RE8RA31BTQ
Analogue Timer, RE8, Off-Delay, 0.3 s, 30 s, 1 Ranges, 1 Changeover Relay
- Manufacturer: SCHNEIDER ELECTRIC
- Product type: Analogue Timers - DIN Rail
- Product Range:RE8 Series; Timer Functions:Off-Delay; Time Min:0.3s; Time Max:30s; No. of Timing Ranges:1Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:24V; Current Rating Nom
- Time Max: 30s
- Time Min: 0.3s
- Timer Output: 1 Changeover Relay
- Product Range: RE8
- Timer Functions: Off-Delay
- Current Rating Nom: 8A
- Supply Voltage Max: 24V
- No. of Timing Ranges: 1Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 40 |
| Price | 29.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product data sheet Characteristics RE8RA31BTQ industrial timing relay - 0.3..30 s - type C - 24 V AC/DC - 1 C/O ## Main |Main|| |---|---| |Range of product|Zelio Time| |Product or component|Optimum industrial timing relay| |type|| |Component name|RE8| |Time delay type|C| |Time delay range|0.3...30 s| |[Us] rated supply|24 V AC/DC, 50/60 Hz| |voltage|| |Sale per indivisible|10| |quantity|| |Complementary<br>Discrete output type<br>Contacts material<br>Width pitch dimension<br>Voltage range<br>Connections - terminals<br>Tightening torque<br>Setting accuracy of time delay<br>Repeat accuracy<br>Voltage drift<br>Temperature drift<br>Minimum pulse duration<br>Reset time<br>Maximum switching voltage<br>Mechanical durability<br>[Ith] conventional free air thermal current<br>[Ie] rated operational current<br>Minimum switching capacity<br>Input voltage<br>Maximum switching current<br>Input compatibility<br>Marking<br>Overvoltage category<br>[Ui] rated insulation voltage<br>Supply disconnection value<br>Operating position<br>Surge withstand<br>Power consumption in VA<br>Power consumption in W|Relay<br>90/10 silver nickel contacts<br>22.5 mm<br>0.9...1.1 Us<br>Screw terminals 2 x 1.5 mm², flexible cablewith cable end<br>Screw terminals 2 x 2.5 mm², flexible cablewithout cable end<br>0.6...1.1 N.m<br>+/- 20 % of full scale<br>< 1 %<br>< 2.5 %/V<br>< 0.2 %/°C<br>26 ms<br>50 ms<br>250 V<br>20000000 cycles<br>8 A<br><= 2 A at 24 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991<br><= 2 A at 24 V, DC-13 for 70 °C conforming to VDE 0660<br><= 3 A at 24 V, AC-15 for 70 °C conforming to IEC 60947-5-1/1991<br><= 3 A at 24 V, AC-15 for 70 °C conforming to VDE 0660<br><= 0.1 A at 250 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991<br><= 0.1 A at 250 V, DC-13 for 70 °C conforming to VDE 0660<br><= 0.2 A at 115 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991<br><= 0.2 A at 115 V, DC-13 for 70 °C conforming to VDE 0660<br>10 mA at 12 V<br>24 V (Y1)<br>10 mA (Y1)<br>2-wire sensors DC with leakage current < 1 mA, cable length: <= 50 m (Y1)<br>CE<br>III conforming to IEC 60664-1<br>250 V conforming to IEC<br>300 V conforming to CSA<br>> 0.1 Uc<br>Any position without derating factor<br>2 kV conforming to IEC 61000-4-5 level 3<br>0.7 VA at 24 V<br>0.5 W at 24 V| |---|---| 7/9/2011 1 |Terminal description|(15-16-18)OC_ON| |---|---| ||(A1-A2)CO| ||(Y1)UNUSED| |Height|78 mm| |Width|22.5 mm| |Depth|80 mm| |Product weight|0.11 kg| |Environment|| |Immunity to microbreaks|3 ms| |Standards|EN/IEC 61812-1| |Product certifications|CSA| ||GL| ||UL| |Ambient air temperature for storage|-40...85 °C| |Ambient air temperature for operation|-20...60 °C| |Relative humidity|15...85 % 3K3 conforming to IEC 60721-3-3| |Vibration resistance|0.35 mm 10...55 Hz conforming to IEC 60068-2-6| |Shock resistance|15 gn (duration = 11 ms conforming to IEC 60068-2-27| |IP degree of protection|IP20 (terminals)| ||IP50 (casing)| |Pollution degree|3 conforming to IEC 60664-1| |Dielectric test voltage|2.5 kV| |Non-dissipating shock wave|4.8 kV| |Resistance to electrostatic discharge|6 kV in contact conforming to IEC 61000-4-2 level 3| ||8 kV in air conforming to IEC 61000-4-2 level 3| |Resistance to electromagnetic fields|10 V/m conforming to IEC 61000-4-3 level 3| |Resistance to fast transients|2 kV conforming to IEC 61000-4-4 level 3| |Disturbance radiated/conducted|CISPR11 group 1- class A| ||CISPR22 - class A| |RoHS EUR status|Compliant| |RoHS EUR conformity date|0624| 2 Product data sheet Technical Description ## RE8RA31BTQ ## Function C: Timing After Opening of Control Contact ## Description After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. ## Function: 1 Output ## Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) ## Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/ 2 timed outputs R2 R2 The second output is instantaneous if the right position is selected inst. T Timing period Ta Adjustable On-delay Tr Adjustable Off-delay U Supply 3 Product data sheet Dimensions Drawings ## RE8RA31BTQ Width 22.5 mm ## Rail Mounting ## Screw Fixing 4 ## Product data sheet ## RE8RA31BTQ ## Connections and Schema ## Internal Wiring Diagram ## Recommended Application Wiring Diagram ## Control of Several Relays Control of several relays with a single external control contact The external control contact C may be an electronic control device, for example a true-wire sensor. In this case A1-A2= 24 Vdc and the control device can only control-up to a maximum of 4 relays. ## Connection of a 2-Wire Sensor Leakage current (open state) if < 1 mA. 5 Product data sheet Performance Curves ## RE8RA31BTQ ## Performance Curves ## A.C. Load Curve 1 Electrical durability of contacts on resistive loading millions of operating cycles - X Current broken in A - Y Millions of operating cycles ## A.C. Load Curve 2 Reduction factor k for inductive loads (applies to values taken from durability curve 1). - X Power factor on breaking (cos ϕ) - Y Reduction factor k Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore becomes:1.5 10[6] operating cycles x 0.6 = 900 000 operating cycles. ## D. C. Load Limit Curve X Current in A - Y Voltage in V - 1 L/R = 20 ms - 2 L/R with load protection diode 3 Resistive load 6
Updated at June 3, 2026
Schneider Electric is a recognized global leader in digital automation and energy management, dedicated to bridging progress and sustainability. By integrating world-leading process and energy technologies, they empower industries, infrastructure, and facilities to maximize efficiency and reliability. The company is renowned across the electronics and electrical sectors for manufacturing robust, innovative control and protection components that drive the digital transformation of industrial systems. Our comprehensive portfolio of Schneider Electric products strongly focuses on high-performance switching and automation control. We carry an extensive selection of relays, including hundreds of power relays, solid-state relays, contactors, and critical safety relays designed for demanding operational environments. For automation and process control applications, the range provides essential equipment such as motor starters, visual signal indicator units, process controllers, and versatile industrial switch accessories. To ensure the safety and integrity of electrical installations, we also supply a robust lineup of Schneider Electric circuit protection devices. This includes a wide array of thermal-magnetic circuit breakers, specialized fuse holders, and residual current devices. Supported by precision panel instrumentation, dependable AC/DC converters, and specialized DIN rail terminal blocks, our offering equips engineers with the critical components required for comprehensive industrial control and energy management solutions.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →