• Universal input 80-264VAC
## Features
• High efficiency up to 77%
• Isolated output 3kVAC/1 minute
## Regulated Converters
• Short circuit protection • Meet EN55032 class B • Low standby power consumption
## Description
Compact, low cost, high efficiency, universal input switching AC/DC power module for PCB or wired mounting with single or dual outputs. CE/EAC marked and UL/cUL certified.
## Selection Guide
## **AC/DC Converter**
## **RAC05-C**
## **5 Watt Single & Dual Output**
|Part|Input|Output|Output|Efficiency|Max. Capacitive|
|---|---|---|---|---|---|
|Number|Voltage Range|Voltage|Current|typ(1)|Load(2,3)|
|RAC05-3.3SC(4)|[VAC]<br>80-264|[VDC]<br>3.3|[mA]<br>1250|[%]<br>70|[µF]<br>12000|
|RAC05-05SC(4)|80-264|5|1000|73|6800|
|RAC05-09SC(4)|80-264|9|556|75|2500|
|RAC05-12SC(4)<br>80-264<br>12<br>420<br>76<br>1500<br>RAC05-15SC(4)<br>80-264<br>15<br>340<br>76<br>750<br>~~i~~<br>~~————————————————S~~||||||
|RAC05-24SC(4)|80-264|24|210|77|330|
|RAC05-05DC(4)|80-264|±5|±500|73|±3000|
|RAC05-12DC(4)<br>RAC05-15DC(4)|80-264<br>80-264|±12<br>±15|±210<br>±170|76<br>76|±560<br>±220|
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load
Note3: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM Techsupport for detailed information
## Model Numbering
**E224736**
UL60950-1 certified CAN/CSA-C22.2 No. 60950-1 certified IEC/EN60950-1 certified EN55032 compliant EN55024 compliant
## RAC05-__ _C/W
nom. Output Power **W** ired option[ (4)] nom. Output Voltage **S** ingle or **D** ual
## Notes:
Note4: add suffix „/W“ for wired version without suffix, standard THT version
## Ordering Examples:
RAC05-05SC 5 Watt 5Vout Single Output THT version RAC05-05SC/W 5 Watt 5Vout Single Output wired version RAC05-12DC 12 Watt 5Vout Dual Output THT version RAC05-12DC/W 12 Watt 5Vout Dual Output wired version
REV.: 1/2018
PA-1
**www.recom-power.com**
**RAC05-C Series**
**AC/DC Converter**
~~Lo~~ Specifications (measured at Ta= 25°C, full load otherwise noted)
BASIC CHARACTERISTICS ~~Ce~~ Parameter Condition Min. Typ. Max. ~~a~~ nom. Vin = 230VAC 80VAC 264VAC Input Voltage Range[(5)] 115VDC 370VDC ~~ee~~ 115VAC 110mA Input Current 230VAC 70mA ~~ee Gnen~~ ~~**Ge** eeen ee~~ 115VAC 30A Inrush Current <2ms 230VAC 60A ~~eeGee ee Ge er~~ No load Power Consumption 250mW Input Frequency Range AC Input 47Hz 440Hz Minimum Load 0% ~~nrrr rs~~ Hold-up time ~~rr~~ 115VAC 10ms ~~rs~~ Internal Operating Frequency 100% load at nominal Vin 132kHz 3.3Vout 120mVp-p ~~ee~~ Output Ripple and Noise[(6)] ~~Ge~~ 20MHz BW ~~ee~~ all others ~~Ge es~~ 150mVp-p Notes: Note5: Refer to line derating graph on page PA-3 Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
**==> picture [475 x 205] intentionally omitted <==**
**----- Start of picture text -----**<br>
Vin=115VAC Vin=230VAC<br>100 100<br>90 a 90 fn<br>80 PT TT EE 80 ee<br>70 ee ae eee 70 ee<br>60 Pa 60 |gem<br>50 fF 50 | | |<br>40 Fi | | | | | [ ff| | | 40 fedT | || |tT ct| ct| |Ttft ld<br>30 30<br>20 PoE 24Vout 20 ee 24Vout<br>12Vout 12Vout<br>10 5Vout 10 5Vout<br>Poe) EE<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br>
|REGULATIONS|REGULATIONS|REGULATIONS|
|---|---|---|
|Parameter|Condition|Value|
|Output Accuracy||±2.0% max.|
|Line Regulation|low line to high line|±0.3% typ.|
|Load Regulation(7)|5% to 100% load|0.5% typ.|
|Notes:<br>Note7: Operation below 5% load will not harm the converter, but specifications may not be met|||
REV.: 1/2018
PA-2
**www.recom-power.com**
**RAC05-C Series**
**AC/DC Converter**
|PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS|
|---|---|---|---|---|
|Parameter|Type|||Value|
|Short Circuit Protection(SCP)|below 100mW|||Hiccupmode, automatic recovery|
|Over Voltage Protection (OVP)|zener diode clamp||3.3Vout<br>all others|145% - 165%<br>110% - 135%|
|Over Voltage Category||||OVCII|
|Isolation Voltage|I/P to O/P|tested for 1 minute||3kVAC|
|Isolation Resistance|I/P to O/P|||1GWmin.|
|Isolation Capacitance||||1000pF typ.|
|Leakage Current||||0.85mA max.|
|Notes:<br>Note8:<br>Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type|||||
Notes:
Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
**==> picture [525 x 360] intentionally omitted <==**
**----- Start of picture text -----**<br>
ENVIRONMENTAL<br>a<br>Parameter Condition Value<br>full load -25°C to +55°C<br>Operating Temperature Range [(8)] @ natural convection 0.1m/s<br>refer to derating graph -25°C to +75°C<br>ae ee eese e e<br>Operating Altitude 2000m<br>ee Operating Humidity non-condensing 95% RH max.<br>ee Pollution Degree PD2<br>+25°C >400 x 10 [3] hours<br>MTBF according to MIL-HDBK-217F, G.B.<br>+55°C >200 x 10 [3] hours<br>ee<br>Derating Graph Line Derating<br>(@Chamber and natural convection 0.1m/s)<br>100 100<br>90 90<br>80 80<br>70 PEERAREA = MEERA 70<br>PF | ft fT | hPL TT pf | { { | ft tt |<br>60 60<br>| | | td} vA pf | | tt | tt<br>50 50<br>Fo} fot tt A | | | | | ft | tt<br>40 40<br>P| ft | i A pj | | ft tT tt<br>30 30<br>ee ee ee pf | {| { | ft tt |<br>20 20<br>Seen p {| | | tt Tt<br>10 10<br>pF | ft} te tT pf | {| | | ft tt<br>0 0<br>-25 ee -10 5 20 35 50 65 80 ee 95 110 80 Pp 90 Et | | PT Tt 264<br>55 70 75<br>Ambient Temperature [°C] Input Voltage [VAC]<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br>
REV.: 1/2018
PA-3
**www.recom-power.com**
**RAC05-C Series**
**AC/DC Converter**
~~|~~ Specifications (measured at Ta= 25°C, full load otherwise noted) SAFETY AND CERTIFICATIONS ~~cn a~~ Certificate Type (Safety) ~~D~~ Report / File Number Standard UL60950-1, 2nd Edition, 2007 Information Technology Equipment - General Requirments for Safety E224736-A1-UL ~~a~~ CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007 IEC60950-1:2005 2nd Edition + A2:2013 Information Technology Equipment - General Requirments for Safety SPCLVD1605077-06 EN60950-1:2006 + A2:2013 ~~a~~ EAC Safety of Low Voltage Equipment RU-AT.AB37.B.02367 TP TC 004/2011 RoHS2+ RoHS-2011/65/EU + AM-2015/863 ~~> a~~ EMC Compliance Condition Standard / Criterion ~~Ge~~ Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2015 Information technology equipment - Immunity characteristics - Limits and EN55024:2010 + A1:2015 methods of measurement ~~a~~ ESD Electrostatic discharge immunity test Air ±8.0kV, Contact ±4.0kV IEC61000-4-2:2008, Criteria A ~~oo~~ Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2008, Criteria A ~~pf~~ Fast Transient and Burst Immunity AC Power Port: ±1.0kV IEC61000-4-4:2004, Criteria A ~~ee~~ Surge Immunity AC Power Port: L-N ±1.0kV IEC61000-4-5:2005, Criteria A ~~ee~~ Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3.0V IEC61000-4-6:2008, Criteria A Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2009, Criteria A Voltage Dips >95% IEC61000-4-11:2004, Criteria A Voltage Dips and Interruptions Voltage Dips 30% IEC61000-4-11:2004, Criteria A ~~ee~~ Voltage Interruptions > 95% IEC61000-4-11:2004, Criteria B ~~a~~ Limits of Harmonic Current Emissions ~~ee~~ EN61000-3-2:2014, Class A ~~a~~ Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|
|---|---|---|
|Parameter|Type|Value|
|Material|case<br>potting|black plastic (UL94V-0)<br>epoxy (UL94V-0)|
|Dimension (LxWxH)|single<br>dual|50.9 x 25.5 x 16.4mm<br>53.5 x 27.8 x 16.4mm|
|Weight|THT version<br>wired version|35g typ.<br>38gtyp.|
|continued on nextpage|||
continued on next page
REV.: 1/2018
PA-4
**www.recom-power.com**
## **AC/DC Converter**
## **RAC05-C Series**
Specifications (measured at Ta= 25°C, full load otherwise noted)
Dimension Drawing Single (mm)
**==> picture [290 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
embossed logo<br>50.9 25.5<br>5.0<br>Ø1.0 [±0.1] Recommended Footprint Details<br>restricted area 2.54<br>for PCB layout<br>2 + 1 TT _ SI : ; 3 rT|<br>Bottom View tc fo} 5.04 : Top View soe “ T + 1 |<br>: see 4<br>1 3 2<br>— —— fo} Yo [ t 4 - - L [ : So |<br>4 45.72<br>16.4<br>6.1 0.75<br>2.54<br>8.0 12.75<br>10.16<br>**----- End of picture text -----**<br>
**==> picture [110 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Connections<br> Pin # Single<br> 1 VAC in (N)<br> 2 VAC in (L)<br> 3 +VDC out<br> 4 -VDC out<br> 5 no pin<br>tc= case temperature measuring point<br>Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.25mm<br>**----- End of picture text -----**<br>
## Dimension Drawing Dual (mm)
**==> picture [289 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
embossed logo<br>53.5 27.8<br>5.0<br>Ø1.0 [±1.0] Recommended Footprint Details<br>restricted area 2.54<br>for PCB layout<br>5 : | =t t | q 3 an<br>° ° ret za i<br>2 1 + aN<br>5.0<br>Bottom View | tc 4 Top View | 4 : 111<br>.<br>:<br>1 3 2 Q 5<br>° °<br>|<br>45.72 — =t + + 4 - Ms | :<br>16.4<br>6.1 0.75<br>2.54<br>13.90 8.0<br>10.16<br>20.32<br>10.16<br>**----- End of picture text -----**<br>
**==> picture [113 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Connections<br>7 Pin # Dual<br> 1 VAC in (N)<br>7 2 VAC in (L)<br> 3 +VDC out<br> 4 Com<br>7 5 -VDC out<br>tc= case temperature measuring point<br>Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.25mm<br>**----- End of picture text -----**<br>
continued on next page
REV.: 1/2018
PA-5
**www.recom-power.com**
**RAC05-C Series**
## **AC/DC Converter**
**==> picture [263 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
LE Specifications (measured at Ta= 25°C, full load otherwise noted)<br>**----- End of picture text -----**<br>
**==> picture [504 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimension Drawing Single wired (mm) ~<br>embossed logo<br>50.9 25.5<br>5.0<br>Wired information<br># Function Wire color Type AWG<br>1 VAC in (N) blue UL-1015 22<br>arT Ø2.40 f_ Ø1.60 SLTT Ø0.76 I, Ø0.76 Al ee 2 VAC in (L) bown UL-1015 22<br>3 +VDC out red UL-1007 22<br>L brown 4 -VDC out black UL-1007 22<br>5.0<br>tc<br>Bottom View - black tc= case temperature measuring point<br>Tolerance: xx.x= ±0.5mm<br>N blue + red xx.xx= ±0.25mm<br>|<br>16.4<br>0.75<br>88.0<br>0.01<br>8.0<br>**----- End of picture text -----**<br>
## Dimension Drawing Dual wired (mm)
**==> picture [477 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
embossed logo<br>53.5 27.8<br>Wired information<br># Function Wire color Type AWG<br>1 VAC in (N) blue UL-1015 22<br>2 VAC in (L) bown UL-1015 22<br>[ Ø2.40 1 Ø1.60 ita<br>5.0 Ø0.76 3 +VDC out red UL-1007 22<br>- Orange 4 Com black UL-1007 22<br>L Brown tc 5.0 5 -VDC out orange UL-1007 22<br>Com Black<br>Bottom View tc= case temperature measuring point<br>Tolerance: xx.x= ±0.5mm<br>NBlue + Red xx.xx= ±0.25mm<br>16.4<br>0.75<br>88.0<br>0.01<br>8.0<br>**----- End of picture text -----**<br>
REV.: 1/2018
PA-6
**www.recom-power.com**
**RAC05-C Series**
**AC/DC Converter**
|PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION|
|---|---|---|---|
|Parameter|Type||Value|
|Packaging Dimension (LxWxH)|tube<br>cardbox|THT<br>wired|520.0 x 56.0 x 26.0<br>520.0 x 195.0 x 67.0|
|Packaging Quantity|THT single<br>THT dual<br>wired||10pcs<br>9pcs<br>20pcs|
|Storage Temperature Range|||-40°C to +100°C|
|Storage Humidity|non-condensing||95% RH max.|
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV.: 1/2018
PA-7
**www.recom-power.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →