Image not available
Illustrative purposes only
RACM18-05SER
PCB MOUNT AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 42.03 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Converter** ## Features - Medical certified 2MOPP module, BF ready - Class II installations (without FG) - IP68 waterproof encapsulation - Operation altitude certified up to 5000m ## Regulated Converter - No external components necessary - Energy Efficiency Level **VI** ## Description The RACM18-ER series comprises highly reliable power conversion modules in a potted IP68 waterproof encapsulation to withstand harsh operating conditions. With a certified operation up to 5000m altitude and a temperature range from -20°C up to +80°C these modules are built to power medical healthcare, household, sanitary, smart building and automation process appliances. For easy integration the product line is certified to medical, household, as well as to ITE safety standards and designed to pass class B limits by more than 6dB margin without the need for any external components. ## **RACM18-ER** ## y **18 Watt Round Shape Single Output** ## Selection Guide |Part|Input|Output|Output|Efficiency| |---|---|---|---|---| |Number<br>Voltage Range<br>Voltage(1)<br>Current<br>typ.(2)<br>[VAC]<br>[VDC]<br>[A]<br>[%]<br>~~ee~~||||| |RACM18-05SER(3)|90-264|5|2.5|81| |RACM18-12SER(3)|90-264|12|1.5|82| |RACM18-24SER(3)|90-264|24|0.75|83.5| Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25°C ambient ## Model Numbering ## RACM18-__ SER[(3)] Output Power **S** ingle Output Voltage ## Notes: Note3: Other connection types on reqeuest **==> picture [94 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> R<br>°@<br>C US<br>REBA VEBA<br>Kone ><br>.<br>S ()<br>RR RO y y<br>2MOPP<br>280VAC<br>**----- End of picture text -----**<br> IEC/EN60950-1 certified UL60950-1 certified ANSI/AAMI ES60601-1 certified IEC/EN60601-1 certified IEC/EN60335-1 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified IEC/EN60601-1-2 certified EN55024/32 certified EN55014-1 (-2) certified CISPR32 certified REV.: 2/2018 MED-1 **www.recom-power.com** **RACM18-ER Series** ## **AC/DC Converter** Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) BASIC CHARACTERISTICS ~~a a~~ Parameter Condition Min. Typ. Max. ~~a~~ Internal Input Filter Pi type ~~a~~ Input Voltage Range 90VAC 230VAC 264VAC 115VAC 500mA Input Current 230VAC 150mA ~~ee~~ 115VAC 24A Inrush Current 230VAC 46A ~~ee a~~ No load Power Consumption ~~OOee ee~~ 40mW 75mW ~~OO~~ Input Frequency Range 47Hz 63Hz Minimum Load 0% ~~a~~ Power Factor 0.46 ~~a~~ 115VAC 180ms Start-up Time 230VAC 200ms ~~ee~~ Rise Time 115VAC/230VAC 15ms ~~a ee~~ 115VAC 15ms Hold-up Time 230VAC 65ms ~~es a~~ Internal Operating Frequency ~~OO~~ 100% load at nominal Vin ~~ee ee~~ 100kHz ~~a~~ Output Ripple and Noise 20MHz BW 140mVp-p Efficiency vs. Load **==> picture [56 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> RACM18-12SER<br>**----- End of picture text -----**<br> RACM18-24SER **==> picture [464 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>90 90<br>ee a<br>80 80<br>70 pA 70 aa<br>60 60<br>> Ae 7) Ae<br>50 50<br>7 ee ee ee<br>40 go 40 goo<br>30 30<br>20 jo 85VAC 20 7 85VAC<br>115VAC 115VAC<br>10 jo 230VAC 10 j 230VAC<br>264VAC 264VAC<br>0 0<br>po po<br>0 25 50 75 100 0 25 50 75 100<br>Output Load [%] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> |REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---| |Parameter|Condition|Value| |Output Accuracy||±3.0% max.| |Line Regulation|low line to high line|±1.0% max.| |Load Regulation|0% to 100% load|±1.0% max.| |Transient Response|100% load stepchange|±3.0% max.| |continued on nextpage||| REV.: 2/2018 MED-2 **www.recom-power.com** ## **RACM18-ER** ## **AC/DC Converter** ## **Series** Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) **==> picture [488 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> Accuracy vs. Load<br>(@ min Vin to max. Vin)<br>RACM18-12SER RACM18-24SER<br>+3.0 +3.0<br>pT<br>+2.0 +2.0<br>+1.0 +1.0<br>ee ee ee ee<br>0 ee 0<br>a ee<br>-1.0 -1.0<br>-2.0 -2.0<br>ee ee ee<br>-3.0 a a -3.0<br>0 25 50 75 100 0 25 50 75 100<br>Output Load [%] Output Load [%]<br>Deviation [%] Deviation [%]<br>**----- End of picture text -----**<br> |PROTECTIONS<br>~~Ct~~|PROTECTIONS<br>~~Ct~~| |---|---| |Parameter<br>Type<br>Value<br>~~a~~|| |Input Fuse<br>internal(line & neutral)<br>T2A,slow blow<br>~~a~~|| |Short Circuit Protection(SCP)<br>continuous,auto recovery<br>Over Voltage Protection (OVP)<br>5Vout, 12Vout<br>24Vout<br>16VDC, Latch OFF<br>24VDC,Latch OFF<br>Over Voltage Category (OVC)<br>OVCII<br>~~a~~<br>~~a~~<br>~~ee~~|| |Over Current Protection (OCP)<br>< 1 minute<br>90VAC<br>160VAC<br>264VAC<br>145% of nominal Output Current, auto recovery<br>180% of nominal Output Current, auto recovery<br>165% of nominal Output current,auto recovery<br>Hiccup Mode<br>Over Temperature Protection(OTP)<br>95°C ambient<br>thermal shutdown, auto recovery<br>~~a~~<br>~~ee~~<br>~~ee~~<br>~~Ce~~|| |Class of Equipment<br>ClassII<br>~~GG~~|| |Isolation Voltage(3)<br>I/P to O/P<br>tested for 1 minute<br>4.6kVAC<br>~~GG~~|| |Insulation Grade<br>reinforced<br>~~fe~~|| |Leakage Current<br>~~a~~|100µA max.| |Means of Protection<br>280VAC working voltage<br>~~a~~|2MOPP| |Medical Device Classification<br>Type BF<br>~~He~~|| |Notes:|| |Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage|| ||| |ENVIRONMENTAL|| |Parameter<br>Condition|Value| |Operating Temperature Range<br>natural convection 0.1m/s<br>without derating<br>with derating|-20°C to +50°C<br>-20°C to +80°C| |Maximum Case Temperature|+85°C| |OperatingAltitude|5000m| |OperatingHumidity<br>non-condensing|95% RH max.| |Pollution Degree|PD2| |MTBF<br>according to MIL-HDBK-<br>217F,G.B.<br>+25°C<br>+50°C|563 x 103hours<br>112 x 103hours| |Design Lifetime|130 x 103hours| continued on next page REV.: 2/2018 MED-3 **www.recom-power.com** ## **RACM18-ER** ## **AC/DC Converter** ## **Series** Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) Derating Graph (@ Chamber and natural convection 0.1m/s) 100 80 ~~CCTTEN Tit~~ 60 45 40 ~~eff befdeff TELE~~ 20 ~~TT TT~~ 0 -20 ELUTE -10 0 10 20 30 40 50 TTT 60 70 80 90 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS ~~ee~~ Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety IEC60950-1:2005, 2nd Edition + Am2:2013 T223-0257/17 ~~a~~ (CB Scheme) EN60950-1:2006 + A2:2013 Information Technology Equipment, General Requirements for UL60950-1, 2nd Edition:2014 T223-0257/17 ~~ee~~ Safety CAN/CSA C22.2 No. 60950-1, 2nd Edition:2014 Medical Electric Equipment, General Requirements for Safety IEC60601-1:2005, AM1:2012 T223-0256/17 ~~a~~ and Essential Performance (CB Scheme) EN60601-1:2006 + A12:2014 Medical Electric Equipment, General Requirements for Safety CAN/CSA-C22.2 No. 60601-1:14, 3rd Edition 2014 T223-0256/17 and Essential Performance ANSI/AAMI ES60601-1:2005 ~~es~~ Household and similar electrical appliances - Safety IEC60335-1:2010, 5th Edition + A1:2013 T211-0761/17 ~~a~~ Part 1: General requirements (CB Scheme) EN60335-1:2012 + A11:2014 Safety of power transformers, power supplies, reactors and IEC61558-1:2005, 2nd Edition + A1:2009 similar products for supply voltages up to 1100V EN61558-1:2005 + A1:2009 Safety of transformers, reactors, power supply units and similar T211-0762/17 IEC61558-2-16:2009, 1st Edition + A1:2013 products for supply voltages up to 1100 V - Part 2-16: Particular EN61558-2-16:2009 + A1:2013 ~~——~~ requirements and tests for switch mode power supply units EAC RU-AT.49.09571 TP TC 004/2011 TP TC 004/2011 ~~Eee~~ RoHs 2 (2+) RoHs 10/10, AM2015 ~~oe a~~ EMC Compliance (Medical) ~~G~~ Condition Standard / Criterion Medical electrical equipment Part 1-2: Electromagnetic disturEN60601-1-2:2015 ~~ee~~ bances – ReESD Electrostatic discharquirements and testsge immunity test ~~ee~~ Air ±2, 4, 8, 15kV; Contact ±8kV IEC61000-4-2:2008, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 10V/m (80 - 2700MHz) IEC61000-4-3:2006 + A2:2010 , Criteria A 27V/m (385MHz), 28V/m (450MHz), 9V/m Radiated, radio-frequency, electromagnetic field immunity test (710, 745, 780MHz), 28V/m (810, 870, 930, IEC61000-4-3:2006 + A2:2010, Criteria A (table 9) 1720, 1845, 1970, 2450MHz), 9V/m (5240, ~~a~~ 5500, 5785MHz) AC Power Port ±2.0kV Fast Transient and Burst Immunity ~~ee~~ IEC61000-4-4:2012, Criteria A ~~ee es~~ DC Output Port ±1kV ~~DG~~ Surge Immunity AC Power Port: L-N ±0.5, 1.0kV IEC61000-4-5:2005, Criteria A ~~ce~~ continued on next page REV.: 2/2018 MED-4 **www.recom-power.com** **Series** ## **RACM18-ER** ## **AC/DC Converter** Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) ~~a~~ EMC Compliance (Medical) Condition Standard / Criterion AC Power Port 6V Immunity to conducted disturbances, induced by radio-frequency fields IEC61000-4-6:2013, Criteria A ~~pf~~ DC Output Port 6V ~~De~~ Power Magnetic Field Immunity 50Hz, 60Hz, 30A/m IEC61000-4-8:2009, Criteria A ~~a~~ Voltage Dips and Interruptions IEC61000-4-11:2004, Criteria A ~~Ge~~ EMC Compliance (Household) Condition Standard / Criterion ~~a~~ Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55014-1:2006 + A2:2011 Information technology equipment - Immunity characteristics - Limits and EN55014-2:1997 + A2:2008 methods of measurement ~~a eC~~ ESD Electrostatic discharge immunity test Air ±8kV; Contact ±4kV EN61000-4-2:1995 + A2:2001, Criteria A ~~Ge~~ Radiated, radio-frequency, electromagnetic field immunity test 3V/m (80 - 1000MHz) EN61000-4-3:2006 + A1:2008, Criteria A AC Power Port: ±1.0kV Fast Transient and Burst Immunity EN61000-4-4:2004, Criteria A DC Power Port ±0.5kV ~~pf a~~ Surge Immunity AC Power Port: L-N ±0.5, 1.0kV EN61000-4-5:2006, Criteria A AC Power Port 3V Immunity to conducted disturbances, induced by radio-frequency fields EN61000-4-6:2007, Criteria A DC Power Port 3V ~~pf a~~ Voltage Dips and Interruptions EN61000-4-11:2004 ~~a~~ EMC Compliance (Multimedia) ~~**G**~~ Condition Standard / Criterion ~~e~~ Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2010, Class B Information technology equipment - Immunity characteristics - Limits and methEN55024:2010 ods of measurement ~~pf~~ Electromagnetic compatibility of multimedia equipment - Emission requirements CISPR 32:2012, Class B ~~a~~ ESD Electrostatic discharge immunity test Air ±2, 4, 8kV; Contact ±4kV EN61000-4-2:2009, Criteria A ~~a~~ Radiated, radio-frequency, electromagnetic field immunity test 3V/m (80 - 1000MHz) EN61000-4-3:2006 + A2:2010, Criteria A AC Power Port: ±1.0kV Fast Transient and Burst Immunity EN61000-4-4:2004, Criteria A DC Power Port ±0.5kV ~~pf a~~ Surge Immunity ~~G~~ AC Power Port: L-N ±0.5, 1.0kV EN61000-4-5:2006, Criteria A AC Power Port 3V Immunity to conducted disturbances, induced by radio-frequency fields EN61000-4-6:2009, Criteria A DC Power Port 3V ~~pf~~ Power Magnetic Field Immunity 50Hz, 60Hz, 1A/m EN61000-4-8:2010, Criteria A ~~a~~ Voltage Dips and Interruptions EN61000-4-11:2004 ~~a~~ Limits of Voltage Fluctuations & Flicker IEC/EN61000-3-3:2013 |DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|Case<br>Potting<br>PCB|non-conductive black plastic, (UL94V-0)<br>polyurethane, (UL94V-0)<br>FR4, (UL94V-0)| |Package Dimension(LxWxH)||53.0 x 51.0 x 24.5mm| |Package Weight||88gmax.| |continued on nextpage||| continued on next page REV.: 2/2018 MED-5 **www.recom-power.com** **Series** ## **RACM18-ER** ## **AC/DC Converter** Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) **==> picture [520 x 639] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing (mm) i<br>FC 12.5<br>tc<br>embossed logo<br>Ø 3.2<br>a)<br>D e<br>FC 12.5<br>53.0<br>2.5°<br>TA L<br>0.88 ±0.01 0.60 ±0.02<br>— —s an<br>FC 25.0<br>3.22<br>0.08 [+0.03][-0]<br>a — Pin Connections<br> Pin # Single<br>knurled pins 1 +Vout<br>1 2 2 -Vout<br>7.00<br>3 VAC in (L)<br>Bottom View 4 VAC in (N)<br>tc= case temperature measuring point<br>FC = fixing centers<br>5.25 3 Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.25mm<br>4<br>Max. tightening torque fixing screws: 0.3Nm<br>aa) —<br>34.25<br>PACKAGING INFORMATION<br>Parameter Type Value<br>Packaging Dimension (LxWxH) carton 310.0 x 220.0 x 100.0mm<br>Packaging Quantity 10pcs<br>Storage Temperature Range -30°C to +80°C<br>Storage Humidtiy non-condensing 95% RH max.<br>57.1<br>FC 20.5<br>0<br>1.<br>5<br>FC 20.5<br>24.5<br>3.5<br>4.96<br>35.00 36.04 30.50 FC 41.0<br>**----- End of picture text -----**<br> The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 2/2018 MED-6 **www.recom-power.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →