- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 87.9 € |
| Current stock | 10+ |
| Lead time | 30 days |
• 160W baseplate-cooled, fan-less operation Features • 230W peak power or forced air rating • Universal AC input range (80~264VAC) **AC/DC Converter** • Standby power consumption <0.5W Regulated • Wide operating temperature range (-40°C to +80°C) • Household, ITE and medically 2MOPP certified Converter **RACM230-G** • Operating altitude up to 5000m ee ~~— a~~ Description **230 Watt** NEAR The RACM230-G Series is designed to support up to 160 watts continuous output power without fan **4” x 2” 3** cooling. The compact 4”x2” baseplate design enables direct heat dissipation through metal housings in the application. Up to 230 watts are available to drive dynamic loads for several seconds of peak power or with forced air for even longer time frames. A smart fan output is on board as standard. A wide input **Open Frame or** range of 80 to 264VAC, up to 5000m operating altitude, 4kVAC isolation and international safety agency certifications make the series worldwide compliant for medical 2 MOPP, household and industrial ITE **Enclosed** applications. **Open Frame or Enclosed Single Output** ## Selection Guide |Part|Input|Nom. Output|Max. Output|Efficiency| |---|---|---|---|---| |Number|Voltage Range|Voltage|Current(1)|typ.(3)| |RACM230-12SG(4)<br>~~OT~~|[VAC]<br>80-264|[VDC]<br>12|[A]<br>19.17(2)|[%]<br>91| |RACM230-24SG(4)|80-264|24|9.58|92| |RACM230-36SG(4)|80-264|36|6.39|92| |RACM230-48SG(4)|80-264|48|4.80|92| |RACM230-54SG(4)|80-264|54|4.26|92| Notes: ~~OTT~~ Note1: With forced air cooling (2.5m/s) + conduction cooling + refer to _“Derating Graph”_ Note2: Refer to _“Peak Load Capability”_ graph Note3: Efficiency is tested at nominal input and full load at +25°C ambient ## Model Numbering RACM230-__ SG/ENC max. Output Power _“Case Option[(4)] ”_ nom. Output Voltage ~~=a~~ **S** ingle Notes: Note4: without suffix standard open frame version add suffix “/ENC” for enclosed version (MOQ: 1000pcs) Ordering Examples: RACM230-24SG 24Vout Single open frame RACM230-48SG/ENC 24Vout Single enclosed **==> picture [129 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> RoHScompliant10 from 102+ REACHcompliant ERPLOT6 compliant<br>€<br>CERTIFIED<br>EN-60335-1<br>E314885<br>2MOPP<br>250VAC<br>E<br>T T<br>O O<br>i<br>N N<br>a<br>N P N P<br>C C<br>S<br>l<br>V<br>R<br>V<br>R<br>H<br>A A<br>n<br>E<br>O<br>E<br>I O I<br>M M<br>p<br>L L<br>U<br>R R<br>D D<br>O<br>P P<br>c<br>O T O T<br>U U<br>p<br>O<br>C<br>M<br>E E<br>C C<br>L<br>e<br>R E R<br>T O T<br>R<br>s<br>S<br>S<br>S<br>S C<br>D<br>**----- End of picture text -----**<br> ANSI/AAMI ES60601-1 (ed 3.1) (“/OF” version) CSA/CAN 22.2 60601-1-14 (ed 3.1) certified IEC/EN60601-1 (ed 3.1) (“/OF” version) certified IEC/EN62368-1 certified EN60335-1 certified EN62233 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified EN55032 compliant EN55035 compliant CB Report REV.: 3/2021 MED-1 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, 230VAC rated load unless otherwise stated) |BASIC CHARACTERISTICS|||||||| |---|---|---|---|---|---|---|---| |Parameter|||Condition||Min.|Typ.|Max.| |Nom. Input Voltage|||||100VAC||240VAC| |Input Voltage Range(5)|||||80VAC<br>120VDC|230VAC|264VAC<br>370VDC| |Input Current|||115VAC<br>230VAC||||3A<br>1.1A| |Inrush Current|||115VAC<br>230VAC||||40A<br>60A| |No load Power Consumption||||||300mW|500mW| |Input FrequencyRange|||AC input||47Hz|50Hz|63Hz| |ErP Lot 6 Standby Mode Conformity<br>(Output Load Capability)||Input Power= 1W|||||300mW| ||||12Vout||11.4VDC||12.6VDC| ||||24Vout||22.8VDC||25.2VDC| |Output Voltage Adjustability(6)|||36Vout||34.2VDC||37.8VDC| ||||48Vout||45.6VDC||50.4VDC| ||||54Vout||51.3VDC||56.0VDC| |Minimum Load|||||0%||| |Power Factor|||115VAC<br>230VAC||0.98<br>0.95|0.99<br>0.97|| |Start-upTime||115/230VAC||||0.5s|| |Rise Time||||||10ms|| |||||230W||8ms|| |Hold-up Time|115/230VAC|||200W<br>160W||10ms<br>16ms|| |||||130W||25ms|| |Output Ripple and Noise(7)||20MHz BW @ +25°C||||1% of Vout nom. max.|| Notes: Note5: The products were submitted for safety files at AC-input operation. For DC-input make sure that sufficient fuses are used Note6: By trimming up, decrease output current to avoid exceeding rated output power. By trimming down, do not exceed maximum continuous output current. If enclosed version is used, please remove cover, to use trim function. Note7: Measurements are made with a 12“ twisted pair-wire terminated with a 0.1µF and 10µF parallel capacitor ## Efficiency vs. Load 24V to 54V models 12V model **==> picture [489 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>110VAC 110VAC<br>10 10<br>230VAC 230VAC<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>continued on next page<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> REV.: 3/2021 PA-2 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) |REGULATIONS|||| |---|---|---|---| |Parameter||Condition|Value| |Output Accuracy|||±1.0% typ.| |Line Regulation||low line to high line, full load|±0.5% typ.| |Load Regulation(8)||10% to 100% load|0.5% typ.| ||Notes:<br>Note8: Operation below 10% load will not harm the converter, but specifcations may not be met||| |FAN OUTPUT|FAN OUTPUT|FAN OUTPUT|FAN OUTPUT|FAN OUTPUT|FAN OUTPUT| |---|---|---|---|---|---| |Parameter|Condition||Min.|Typ.|Max.| |Output Current|@50°C|continuous|||500mA| |Output Voltage||||12VDC|| |Ambient Temperature|full load||||50°C| |Short Circuit Protection(SCP)|||none||| |Over Current Protection(OCP)|||none||| |PROTECTIONS|PROTECTIONS|PROTECTIONS||||| |---|---|---|---|---|---|---| |Parameter|||Type|||Value| |Internal Input Fuse(9)|||line and neutral|||2x T6.3A, slow blow type| |Short Circuit Protection(SCP)||||||hiccupmode, auto recovery| |Over Voltage Protection(OVP)||||||105% - 150%, latch off mode| |Over Load Protection(OLP)||||||105% - 200%(150% typ.); hiccupmode auto recovery| |Over Voltage Category (OVC)||||||OVCII| |Isolation Voltage(safetycertifed)(10)|||I/P to O/P||1 minute|4kVAC| |Isolation Resistance||||||10MΩmin.| |Insulation Grade||||||reinforced| |Leakage Current||||||0.3mA max.| |Means of Protection|||250VAC working voltage|||2MOPP| |||Notes:||||| |||||||| |ENVIRONMENTAL||||||| |Parameter|||Condition|||Value| |OperatingTemperature Range|||refer to derating graphs|||-40°C to +80°C| |Temperature Coeffcient||||||±0.05%/K| |OperatingAltitude(11)||||||5000m| |OperatingHumidity|||non-condensing|||5% - 90% RH max.| |Pollution Degree||||||PD2| |MTBF|||according to<br>MIL-HDBK-217F, G.B.|+25°C (forced air cooling)<br>+50°C(forced air cooling)||200 x 103hours<br>60 x 103hours| ||continued on nextpage<br>Notes:<br>Note11: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.<br>Please contact RECOM tech support for advice.|||||| REV.: 3/2021 MED-3 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) **==> picture [235 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> Derating Graph<br>(@ 2.5m/s airflow + conduction cooling)<br>12V model<br>240<br>220<br>200<br>167 180<br>160<br>150<br>140<br>120<br>100<br>80<br>60 100VAC<br>40 115VAC<br>25 240VAC<br>20<br>0<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90<br>Ambient Temperature [°C]<br>Output Load [W]<br>**----- End of picture text -----**<br> **==> picture [201 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> others<br>240<br>230<br>220<br>207<br>200<br>186<br>180<br>160<br>140<br>120<br>100<br>80<br>50 60 100VAC<br>45 40 115VAC<br>240VAC<br>20<br>0<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90<br>45<br>Ambient Temperature [°C]<br>Output Load [W]<br>**----- End of picture text -----**<br> ## Derating Graph (@ natural convection + conduction cooling) **==> picture [452 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> 12V model others<br>170 170<br>160 160<br>150 150<br>144 144<br>140 140<br>130 130<br>120 120<br>110 110<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 100VAC 40 100VAC<br>35<br>30 115VAC 30 115VAC<br>20 240VAC 20 240VAC<br>10 10<br>0 0<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90<br>25<br>Ambient Temperature [°C] Ambient Temperature [°C]<br>Output Load [W] Output Load [W]<br>**----- End of picture text -----**<br> Derating Graph (@ natural convection) **==> picture [218 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 12V model<br>140<br>130<br>117 [120]<br>110<br>105<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30 100VAC<br>115VAC<br>20<br>15 240VAC<br>10<br>0<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90<br>Ambient Temperature [°C]<br>Convection Cooling:<br><0.1m/s = still air<br>0.1 - 0.2m/s = natural convection<br>Output Load [W]<br>**----- End of picture text -----**<br> **==> picture [201 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> others<br>140<br>130<br>120<br>117<br>110<br>105<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30 100VAC<br>25 115VAC<br>20<br>240VAC<br>10<br>0<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90<br>Ambient Temperature [°C]<br>Output Load [W]<br>**----- End of picture text -----**<br> Conduction Cooling: ground plane ref.: 2mm alloy; size A4 REV.: 3/2021 MED-4 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) ## Peak Load Capability ## Calculation Pout [W] Pnom = nom. output power [W] PP = peak output power (≤230W) [W] Pr = recovery output power [W] Pnom x (t1 + t2) - (PP x t1) Pp t1 = peak time set (10s max.) [s] Pr = t2 x k t2 = recovery time (min. 4 x t1) [s] k = safety factor 1.7 [ ] Pnom Practical Example (RACM230-12SG):-12SG):12SG): Pr Take the RACM230-12SG at 230VAC input Voltage and full load at TAMB= 25°C (160W) with AMB= 25°C (160W) with = 25°C (160W) with conduction cooling. 0 Time [s] t1 t2 ## Practical Example (RACM230-12SG):-12SG):12SG): Take the RACM230-12SG at 230VAC input Voltage and full load at TAMB= 25°C (160W) with AMB= 25°C (160W) with = 25°C (160W) with conduction cooling. Pnom. = refer to derating graphs (160W) PP = 230W t1 = 1s Pr = 160 x (1 + 40) - (230 x 1)40 x 1.7 = 93W t2 =[40s] k = 1.7 |SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|| |---|---|---| |Certifcate Type(Safety)|Report Number|Standard| |Audio/video, information and communication technologyequipment - Safetyrequirements|SA1903063L01001|IEC62368-1:2014 2nd Edition| |Audio/video, information and communication technologyequipment - Safetyrequirements(LVD)||EN62368-1:2014 + A11:2017| |Audio/video, information and communication technologyequipment - Safetyrequirements(CB)|211-700882-000|IEC62368-1:2014, 2nd Edition| |Audio/video, information and communication technologyequipment - Safetyrequirements|SA1903063L01001|EN62368-1:2014 + A11:2017| |Household and similar electrical appliances - Safety- Part 1: General requirements|SA0903063L02001|EN60335-1:2012 + A13:2017| |Measurement methods for electromagnetic felds of household appliances and similar<br>apparatus with regard to human exposure||EN62233:2008| |Medical Electric Equipment, General Requirements for Safety and Essential Performance|E314885<br>(“/OF” Version)|ANSI/AAMI ES60601-1:2005 + A2:2010/<br>(R)2012<br>CAN/CSA-C22.2 No. 6060-1:14, 3rd Edition| |Medical Electric Equipment, General Requirements for Safetyand Essential Performance(CB)|E314885|IEC60601-1:2005, 3rd Edition + AM1:2012| |Medical Electric Equipment, General Requirements for Safetyand Essential Performance||EN60601-1:2006 + A1:2013| |Safety of power transformers, power supplies, reactors and similar products -<br>Part 1: General requirements and tests|211-700883-000|IEC61558-1:2005, 2nd Edition + A1:2009<br>EN61558-1:2005 + A1:2009| |Safety of transformers, reactors, power supply units and similar products for supply<br>voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode<br>power supply units and transformers for switch mode power supply units (CB)|211-700883-000|IEC61558-2-16:2009, 1st Edition + A1:2013| |Safety of transformers, reactors, power supply units and similar products for supply<br>voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode<br>power supply units and transformers for switch mode power supply units (LVD)|211-700883-000|EN61558-2-16:2009 + A1:2013| |RoHS2||RoHS 2011/65/EU + AM2015/863| |continued on nextpage||| continued on next page REV.: 3/2021 MED-5 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) |EMC Compliance|Condition|Standard / Criterion| |---|---|---| |Electromagnetic compatibilityof multimedia equipment - Emission requirements|without external flter|EN55032:2015, Class B| |Electromagnetic compatibilityof multimedia equipment - Immunityrequirements||EN55035:2017| |Information technology equipment - Immunity characteristics - Limits and methods of<br>measurement||EN55024:2010 + A1:2015| |ESD Electrostatic discharge immunity test|Air: ±8kV; Contact ±4kV|IEC61000-4-2:2008, Criteria A<br>EN61000-4-2:2009,Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test|3V/m (80-1000, 1800MHz,<br>2600MHz, 3500MHz,<br>5000MHz)|IEC/EN61000-4-3:2006+A2:2010, Criteria A| |Fast Transient and Burst Immunity|AC Power Port: L, N ±1kV|IEC/EN61000-4-4:2012, Criteria A| |Surge Immunity|AC Power Port: L-N ±1kV|IEC/EN61000-4-5:2014, Criteria B| |Immunity to conducted disturbances, induced by radio-frequency felds|AC Power Port: 3V (0.15-<br>10MHz)<br>3V to 1V (10-30MHz)<br>1V(30-80MHz)|IEC61000-4-6:2013. Criteria A<br>EN61000-4-6:2014, Criteria A| |Power Magnetic Field Immunity|50Hz/60Hz, 1A/m|IEC61000-4-8:2009, Criteria A<br>EN61000-4-8:2010,Criteria A| |Voltage Dips and Interruptions|Voltage Dips 100% at<br>50/60Hz|IEC/EN61000-4-11:2004, Criteria A| ||Voltage Dips 30% at 50Hz|IEC/EN61000-4-11:2004,Criteria A| ||Voltage Dips 30% at 60Hz|IEC/EN61000-4-11:2004, Criteria B| ||Voltage Interruptions > 95%<br>at 50Hz|<br>IEC/EN61000-4-11:2004, Criteria C| ||Voltage Interruptions > 95%<br>at 60Hz|<br>IEC/EN61000-4-11:2004, Criteria B| |Limits of Harmonic Current Emissions||EN61000-3-2:2014| |Limits of Voltage Fluctuations & Flicker||EN61000-3-3:2013| |DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|PCB<br>baseplate / case(“/ENC”)|FR4, (UL94 V-0)<br>aluminium| |Dimension (LxWxH)|open frame version<br>enclosed version|101.6 x 50.8 x 32.0mm<br>105.0 x 62.0 x 35.0mm| |Weight|open frame version<br>enclosed version|220g typ.<br>290gtyp.| |continued on nextpage||| REV.: 3/2021 MED-6 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) **==> picture [509 x 672] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing Open Frame (mm) 101.6<br>1<br>2<br>CON3<br>9<br>Top View 8<br>1<br>7<br>6<br>3<br>5<br>4<br>ADJ<br>5.0 91.6<br>Side View<br>4 x Ø3.5 FC 95.25 FC 3.2<br>General tolerances according to ISO 2768-m<br>(table for reference only)<br>Bottom View<br>Dimension range Tolerances<br>0.5 - 6 mm ±0.1 mm<br>6 - 30 mm ±0.2 mm<br>30 - 120 mm ±0.3 mm<br>120 - 400 mm ±0.5 mm<br>AC side DC side<br>2x 3.96 17.45 11.62 5x 3.96<br>Spring Washer (0.7mm)<br>Baseplate<br>Standoff (2.0mm)<br>Application<br>CON3<br>CON1 CON2 Typ. tightening torque= 0.6Nm<br>Compatible Connector (valid for open frame and enclosed version)<br>AC Input (CON1) DC Output Connector (CON2) FAN Connector (CON3)<br> # Function Connector # Function Connector # Function Connector<br>1 AC/N Molex 09-50-3031 7,8,9 +Vout Molex 09-50-1061 1 -FAN Molex 22-01-1022<br>3 AC/L or similar 4,5,6 -Vout or similar 2 +FAN or similiar<br>Maximum tightening torque for mounting without standoffs: 0.3Nm<br>FC = fixing centers<br>continued on next page<br>50.8<br>CON1 CON2<br><32.0<br> ±1.0<br>3.0<br>FC 44.45<br>FC 3.2<br>**----- End of picture text -----**<br> REV.: 3/2021 MED-7 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) **==> picture [525 x 687] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing Enclosed Version (mm)<br>105.0<br>9<br>8<br>1 Top View 7<br>6<br>3<br>5<br>4<br>ADJ<br>Side View<br>embossed logo<br>FC 95.25 FC 4.87<br>2 x Ø3.5<br>Bottom View<br>Notes:<br>AC si de DC side<br> Note12: Pleas e remove cover, to use trim function<br>2x 3.96 23.0 17.2 5x 3.96<br>Maximum tightening torque for mounting: 0.6Nm<br>FC = fixing centers<br>General tolerances according to ISO 2 768-m<br>(table for reference only)<br>Dimension range Tolerances<br>CON3 0.5 - 6 mm ±0.1 mm<br>CON1 CON2 6 - 30 mm ±0.2 mm<br>30 - 120 mm ±0.3 mm<br>120 - 400 mm ±0.5 m m<br>CON3<br>62.0<br>CON1 CON2<br>35.0<br>5<br> 44.4<br>C<br>F<br>FC 8.7<br>**----- End of picture text -----**<br> REV.: 3/2021 MED-8 **www.recom-power.com** ## **RACM230-G** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated) ## INSTALLATION AND APPLICATION **==> picture [476 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting<br>horizontal (standard) side 1 side 2 vertical<br>DC AC<br>airflow<br>upside-down<br>airflow<br>AC DC<br>Notes:<br>Note13: If module is side mounted, vertically or upside-down with natural convection cooling, the power must be derated<br> down to 85% for the RACM230-12SG, for the other models 90%.<br> For convection cooling, ensure sufficient distance to adjacent components!<br> Device should be fan cooled from DC side.<br>AC<br>CON3<br>CON2<br>CON2<br>CON3<br>DC<br>airflow<br>**----- End of picture text -----**<br> **==> picture [525 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>ADJ<br>PFC LLC Feedback<br>Controller<br>Controller and Isolation<br>L Fuse, Inrush +Vout<br>Current Linitation, Rectifier + PFC Switcher Rectifier Output<br>N Input Filter Bulk Cap Boost Filter -Vout<br>PE<br>+Fan<br>Rectifier<br>Transformer -Fan<br>**----- End of picture text -----**<br> |||| |---|---|---| |PACKAGING INFORMATION||| |Parameter|Type|Value| |PackagingDimension(LxWxH)|cardboard box|112.0 x 80.0 x 50.0mm| |PackagingQuantity||1pcs| |Storage Temperature Range||-55°C to +100°C| |Storage Humidity|non-condensing|5% - 90% RH max.| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 3/2021 MED-9 **www.recom-power.com**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →