Image not available
Illustrative purposes only
RACM100-12S/OF
ENCLOSED AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 138.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **![NOT RECOMMENDED FOR NEW DESIGNS] !** rrrt—“_OS—s—s—s—s—s—s—s——SSY - Long 5 year warranty ## Features - 2MOPP/250VAC - Suitable for built in Class II applications - Wide input voltage range (85-264VAC) ## Regulated Converter - Low leakage current (<75µA) - 5000m operation - Active power factor correction ## Description The RACM100 is a compact 3” x 2” high efficiency AC/DC power supply with 2xMOPP 3rd Ed. safety approval for medical applications. The range has now been extended to include open frame models (/OF suffix). Like the original enclosed versions, the RACM100/OF series are space-saving universal input voltage power supplies (85-264VAC), with 4kVAC isolation, PFC, no minimum load and can be used at ambient temperatures of between -25°C and +85°C. The 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than ±0.2% over the entire input voltage range and less than ±0.5% over the entire load range. The RACM100/OF series is certified to medical safety standard IEC/ES/EN-60601-1 3rd Edition and feature BF rated outputs with less than 75µA leakage current. It has a built-in Class B EMI filter and comes with a five year warranty. ## **AC/DC Converter** ## **RACM100** **==> picture [141 x 114] intentionally omitted <==** **----- Start of picture text -----**<br> 100 Watt<br>5<br>Enclosed &<br>Open Frame<br>Case Style<br>Single Output<br>r<br>EA<br>r a<br>Y R<br>wa nty<br>**----- End of picture text -----**<br> ## Selection Guide |Part<br>Number|Input<br>Voltage Range|Output<br>Voltage|Output<br>Current|Input Power<br>@ No Load|Efficiency Max. Capacitive<br>typ.|Efficiency Max. Capacitive<br>Load(1)| |---|---|---|---|---|---|---| ||[VAC]|[VDC]|[A]|[W]|[%]|[µF]| |RACM100-12S(1)|85-264|12|8.34|0.3|91|6950| |RACM100-15S(1)|85-264|15|6.67|0.3|92|4450| |RACM100-24S(1)|85-264|24|4.17|0.3|92|1750| |RACM100-48S(1)|85-264|48|2.09|0.3|91|430| Notes: Note1: Max Cap Load is tested at minimum input and full resistive load ## Model Numbering ## RACM100- __ S/ __ **==> picture [241 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> Output Power Case Style [(2)]<br>Output Voltage Single<br>**----- End of picture text -----**<br> Notes: Note2: without suffix, standard enclosed case add suffix _“/OF”_ for open frame style Examples: RACM100-12S = 12Vout, standard enclosed case RACM100-24S/OF = 24Vout, open frame style **2MOPP 250VAC** FEC € Ae **E314885** ® IEC/EN60601 certified ANSI/AAMI ES60601 certified EN55011 certified CISPR11 FCC Part 15 REV.: 12/2022 MED-1 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **RACM100 Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) ## BASIC CHARACTERISTICS **==> picture [526 x 670] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Condition Min. Typ. Max.<br>85VAC 264VAC<br>Input Voltage<br>120VDC 370VDC<br>115VAC, fulll load 1.15A<br>Input Current<br>230VAC, full load 0.55A<br>Inrush Current cold start, 230VAC 60A<br>No load Power Consumption 0.11W<br>Input Frequency Range AC Input 47Hz 63Hz<br>Output Voltage Trimming ±10.0%<br>Minimum Load 0%<br>Power Factor 0.95<br>Start-up Time 1s<br>Rise Time 20ms<br>Hold up Time 115VAC, full load 16ms<br>Internal Operating Frequency 60kHz<br>12VDC, with 10µF/25V MLCC 120mVp-p<br>Output Ripple and Noise 15VDC, with 10µF/25V MLCC 150mVp-p<br>(measured @ 20MHz BW) 24VDC, with 1µF/50V MLCC 160mVp-p<br>48VDC, with 0.1µF/100V MLCC 340mVp-p<br>Efficiency vs. Load Efficiency vs. Input Voltage<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>115VAC 50% load<br>10 10<br>230VAC 100% load<br>0 0<br>10 20 30 40 50 60 70 80 90 100 85 105 125 145 165 185 205 225 245 264<br>Output Load [%] Input Voltage [VAC]<br>Line Derating Power Factor vs. Load<br>1<br>100<br>90 0.8<br>80<br>70 0.6<br>60<br>0.4<br>50<br>40<br>0.2 115 VAC<br>30 230 VAC<br>20 0<br>85 105 125 145 165 185 205 225 245 264 30 40 50 60 70 80 90 100<br>100<br>Input Voltage [VAC] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>Output Load [%] Power Factor [ ]<br>**----- End of picture text -----**<br> REV.: 12/2022 MED-2 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **RACM100 Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) |REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---| |Parameter|Condition|Value| |Output Accuracy|230VAC,full load|±1.0%| |Line Regulation|low line to high line, full load|±0.2%| |Load Regulation|0% to 100% load<br>10% to 100% load|0.5% max.<br>0.4% max.| |Transient Peak Deviation|load stepfrom 50% - 75% change at 2.5A/µs|3.0% Vout max.| |Transient RecoveryTime|load stepfrom 50% - 75% change at 2.5A/µs|500µs typ.| |PROTECTIONS||||| |---|---|---|---|---| |Parameter||Condition||Value| |Input Fuse||internal line and neutral||T3.15A / 250VAC, slow blow type| |Short Circuit Protection(SCP)||||continuous, auto-recovery| |Over Load Protection(OLP)||% of Iout rated(Hiccup)||115% min. / 150% max.| |Over Voltage Protection(OVP)||% of Vout nominal(Latch off)||115% min. / 135% max.| |Isolation Voltage(5)||tested for 1 minute|I/P to O/P<br>I/P to Case<br>O/P to Case|4kVAC<br>1.5kVAC<br>1.5kVAC| |Isolation Resistance||500VDC||100MWmin.| |Insulation Grade||||reinforced| |Leakage Current||264VAC||75µA max.| |Means of Protection||workingvoltage 250VAC/continuous||2MOPP| |Medical Device Classifcation||||built-inpower supply| |Internal||clearance<br>creepage||>8.0mm<br>>8.0mm| ||Notes:<br>Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage|||| |ENVIRONMENTAL|||| |---|---|---|---| |Parameter|Condition||Value| |Operating Temperature Range|refer to_”Derating Graph”_||-25°C to +85°C| ||full load, 230VAC|enclosed<br>open frame|-25°C to +60°C<br>-25°C to +55°C| |Temperature Coeffcient|||±0.02%/K| |OperatingAltitude|||5000m max.| |OperatingHumidity|non-condensing||5% to 95% RH| |Pollution Degree|||PD2| |High Temperature OperatingLife(HTLO)|||JEDEC JESD22-A108| |Shock|||IEC60068-2-27| |Vibration|||IEC60068-2-6| |MTBF|accordingto MIL-HDBK-217F, full load, +25°C||790.3 x 103hours| ||continued on nextpage||| REV.: 12/2022 MED-3 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **RACM100** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) **==> picture [525 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> Derating Graph<br>(@ Chamber and natural convection 0.1m/s)<br>Enclosed /OF version<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>115VAC 115VAC<br>10 10<br>230VAC 230VAC<br>0 0<br>-25 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 -25 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110<br>55 85 55 85<br>Ambient Temperature [°C] Ambient Temperature [°C]<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br> |SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|| |---|---|---|---| |Certifcate Type(Safety)|Report / File Number||Standard| |Medical Electric Equipment, General Requirements for Safety and Essential Performance|E314885||CAN/CSA-C22.2 No. 60601-1:14<br>ANSI/AAMI ES60601-1:2005 + A2:2010| |Medical Electric Equipment, General Requirements for Safetyand Essential Performance(CB)|181200102||IEC60601-1:2005 + A1:2012, 3rd Edition| |Medical Electric Equipment, General Requirements for Safetyand Essential Performance|||EN60601-1:2006 +12:2014| |Information TechnologyEquipment - General Requirements for Safety (LVD)|TW1708008-001||EN60950-1:2006 + A2:2013| |Information TechnologyEquipment - General Requirements for Safety|||IEC60950-1:2005, 2nd Edition + A2:2013| |EAC|RU-AT.49.09571||TP TC 004/2011 TP TC 004/2011| |RoHS2|||RoHS-2011/65/EU + AM-2015/863| ||||| |EMC Compliance(Medical)|Conditions||Standard / Criterion| |Medical electrical equipment - Part 1-2: General requirements for basic safety and essential<br>performance - Collateral standard: Electromagnetic compatibility- Requirements and tests|||EN60601-1-2:2015| |Industrial, scientifc and medical equipment – Radio frequency disturbance characteristics –<br>Limits and methods of measurement|||EN55011:2009 + A1:2010<br>Class B Conducted,Class A Radiated| |Industrial, scientifc and medical equipment - Radio frequency disturbance characteritics -<br>Limits and methods of measurement|||CISPR11:2009 + A1:2010<br>Class B Conducted,Class A Radiated| |ESD Electrostatic discharge immunitytest|Air ±15kV; Contact ±8kV||IEC61000-4-2:2008| |Radiated, radio-frequency, electromagnetic feld immunity test|10V/m (80-2700MHz)<br>27V/m (385MHz)<br>28V/m(450MHz)||IEC61000-4-3:2006 + A2:2010| |Fast Transient and Burst Immunity|AC Power Port: ±2kV||IEC61000-4-4:2012| |Surge Immunity|AC<br>Port:|L-N= ±1kV<br>L-GND= ±2kV|IEC61000-4-5:2005| |Immunityto conducted disturbances, induced byradio-frequencyfelds|6Vr.m.s||IEC61000-4-6:2013| |Power FrequencyMagnetic Field|50Hz, 30A/m||IEC61000-4-8:2009| |Voltage Dips and Interruptions|Dips: >95%; 30%;<br>Interruptions >95%||IEC61000-4-11:2004| |Limits of Harmonic Current Emissions|||EN61000-3-2:2005 + A2:2009, Class D| |Limits of Voltage Fluctuations and Flicker|||EN61000-3-3:2013| |continued on nextpage|||| REV.: 12/2022 MED-4 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **RACM100** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) |**AC/DC Converter**<br>Specifcations(measured @ Ta= 25°C, 250VAC, full load and after warm-up)||**Series**| |---|---|---| |EMC Compliance(Industrial)|Conditions|Standard / Criterion| |Limitations on the amount of electromagnetic intererence allowed from digital & electronic devices||47CFR FCC Part 15 Subpart B, Class B| |Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and<br>Electronic Equipment in the Range of 9 kHz to 40 GHz||ANSI C63.4:2014| |Electromagnetic compatibilityof multimedia equipment – Emission Requirements||EN55032:2015+AC:2013, Class B| |Information technology equipment - Immunity characteristics - Limits and methods of<br>measurement||EN55024:2010+A1:2015| |ESD Electrostatic discharge immunitytest|Air ±8kV; Contact ±6kV|IEC61000-4-2:2008, Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test|3V/m (80-1000MHz)<br>20V/m (80-1000MHz)<br>3V/m (1-2.5GHz)<br>10V/m (1-2.5GHz|IEC61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity|DC Port: ±2kV|IEC61000-4-4:2012, Criteria A| |Surge Immunity|DC Port: ±1kV|IEC61000-4-5:2014, Criteria A| |Immunity to conducted disturbances, induced by radio-frequency felds|DC Power Port 3V +20V|IEC61000-4-6:2013, Criteria A| |Power Frequency Magnetic Field|50Hz/60Hz 1A/m<br>50Hz/60Hz 10A/m|IEC61000-4-8:2009, Criteria A| |Voltage Dips and Interruptions|Dips: >95%; 60%; 30%<br>Interruptions >95%|IEC61000-4-11:2004, Criteria A<br>IEC61000-4-11:2004,Criteria B| |Limits of Harmonic Current Emissions||EN61000-3-2:2014, Class D| |Limits of Voltage Fluctuations and Flicker||EN61000-3-3:2013| |DIMENSION and PHYSICAL CHARACTERISTICS|DIMENSION and PHYSICAL CHARACTERISTICS|DIMENSION and PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|enclosed|aluminum| |Dimension (LxWxH)|enclsoded<br>open frame|91.4 x 62.0 x 39.2mm<br>76.2 x 50.8 x 32.0mm| |Weight|enclosed<br>open frame|210g<br>150g| |continued on nextpage||| REV.: 12/2022 MED-5 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** **RACM100 Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) **==> picture [510 x 552] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing Enclosed (mm)<br>Top View<br>5 i Trim Adj. h )<br>i n g<br>22.1<br>76.2<br>FC 84.2 Connection via Connector<br>AC Input (CON1)<br>91.4<br>Pin # Pin Header<br>_<br>1 AC/L<br>Side View SVH-21T-P1.1<br>3 AC/N<br>DC Output Connector (CON2)<br>Pin # Pin Header<br>1,2 -Vout<br>SVH-21T-P1.1<br>3,4 +Vout<br>FC = fixing centers<br>Crimp Terminal AWG Range: 18-22AWG<br>Tolerance: ±0.5mm<br>Bottom View<br>=<br>Ø4.0<br>3.5 36.5<br>CON1<br>CON2 62.0<br>FC 41.3<br>24.5<br>39.2<br>.20<br>1<br>10.4<br>14.0<br>10.0<br>34.0<br>**----- End of picture text -----**<br> continued on next page REV.: 12/2022 MED-6 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **RACM100** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) **==> picture [519 x 549] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing Open Frame (mm)<br>ones<br>Top View<br>76.2<br>Cl<br>Connection via Connector<br>AC Input (CON1)<br>Trim Adj. Pin # Pin Header<br>1 AC/L<br>SVH-21T-P1.1<br>3 AC/N<br>DC Output Connector (CON2)<br>Pin # Pin Header<br>Ø3.2 FC 69.8 1,2 -Vout<br>SVH-21T-P1.1<br>29.5 3,4 +Vout<br>FC = fixing centers<br>Crimp Terminal AWG Range: 18-22AWG<br>Tolerance: ±0.5mm<br>Side View<br>tNowy e<br>PACKAGING INFORMATION<br>Parameter Type Value<br>enclosed case 418.0 x 258.0 x 105.0mm<br>Packaging Dimension (LxWxH) cardboard box<br>open frame 494.0 x 250.0 x 95.0mm<br>enclosed case 10pcs<br>Packaging Quantity<br>open frame 25pcs<br>Storage Temperature Range -40°C to +85°C<br>Storage Humidity non-condensing 5% to 95% RH<br>CON1<br> 50.8 FC 44.4<br>CON2<br>18.5<br>29.5<br>1.6<br>2.5<br>**----- End of picture text -----**<br> The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 12/2022 MED-7 **www.recom-power.com**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →