RC1V-AH-D48
PCB RELAY, SPST-NO, 16A, 48VDC, TH
- Manufacturer: IDEC
- Product type: Power Relays
- Contact Configuration:SPST-NO; Coil Voltage:48VDC; Contact Current:16A; Product Range:RC Series; Relay Mounting:Through Hole; Coil Type:Non Latching; Contact Voltag 79AK4006
- SVHC: No SVHC (15-Jan-2019)
- Coil Type: Non Latching
- Coil Voltage: 48VDC
- Product Range: RC Series
- Relay Mounting: Through Hole
- Coil Resistance: 5.36kohm
- Contact Current: 16A
- Relay Terminals: PC Pin
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 24V
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 4.14 € |
| Current stock | 10+ |
| Lead time | 30 days |
RC Series PCB Relays
## High capacity and compact, low-profile relays. SPDT, 16A and DPDT, 8A
See website for details on approvals and standards.
|RC series|Packagequantity: 20<br>Characteristics||
|---|---|---|
|Contact<br>configuration<br>Contact<br>capacity<br>Coil voltage<br>Part No.<br>SPST-NO<br>Basic<br>5V DC<br>RC1V-A-D5<br>12V DC<br>RC1V-A-D12<br>24V DC<br>RC1V-A-D24<br>48V DC<br>RC1V-A-D48<br>110V DC<br>RC1V-A-D110<br>SPDT<br>5V DC<br>RC1V-C-D5<br>12V DC<br>RC1V-C-D12<br>24V DC<br>RC1V-C-D24<br>48V DC<br>RC1V-C-D48<br>110V DC<br>RC1V-C-D110<br>SPST-NO<br>High<br>capacity<br>5V DC<br>RC1V-AH-D5<br>12V DC<br>RC1V-AH-D12<br>24V DC<br>RC1V-AH-D24<br>48V DC<br>RC1V-AH-D48<br>110V DC<br>RC1V-AH-D110<br>SPDT<br>5V DC<br>RC1V-CH-D5<br>12V DC<br>RC1V-CH-D12<br>24V DC<br>RC1V-CH-D24<br>48V DC<br>RC1V-CH-D48<br>110V DC<br>RC1V-CH-D110<br>Part No.<br>RC1V<br>Basic<br>RC1V<br>High capacity<br>RC2V<br>Basic<br>No. of Poles<br>1-pole<br>2-pole<br>Contact configuration<br>SPST-NO,SPDT<br>DPST-NO,DPDT<br>Contact material<br>AgSnO2<br>Movable: AgSnO2+Au-plated<br>Stationary: AgSnO2<br>Degree ofprotection<br>Flux-resistant type(RTII)<br>Contact resistance(*1)<br>100mΩ maximum<br>Operatingtime(*2)<br>15ms maximum<br>Release time(*2)<br>5ms maximum<br>Insulation resistance<br>1000MΩ minimum(500V DC megger)<br>Impulse<br>withstand<br>voltage<br>Between contact<br>circuit and coil<br>10,000V<br>Dielectric<br>strength<br>Between contact<br>circuit and coil<br>5000V AC, 1 minute<br>Between contacts<br>ofdifferent poles<br>–<br>3000V AC, 1 minute<br>Between contacts<br>ofthe same pole<br>1000V AC, 1 minute<br>Vibration<br>resistance<br>Operating extremes Frequency: 10 to 55Hz<br>Amplitude: 0.35mm<br>Frequency: 10 to 55Hz,<br>Amplitude 0.825mm<br>Damage limits<br>Frequency: 10 to 55Hz<br>Amplitude: 0.75mm<br>Frequency: 10 to 55Hz,<br>Amplitude 1.65mm<br>Shock<br>resistance<br>Operating extremes 100m/s2<br>Damage limits<br>1000m/s2<br>RC1V-AH:<br>~~a a~~<br>~~ee ~~ee<br>~~eeee~~<br>~~ee ee es~~<br>~~- eese ee~~<br>~~reeer~~<br>~~ee eee~~ ~~a~~<br>~~ee ee~~ ~~ee~~<br>~~ee ee~~ ~~es~~<br>-<br>~~——F——F |ff~~<br>~~es~~<br>~~ee~~<br>~~a ee~~<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~ee eee~~<br>~~es~~<br>~~eeee~~<br>~~Pp |---|~~<br>~~**e**s~~<br>~~a a ee~~<br>-<br>~~eee~~<br>~~_—~~<br>~~e~~|||
|DPST-NO<br>Basic<br>5V DC<br>RC2V-A-D5<br>12V DC<br>RC2V-A-D12<br>24V DC<br>RC2V-A-D24<br>48V DC<br>RC2V-A-D48<br>DPDT<br>5V DC<br>RC2V-C-D5<br>12V DC<br>RC2V-C-D12<br>24V DC<br>RC2V-C-D24<br>48V DC<br>RC2V-C-D48<br>110V DC<br>RC2V-C-D110<br>Electrical life<br>(rated load)<br>100,000 times<br>min.<br>(250V AC/<br>24V DC, 12A)<br>100,000 times min.<br>(250V AC/24V DC, 16A)<br>RC1V-CH:<br>5 million times min.<br>(250V AC, 16 A)<br>3 million times min.<br>(24V DC,16A)<br>5 million times min.<br>(250V AC/24V DC, 8A)<br>(operation frequency600 times/hour)<br>Mechanical life(no load)<br>20 million times min.(operatingfrequency: 18,000 timesper hour)<br>Operatingtemperature<br>-40 to +85˚C(no freezing)<br>-40 to +75˚C(no freezing)<br>Operatinghumidity<br>5 to 85%RH(no condensation)<br>Storage temperature<br>-40 to +85˚C(no freezing)<br>Operatinghumidity<br>5 to 85%RH(no condensation)<br>Weight(approx.)<br>13g<br>12g<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~fF~~<br>~~Oo~~<br>~~== ee~~<br>~~es a~~<br>~~a~~fs~~QaSV~~|||
||• Above values are initial values.||
||*1) Measured using 6V DC, 1A voltage drop method||
|Contact ratings|*2) Measured at the rated voltage (at 20°C), excluding contact bounce time.||
|Type<br>Allowable contact power<br>Rated load<br>Allowable<br>contactcurrent<br>Allowable<br>contact voltage<br>Minimum applicable load<br>(Referencevalue) (*3)<br>Resistive load<br>Voltage<br>Resistive load|||
|RC1V<br>Basic<br>High<br>capacity|3000VA AC<br>288W DC<br>250V AC<br>24V DC<br>12A<br>12A<br>12A<br>440V AC<br>300V DC<br>5V DC<br>100mA<br>4000VA AC<br>384W DC<br>250V AC<br>24V DC<br>16A<br>16A<br>16A||
|RC2V<br>Basic|2000VA AC<br>192W DC<br>250V AC<br>24V DC<br>8A<br>8A<br>8A<br>400V AC<br>300V DC<br>5V DC<br>10mA||
- *3) Minimum switching loads mentioned above are reference values. Reference values may vary according to switching frequencies, environmental conditions and expected reliability levels. Perform the confirmation test with the actual load before use.
- When the maximum current flow exceeds 10A, take into consideration the heat generated by the PCB wiring. Check the operation using the actual load.
1
RC Series PCB Relays
## Coil ratings
**==> picture [496 x 229] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating characteristics (against rated values at 20°C)<br>Rated current (mA) Coil resistance (Ω) Power<br>Type rated voltageCoil Code (at 20˚C)±10% (at 20˚C)±10% allowable voltageMaximum * pickup voltage Minimum Dropout voltage(initial value) consumption(approx.)<br>( 1) (initial value)<br>5V DC D5 81 62 12.3V<br>12V DC D12 33 360 29.4V 400mW<br>RC1V 24V DC D24 17 1440 58.8V 70% maximum<br>48V DC D48 9 5360 117.6V 430mW<br>110V DC D110 4 28,800 269.5V 420mW<br>5V DC D5 81 62 9.87V<br>12V DC D12 33 360 23.7V<br>400mW<br>RC2V-A 24V DC D24 17 1440 47.4V 75% maximum 10% minimum<br>48V DC D48 9 5760 94.8V<br>110V DC D110 – – – –<br>5V DC D5 106 47 8.7V<br>12V DC D12 44 270 21.0V<br>530mW<br>RC2V-C 24V DC D24 22 1100 42.0V 70% maximum<br>48V DC D48 11 4400 84.0V<br>110V DC D110 5 22,000 192.5V 550mW<br>**----- End of picture text -----**<br>
*1) The maximum allowable voltage is the maximum value of voltage that can be applied to the relay coil and not the continuous allowable value.
Dimensions Note: Terminal dimensions are dimensions before pre-soldering.
All dimensions in mm.
**==> picture [35 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC1V-A-D<br>**----- End of picture text -----**<br>
**==> picture [36 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC1V-C-D<br>**----- End of picture text -----**<br>
**==> picture [222 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
29 [±0.3]<br>ø0.45 0.3 0.5<br>(2.6) 20 3.5 0.9 0.9<br>2.6 7.5<br>4-Pre-solder<br>12.7 [±0.3]<br>±0.3<br>15.7<br>3.3<br>**----- End of picture text -----**<br>
**==> picture [224 x 422] intentionally omitted <==**
**----- Start of picture text -----**<br>
29 [±0.3]<br>ø0.45 0.5 0.3 0.5<br>3.5 3.5 0.9 0.9<br>(2.6) 20<br>2.6 7.5<br>5-Pre-solder<br>12.7 [±0.3]<br>RC1V-CH-D<br>29 [±0.3]<br>ø0.45 0.5 0.3 0.5<br>5 5 0.9 0.9<br>(2.6) 20<br>2.6 7.5<br>8-Pre-solder<br>12.7 [±0.3]<br>±0.3<br>15.7<br>3.3<br>±0.3<br>15.7<br>3.3<br>**----- End of picture text -----**<br>
**==> picture [40 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC1V-AH-D<br>**----- End of picture text -----**<br>
**==> picture [222 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
29 [±0.3]<br>ø0.45 0.3 0.5<br>(2.6) 20 5 0.9 0.9<br>2.6 7.5<br>6-Pre-solder<br>12.7 [±0.3]<br>±0.3<br>15.7<br>3.3<br>**----- End of picture text -----**<br>
2
RC Series PCB Relays
**==> picture [497 x 733] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC2V-A-D RC2V-C-D<br>29 [±0.3] 29 [±0.3]<br>0.9 0.4 0.4 0.9 0.4 0.4 0.4<br>(2.1) 20 5 0.3 1 (2.1) 20 5 5 0.3 1<br>7.5 7.5<br>6-Pre-solder 8-Pre-solder<br>12.8 [±0.3] 12.8 [±0.3]<br>PCB drilling layout (Bottom View) All dimensions in mm.<br>RC1V-A-D RC1V-C-D<br>(29) (29)<br>(2.6) 20 [±0.05] 3.5 [±0.05] (2.6) 20 [±0.05]<br>3.5 [±0.05] 3.5 [±0.05]<br>+0.1 +0.1<br>0 0<br>+0.1 +0.1<br>RC1V-AH-D RC1V-CH-D 0 0<br>(29) (29)<br>(2.6) 20 [±0.05] 5 [±0.05] (2.6) 20 [±0.05]<br>5 [±0.05] 5 [±0.05]<br>+0.1 +0.1<br>0 0<br>+0.1 +0.1<br>0 0<br>RC2V-A-D RC2V-C-D<br>(29) (29)<br>(2.1) 20 [±0.05] 5 [±0.05] (2.1) 20 [±0.05]<br>5 [±0.05] 5 [±0.05]<br>+0.1<br>0<br>+0.1<br>Internal connection (Bottom View) 0<br>RC1V-A-D RC1V-C-D RC1V-AH-D (*1)<br>5 (A1) 8 (14) 5 (A1) 6 (12) 8 (14) 5 (A1) 7 (11) 8 (14)<br>NO NC NO COM NO<br>COM COM COM NO<br>4 (A2) 2 (11) 4 (A2) (2) 11 4 (A2) 2 1<br>RC1V-CH-D (*1) RC2V-A-D RC2V-C-D<br>5 (A1) 6 (12) 7 (11) 8 (14) 5 (A1) 7 (11) 8 (14) 5 (A1) 6 (12) 7 (11) 8 (14)<br>NC COM NO COM NO NC COM NO<br>NC COM NO COM NO NC COM NO<br>4 (A2) 3 2 1 4 (A2) 2 (21) 1 (24) 4 (A2) 3 (22) 2 (21) 1 (24)<br>Note) IEC notation in ( ).<br>2-ø1 2-ø1.3<br>2-ø1 3-ø1.3<br>2-ø1 4-ø1.3<br>2-ø1 6-ø1.3<br>6-ø1.3<br>8-ø1.3<br>±0.3 ±0.3<br>16.5 16.5<br>3.3 3.3<br>)(2.6<br>)(2.6<br>±0.05 )<br>7.5 (12.7 ±0.05 )<br>7.5 (12.7<br>)(2.6 )(2.6<br>±0.057.5 )(12.7 ±0.05 )<br>7.5 (12.7<br>)(2.65 )2.65<br>(<br>±0.05 )<br>7.5 (12.8 ±0.057.5 )12.8<br>(<br>**----- End of picture text -----**<br>
- *1) Both #1 and #8 should be used and the pattern should be designed to short-circuit on the board.
3
RC Series PCB Relays
## Characteristics (Reference)
**==> picture [489 x 709] intentionally omitted <==**
**----- Start of picture text -----**<br>
Coil temperature rise<br>RC1V (basic) RC1V (high capacity) RC2V (basic)<br>100 100 100<br>90 90<br>80 80 80<br>16A<br>70 70 8A<br>60 12A 60 10A 60<br>50 50 5A<br>40 40 40<br>30 30 0A<br>0A 0A<br>20 20 20<br>10 10<br>00 0.2 0.4 0.6 0.8 1.0 1.2 00 0.2 0.4 0.6 0.8 1.0 1.2 0 0 0.2 0.4 0.6 0.8 1.0 1.2<br>Coil power (W) Coil power (W) Coil power (W)<br>Operating range<br>RC1V (basic) RC1V (high capacity) RC2V (basic)<br>2.5 2.5 2.2<br>2.0<br>2.0 0A 2.0 0A<br>1.8<br>12A 16A 0A<br>1.6<br>1.5 1.5<br>1.4 8A<br>1.2<br>1.0 Must operate voltage (hot coil) 1.0 Must operate voltage (hot coil)<br>Must operate voltage (hot coil)<br>1.0<br>M ust oper ate voltage (cool coil) M ust oper ate voltage (cool coil)<br>0.50 20 40 60 80 100 0.50 20 40 60 80 100 0.8 Must operate voltage (cool coil)<br>Ambient temperature (ºC) Ambient temperature (ºC) 0.6<br>0 20 40 60 80 100<br>Ambient temperature (ºC)<br>Electric life curves<br>RC1V (basic) RC1V-AH (high capacity) RC1V-CH (high capacity)<br>1000 1000 1000<br>250V AC resistive load 250V AC resistive load 250V AC resistive load<br>24V DC resistive load 24V DC resistive load<br>500 500 500 250V AC cos ø =0.7<br>250V AC cos ø =0.7 250V AC cos ø =0.7 24V DC resistive load<br>300 300 300<br>200 200 200 250V AC cos ø =0.4<br>24V DC L/R=7ms<br>100 100 100<br>50 50 50<br>24V DC L/R=7ms 24V DC L/R=7ms<br>30 30 30<br>20 250V AC cos ø =0.4 20 250V AC cos ø =0.4 20<br>24V DC L/R=15ms 24V DC L/R=15ms 24V DC L/R=15ms<br>10 0 3 6 9 12 10 0 2 4 6 8 10 12 14 16 18 20 10 0 2 4 6 8 10 12 14 16 18 20<br>Contact current (A) Contact current (A) Contact current (A)<br>RC2V (basic)<br>1000<br>500<br>200<br>100<br>50 250V AC/24V DC resistive load<br>250V AC cos ø =0.7<br>20<br>24V DCL/R=7ms<br>10<br>5<br>2 250V AC cos ø =0.4<br>1<br>0 1 2 3 4 5 6 7 8 9 10<br>Contact current (A)<br>Coil temperature rise (ºC)<br>Coil temperature rise (ºC)<br>Coil temperature rise (ºC)<br>Nominal voltage multiplying factor Nominal voltage multiplying factor<br>Nominal voltage multiplying factor<br>Life (×10 operations)3 Life (×10 operations)3 Life (×10 operations)3<br>Life (×10 operations)4<br>**----- End of picture text -----**<br>
**==> picture [45 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC1V (basic)<br>**----- End of picture text -----**<br>
## RC2V (basic)
4
RC Series PCB Relays
## Characteristics (Reference)
## Maximum operating frequency
RC1V (basic)
RC1V (high capacity)
RC2V (basic)
**==> picture [483 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
50 50 10<br>AC resistive<br>20 20 AC resistive<br>AC resistive 5<br>10 10<br>5 5<br>2<br>2 2<br>1<br>1 1<br>DC resistive<br>0.5 0.5 DC resistive 0.5<br>DC resistive<br>0.2 0.2<br>0.1 0.1 0.2<br>10 20 50 100 200 500 1000 10 20 50 100 200 500 1000<br>Contact voltage (V) Contact voltage (V)<br>10 20 50 100 200 500 1000<br>Contact voltage (V)<br>Contact current (A) Contact current (A) Contact current (A)<br>**----- End of picture text -----**<br>
## Instructions
- (1) Do not subject the relay to vibrations or shocks exceeding the rated values (vibration resistance and shock resistance). Abnormal vibration or shock may cause not only malfunction but also deformation or damage to the internal parts of the relay, which may result in malfunction.
- (2) Be sure to apply a square wave rated voltage to the coil. For other uses, confirm the operation characteristics with the actual device before use.
- (3) Avoid using the product in an atmosphere where silicone gas, sulfide gas, or organic gas exists. Also, note that the use of silicone resin around the relay may cause contact failure.
- (4) When using In low temperatures below 0°C, be careful of freezing. Freezing may cause adhering of moving parts, delay in operation, or ice between contacts, which may interfere with contact continuity.
- (5) When multiple relays are closely mounted on the same board, magnetic interference between relays and heat generation may affect the relay characteristics. Confirm that the individual relays operate under the operating conditions of the surrounding relays before use.
- (6) Precautions when mounting on PCB
- Hand soldering should be done quickly at 360˚C within 3 seconds.
- Auto-soldering: Pre-heat at below 120˚C within 90 seconds. Solder at 255˚C±5˚C within 5 seconds.
- Because the terminal part is filled with epoxy resin, do not excessively solder or bend the terminal. Otherwise, air tightness will degrade.
- Avoid the soldering iron from touching the relay cover or the epoxy filled terminal part.
- Use a non-corrosive rosin flux.
## Operation humidity range
**==> picture [235 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC1V RC2V<br>80<br>60<br>40<br>20<br>-40 -20 0 20 40 60 80 100<br>Ambient temperature (°C)<br>Relative humidity (%RH) Relative humidity (%RH)<br>**----- End of picture text -----**<br>
**==> picture [137 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
80<br>60<br>40<br>20<br>-40 -20 0 20 40 60 80 100<br>Ambient temperature (°C)<br>Relative humidity (%RH)<br>**----- End of picture text -----**<br>
## Storage humidity range
RC1V
**==> picture [138 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
80<br>60<br>40<br>20<br>-40 -20 0 20 40 60 80 100<br>Ambient temperature (°C)<br>Relative humidity (%RH)<br>**----- End of picture text -----**<br>
**==> picture [19 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
RC2V<br>**----- End of picture text -----**<br>
**==> picture [139 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
80<br>60<br>40<br>20<br>-40 -20 0 20 40 60 80 100<br>Ambient temperature (°C)<br>Relative humidity (%RH)<br>**----- End of picture text -----**<br>
5
RC Series PCB Relays
## Safety Precautions
- Turn off the power to the product before starting installation, removal, wiring, maintenance, or inspection. Failure to turn power off may cause electrical shock or fire.
- For wiring, use wires of proper size to meet voltage and current requirements. Tighten the terminal screws to the recommended tightening torque.
- Be sure to use the product within the rated specifications. Failure to turn power off may cause electrical shock or fire.
## Instructions
## 1. Driving Circuit for Relays
- (1) To make sure of correct relay operation, apply rated voltage to the relay coil.
- (2) Input voltage for DC coil
- A complete DC voltage is best for the coil power to make sure of stable operation. When using a power supply containing a ripple voltage, suppress the ripple factor within 5%. When power is supplied through a rectification circuit, relay operating characteristics, such as pickup voltage and dropout voltage, differ on the ripple factor. Connect a smoothing capacitor to check the characteristics, as shown below.
**==> picture [131 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Smoothing<br>Capacitor<br>+<br>– R Relay<br>Pulsation<br>Emin Emax Emean DC<br>Emax – Emin<br>Ripple Factor (%) × 100%<br>Emean<br>Emax = Maximum of pulsating current<br>Emin = Minimum of pulsating current<br>Emean= DC mean value<br>**----- End of picture text -----**<br>
- (3) Operating the relay in sync with an AC load
**==> picture [124 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
TE<br>R<br>Load<br>EAC<br>Vin<br>EAC<br>Vin<br>**----- End of picture text -----**<br>
If the relay operates in sync with the relay contact, the relay life may be reduced. If this is the case, select a relay in consideration of the required reliability for the load Or, make the relay turn on and off irrespective of the AC power phase or near the point where the AC phase crosses zero voltage.
- (4) Leakage current while relay is off
Incorrect Correct R TE R lo When driving an element at the same time as the relay operation, special consideration is needed for the circuit design. As shown in the incorrect circuit below, leakage current (Io) flows through the relay coil while the relay is off. Leakage current causes the coil release failure or adversely affects the vibration resistance and shock resistance. Design a circuit as shown in the correct example.
- (5) Surge suppression for transistor driving circuits When the relay coil is turned off, a high-voltage pulse is generated. Be sure to connect a diode to suppress the counter electromotive force. Then, the coil release time becomes slightly longer. To shorten the coil release time, connect a Zener diode between the collector and emitter of the controlling transistor. Select a Zener diode with a Zener voltage slightly higher than the power voltage.
**==> picture [84 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Counter emf<br>suppressing diode<br>+<br>– R Relay<br>**----- End of picture text -----**<br>
- (6) Counter-electromotive force diode model has polarity. Be sure to connect according to the diagram. Incorrect wiring may cause malfunction.
## 2.Protection for relay contacts
- (1) The contact ratings show maximum values. Make sure that these values are not exceeded even momentarily. When an inrush current flows through the load, the contact may become welded. If this is the case, connect a contact protection circuit, such as a current limiting resistor.
- (2) Contact protection circuit
When switching an inductive load, arcing causes carbides to form on the contacts, resulting in increased contact resistance. In consideration of contact reliability, contact life, and noise suppression, the use of a surge absorbing circuit is recommended. Note that the release time of the load becomes slightly longer. Check the operation using an actual load. Incorrect use of a contact protection circuit will adversely affect switching characteristics. Typical examples of contact protection circuits are shown in the following table.
**==> picture [199 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
This protection circuit can be used when the load<br>impedance is smaller than the RC impedance in<br>an AC load power circuit.<br>Power C R Ind. Load R: Resistor of approximately the same resistance value as the load<br>C: 0.1 to 1 μF<br>This protection circuit can be used for both AC<br>C and DC load power circuits.<br>Power R Ind. Load R: Resistor of approximately the same resistance value as the load<br>C: 0.1 to 1 μF<br>This protection circuit can be used for DC load<br>+ power circuits. Use a diode with the following ratings.<br>Power D Ind. Load Reverse withstand voltage:Power voltage of the load circuit × 10<br>– Forward current:<br>More than the load current<br>This protection circuit can be used for both AC<br>and DC load power circuits.<br>For a best result, when using on a power voltage<br>Power Ind. Load of 24 to 48V AC/DC, connect a varistor across<br>the load. When using on a power voltage of 100<br>to 240V AC/DC, connect a varistor across the<br>contacts.<br>RC<br>Diode<br>Varistor Varistor<br>**----- End of picture text -----**<br>
- (3) Do not use a contact protection circuit as shown below.
When the relay coil is turned off, a high-voltage pulse is generated.
**==> picture [229 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
This protection circuit is very Generally, switching a<br>effective in arc suppression when<br>opening the contacts. But, the DC inductive load is more<br>C Load capacitor is charged while the contacts are opened. When the difficult than switching<br>Power contacts are closed, the capacitor a DC resistive load.<br>is discharged through the contacts,<br>increasing the possibility of contact Using an appropriate<br>welding. arc suppressor will<br>This protection circuit is very improve the switching<br>PowerC Load effective in arc suppression when opening the contacts. But, when the contacts are closed, a current flows to charge the capacitor, characteristics of a DC inductive load.<br>causing contact welding.<br>**----- End of picture text -----**<br>
6
RC Series PCB Relays
## Instructions
## 3. PCB Mounting
- (1) When mounting the relays closely together, make sure that it does not affect other electric components. Do not use relays in the vicinity of he strong magnetic field as this may affect relay operation.
- (2) Instructions on PCB mounting
- Mounting on PCB with warpage may damage the copper foil or displace the solder if used for a long period of time or subjected to vibration. Furthermore, avoid installation methods that may cause warping, as this can affect the relay characteristics.
- (3) Mounting Direction
- Take into consideration the mounting direction in order to fully demonstrate the performance of the relay. Typical characteristics that are greatly affected by mounting orientation include shock resistance (shock noise characteristics), life span, and contact reliability.
- Ideally, the relay should be mounted so that the direction of movement of the movable iron piece is perpendicular to the direction of vibration/shock.
- When used with large loads (generally more than self-coil) that may cause arcing, contact debris may accumulate around the contacts and degrade the insulation resistance between circuits. In such cases, make sure that the relays are mounted in the standard mounting direction.
- Note: The standard mounting direction is usually when the contacts are on top and the coil on the bottom.
- It is not recommended to use a single relay for both large and small loads. When a large load is used, the generated contact debris may cause failure to maintain the cleanliness of the microload opening/closing contacts. Therefore, when using multi-pole relays, avoid mounting directions and terminal connections where the small load contact is positioned lower than the large load contact.
- (4) Mounting space
## 4 . Usage, transport, and storage conditions
- Condensation occurs when there is a sudden change in temperature under high temperature and high humidity conditions. The relay insulation may deteriorate due to condensation.
- Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C. This causes problems such as sticking of movable parts or delays in operation.
- Plastic parts may become brittle when used in low temperature and low humidity environments.
## 5. Other precautions
- (1) General notice
- To maintain the initial performance, do not drop or provide shock to the relay.
- The relay cover cannot be removed from the base during normal operation. To maintain the initial characteristics, do not remove the relay cover.
- Use the relay in environments free from condensation, dust, sulfur dioxide (SO2), and hydrogen sulfide (H2S).
- � The relay cannot be washed as it is not a sealed type. Also make sure that flux does not leak to the PCB and enter the relay. (Except RF2 RTII models)
- (2) Connecting outputs to electronic circuits
- When the output is connected to a load which responds very quickly, such as an electronic circuit, contact bouncing causes incorrect operation of the load. Take the following measures into
- Connect an integration circuit.
- Suppress the pulse voltage due to bouncing within the noise margin of the load.
- (3) UL- and CSA ratings may differ from the product ratings specified by IDEC depending on the certification organizations and local conditions.
- (4) Do not use relays in the vicinity of he strong magnetic field as this may affect relay operation.
- When installing a large number of relays close to each other, note the following:
- Note the ambient temperature of the relay. Close mounting of a large number of replays may generate abnormal heat due to mutual interference of heat. Leave enough space between the replays to avoid heat buildup. Check the minimum mounting space between the relays.
- When multiple PCBs with relays are mounted to a rack, the temperature may rise excessively. When mounting relays, leave enough space so that heat will not build up, and so that the relays’ ambient temperature remains within the specified operating temperature range.
7
RC Series PCB Relays
## Ordering Terms and Conditions
## Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read and agree to the terms and conditions before placing your order.
## 1. Notes on contents of Catalogs
- (1) Rated values, performance values, and specification values of IDEC products listed in this Catalog are values acquired under respective conditions in independent testing, and do not guarantee values gained in combined conditions.
- Also, durability varies depending on the usage environment and usage conditions.
- (2) Reference data and reference values listed in Catalogs are for reference purposes only, and do not guarantee that the product will always operate appropriately in that range.
- (3) The specifications / appearance and accessories of IDEC products listed in Catalogs are subject to change or termination of sales without notice, for improvement or other reasons.
- (4) The content of Catalogs is subject to change without notice.
## 2. Note on applications
- (1) If using IDEC products in combination with other products, confirm the applicable laws / regulations and standards.
- Also, confirm that IDEC products are compatible with your systems, machines, devices, and the like by using under the actual conditions. IDEC shall bear no liability whatsoever regarding the compatibility with IDEC products.
- (2) The usage examples and application examples listed in Catalogs are for reference purposes only. Therefore, when introducing a product, confirm the performance and safety of the instruments, devices, and the like before use. Furthermore, regarding these examples, IDEC does not grant license to use IDEC products to you, and IDEC offers no warranties regarding the ownership of intellectual property rights or non-infringement upon the intellectual property rights of third parties.
- (3) When using IDEC products, be cautious when implementing the following. i. Use of IDEC products with sufficient allowance for rating and performance
- ii. Safety design, including redundant design and malfunction prevention design that prevents other danger and damage even in the event that an IDEC product fails
- iii. Wiring and installation that ensures the IDEC product used in your system, machine, device, or the like can perform and function according to its specifications
- (4) Continuing to use an IDEC product even after the performance has deteriorated can result in abnormal heat, smoke, fires, and the like due to insulation deterioration or the like. Perform periodic maintenance for IDEC products and the systems, machines, devices, and the like in which they are used.
- (5) IDEC products are developed and manufactured as general-purpose products for general industrial products. They are not intended for use in the following applications, and in the event that you use an IDEC product for these applications, unless otherwise agreed upon between you and IDEC, IDEC shall provide no guarantees whatsoever regarding IDEC products.
- i. Use in applications that require a high degree of safety, including nuclear power control equipment, transportation equipment (railroads / airplanes / ships / vehicles / vehicle instruments, etc.), equipment for use in outer space, elevating equipment, medical instruments, safety devices, or any other equipment, instruments, or the like that could endanger life or human health
- ii. Use in applications that require a high degree of reliability, such as provision systems for gas / waterworks / electricity, etc., systems that operate continuously for 24 hours, and settlement systems
## 3. Inspections
We ask that you implement inspections for IDEC products you purchase without delay, as well as thoroughly keep in mind management/maintenance regarding handling of the product before and during the inspection.
## 4. Warranty
- (1) Warranty period
The warranty period for IDEC products shall be one (1) year after purchase or delivery to the specified location. However, this shall not apply in cases where there is a different specification in the Catalogs or there is another agreement in place between you and IDEC.
- (2) Warranty scope
Should a failure occur in an IDEC product during the above warranty period for reasons attributable to IDEC, then IDEC shall replace or repair that product, free of charge, at the purchase location / delivery location of the product, or an IDEC service base. However, failures caused by the following reasons shall be deemed outside the scope of this warranty.
- i. The product was handled or used deviating from the conditions / environment listed in the Catalogs
- ii. The failure was caused by reasons other than an IDEC product
- iii. Modification or repair was performed by a party other than IDEC iv. The failure was caused by a software program of a party other than IDEC
- v. The product was used outside of its original purpose
- vi. Replacement of maintenance parts, installation of accessories, or the like was not performed properly in accordance with the user’s manual and Catalogs
vii. The failure could not have been predicted with the scientific and technical standards at the time when the product was shipped from IDEC
- viii. The failure was due to other causes not attributable to IDEC (including cases of force majeure such as natural disasters and other disasters)
Furthermore, the warranty described here refers to a warranty on the IDEC product as a unit, and damages induced by the failure of an IDEC product are excluded from this warranty.
## 5. Limitation of liability
The warranty listed in this Agreement is the full and complete warranty for IDEC products, and IDEC shall bear no liability whatsoever regarding special damages, indirect damages, incidental damages, or passive damages that occurred due to an IDEC product.
## 6. Service scope
The prices of IDEC products do not include the cost of services, such as dispatching technicians. Therefore, separate fees are required in the following cases.
- (1) Instructions for installation / adjustment and accompaniment at test operation (including creating application software and testing operation, etc.)
- (2) Maintenance inspections, adjustments, and repairs
- (3) Technical instructions and technical training
- (4) Product tests or inspections specified by you
The above content assumes transactions and usage within your region. Please consult with an IDEC sales representative regarding transactions and usage outside of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC products sold outside your region.
- iii. Use in applications where the product may be handled or used deviating from the specifications or conditions / environment listed in the Catalogs, such as equipment used outdoors or applications in environments subject to chemical pollution or electromagnetic interference If you would like to use IDEC products in the above applications, be sure to consult with an IDEC sales representative.
**Head Office** 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan **USA** IDEC Corporation **Singapore** IDEC Izumi Asia Pte. Ltd. **EMEA** APEM SAS **Thailand** IDEC Asia (Thailand) Co., Ltd. **India** IDEC Controls India Private Ltd.
**China Taiwan**
## **www.idec.com**
IDEC (Shanghai) Corporation **Japan** IDEC Corporation IDEC Izumi (H.K.) Co., Ltd. IDEC Taiwan Corporation
**==> picture [96 x 33] intentionally omitted <==**
Specifications and other descriptions in this brochure are subject to change without notice. Information in this brochure is current as of January, 2023. 2023 IDEC Corporation, All Rights Reserved.
EP1802-0
Updated at June 4, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →