RACV04-12
LED Driver, 4 W, 12 VDC, 330 mA, Constant Voltage, 90 V
- Manufacturer: RECOM POWER
- Product type: AC / DC LED Power Supplies
- Output Power Max:4W; Output Voltage Max:12V; Output Current:330mA; LED Driver Mode:Constant Voltage; Input Voltage Min:90V; Input Voltage Max:264V; Product Range:RACV04 Series; SVHC:N
- SVHC: No SVHC (21-Jan-2025)
- Product Range: RACV04 Series
- Output Current: 330mA
- LED Driver Mode: Constant Voltage
- Output Power Max: 4W
- Input Voltage Max: 264V
- Input Voltage Min: 90V
- Output Voltage Max: 12VDC
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 5.16 € |
| Current stock | 100+ |
| Lead time | 30 days |
• 4W AC-DC class II LED power supply Features • 12V and 24V constant voltage output • Fully protected (OLP, SCP, OCP, OTP) • Low standby power, ErP conform LED • IP65 (suitable for dry and damp locations) • Low cost Driver • CE, CB, ENEC, CSA and UL8750 certified • Wired connections for independent or built-in use ee Description ~~a,~~ These constant voltage LED drivers have been designed for cost-sensitive applications. The SELV outputs are suitable for built-in power-supply LED luminaires. Their low profile design allows them to be invisibly built into furniture, discreetly mounted under shelves or integrated in space-restricted applications such as coving lighting, strip lighting or troffer lighting systems. The power supplies are short circuit and overload protected and come with a full 3-year warranty. ## **AC/DC Converter** ## **RACV04** **4 Watt Constant** \ **Voltage Single Output** Selection Guide EEE IL Part ~~a~~ Input Input Output Output Efficiency Output y é ffey C Number Voltage Range Current Voltage Current Range typ. Power max. ~~ee~~ [VAC] [mA] [VDC] [mA] [%] [W] Ggaf RACV04-12 90-264 100 12 0-330 75 4 RACV04-24 90-264 100 24 0-170 75 4 All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. **==> picture [21 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> ERP<br>compliant<br>**----- End of picture text -----**<br> ## Model Numbering RACV04- ___ nom. Output Power ~~=~~ | __ Output Current ## Specifications (measured @ ta= 25°C, 240VAC and rated load) |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS| |---|---|---|---|---| |Parameter|Condition|Min.|Typ.|Max.| |Input Voltage Range||90VAC|230VAC|264VAC| |Inrush Current||||11A| |Start-upTime||||500ms| |Input FrequencyRange||47Hz||63Hz| |No Load Power Consumption||||0.5W| |Power Factor|full load, 230VAC|||0.40| |Internal OperatingFrequency|full load||64kHz|| |Output Ripple Voltage(1)|12VDC<br>24VDC|||120mVp-p<br>240mVp-p| |Notes:<br>Note1: Measured at 20MHz BW using 0.1µF & 47µF parallel capacitor.||||| UL8750 Certified CSA C22.2 No. 250.13 Certified IEC/EN61347-1 Certified IEC/EN61347-2-13 Certified IEC62384 Certified EN55015 Compliant ENEC CB Report Note1: Measured at 20MHz BW using 0.1µF & 47µF parallel capacitor. REV.: 2/2019 L-1 **www.recom-power.com** ## **AC/DC Converter** ## **RACV04 Series** Specifications (measured @ Ta= 25°C, 240VAC and rated Iout) |REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---| |Parameter|Condition|Value| |Output Voltage Accuracy||±5% max.| |Line Regulation||5% max.| |Load Regulation||5% max.| ## PROTECTION |PROTECTION||| |---|---|---| |Parameter|Condition|Value| |Input Fuse|external fuse is recommended|0.22Wfusible resistor| |Open Circuit Protection(OCP)||auto recoveryafter fault condition is removed| |Over Load Protection(OLP)||auto recoveryafter fault condition is removed| |Over Voltage Protection(OVP)||auto recoveryafter fault condition is removed| |Over Temperature Protection(OTP)|110°C Tcase|auto recoveryafter fault condition is removed| |Isolation Voltage(2)|I/P to O/P|3.75kVAC / 1 minute| |Isolation Resistance||100MW| Notes: Note2: For repeat Hi-Pot testing, reduce the time and/or the test voltage Maximum loading of automatic circuit breakers @ 115VAC, 1Ohm, 90° phase angle and max. load @ 230VAC, 1Ohm, 90° phase angle and max. load |Circuit Breaker||Circuit Breaker Current|Circuit Breaker Current|Circuit Breaker Current|Circuit Breaker Current|||Circuit Breaker||Circuit Breaker Current|Circuit Breaker Current|Circuit Breaker Current|Circuit Breaker Current|| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Typ|10A||16A|20A||25A||Typ|10A||16A|20A||25A| |C|54||118|148||184||B|17||28|35||44| |||||||||C|27||59|74||92| ## ENVIRONMENTAL **==> picture [522 x 314] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Condition Value<br>Operating Temperature Range -20°C to +50°C<br>Maximum Case Temperature +79°C<br>Operating Altitude 2000m<br>Operating Humidity 5% to 85% RH, non condensing<br>IP Rating IP65<br>Pollution Degree PD2<br>Design Lifetime 30 x 10³ hours<br>Derating Graph<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>-20 -10 0 10 20 30 40 50 60<br>Ambient Temperature [°C]<br>Output Load [%]<br>**----- End of picture text -----**<br> REV.: 2/2019 L-2 **www.recom-power.com** **RACV04 Series** **AC/DC Converter** |SAFETY AND CERTIFICATIONS<br>~~|~~|SAFETY AND CERTIFICATIONS<br>~~|~~|SAFETY AND CERTIFICATIONS<br>~~|~~| |---|---|---| |Certificate Type<br>~~|~~<br>~~po~~<br>~~es~~|Report Number<br>~~|~~<br>~~Pp~~|Standard<br>~~|~~<br>~~Pp~~| |ETL Standard for LED Equipment for use in LightingProducts<br>~~po~~<br>~~es~~|160428123GZU-001<br>~~Pp~~<br>~~y=—~~|UL8750, 2nd Edition, 2015<br>~~Pp~~| |LED Equipment for LightingApplications<br>~~po~~<br>~~es~~<br>~~=~~||CSA C22.2 No. 250.13, 2014-07-01<br>~~Pp~~<br>~~y=—~~| |LampControlgear: General Requirments for Safety (LVD)<br>~~es~~<br>~~=~~|366911<br>~~y=—~~<br>~~po~~<br>~~po~~<br>~~pT~~<br>~~Po~~<br>~~po~~<br>~~PO~~<br>~~|~~|EN61347-1:2015<br>~~y=—~~| |LampControlgear: Particular Requirements for d.c. or a.c.(LVD)<br>~~=~~<br>~~po~~||EN61347-2-13:2014 +A1 2017<br>~~y=—~~<br>~~po~~| |LampControlgear: General Requirments for Safety (CB Scheme)<br>~~=~~<br>~~po~~<br>~~po~~||IEC61347-1:2015, 3rd Edition + A1:2017<br>~~y=—~~<br>~~po~~<br>~~po~~| |LampControlgear: Particular Requirements for d.c. or a.c.(CB Scheme)<br>~~=~~<br>~~po~~<br>~~po~~<br>~~pT~~||IEC61347-2-13:2014 2nd Edition +A1:2016<br>~~y=—~~<br>~~po~~<br>~~po~~<br>~~Po~~| |LampControlgear: General Requirments for Safety<br>~~=~~<br>~~po~~<br>~~pT~~<br>~~po~~||AS/NZS61347.1:2016<br>~~y=—~~<br>~~po~~<br>~~Po~~<br>~~po~~| |LampControlgear: Particular Requirements for d.c. or a.c.<br>~~=~~<br>~~pT~~<br>~~po~~<br>~~po~~<br>~~———— |~~||AS/NZS61347.2.13:2013<br>~~y=—~~<br>~~Po~~<br>~~po~~<br>~~PO~~| |LampControlgear General Requirments for Safety (ENEC)<br>~~= ~~<br>~~po~~<br>~~po~~<br>~~pT~~<br>~~———— |~~|366911-1<br> ~~y=—~~<br>~~po~~<br>~~PO~~<br>~~pT~~<br>~~pO~~<br>~~|~~|IEC61347-1:2015<br>~~y=—~~<br>~~po~~<br>~~PO~~<br>~~pO~~| |LampControlgear Particular Requirements for d.c. or a.c.(ENEC)<br>~~po~~<br>~~pT~~<br>~~———— |~~||EN61347-2-13:2014 + A1:2017<br>~~PO~~<br>~~pO~~| |D.C. or A.C. Controlgears for LED Performance Requirements (ENEC)<br>~~pT~~<br>~~———— |~~||EN62384:2006 + A1:2009<br>~~pO~~| |D.C. or A.C. Controlgears for LED Performance Requirements<br>~~———— |~~||IEC62384:2006,1st Edition +A1:2009| |EAC<br>~~———— |~~<br>~~a~~|RU-AT.49.09571<br>~~|~~<br>~~a~~|TP TC 004/2011<br>~~a~~| |RoHS2<br>~~———— |~~<br>~~a~~<br>~~a~~|LCS1606201548R<br>~~|~~<br>~~a~~<br>~~a~~|RoHS-2011/65/EU + AM-2015/863<br>~~a~~<br>~~a~~| |~~a~~||| |EMI Compliance<br>~~pT~~<br>~~pt~~|~~pT~~<br>~~po~~|Standard / Criterion<br>~~pT~~<br>~~po~~| |Equipment forgeneral LightingPurpose EMC ImmunityRequirements<br>~~pt~~<br>~~a~~|366910<br>~~po~~<br>~~a~~<br>~~po~~|EN61547: 2009<br>~~po~~<br>~~a~~| |Limits and methods of measurement of radio disturbance characteristics of electrical<br>lightingand similar equipment<br>~~pt~~<br>~~a~~<br>~~pt~~||EN55015:2013 + A1:2015<br>~~po~~<br>~~a~~<br>~~po~~| |Assessment of lightingequipment related to human exposure to electromagnetic fields<br>~~a~~<br>~~pt~~||EN62493: 2015<br>~~a~~<br>~~po~~| |ESD Electrostatic discharge immunity test<br>~~pt~~<br>~~a~~|Air: ±8, 4, 2kV<br>Contact: ±4, 2kV<br>~~po~~<br>~~a~~|EN61000-4-2: 2009, Criteria A<br>~~po~~<br>~~a~~| |Radiated, radio-frequency, electromagnetic field immunitytest<br>~~a~~<br>~~a~~|3V/m<br>~~a~~<br>~~a~~|EN61000-4-3: 2006 + A2:2010, Criteria A<br>~~a~~<br>~~a~~| |Fast Transient and Burst Immunity<br>~~a~~<br>~~a~~|AC Port: ±1kV<br>DC Port: ±0.5kV<br>~~a~~<br>~~a~~|EN61000-4-4: 2012, Criteria A<br>~~a~~<br>~~a~~| |Surge Immunity<br>~~a~~<br>~~a~~|AC Port: ±0.5kV<br>~~a~~<br>~~a~~|EN61000-4-5: 2014, Criteria A<br>~~a~~<br>~~a~~| |Immunityto conducted disturbances, induced byradio-frequencyfields<br>~~a~~<br>~~a~~|3V<br>~~a~~<br>~~a~~|EN61000-4-6: 2014, Criteria A<br>~~a~~<br>~~a~~| |Voltage Dips and Interuptions<br>~~a~~<br>~~a~~|>95% reduction, 10ms<br>30% reduction,200ms<br>~~a~~<br>~~a~~|EN61000-4-11, 2004, Criteria B<br>EN61000-4-11,2004,Criteria B<br>~~a~~<br>~~a~~| |Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase<br>~~DD~~|~~DD~~|EN61000-3-3: 2013 Clause 5<br>~~DD~~| |DIMENSION and PHYSICAL CHARACTERISTICS|DIMENSION and PHYSICAL CHARACTERISTICS|DIMENSION and PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|Case<br>Potting|Plastic (UL94 V-2)<br>Silicone(UL94 V-0)| |Package Dimension(LxWxH)||38.0 x 27.0 x 21.0mm| |Package Weight||40g| |continued on nextpage||| REV.: 2/2019 L-3 **www.recom-power.com** **RACV04 Series** **AC/DC Converter** **==> picture [525 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> es Specifications (measured @ Ta= 25°C, 240VAC and rated Iout)<br>**----- End of picture text -----**<br> **==> picture [449 x 375] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Dimensions<br>10±1 172±1 38.0<br>——— 1 —e<br>2<br>double insulation<br>tc<br>3<br>10.0<br>4<br>172±1 10±1<br>a— FC 48.0 SS 27.0<br>J Lo—<br>54.0 8.4<br>Wire/cable information<br># Function Wire color Type AWG<br>1 VAC in (N) blue UL-1007 18<br>2 VAC in (N) brown UL-1007 18<br>3 LED+ red UL-1007 18<br>4 LED- black UL-1007 18<br>tc= case temperature measuring point<br>FX= fixing centers<br>Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.25mm<br>18.0 FC 13.5<br>21.0<br>2.2<br>**----- End of picture text -----**<br> ## INSTALLATION and APPLICATION **==> picture [66 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>L N<br>**----- End of picture text -----**<br> **==> picture [20 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> LED+<br>LED-<br>**----- End of picture text -----**<br> ## PACKAGING INFORMATION |PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION| |---|---|---| |Parameter|Type|Value| |PackagingDimension(LxWxH)|Cardboard Box|290.0 x 86.0 x 76.0mm<br>10pcs| |PackagingQuantity||| |Storage Temperature Range||-20°C to +70°C| |Storage Humidity||5% - 85% RH| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 2/2019 L-4 **www.recom-power.com**
Updated at April 28, 2026
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →