Image not available
Illustrative purposes only
RACM30-24SER
PCB MOUNT AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 47.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Converter** ## Features - Medical certified 2MOPP module, BF ready - Class II installations (without FG) - IP68 waterproof encapsulation - Operation altitude certified up to 5000m ## Regulated Converter - No external components necessary - Energy Efficiency Level **VI** ## Description The RACM30-ER series comprises reliable and highly efficient power conversion modules in a potted IP68 waterproof encapsulation to withstand harsh operating conditions. With a certified operation up to 5000m altitude and less than 2”x2” of required board space, these modules are built to power compact applications in medical healthcare, household, sanitary, smart building, and automation appliances. For easy integration the series are covered by certifications for medical, household, and ITE safety standards and designed to pass class B limits by more than 6dB margin without the need for any external components. ## **RACM30-ER** ## **30 Watt Round** ## **Shape Single Output** ## Selection Guide |Part|Input|Output|Output|Efficiency| |---|---|---|---|---| |Number|Voltage Range|Voltage(1)|Current|typ.(2)| ||[VAC]|[VDC]|[A]|[%]| |RACM30-12SER(3)|90-264|12|2.5|88| |RACM30-24SER(3)|90-264|24|1.25|89.5| ## Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25°C ambient ## Model Numbering ## RACM30-__ SER[(3)] Output Power **S** ingle Output Voltage ## Notes: Note3: Other connection types on reqeuest **==> picture [94 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> C 1 R ) US<br>TEBA XEBA<br>SE ic<br>O ~<br>()<br>2. ws Y,<br>2MOPP<br>250VAC<br>**----- End of picture text -----**<br> IEC/EN60950-1 certified UL60950-1 certified ANSI/AAMI ES60601-1 certified IEC/EN60601-1 certified IEC/EN60335-1 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified IEC/EN60601-1-2 certified EN55024/32 certified EN55014-1 (-2) certified REV.: 3/2018 MED-1 **www.recom-power.com** **Series** ## **RACM30-ER** ## **AC/DC Converter** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) |BASIC CHARACTERISTICS<br>Parameter<br>Condition<br>Min.<br>Typ.<br>Max.<br>Internal Input Filter<br>Pi type<br>~~eT~~<br>~~Ce~~<br>~~ee~~| |---| |Input Voltage Range<br>90VAC<br>230VAC<br>264VAC<br>Input Current<br>115VAC<br>230VAC<br>1000mA<br>290mA<br>Inrush Current<br>115VAC<br>230VAC<br>60A<br>95A<br>No load Power Consumption<br>75mW<br>~~ee~~<br>~~ee es ee~~<br>~~eses es es~~| |Input FrequencyRange<br>47Hz<br>63Hz<br>~~re~~| |Minimum Load<br>0%| |Power Factor<br>0.55<br>Start-up Time<br>115VAC<br>230VAC<br>75ms<br>150ms<br>Rise Time<br>115VAC / 230VAC<br>10ms<br>Hold-up Time<br>115VAC<br>230VAC<br>15ms<br>55ms<br>Internal OperatingFrequency<br>100% load at nominal Vin<br>100kHz<br>Output Ripple and Noise<br>75mVp-p<br>~~re~~<br>~~eses~~<br>~~es es~~<br>~~ee~~<br>~~ee ee~~<br>~~ee ee~~<br>~~ee~~<br>~~Ceff~~| |Efficiency vs. Load| RACM30-12SER RACM30-24SER **==> picture [466 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>90 ee 90 | |lc<br>80 ee 80 ee<br>70 70<br>Pp<br>60 ee 60 Pf<br>50 Ee 50 PP<br>40 Ee 40 7 a ee ee<br>30 30<br>20 ‘ee 85VAC 20 Pe} odo fb 85VAC<br>115VAC 115VAC<br>10 230VAC 10 230VAC<br>0 poe} 264VAC 0 fos 264VAC<br>0 25 50 75 100 0 25 50 75 100<br>Output Load [%] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> |REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---| |Parameter|Condition|Value| |Output Accuracy||±3.0% max.| |Line Regulation|low line to high line|±1.0% max.| |Load Regulation|0% to 100% load|±1.0% max.| |Transient Response|100% load stepchange|±3.0% max.| |continued on nextpage||| REV.: 3/2018 MED-2 **www.recom-power.com** ## **RACM30-ER** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) Accuracy vs. Load (@ min Vin to max. Vin) RACM30-12SER RACM30-24SER +3.0 +3.0 +2.0 +2.0 +1.0 +1.0 ~~ee ee ee ee a~~ 0 0 ~~—~~ -1.0 -1.0 -2.0 -2.0 ~~ee —~~ -3.0 ~~a ee ee ee~~ -3.0 ~~— ===~~ 0 25 50 75 100 0 25 50 75 100 Output Load [%] Output Load [%] PROTECTIONS ~~| a~~ Parameter ~~G~~ Type Value ~~fe~~ Input Fuse internal (line & neutral) T2A, slow blow ~~Ce~~ Short Circuit Protection (SCP) continuous, auto recovery 12Vout 17VDC, Latch OFF Over Voltage Protection (OVP) 24Vout 35VDC, Latch OFF ~~aeG~~ Over Voltage Category (OVC) ~~ee~~ OVCII 90VAC 140% of nominal output current, auto recovery Over Current Protection (OCP) < 1 minute Hiccup Mode ~~a ee~~ 264VAC 170% of nominal output current, auto recovery Over Temperature Protection (OTP) 95°C ambient thermal shutdown, auto recovery ~~ee~~ Class of Equipment ~~O~~ Class II ~~ee~~ Isolation Voltage[(3)] I/P to O/P tested for 1 minute ~~O~~ 4.4kVAC ~~a~~ Insulation Grade reinforced ~~eG~~ Leakage Current 100µA max. ~~ne~~ Means of Protection 260VAC working voltage 2MOPP ~~a~~ Medical Device Classification ~~G~~ Type BF Notes: Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage ~~ee~~ ## ENVIRONMENTAL |ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL| |---|---|---|---| |Parameter|Condition||Value| |Operating Temperature Range|natural convection 0.1m/s|without derating<br>with derating|-20°C to +50°C<br>-20°C to +70°C| |Maximum Case Temperature|||+85°C| |OperatingAltitude|||5000m| |OperatingHumidity|non-condensing||95% RH max.| |Pollution Degree|||PD2| |MTBF|according to MIL-HDBK-<br>217F,G.B.|+25°C<br>+50°C|538 x 103hours<br>107 x 103hours| |Design Lifetime|E-Caplimitation||130 x 103hours| |continued on nextpage|||| continued on next page REV.: 3/2018 MED-3 **www.recom-power.com** ## **RACM30-ER** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) Derating Graph (@ Chamber and natural convection 0.1m/s) 100 ~~Lf | | | tt~~ 80 ~~TTTTTTN~~ 60 ~~EETT~~ ~~**T** AL~~ 50 ~~eee~~ 40 ~~r reer STEELE~~ 20 0 -20 LETT -10 0 10 20 TTT 30 40 50 ET 60 70 80 90 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS ~~ct a~~ Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety IEC60950-1:2005, 2nd Edition + Am2:2013 T223-0255/17 ~~a~~ (CB Scheme) EN60950-1:2006 + A2:2013 Information Technology Equipment, General Requirements for ~~a~~ T223-0255/17 UL60950-1, 2nd Edition:2014 ~~a~~ Safety CAN/CSA C22.2 No. 60950-1, 2nd Edition:2014 Medical Electric Equipment, General Requirements for Safety ~~a~~ T223-0254/17 IEC60601-1:2005, AM1:2012 ~~a~~ and Essential Performance (CB Scheme) EN60601-1:2006 + A12:2014 Medical Electric Equipment, General Requirements for Safety ~~a~~ T223-0254/17 CAN/CSA-C22.2 No. 60601-1:14, 3rd Edition 2014 and Essential Performance ANSI/AAMI ES60601-1:2005 ~~a~~ Household and similar electrical appliances - Safety ~~a~~ T211-0759/17 IEC60335-1:2010, 5th Edition + A1:2013 ~~a~~ Part 1: General requirements (CB Scheme) EN60335-1:2012 + A11:2014 Safety of power transformers, power supplies, reactors and IEC61558-1:2005, 2nd Edition + A1:2009 similar products for supply voltages up to 1100V EN61558-1:2005 + A1:2009 Safety of transformers, reactors, power supply units and similar T211-0760/17 IEC61558-2-16:2009, 1st Edition + A1:2013 products for supply voltages up to 1100 V - Part 2-16: Particular EN61558-2-16:2009 + A1:2013 ~~oo~~ requirements and tests for switch mode power supply units ~~a~~ EAC RU-AT.49.09571 TP TC 004/2011 TP TC 004/2011 ~~ee a~~ RoHs 2 (2+) RoHs 10/10, AM2015 ~~a~~ EMC Compliance (Medical) ~~G~~ Condition Standard / Criterion Medical electrical equipment Part 1-2: Electromagnetic disturEN60601-1-2:2015 ~~a~~ bances – Requirements and tests ~~a DO~~ ESD Electrostatic discharge immunity test Air ±2, 4, 8, 15kV; Contact ±8kV IEC61000-4-2:2008, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 10V/m (80 - 2700MHz) IEC61000-4-3:2006 + A2:2010, Criteria A 27V/m (385MHz), 28V/m (450MHz), 9V/m (710, Radiated, radio-frequency, electromagnetic field immunity test 745, 780MHz), 28V/m 1720, 1845, 1970, IEC61000-4-3:2006 + A2:2010, Criteria A (table 9) 2450MHz), 9V/m (5240, 5500, 5785MHz) ~~i aree~~ 28V/m (800-960MHz) IEC61000-4-3:2006 + A2:2010, Criteria B ~~eee~~[(4)] ~~DD~~ Fast Transient and Burst Immunity AC Power Port: ±2.0kV IEC61000-4-4:2012, Criteria A ~~DD~~ Surge Immunity AC Power Port: L-N ±0.5, 1.0kV IEC61000-4-5:2005, Criteria A Notes: Note4: Output voltage doesn´t meet specified output accuracy continued on next page REV.: 3/2018 MED-4 **www.recom-power.com** **Series** ## **RACM30-ER** ## **AC/DC Converter** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) |EMC Compliance(Medical)<br>~~a~~|Condition<br>~~a~~<br>~~ee~~|Standard / Criterion<br>~~a~~| |---|---|---| |Immunity to conducted disturbances, induced by radio-frequency fields<br>~~a~~<br>~~ee~~|AC Power Port 6V<br>DC Output Port 6V<br>~~a~~<br>~~ee~~<br>~~ee~~|IEC61000-4-6:2013, Criteria A<br>~~a~~<br>~~ee~~| |Power Magnetic Field Immunity<br>~~ee~~<br>~~a~~|50Hz, 30A/m<br>~~ee~~<br>~~ee~~<br>~~a~~|IEC61000-4-8:2009, Criteria A<br>~~ee~~<br>~~a~~| |Voltage Dips and Interruptions<br>~~a~~<br>~~oo~~|~~a~~<br>~~oo~~|IEC61000-4-11:2004<br>~~a~~<br>~~oo~~| |~~oo~~<br>~~a~~||| |EMC Compliance(Household)<br>~~a~~|Condition<br>~~a~~|Standard / Criterion<br>~~a~~| |Electromagnetic compatibilityof multimedia equipment – Emission Requirements<br>~~a~~<br>~~a~~|~~a~~<br>~~a~~|EN55014-1:2006 + A2:2011<br>~~a~~<br>~~a~~| |Information technology equipment - Immunity characteristics - Limits and<br>methods of measurement<br>~~a~~<br>~~es~~|~~a~~<br>~~es~~|EN55014-2:1997 + A2:2008<br>~~a~~<br>~~es~~| |ESD Electrostatic discharge immunitytest<br>~~a~~|Air ±8kV; Contact ±4kV<br>~~a~~|EN61000-4-2:2009, Criteria A<br>~~a~~| |Radiated, radio-frequency, electromagnetic field immunitytest<br>~~a~~<br>~~a~~|3V/m(80 - 1000MHz)<br>~~a~~<br>~~a~~<br>~~ee~~|EN61000-4-3:2006 + A2:2010, Criteria A<br>~~a~~<br>~~a~~| |Fast Transient and Burst Immunity<br>~~a~~<br>~~a~~|AC Power Port: ±1.0kV<br>DC Power Port ±0.5kV<br>~~a~~<br>~~a~~<br>~~ee~~|EN61000-4-4:2012, Criteria A<br>~~a~~<br>~~a~~| |Surge Immunity<br>~~a~~<br>~~a~~|AC Power Port: L-N ±1kV<br>~~a~~<br>~~ee~~<br>~~a~~<br>~~ee~~|EN61000-4-5:2014, Criteria A<br>~~a~~<br>~~a~~| |Immunity to conducted disturbances, induced by radio-frequency fields<br>~~a~~<br>~~ee~~|AC Power Port 3V<br>DC Power Port 1V<br>~~a~~<br>~~ee~~<br>~~ee~~|EN61000-4-6:2014, Criteria A<br>~~a~~<br>~~ee~~| |Voltage Dips and Interruptions<br>~~ee~~<br>~~a~~|~~ee~~<br>~~ee~~<br>~~a~~|EN61000-4-11:2004<br>~~ee~~<br>~~a~~| |~~a~~<br>~~a~~||| |EMC Compliance(Multimedia)<br>~~a~~|Condition<br>~~a~~|Standard / Criterion<br>~~a~~| |Electromagnetic compatibilityof multimedia equipment – Emission Requirements<br>~~a~~<br>~~a~~|~~a~~<br>~~a~~<br>~~ee~~|EN55032:2012, Class B<br>~~a~~<br>~~a~~| |Information technology equipment - Immunity characteristics - Limits and meth-<br>ods of measurement<br>~~a~~<br>~~a~~|~~a~~<br>~~a~~<br>~~ee~~|EN55024:2010<br>~~a~~<br>~~a~~| |ESD Electrostatic discharge immunitytest<br>~~a~~<br>~~a~~|Air ±2, 4, 8kV; Contact ±4kV<br>~~a~~<br>~~ee~~<br>~~a~~|EN61000-4-2:2009, Criteria A<br>~~a~~<br>~~a~~| |Radiated, radio-frequency, electromagnetic field immunitytest<br>~~a~~|3V/m(80 - 1000MHz)<br>~~a~~|EN61000-4-3:2006 + A2:2010 , Criteria A<br>~~a~~| |Fast Transient and Burst Immunity<br>~~a~~|AC Power Port: ±1.0kV<br>~~a~~|EN61000-4-4:2004, Criteria A<br>~~a~~| |Surge Immunity<br>~~a~~|AC Power Port: L-N ±0.5, 1.0kV<br>~~a~~<br>~~ee~~|EN61000-4-5:2006, Criteria A<br>~~a~~| |Immunity to conducted disturbances, induced by radio-frequency fields<br>~~ee~~|AC Power Port 3V<br>DC Power Port 3V<br>~~ee~~<br>~~ee~~|EN61000-4-6:2009, Criteria A<br>~~ee~~| |Power Magnetic Field Immunity<br>~~ee~~<br>~~ee~~|50Hz, 60Hz, 1A/m<br>~~ee~~<br>~~ee~~<br>~~ee~~|EN61000-4-8:2010, Criteria A<br>~~ee~~<br>~~ee~~| |Voltage Dips and Interruptions<br>~~ee~~|~~ee~~|EN61000-4-11:2004<br>~~ee~~| |Limits of Voltage Fluctuations & Flicker<br>~~ee~~<br>~~a~~|~~ee~~<br>~~a~~|EN61000-3-3:2013<br>~~ee~~<br>~~a~~| |~~a~~||| |EMC Compliance(Generic Standards)<br>~~a~~|Condition<br>~~a~~<br>~~ee~~|Standard / Criterion<br>~~a~~| |Generic standards – Immunity standard for residential, commercial and light-<br>industrial environments<br>~~ee~~|~~ee~~<br>~~ee~~|EN61000-6-1:2007<br>~~ee~~| |Generic standards – Immunity standard for industrial environments<br>~~ee~~<br>~~a~~|~~ee~~<br>~~ee~~<br>~~a~~<br>~~ee~~|EN61000-6-2:2005<br>~~ee~~<br>~~a~~| |Generic standards – Emission standard for residential, commercial and light-<br>industrial environments<br>~~a~~<br>~~ee~~|~~a~~<br>~~ee~~<br>~~ee~~|EN61000-6-3:2007 + A1:2011<br>~~a~~<br>~~ee~~| |DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|Case<br>Potting<br>PCB|non-conductive black plastic, (UL94V-0)<br>polyurethane, (UL94V-0)<br>FR4, (UL94V-0)| |Package Dimension(LxWxH)||53.0 x 51.0 x 33.5mm| |Package Weight||128gmax.| |continued on nextpage||| REV.: 3/2018 MED-5 **www.recom-power.com** **Series** ## **RACM30-ER** ## **AC/DC Converter** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) **==> picture [520 x 630] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing (mm) =<br>FC 12.5<br>tc<br>embossed logo<br>Ø 3.2<br>a, FC 12.5<br>53.0<br>2.0°<br>a C1<br>0.88 ±0.01 a 0.60 ±0.02<br>FC 25.0<br>Pin Connections<br>2.00 0.08 [+0.03][-0] Pin # Single<br> 1 +Vout<br>2 knurled pins 2 -Vout<br>1 6.10 3 VAC in (N)<br>12.0 4 VAC in (L)<br>Bottom View<br>tc= case temperature measuring point<br>FC = fixing centers<br>Tolerance: xx.x= ±0.5mm<br>7.10 xx.xx= ±0.25mm<br>4 3<br>Max. tightening torque fixing screws: 0.3Nm<br>eye<br>15.00<br>PACKAGING INFORMATION<br>Parameter Type Value<br>Packaging Dimension (LxWxH) carton 310.0 x 220.0 x 100.0mm<br>Packaging Quantity 10pcs<br>Storage Temperature Range -30°C to +80°C<br>Storage Humidtiy non-condensing 95% RH max.<br>57.1<br>FC 20.5<br>0<br>1.<br>5<br>FC 20.5<br>33.5<br>3.5<br>40.33<br>36.60 31.60 FC 41.0<br>**----- End of picture text -----**<br> The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 3/2018 MED-6 **www.recom-power.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →