alone unit<br>eg | | | ft Se<br>oS<br>oe<br>i<br>0 10 20 30 40 50 60 70 80<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>RGC..92GGEP<br>90<br>85<br>80<br>7 5 ae > — -- 0mm<br>70 ~e . > ~~ _. 10mm & over<br>65 Stand alone unit<br>60 a > .<br>55<br>50<br>0 10 20 30 40 50 60 70<br>Surrounding ambient temperature (°C)Surrounding Ambient Temperature in °C<br>Load current (AAC)Load Current in AAC<br>Load Current in AAC<br>Load current (AAC)<br>**----- End of picture text -----**<br>
**==> picture [402 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Compatibility and conformance<br>7 8, 9<br>Approvals DNV<br>C E:W« LISTED 2S a (=) onvcompae FAL<br>LVD: EN/IEC 60947-4-2, EN/IEC 60947-4-3<br>EMCD: EN/IEC 60947-4-3<br>Standards compliance UL: UL508 (E172877), NMFT<br>cUL: C22.2 No. 14 (E172877), NMFT7<br>VDE: VDE0660-109<br>UL short circuit current rating 100 kArms (refer to short circuit current section, Type 1 – UL508)<br>**----- End of picture text -----**<br>
7. RGC..32 models are not VDE approved
8. DNV approval applicable only to models RGC..15, RGC..20, RGC..25 and RGC..30.
9. DNV is not applicable to models having Mexico as the country of origin
**15**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
**==> picture [484 x 397] intentionally omitted <==**
**----- Start of picture text -----**<br>
Electromagnetic compatibility (EMC) - Immunity<br>EN/IEC 61000-4-2<br>Electrostatic discharge (ESD)<br>8 kV air discharge, 4 kV contact (PC1)<br>EN/IEC 61000-4-3<br>10 V/m, from 80 MHz to 1 GHz (PC1)<br>Radiated radio frequency<br>10 V/m, from 1.4 to 2 GHz (PC1)<br>10 V/m, from 2 to 2.7 GHz (PC1)<br>EN/IEC 61000-4-4<br>Electrical fast transient (burst) Output: 2 kV, 5 kHz (PC1)<br>Input: 1 kV, 5 kHz (PC1)<br>EN/IEC 61000-4-6<br>Conducted radio frequency<br>10 V/m, from 0.15 to 80 MHz (PC1)<br>Electrical surge EN/IEC 61000-4-5<br>Output, line to line: 1 kV (PC1)<br>Output, line to earth: 2 kV (PC1)<br>Input, line to line, 1 kV (PC2)<br>Input, line to earth, 2 kV (PC2)<br>RGC..P DC lines, line to line, 500 V (PC2)<br>RGC..P DC lines, line to earth, 500 V (PC2)<br>RGC..P Signal lines, line to earth, 1 kV (PC2)<br>EN/IEC 61000-4-11<br>0% for 0.5, 1 cycle (PC2)<br>Voltage dips 40% for 10 cycles (PC2)<br>70% for 25 cycles (PC2)<br>80% for 250 cycles (PC2)<br>EN/IEC 61000-4-11<br>Voltage interruptions<br>0% for 5000 ms (PC2)<br>Electromagnetic compatibility (EMC) - Emissions<br>Radio interference field EN/IEC 55011<br>emission (radiated) Class A: from 30 to 1000 MHz<br>EN/IEC 55011<br>Radio interference voltage<br>Class A: from 0.15 to 30 MHz<br>emissions (conducted) (External filter may be required - refer to Filtering section)<br>**----- End of picture text -----**<br>
## **Additional conformance to railway standards**
|**Additional conformance**|**to railway standards**|
|---|---|
|**Applicable to variants**|RGC..|
|**Additional conformance**<br>**specifc to railway applications**|EN 50155<br>EN 45545-2<br>EN 50121-3-2|
|**Hazardous level conformance**<br>**according to EN 45545-2**|HL1, HL2 for requirement R23<br>HL1 for requirement R22|
|**Operating temperature class**<br>**according to EN 50155**|OT3 (-25 °C to +70 °C )|
|**Vibration and shock**|EN 61373 Category1, Class B|
|**Additional EMC conformance**|accordingto EN 50121-3-2|
|**Radiated radio frequency**<br>**immunity**|EN/IEC 61000-4-3<br>20 V/m, from 80 MHz to 1 GHz (PC1)<br>10 V/m, from 1.4 to 2 GHz (PC1)<br>5 V/m, from 2 to 2.7 GHz (PC1)<br>3 V/m, 5.1 - 6 GHz (PC1)|
|**Power quality measurement**|EN/IEC 61000-4-30<br>50 Hz - 2 kHz, <8% THD (PASS)|
**16**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Filter connection diagram**
**==> picture [456 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 Phase 3 Phase<br>L1 SSR<br>L2 SSR LOAD<br>L3 SSR<br>Rd Rd Rd Rd = 1MΩ, 0.5W<br>N Filter has to be connected<br>across both LOAD and SSR<br>**----- End of picture text -----**<br>
## **Filtering**
**==> picture [483 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Part number Suggested filter for EN 55011 Class A Maximum heater current [AAC]<br>compliance<br>**----- End of picture text -----**<br>
|**Part number**|**Suggested flter for EN 55011 Class A**<br>**compliance**|**Maximum heater current [AAC]**|
|---|---|---|
||||
|RGC1A23..15|68nF/ 275 V / X1|20 AAC|
|RGC1A23..20|68nF/ 275 V / X1|20 AAC|
|RGC1A23..25, RGC1A23..30|220 nF / 275V / X1|30 AAC|
|RGC1A23..40, RGC1A23..60|220 nF / 275V / X1<br>330 nF / 275V / X1|30 AAC<br>45 AAC|
|RGC1A23..42, RGC1A23..62|330 nF / 275V / X1<br>680 nF / 275V / X1|35 AAC<br>65 AAC|
|RGC1A60..15|100 nF / 760V / X1|20 AAC|
|RGC1A60..20|100 nF / 760V / X1|20 AAC|
|RGC1A60..25, RGC1A60..30|220 nF / 760V / X1|30 AAC|
|RGC1A60..40, RGC1A60..60|220 nF / 760V / X1<br>330 nF / 760V / X1|25 AAC<br>45 AAC|
|RGC1A60..32, RGC1A60..42,<br>RGC1A60..62, RGC1A60..92|330 nF / 760V / X1<br>680 nF / 760V / X1|40 AAC<br>65 AAC|
## Note:
- Control input lines must be installed together to maintain products’ susceptability to Radio Frequency interference.
- Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indications, the filter attenuation will depend on the final application.
- This product has been designed for Class A equipment. Use of this product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods.
- Performance Criteria 1 (PC1): No degradation of performance or loss of function is allowed when the product is operated as intended.
- Performance Criteria 2 (PC2): During the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself.
- Performance Criteria 3 (PC3): Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls.
**17**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Environmental specifications**
|**Operating temperature**<br>**RGC..P**|-40°C to +80°C (-40°F to +176°F)<br>-30°C to +70°C(-22°F to +158°F)|
|---|---|
|**Storage temperature**|-40 to +100°C(-40 to +212 °F)|
|**Relative humidity**|95% non-condensing @40°C|
|**Pollution degree**|2|
|**Installation altitude**|0-1000 m. Above 1000 m derate linearly by 1% of FLC per 100 m up to a maximum<br>of 2000 m|
|**Vibration resistance**|2g/ axis(2-100Hz, IEC 60068-2-6, EN 50155, EN 61373)|
|**Impact resistance**|15/11g/ms(EN50155, EN61373)|
|**EU RoHS compliant**|Yes|
|**China RoHS**|25|
The declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/ T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products.
||**Toxic or Harardous Substances and Elements**|**Toxic or Harardous Substances and Elements**|**Toxic or Harardous Substances and Elements**|**Toxic or Harardous Substances and Elements**|**Toxic or Harardous Substances and Elements**|**Toxic or Harardous Substances and Elements**|
|---|---|---|---|---|---|---|
|**Part Name**|Lead<br>(Pb)|Mercury<br>(Hg)|Cadmium<br>(Cd)|Hexavalent<br>Chromium<br>(Cr(Vl))|Polybrominat-<br>ed biphenyls<br>(PBB)|Polybromi-<br>nated diphenyl<br>ethers (PBDE)|
|**Power Unit**<br>**Assembly**|x|O|O|O|O|O|
|O: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit<br>requirement of GB/T 26572.<br>X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above<br>the limit requirement of GB/T 26572.|||||||
## 这份申明根据中华人民共和国电子工业标准
## SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质
||有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|有毒或有害物质与元素|
|---|---|---|---|---|---|---|
|零件名称|铅<br>(Pb)|汞<br>(Hg)|镉<br>(Cd)|六价铬<br>(Cr(Vl))|多溴化联苯<br>(PBB)|多溴联苯醚<br>(PBDE)|
|功率单元|x|O|O|O|O|O|
|O:此零件所有材料中含有的该有害物低于GB/T 26572的限定。<br>X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。|||||||
**18**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Short circuit protection**
## **Protection Co-ordination, Type 1 vs Type 2:**
Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In Type 2 co-ordination the device under test will still be functional after the short circuit. In both cases, however the short circuit has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not be blown open. There shall be no damage to conductors or terminals and the conductors shall not separate from terminals. there shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is impaired. Discharge of parts or any risk of fire shall not occur.
The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than 100,000 Arms Symmetrical Amperes, 600 Volts maximum when protected by fuses. Tests at 100,000 A were performed with Class J fuses, fast acting; please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only.
Tests with Class J fuses are representative of Class CC fuses.
**==> picture [484 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection co-ordination Type 1 according to UL 508<br>Prospective short<br>Part No. circuit current Max fuse size [A] Class Voltage [VAC]<br>[kArms]<br>**----- End of picture text -----**<br>
|**Protection co-ordination Type 1 according to UL 508**|**Protection co-ordination Type 1 according to UL 508**|**Protection co-ordination Type 1 according to UL 508**|**Protection co-ordination Type 1 according to UL 508**|**Protection co-ordination Type 1 according to UL 508**|
|---|---|---|---|---|
|**Part No.**|**Prospective short**<br>**circuit current**<br>**[kArms]**|**Max fuse size [A]**|**Class**|**Voltage [VAC]**|
||||||
|RGC..15|100|30|J or CC|Max. 600|
|RGC..20||30|J or CC||
|RGC..25||30|J or CC||
|RGC..30||30|J or CC||
|RGC..32||80|J||
|RGC..40||40|J||
|RGC..42||90|J||
|RGC..60||40|J||
|RGC..62||90|J||
|RGC..92||90|J||
**19**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
**==> picture [483 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection co-ordination Type 2 (IEC/EN 60947-4-2/ -4-3)<br>Ferraz Shawmut (Mersen) Siba<br>Prospective short<br>Part No. circuit current [kArms] Max fuse size [A] Part number Max fuse size [A] Part number Max. voltage [VAC]<br>**----- End of picture text -----**<br>
|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|**Protection co-ordination Type 2(IEC/EN 60947-4-2/ -4-3)**|
|---|---|---|---|---|---|---|
|**Part No.**|**Prospective short**<br>**circuit current**<br>**[kArms]**|**Ferraz Shawmut (Mersen)**||**Siba**||**Max. voltage**<br>**[VAC]**|
|||**Max fuse**<br>**size [A]**|**Part number**|**Max fuse**<br>**size [A]**|**Part number**||
||||||||
|RGC..15|10|25|6.9xx CP GRC 14x51 /25|32|50 142 06.32|600|
||100||||||
|RGC..20|10|40|6.6xx CP URD 22x58 /40|32|50 142 06.32|600|
||100||||||
|RGC..25|10|40|6.6xx CP URD 22x58 /40|32|50 142 06.32|600|
||100||||||
|RGC..30|10|40|6.9xx CP GRC 22x58 /40|32|50 142 06.32|600|
||100||||||
|RGC..40|10|63|6.621 CP URGD 27x60 /63|63|50 194 20.63|600|
|||70|A70QS70-4||||
||100|63|6.621 CP URQ 27x60 /63||||
|RGC..32<br>RGC..42|10|63|6.9xx CP URC 14x51 /63|80|50 194 20.80|600|
|||70|A70QS70-4||||
||100|63|6.9xx CP URC 14x51 /63||||
|||70|A70QS70-4||||
|RGC..60<br>up to 65AAC|10|80|6.621 CP URQ 27x60 /80|80|50 194 20.80|600|
||100|-|-||||
|RGC..62|10|100|6.9xx CP GRC 22x58 /100|100|50 194 20.100|600|
||||A70QS100-4||||
||100||6.621 CP URGD 27x60 /100||||
||||A70QS100-4||||
|RGC..92|10|125|6.621 CP URQ 27x60 /125|125|50 194 20.125|600|
||||A70QS125-4||||
||100||6.621 CP URQ 27x60 /125||||
||||A70QS125-4||||
xx = 00, without fuse trip indication, xx= 21, with fuse trip indication
**20**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
**==> picture [484 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection co-ordination Type 2 with Miniature Circuit Breakers (M.C.B.s)<br>ABB Model no. for ABB Model no. for<br>Wire cross sectional area Minimum length of Cu<br>Solid State Relay type Z - type M. C. B. B - type M. C. B.<br>[mm [2] ] wire conductor [m] [10]<br>(rated current) (rated current)<br>**----- End of picture text -----**<br>
|**Protection co-ordination Type 2 with Miniature Circuit Breakers(M.C.B.s)**|**Protection co-ordination Type 2 with Miniature Circuit Breakers(M.C.B.s)**|**Protection co-ordination Type 2 with Miniature Circuit Breakers(M.C.B.s)**|**Protection co-ordination Type 2 with Miniature Circuit Breakers(M.C.B.s)**|**Protection co-ordination Type 2 with Miniature Circuit Breakers(M.C.B.s)**|
|---|---|---|---|---|
|**Solid State Relay type**|**ABB Model no. for**<br>**Z - type M. C. B.**<br>**(rated current)**|**ABB Model no. for**<br>**B - type M. C. B.**<br>**(rated current)**|**Wire cross sectional area**<br>**[mm2]**|**Minimum length of Cu**<br>**wire conductor [m]10**|
||||||
|RGC..15<br>RGC..20<br>(525 A2s)|S201 - Z4 (4A)|S201 - B2 (2A)|1.0<br>1.0<br>1.5|21.0<br>21.0<br>31.5|
||S201 - Z6 UC (6A)|S201 - B2 (2A)|||
|RGC..25<br>RGC..30<br>(1800 A2s)|S201 - Z10 (10A)|S201-B4 (4A)|1.0<br>1.5<br>2.5|7.6<br>11.4<br>19.0|
||S201 - Z16 (16A)|S201-B6 (6A)|1.0<br>1.5<br>2.5<br>4.0|5.2<br>7.8<br>13.0<br>20.8|
||S201 - Z20 (20A)|S201-B10 (10A)|1.5<br>2.5|12.6<br>21.0|
||S201 - Z25 (25A)|S201-B13 (13A)|2.5<br>4.0|25.0<br>40.0|
||S202 - Z25 (25A)|S202-B13 (13A)|2.5<br>4.0|19.0<br>30.4|
|RGC..40<br>(3200 A2s)|S201 - Z25 (25A)|S201 - B13 (13A)|2.5<br>4.0<br>6.0|7.0<br>11.2<br>16.8|
|RGC..60<br>(3200 A2s)|S201 - Z25 (25 )|S201 - B13 (13A)|2.5<br>4.0<br>6.0|7.0<br>11.2<br>16.8|
|RGC..32<br>RGC..42<br>RGC..62<br>RGC..92<br>(18000 A2s)|S201-Z32 (32A)|S201-B16 (16A)|2.5<br>4.0<br>6.0|3.0<br>4.8<br>7.2|
||S201-Z50 (50A)|S201-B25 (25A)|4.0<br>6.0<br>10.0<br>16.0|4.8<br>7.2<br>12.0<br>19.2|
||S201-Z63 (63A)|S201-B32 (32A)|6.0<br>10.0<br>16.0|7.2<br>12.0<br>19.2|
10. Between MCB and Load (including return path which goes back to the mains)
Note: A prospective current of 6 kA and a 230 / 400 V power supply is assumed for the above suggested specifications. For cables with different cross section than those mentioned above please consult Carlo Gavazzi's Technical Support Group.
S201 models refer to 1-pole M.C.B., S202 models refer to 2-poles M.C.B.
**21**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Over temperature alarm procedure and fan operation for versions with integrated fan**
**==> picture [462 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
ALARM Signal and Fan<br>(applicable to RGC..D92GGEP) ALARM Signal and FAN ALARM Signal only ALARM Signal only<br>START START<br>Is Chip N Chip N<br>temperature > temperature<br>115°C ? limit reached?<br>Y Y<br>SSR output: OFF<br>FAN: ON Red LED: ON<br>Alarm Signal: ON<br>Is Chip Chip N Chip N<br>temperature < 86 5°C ? limittemperature reached? temperature < Chip N<br>80°C?<br>Y<br>Y<br>SSR output: OFF Y<br>Red LED: ON<br>FAN: OFF Alarm Signal: ON SSR output: ON<br>Red LED: OFF<br>Alarm Signal: OFF<br>Is Chip N<br>temperature <<br>65°C?<br>Y<br>SSR output: ON<br>Red LED: OFF<br>Alarm Signal: OFF<br>FAN: OFF<br>**----- End of picture text -----**<br>
## CAUTION
- Alarm condition resets whenever the voltage signal is removed from terminal A1 (+)
- In the case of RGC1A60D92GGEP, if the voltage signal is not applied across A1(+) and A2 (-) terminals, the overtemperature detection and functionality is lost (including fan operation and alarm signalling)
- In the case of RGC1A60A92GGEP it is necessary to supply IN2 and IN3 with 24VDC for fan operation.
- Alarm procedure for RGC1A60A92GGEP follows ‘Alarm signal only’ flow since fan is continously operating.
- Alarm condition automatically resets ONLY when power semiconductor temperature < 80˚C
- Temperatures indicated are typical figures.
**22**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Dimensions**
## **RGC..15KKE, RGC..25KKE, RGC..32KKE**
## **RGC..15MKE, RGC..25MKE, RGC..32MKE**
**==> picture [194 x 571] intentionally omitted <==**
**----- Start of picture text -----**<br>
109.5 [4.31’’] 4.5 5.4<br>92<br>44.5<br>35.5<br>3.2<br>4.4<br>8 17.8 [0.70’’]<br>147 [5.78’’] 5.4<br>129.5 4.5<br>44.5<br>35.5<br>3.2<br>4.4<br>8 17.8 [0.70’’]<br>147 [5.78’’] 5.4<br>129.5 4.5<br>44.5<br>35.5<br>3.2<br>4.4<br>8<br>17.8<br>22.5 [0.89’’]<br>Ø 4.4<br>Ø 4.4<br>Ø 4.4<br>90 100.4<br>110 [4.33’’]<br>43.8<br>90 100.4<br>110 [4.33’’]<br>43.8<br>90 100.4<br>110 [4.33’’]<br>43.8<br>**----- End of picture text -----**<br>
**==> picture [352 x 605] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.4<br>98.5 [3.88’’] 4.5 92<br>51 44.5<br>35.5 35.5<br>3.2<br>4.4<br>8 17.8 [0.70’’]<br>RGC..20KKE RGC..20MKE<br>5.4 147 [5.78’’]<br>136 [5.35’’] 4.5 129.5<br>51 44.5<br>35.5 35.5<br>3.2<br>4.4<br>8 17.8 [0.70’’]<br>RGC..30KKE RGC..30MKE<br>5.4 147 [5.78’’]<br>136 [5.35’’] 4.5 129.5<br>51 44.5<br>35.5 35.5<br>3.2<br>4.4<br>8<br>17.8<br>22.5 [0.89’’]<br>Housing width tolerance +0.5mm, -0mm as per DIN 43880. All other tolerances +/- 0.5mm.<br>Dimensions in mm.<br>Ø 4.4<br>Ø 4.4<br>Ø 4.4<br>90 100.4<br>110 [4.33’’]<br>43.8<br>90 100.4<br>110 [4.33’’]<br>43.8<br>90<br>100.4<br>110 [1.33’’]<br>43.8<br>**----- End of picture text -----**<br>
**23**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Dimensions - continued**
## **RGC..32KGE**
**==> picture [229 x 566] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.4<br>98.5 [3.88’’] 4.5<br>51<br>43.7<br>3.2<br>4.4<br>8<br>17.8<br>RGC..40KGE, RGC..42KGE<br>5.4<br>136 [5.5’’] 4.5<br>51<br>43.7<br>3.2<br>4.4<br>8<br>17.8<br>35.6 [1.40’’]<br>RGC..60KGE, RGC..62KGE<br>136 [5.35’’] 4.5 17.85.4<br>51<br>43.7<br>3.2<br>4.4 4.4<br>8 43.2 8<br>17.8 17.8<br>70 [2.76’’]<br>Ø 4.4<br>Ø 4.4<br>Ø 4.4<br>90 4.33’’][<br>100.4<br>110<br>43.8<br>90 4.33’’][<br>100.4<br>110<br>43.8<br>’’33]<br>90 4.[<br>100.4 011<br>43.8<br>**----- End of picture text -----**<br>
## **RGC..32MGE**
**==> picture [211 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
109.5 [4.31’’] 4.5 5.4<br>92<br>44.5<br>43.7<br>1 L1<br>3.2<br>2 T1<br>4.4<br>8<br>17.8<br>Ø 4.4<br>’’]<br>90<br>100.4 110 [4.33<br>43.8<br>**----- End of picture text -----**<br>
**RGC..40MGE, RGC..42MGE**
**==> picture [230 x 379] intentionally omitted <==**
**----- Start of picture text -----**<br>
147 [5.78’’] 5.4<br>129.5 4.5<br>44.5<br>43.7<br>3.2<br>4.4<br>8<br>17.8<br>35.6 [1.40’’]<br>RGC..62MGE<br>147 [5.78’’] 17.8<br>129.5 4.5 5.4<br>44.5<br>43.7<br>3.2<br>4.4 4.4<br>8 43.2 8<br>17.8 17.8<br>70 [2.76’’]<br>Ø 4.4<br>Ø 4.4<br>90<br>100.4<br>110 [4.33’’]<br>43.8<br>90 100.4 4.33’’][<br>110<br>43.8<br>**----- End of picture text -----**<br>
Housing width tolerance +0.5mm, -0mm as per DIN 43880. All other tolerances +/- 0.5mm. Dimensions in mm.
**24**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Dimensions - Over Temperature Protection**
## **RGC..30GKEP**
## **RGC..42GGEP**
**==> picture [231 x 356] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.4<br>163 [6.42’’] 4.5<br>78<br>43.7<br>4.4<br>8<br>17.8<br>22.5 [0.89’’]<br>RGC..62GGEP<br>163 [6.42’’] 4.5 17.85.4<br>78<br>43.7<br>4.4 4.4<br>8 43.2 8<br>17.8 17.8<br>70 [2.76’’]<br>Ø 4.4<br>Ø 4.4<br>60.5 90 100.4<br>110 [4.33’’]<br>60.5 90 100.4 4.33’’][<br>110<br>**----- End of picture text -----**<br>
## **RGC..62GGEP**
**==> picture [232 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.4<br>163 [6.42’’] 4.5<br>78<br>43.7<br>4.4<br>8<br>17.8<br>35.6 [1.40’’]<br>Ø 4.4<br>60.5 90 100.4<br>110 [4.33’’]<br>**----- End of picture text -----**<br>
## **RGC..92GGEP**
**==> picture [231 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
17.8<br>163 [6.42’’] 4.5 5.4<br>78<br>43.7<br>4.4 4.4<br>8 43.2 8<br>70 [2.76’’]<br>Ø 4.4<br>60.5 90 100.4 4.33’’][ 5.12’’][<br>110 130<br>**----- End of picture text -----**<br>
Housing width tolerance +0.5mm, -0mm as per DIN 43880. All other tolerances +/- 0.5mm. Dimensions in mm.
**25**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Terminal layout**
**==> picture [161 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 L1 1 L1<br>L1<br>A1 A1 L1<br>A2 T1 A2 T1<br>ON ON<br>A1 A2<br>A1 A2<br>2 T1 2 T1<br>CARLO GAVAZZI<br>GSSSRdiloctihttaew<br>GSSSRdiloctihttaew<br>**----- End of picture text -----**<br>
RGC..15KKE, RGC..20KKE, RGC..25KKE, RGC..30KKE, RGC..32KKE, RGC..32KGE
RGC..15MKE, RGC..20MKE, RGC..25MKE, RGC..30MKE, RGC..32MKE, RGC..32MGE
**==> picture [201 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 L1 1 L1<br>2 T1 2 T1<br>**----- End of picture text -----**<br>
RGC..40KGE, RGC..42KGE, RGC..60KGE, RGC..62KGE
RGC..40MGE, RGC..42MGE, RGC..62MGE
1/L1: Mains supply connection
2/T1: Load connection
A1(+): Positive control signal
A2(-): Control ground
: Protective Earth
## **Terminal layout - Over Temperature Protection**
**==> picture [433 x 199] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 L1 1 L1 1 L1 1 L1<br>ALARMOUT CONTROLIN1 SUPPLYA1+ 11+ 12 - A1 OUTALARM CONTROLIN1 SUPPLYA1 11+ 12 - A1<br>CONTROL<br>CONTROL<br>FAULT<br>FAULT<br>GNDA2- I IN2 N2 I IN3 N3 A A2 2 IN2FAN + IN3FAN - A2GND IIN2N2 IIN3N3 A2A2<br>2 T1 2 T1 2 T1 2 T1<br>RGC..30GKEP RGC..42GGEP RGC..D92GGEP RGC..A92GGEP<br>RGC..62GGEP<br>RG Solid state Switch GSSSRildtihttoaecw<br>**----- End of picture text -----**<br>
- 1/L1: Mains supply connection
- 2/T1: Load connection
A1(+): Positive control signal, Positive supply voltage in case of RGC1A60D92GGEP
- A2 (-): Control ground
IN1: Control signal (only for RGC1A60D92GGEP)
IN2: Fan +supply (only for RGC1A60A92GGEP)
IN3: Fan -supply (only for RGC1A60A92GGEP)
11+ : Alarm output (+)
OUT, 12 - : Alarm output (-), OUT only for RGC1A60D92GGEP
- : Protective earth
**26**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
## **RGC**
## **Connection diagram**
**==> picture [419 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
Variant without Over Temperature Protection Variant with Over Temperature Protection<br>L1 L1<br>L2/N L2/N<br>* *<br>1 L1<br>1 ‘©<br>©.= ¥ 8 1+ 11 + 66 12 12 - - Ate A1<br>teb i mom Vv<br>3 oC)<br>2 O o<br>Ale = A2 -<br>ESLAYQW LA)WW a<br>Control q A2<br>input L_ZN<br>WY GGG<br>©, U ©, 2 a ¥ T1 as<br>Load Load<br>CONTROL<br>FAULT<br>ALARM ALARM SUPPLY<br>GND<br>GSSSRdilohctittaew<br>**----- End of picture text -----**<br>
* depends on system requirements
## **Connection diagram - Auxiliary connections for Over Temperature Protection variants**
**==> picture [415 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC Control AC Control<br>RGC1...D30GKEP RGC1...D92GGEP RGC1...A92GGEP<br>RGC1...D42GGEP<br>RGC1...D62GGEP<br>prcmcceennenne yeeeeee-y Alarm coy<br>: {Out i Alarm!<br>: oem i OO,O i Out. }<br>: Out. ; H UcT Us H 06 0<br>'meerOOO 4i pels :i sua Uc<br>: ' loo<br>weabove Ww -Ua<br>ov<br>BS me<br>Be O ©) O ov Ut +- bP|6 bus<br>O ov (Red)aan (Black)tit (Red)FAN+ (Black)FAN-<br>Uc: 5 - 32 VDC Uc: 5 - 32 VDC Uc: 24 - 275 VAC<br>Ua: max 35VDC Us: 24 VDC 24 - 190 VDC<br>Alarm Output: max. 50mA Alarm Output: max. 50mA Ua: max. 35 VDC<br> Alarm Output: max. 50mA<br>Note: Fan is internally supplied Uf: 24 VDC (needs to be<br> supplied externally)<br>A1, A2: Control voltage A1, A2: Supply voltage A1, A2: Control voltage<br>11, 12: Alarm output IN1: Control voltage 11, 12: Alarm output<br>OUT: Alarm output IN2, IN3: Fan supply<br>**----- End of picture text -----**<br>
**27**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
**==> picture [37 x 37] intentionally omitted <==**
## **Functional diagram**
## **DC control**
**==> picture [266 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
A1( +) REGULATION T1<br>ZC<br>IO<br>A2(-) L1<br>AC control<br>A1(+~) REGULATION T1<br>ZC<br>A2(-~) L1<br>**----- End of picture text -----**<br>
## **Installation**
**==> picture [478 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
Y1 = 50mm<br>RGC RGC<br>X X<br>X = Refer to<br>Y2 =<br>Derating vs.<br>Spacing Curves 100mm<br>RGC<br>50mm<br>Mounting on DIN rail Dismounting from DIN rail<br>**----- End of picture text -----**<br>
**28**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
## **Connection Specifications**
|**Power connections**<br>~~Cn~~<br>~~es~~|**Power connections**<br>~~Cn~~<br>~~es~~|**Power connections**<br>~~Cn~~<br>~~es~~|**Power connections**<br>~~Cn~~<br>~~es~~|
|---|---|---|---|
|**Terminals**<br>~~Cn~~<br>~~es~~|1/L1, 2/T1<br>~~Cn~~|||
|**Conductors**<br>~~es~~<br>~~i~~|Use 75°C copper(Cu)conductors|||
|~~i~~|RGC..KKE, RGC..MKE, RGC..GKEP||RGC..KGE, RGC..MGE, RGC..GGEP|
|||||
|**Connection type**<br>~~i~~|M4 screw with captivated washer||M5 screw with box clamp|
|**Stripping length**<br>~~a~~|12 mm<br>||11 mm<br>|
|**Rigid (solid & stranded)**<br>**UL/cUL rated data**<br>|2x 2.5 – 6.0 mm²<br>2x 14 – 10 AWG<br>|1x 2.5 – 6.0 mm²<br>1x 14 – 10 AWG<br>|1x 2.5 – 25.0 mm²<br>1x 14 – 3 AWG<br>|
|**Flexible with end sleeve**<br>~~ef~~|2x 1.0 – 2.5 mm²<br>2x 2.5 – 4.0 mm²<br>2x 18 – 14 AWG<br>2x 14 – 12 AWG<br>~~ef~~|1x 1.0 – 4.0 mm²<br>1x 18 – 12 AWG<br>~~ef~~|1x 2.5 – 16.0 mm²<br>1x 14 – 6 AWG<br>~~ef~~|
|**Flexible without end**<br>**sleeve**<br>~~ef~~|2x 1.0 – 2.5 mm²<br>2x 2.5 – 6.0 mm²<br>2x 18 – 14 AWG<br>2x 14 – 10 AWG<br>~~ef~~|1x 1.0 – 6.0mm²<br>1x 18 –10 AWG<br>~~ef~~|1x 4.0 – 25.0 mm²<br>1x 12 – 3 AWG<br>~~ef~~|
|**Torque specifications**|Pozidriv bit 2<br>UL: 2.0 Nm (17.7 lb-in)<br>IEC: 1.5 – 2.0 Nm (13.3 – 17.7 lb-in)||Pozidriv bit 2<br>UL: 2.5 Nm (22 lb-in)<br>IEC: 2.5 – 3.0 Nm (22 – 26.6 lb-in)<br>~~ee~~|
|**Aperture for termination**<br>**lug (fork or ring)**<br>~~ee~~|12.3 mm<br>~~ee~~||n/a<br>~~ee~~<br>~~ee~~|
|**Protective Earth (PE)**<br>**connection**|M5, 1.5 Nm (13.3 lb-in)<br>M5 PE screw is not provided with the solid state relay. PE connection is required when product is<br>intended to be used in Class 1 applications according to EN/IEC 61140<br>~~ee~~|||
|**Control connections**<br>~~Cn~~<br>~~ee~~|**Control connections**<br>~~Cn~~<br>~~ee~~|**Control connections**<br>~~Cn~~<br>~~ee~~|**Control connections**<br>~~Cn~~<br>~~ee~~|**Control connections**<br>~~Cn~~<br>~~ee~~|**Control connections**<br>~~Cn~~<br>~~ee~~|
|---|---|---|---|---|---|
|**Terminals**<br>~~ee~~|A1+, A2-|||A1+, A2-, IN1, IN2, IN3, 11+, 12-, OUT||
|**Conductors**<br>~~ee~~<br>~~a~~<br>~~rarernrsnt~~<br>~~ee~~|Use 60/75°C copper (Cu) conductors<br>~~rarernrsnt~~|||||
|~~i rarernrsnt~~<br>~~ee~~|RG..KKE, RG..KGE<br>screw control terminal<br>~~rarernrsnt~~||RG..MKE<br>spring plug<br>control terminal<br>~~rarernrsnt~~|RG..P<br>~~rarernrsnt~~||
||~~rarernrsnt~~|~~rarernrsnt~~|~~rarernrsnt~~|~~rarernrsnt~~|~~rarernrsnt~~|
|**Connection type**<br>~~rarernrsnt~~<br>~~ee~~<br>~~es~~|M3 screw with captivated washer<br>~~rarernrsnt~~<br>~~es~~||Spring loaded<br>~~rarernrsnt~~<br>~~es~~|M3 screw with box clamp<br>~~rarernrsnt~~<br>~~es~~||
|**Stripping length**<br>~~rarernrsnt~~<br>~~ee~~<br>~~es~~<br>~~es~~|8 mm<br>~~rarernrsnt~~<br>~~es~~<br>~~eeee~~||12-13 mm<br>~~rarernrsnt~~<br>~~es~~<br>~~ee~~|6 mm<br>~~rarernrsnt~~<br>~~es~~<br>~~ee~~||
|**Rigid (solid & stranded)**<br>**UL/cUL rated data**<br>~~es~~<br>~~es~~|2x 0.5 - 2.5 mm2<br>2x 18 - 12 AWG<br>~~es~~<br>~~ee~~|1x 0.5 - 2.5 mm2<br>1x 18 - 12 AWG<br>~~es~~<br>~~ee~~|1x 0.2 - 2.5 mm2<br>1x 24 - 12 AWG<br>~~es~~<br>~~ee~~|2x 1.0 - 2.5 mm2<br>2x 18 - 14 AWG<br>~~es~~<br>~~ee~~|1x 1.0 - 2.5 mm2<br>1x 18 - 14 AWG<br>~~es~~<br>~~ee~~|
|**Flexible with end sleeve**<br>~~es ~~|2x 0.5 - 2.5 mm2<br>2x 18 - 12 AWG<br> ~~ee ~~|1x 0.5 - 2.5 mm2<br>1x 18 - 12 AWG<br> ~~ee~~|-<br>~~ee~~|2x 1.0 - 2.5 mm2<br>2x 18 - 14 AWG<br>~~ee~~|1x 1.0 - 2.5 mm2<br>1x 18 - 14 AWG<br>~~ee~~|
|**Torque specification**|Pozidriv 1<br>UL: 0.5 Nm (4.4 lb-in),<br>IEC: 0.5-0.6 Nm (4.4-5.3 lb-in)||-|Pozidriv 1<br>UL: 0.5 Nm (4.4 lb-in),<br>IEC: 0.4-0.5 Nm (3.5-4,4 lb-in)||
**29**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
**RGC**
## **Bulk packaging option**
- Packing qty.: 20 pcs.
- Total weight : 4.75 kg
Applicable only to RGC..15, RGC..25 and RGC..32 models
COPYRIGHT ©2026 Content subject to change. Download the PDF: https://gavazziautomation.com
**30**
15/05/2026 RGC DS ENG
Carlo Gavazzi Ltd.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →