Image not available
Illustrative purposes only
RACD07-500
LED DRIVERS - PSU AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC LED Power Supplies
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 30 |
| Price | 16.79 € |
| Current stock | 100+ |
| Lead time | 30 days |
• 7W Class II AC-DC LED power supply Features • Suitable for high brightness LED Constant • 250mA, 350mA, 500mA and 680mA constant **AC/DC Converter** current operation Current • 3.75kVAC isolation LED Driver • Fused input and SCP, OCP, OVP, OLP • IP67 rated **RACD07** _ CL Description **7 Watt** NEAR The RACD07 is a constant current 7W AC/DC source for LED lighting with a wide input voltage range. The LED drivers are available with constant current outputs of 250mA, 350mA, 500mA or 680mA. **Constant** Darran The series is IP67 rated and suitable for use in dry, damp or wet areas. RACD07 drivers have a 3 year warranty. **Current Single Output**
## Description
The RACD07 is a constant current 7W AC/DC source for LED lighting with a wide input voltage range. The LED drivers are available with constant current outputs of 250mA, 350mA, 500mA or 680mA. The series is IP67 rated and suitable for use in dry, damp or wet areas. RACD07 drivers have a 3 year warranty.
## Selection Guide
|Part|Input|Constant Current(1)|Efficiency|Rated Power|
|---|---|---|---|---|
|Number<br>Voltage Range<br>Mode<br>min.<br>max.<br>[VAC]<br>[VDC]<br>[mA]<br>[%]<br>[W]<br>RACD07-250<br>90-295<br>14-28<br>250<br>75<br>7<br>RACD07-350<br>90-295<br>10-20<br>350<br>70<br>7.3<br>~~TT~~|||||
|RACD07-500|90-295|5-14.5<br>500|70|7.2|
|RACD07-700|90-295|3-10.5<br>680|70|7.1|
All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime.
## Notes:
Note1: Constant current operation region is within 75%-100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
## Model Numbering
## RACD07-___
nom. Output Power nom. Output Current
## Specifications (measured @ ta= 25°C and 115/230VAC)
## BASIC CHARACTERISTICS
|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|
|---|---|---|---|---|
|Parameter|Condition|Min.|Typ.|Max.|
|Input Voltage Range||90VAC|230VAC|295VAC|
|||120VDC||415VDC|
|Input Current|full load, 100VAC|||200mA|
|Inrush Current|230VAC|||10A|
|No Load Power Consumption|230VAC|||0.5W|
|Input FrequencyRange||47Hz||63Hz|
|Power Factor||0.50|||
|Start-upTime||||1s|
|Hold-upTime||18ms|||
|Set-upTime|full load,230VAC|||0.5s|
|Internal OperatingFrequency|||45kHz||
|Output Ripple Current(2)|20MHz BW||30mAp-p||
|continued on nextpage<br>Notes:<br>Note2: Measured with a 12“ twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor|||||
**==> picture [49 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
E340696<br>**----- End of picture text -----**<br>
UL8750 certified UL1310 certified CSA-C22.2 No. 223-M91 certified CSA-C22.2 No. 250.13-12 certified IEC/EN61347 certified IEC/EN61347-2-13 certified EN55015 compliant EN61547 compliant EAC
Note2: Measured with a 12“ twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor
continued on next page
REV.: 4/2019
L-1
**www.recom-power.com**
## **RACD07**
## **AC/DC Converter**
## **Series**
Specifications (measured @ ta= 25°C and 115/230VAC)
Input Voltage vs. Load 100 90 80 70 60 50 40 30 20 10 0 80 90 100 120 140 160 180 200 220 240 295 Input Voltage [VAC] REGULATIONS Parameter Condition Value Output Voltage Accuracy includes: line, load and tolerance ±5% ~~—SS=S=S~~ Output Current Accuracy ±3% typ. / ±7% max. PROTECTION Parameter Condition Value Internal Input Fuse T1A, slow blow Short Circuit Protection (SCP) Hiccup Mode, auto recovery after fault condition is removed Overload Protection (OLP) 105% - 120% typ. Over Current Protection (OCP) Constant current mode protection Isolation Voltage I/P to O/P 3.75kVAC / 1 minute Isolation Resistance 500VDC 100M W min.
Notes:
Note3: Refer to local wiring regulations if input over-current protection is also required
## Maximum loading of automatic circuit breakers*
|* @ 115VAC, 1Ohm, 90° phase angle|* @ 115VAC, 1Ohm, 90° phase angle|* @ 115VAC, 1Ohm, 90° phase angle|* @ 115VAC, 1Ohm, 90° phase angle|* @ 115VAC, 1Ohm, 90° phase angle|* @ 115VAC, 1Ohm, 90° phase angle||* @ 230VAC, 1Ohm, 90° phase angle|* @ 230VAC, 1Ohm, 90° phase angle|* @ 230VAC, 1Ohm, 90° phase angle|* @ 230VAC, 1Ohm, 90° phase angle|* @ 230VAC, 1Ohm, 90° phase angle|* @ 230VAC, 1Ohm, 90° phase angle||* @ 277VAC, 1Ohm, 90° phase angle|* @ 277VAC, 1Ohm, 90° phase angle|* @ 277VAC, 1Ohm, 90° phase angle|* @ 277VAC, 1Ohm, 90° phase angle|* @ 277VAC, 1Ohm, 90° phase angle|* @ 277VAC, 1Ohm, 90° phase angle|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and max. load|||and max. load||||and max. load|||and max. load||||and max. load|||and max. load|||
|Circuit Breaker|Circuit Breaker Current||||||Circuit Breaker|Circuit Breaker Current||||||Circuit Breaker|Circuit Breaker Current|||||
|Typ|10A||16A|20A|25A||Typ|10A||16A|20A|25A||Typ|10A||16A|20A|25A|
|C|101||128|171|228||B|61||100|121|150||B|70||115|139|172|
||||||||C|121||164|221|291||C|139||188|254|334|
## ENVIRONMENTAL
|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|
|---|---|---|---|
|Parameter|Condition||Value|
|OperatingTemperature Range|@ natural convection 0.1m/s, full load||-20°C to +50°C|
|Max. Case Temperature|||+85°C|
|OperatingHumidity|non condensing||20% - 90% RH|
|IP Rating|||IP67|
|Vibration|10-500Hz, 2G; 10 minute/cycle||1 cycleperiod for 60 min each alongX, Y and Z axes|
|Design Lifetime|+25°C ambient||70 x 103hours|
|MTBF|accordingto MIL-HDBK-217F,G.B.|+25°C|200 x 10³ hours|
|continued on nextpage||||
continued on next page
REV.: 4/2019
L-2
**www.recom-power.com**
**RACD07 Series**
**AC/DC Converter**
|Specifications(measured @ ta= 25°C and 115/230VAC)<br>~~Lo~~|Specifications(measured @ ta= 25°C and 115/230VAC)<br>~~Lo~~|Specifications(measured @ ta= 25°C and 115/230VAC)<br>~~Lo~~|
|---|---|---|
|Derating Graph|||
|(@ natural air convection 0.1m/s)<br>Output Load [%]|100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>~~————~~<br>~~PF~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[|~~<br>~~fF~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[|~~<br>~~fT |~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[| fl~~<br>~~fF~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[|~~<br>~~fT |~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[~~<br>~~fT |~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[|~~<br>~~fy |~~<br>~~fF~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~[|~~<br>~~fT |~~<br>~~fF~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~| fy~~<br>|<br>|<br>|<br>|<br>|<br>|<br>[| ~~{|~~||
||-20<br>-10<br>0<br>10<br>20<br>30<br>40<br>50<br>60||
||Ambient Temperature [°C]||
|SAFETY AND CERTIFICATIONS<br>~~Pee~~|SAFETY AND CERTIFICATIONS<br>~~Pee~~|SAFETY AND CERTIFICATIONS<br>~~Pee~~|
|---|---|---|
|Certificate Type(Safety)<br>~~nn~~<br>~~—————~~|Report Number<br>~~nn~~<br>~~—————~~|~~nn~~<br>~~—————~~|
|Standard for LED Equipment for use in LightingProducts<br>~~nn~~<br>~~—————~~<br>~~BP~~|E340696-1-7<br>~~nn~~<br>~~—————~~|UL8750,1st Edition,2009<br>~~nn~~<br>~~—————~~<br>~~ee~~|
|Standard for Class 2 Power Units<br>~~—————~~<br>~~BP~~<br>~~Pe~~||UL1310,6th Edition,2011<br>~~—————~~<br>~~ee~~<br>~~ee~~|
|LED Equipment for LightingApplications<br>~~—————~~<br>~~BP~~<br>~~Pe~~<br>~~BP~~||CSA-C22.2 No. 250.13-12<br>~~—————~~<br>~~ee~~<br>~~ee~~<br>~~eee~~|
|Canadian Standard for Powr Supplies with Extra-Low-Voltage Class 2 Outputs<br>~~—————~~<br>~~Pe~~<br>~~BP~~<br>~~ee~~||CSA C22.2 No. 223-M91<br>~~—————~~<br>~~ee~~<br>~~eee~~<br>~~PO~~|
|Safetyof controlgear for LED modules<br>~~—————~~<br>~~BP~~<br>~~ee~~<br>~~ee~~|PSE102-0283<br>~~—————~~<br>~~ee~~|IEC/EN61347-2-13,2nd Edition 2014<br>~~—————~~<br>~~eee~~<br>~~PO~~<br>~~ee~~|
|Safety requirements for lamp controlgear<br>~~ee~~<br>~~ee~~||IEC61347-1, 3rd Edition, 2015<br>EN61347-1:2015<br>~~PO~~<br>~~ee~~|
|RoHS2<br>~~rn~~|~~rn~~|RoHS-2011/65/EU + AM-2015/863<br>~~rn~~|
|EAC<br>~~eee~~|RUД- AT.AB49.B.09571<br>~~eee~~|TP TC 004/2011<br>~~eee~~|
||||
|EMC Compliance<br>~~Pee~~|Condition<br>~~Pee~~<br>~~ee~~|Standard / Criterion<br>~~Pee~~<br>~~ee~~|
|Limits and methods of measurement of radio disturbance characteristics of<br>electrical lightingand similar equipment<br>~~ee~~|~~ee~~<br>~~ee~~<br>~~ts~~|EN55015:2013 + A1:2015, Class B<br>~~ee~~<br>~~ee~~|
|Equipment forgeneral lighting purposes – EMC immunityrequirements<br>~~ts~~|~~ee~~<br>~~ts~~<br>~~ts~~<br>~~ee~~|EN61547:2009<br>~~ee~~<br>~~ts~~|
|Information technology equipment - Radio disturbance characteristics - Limits<br>and methods of measurement<br>~~es~~|~~ts~~<br>~~es~~<br>~~ee~~|CISPR22, 3rd Edition, 1997, Class B<br>~~es~~|
|Radio FrequencyDevices,Subpart B - Unintentional Radiators<br>~~es~~<br>~~rt~~<br>~~a~~|~~es~~<br>~~ee~~<br>~~rt~~<br>~~es~~<br>|47 CFR,FCC Part 15 Subpart B,Class B<br>~~es~~<br>~~rt~~<br>|
|Methods of Measurement of Radio-Noise Emissions from Low-Voltage<br>Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz<br>~~rt~~<br>~~es~~<br>~~a~~|~~rt~~<br>~~es~~<br>~~es~~<br>|ANSI C63.4:2009<br>~~rt~~<br>~~es~~<br>|
|AlternatingCurrent High Voltage Power Systems<br>~~a~~|~~es~~<br>|Canadian ICES-003 issue 4,2004<br>|
|ESD Electrostatic discharge immunity test<br>~~aee~~|±8, 4, 2kV Air Discharge,<br>±4, 2 kV Contact Discharge<br>~~es~~<br>~~ee~~|IEC61000-4-2:2008 Criteria A<br>~~ee~~|
|Radiated,radio-frequency,electromagnetic field immunitytest<br>~~ee~~<br>~~rr~~|±4, 2 kV Contact Discharge<br>3V/m<br>~~ee~~<br>~~rr~~<br>~~es~~|IEC61000-4-3:2006 + A2:2010 Criteria A<br>~~ee~~<br>~~rr~~|
|Fast Transient and Burst Immunity<br>~~rr~~<br>~~es~~|±0.5, ±1kV AC Input<br>±0.5kV DC Output<br>~~rr~~<br>~~es~~<br>~~es~~|IEC61000-4-4:2012, Criteria A<br>~~rr~~<br>~~es~~|
|Surge Immunity|±0.5,±1kV AC Input<br>~~es~~|IEC61000-4-5:2014,Criteria A|
|Immunityto conducted disturbances,induced byradio-frequencyfields<br>~~rr~~<br>~~a~~|AC and DC Port: 3V<br>~~rr~~<br><br>~~———~~|IEC61000-4-6:2013,Criteria A<br>~~rr~~<br>|
|Power FrequencyMagnetic Field Immunity<br>~~a~~|3A/m at 50/60Hz<br><br>~~———~~|IEC61000-4-8:2009,Criteria A<br>|
|Voltage Dips and Interruptions<br>~~aa~~<br>~~ee~~|Dips: >95%<br>~~a~~<br>~~———~~|IEC61000-4-11:2004 Criteria B<br>~~a~~|
||Dips: 30%<br>~~a~~<br>~~———~~<br>~~ee~~<br>~~ts~~|IEC61000-4-11:2004 Criteria B<br>~~a~~<br>~~ee~~|
|Limits for harmonic current emissions<br>~~rs~~|~~———~~<br>~~rs~~<br>~~ts~~|IEC61000-3-2,2014<br>~~rs~~|
|Limitation of voltage fluctuations/flicker in low-voltage systems<br>~~Ds~~|~~———~~<br>~~ts~~<br>~~Ds~~|IEC61000-3-3,2013<br>~~Ds~~|
REV.: 4/2019
L-3
**www.recom-power.com**
**==> picture [526 x 608] intentionally omitted <==**
**----- Start of picture text -----**<br>
RACD07<br>AC/DC Converter Series<br>Specifications (measured @ ta= 25°C and 115/230VAC)<br>DIMENSION and PHYSICAL CHARACTERISTICS<br>Parameter Type Value<br>case plastic (UL94V-2)<br>Material<br>potting silicone (UL94V-0)<br>Dimension (LxWxH) 57.0 x 40.8 x 24.0mm<br>—— Weight — 75g<br>Dimensions Drawing (mm)<br>57.0<br>49.0<br>150±10<br>Wired Connection<br>3 # Function Wire Color Type<br>4 1 VAC in (L) brown UL-1007, AWG18<br> 2 VAC in (N) blue UL-1007, AWG18<br>11.0 tc 3 LED+ red UL-1007, AWG18<br> 4 LED- black UL-1007, AWG18<br>tc= case temperature measuring point<br>FC = fixing centers<br>Tolerance: xx.x= ±0.5mm<br>1<br>2<br>FC 4.5<br>=<br>40.8<br>R er o——<br>INSTALLATION and APPLICATION<br>Connection<br>L N<br>LED+<br>LED-<br>SEC<br>17.0<br>39.2 4.0 15.3<br>PRI<br>22.2 24.0<br>2.0<br>**----- End of picture text -----**<br>
Connection L N LED+ LEDPACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) cardboard box 286.0 x 201.0 x 88.0mm Packaging Quantity 25pcs Storage Temperature Range -40°C to +85°C ~~a~~ Storage Humidity non condensing 10% - 90% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV.: 4/2019
L-4
**www.recom-power.com**
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →