RAC04-15SC
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 4 W, 15 VDC, 267 mA
- Manufacturer: RECOM POWER
- Product type: AC / DC PCB Mount Power Supplies
- Depth: 37.8mm
- Width: 23.9mm
- Height: 16.4mm
- Product Range: RAC04-SC
- No. of Outputs: 1 Output
- Output Power Max: 4W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 267mA
- Output Voltage - Output 1: 15VDC
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 8.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
**![NOT RECOMMENDED FOR NEW DESIGNS] ! (LAST TIME BUY: 30[TH] OCT 2020, 3.3, 9, 15VOUT / LAST TIME BUY 12[TH] AUG 2022 ALL OTHERS)** Features • Ultracompact AC-DC power supply • Universal input 80-264VAC or 115-370VDC **AC/DC Converter** • Class II power supply with 3kVAC isolation Regulated • Low cost AC/DC power supply • Short circuit & over current protected Converters • IEC/EN/UL60950 certified **RAC04-C** L_llooo ~~ee —_ oo~~ Description **4 Watt** **RAC04-C** L_llooo **4 Watt 3 Single Output** The new RAC04-SC modules are available with output voltages of 3.3, 5, 9, 12, 15, and 24V, and the input-to-output isolation is approximately 3kVAC/1min. With a standby consumption of typical 100mW, the mini power supplies are particularly suitable for energy-saving sleep mode and standby applications. Because of its compact design (height <17 mm), it is a versatile solution for home automation and other similar applications. Complete with an integrated input filter, the series has enhanced EMI performance and complies with EN55032, class B. The mini power supplies are also protected against short circuit with fully automatic restart after the error has been solved. The converters are EN/UL60950-1 certified and come complete with a 3 year warranty. |EOL (last time buy: 12thAUG 2022)<br>~~ee~~|EOL (last time buy: 12thAUG 2022)<br>~~ee~~|EOL (last time buy: 12thAUG 2022)<br>~~ee~~|EOL (last time buy: 12thAUG 2022)<br>~~ee~~|EOL (last time buy: 12thAUG 2022)<br>~~ee~~|EOL (last time buy: 12thAUG 2022)<br>~~ee~~| |---|---|---|---|---|---| |Part|Input|Output|Output|Efficiency|Max. Capacitive| |Number|Voltage Range|Voltage|Current|typ(1)|Load(2,3)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC04-05SC|80-264|5|800|72|2000| |RAC04-12SC|80-264|12|333|74|560| |RAC04-24SC|80-264|24|167|79|150| **==> picture [136 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> RoHScompliant10 from 102+ REACHcompliant<br>E224736<br>T T<br>ON ON<br>N P N P<br>C V C V<br>A R A R<br>E E<br>I O I O<br>M M<br>L L<br>R R<br>P D P D<br>O T O T<br>U U<br>C C<br>M M<br>E E<br>C C<br>E R E R<br>O T O T<br>R S R S<br>C S C S<br>**----- End of picture text -----**<br> ## EOL Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ[(1)] Load[(2,3)] [VAC] [VDC] [mA] [%] [µF] **E224736** RAC04-3.3SC 80-264 3.3 1200 67 5600 RAC04-09SC 80-264 9 444 76 1500 RAC04-15SC 80-264 15 267 77 470 ~~OO~~ Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load Note3: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM **PREFERRED ALTERNATIVES** Please consider these alternatives: Model Numbering **RAC04-GB Series** ~~oo~~ RAC04-__ SC = nom. Output Power **S** ingle nom. Output Voltage ~~ee~~ IEC/EN60950-1 certified UL60950-1 certified CAN/CSA-C22.2 No. 60950-1 certified ~~oo~~ Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) IEC/EN60950-1 certified UL60950-1 certified CAN/CSA-C22.2 No. 60950-1 certified EN55032 compliant EN55024 compliant CB-Report |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS| |---|---|---|---|---|---| |Parameter|Condition||Min.|Typ.|Max.| |Input Voltage Range(4,5)|nom. Vin = 230VAC||80VAC<br>115VDC||264VAC<br>370VDC| |Input Current|115VAC<br>230VAC||||110mA<br>72mA| |Inrush Current|<0.5ms cold start at +25°C|115VAC<br>230VAC|||30A<br>60A| |No load Power Consumption|80-264VAC||||200mW| |Input FrequencyRange|AC Input||47Hz||63Hz| |Minimum Load(7)|||10%||| |continued on nextpage|||||| continued on next page REV.: 6/2022 PA-1 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** **(LAST TIME BUY: 30[TH] OCT 2020, 3.3, 9, 15VOUT / LAST TIME BUY 12[TH] AUG 2022 ALL OTHERS)** ## **AC/DC Converter** ## **RAC04-C Series** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) ## BASIC CHARACTERISTICS |BASIC CHARACTERISTICS||||| |---|---|---|---|---| |Parameter|Condition|Min.|Typ.|Max.| |Internal OperatingFrequency|100% load at nominal Vin||40kHz|| |Output Ripple and Noise(6)|20MHz BW<br>115VAC/230VAC|||200mVp-p| **==> picture [526 x 371] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br> Note4: The products were submitted for safety files at AC-Input operation<br> Note5: Refer to line derating graph on page PA-3<br> Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)<br>Efficiency vs. Load RAC04-05SC RAC04-12SC<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>80VAC 80VAC<br>30 115VAC 30 115VAC<br>230VAC 230VAC<br>20 20<br>264VAC 264VAC<br>10 10<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>REGULATIONS<br>Parameter Condition Value<br>Output Accuracy ±2.0% typ./ ±5.0% max.<br>Line Regulation low line to high line ±0.5% typ./ ±1.0% max.<br>Load Regulation [(7)] 10% to 100% load 1.5% typ./ 5.0% max.<br>Notes:<br> Note7: Operation below 10% load will not harm the converter, but specifications may not be met<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> |PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS|PROTECTIONS| |---|---|---|---|---| |Parameter||Type||Value| |Short Circuit Protection(SCP)||below 100mW||Hiccupmode, automatic recovery| |Over Voltage Category||||OVCII| |Over Current Limit||||105% - 155%| |Isolation Voltage||I/P to O/P|tested for 1 minute|3kVAC| |Isolation Resistance||||1GWmin.| |Isolation Capacitance||||1000pF typ.| |Leakage Current||||0.85mA max.| |Notes:<br>Note8:<br>Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type<br>Note9:<br>MOV required for 230VAC operation. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 Series<br>-Vout<br>+Vout<br>L<br>N<br>F<br>U<br>VACin(L)<br>VACin(N)<br>+Vout<br>-Vout<br>Protection Circuit||||| REV.: 6/2022 PA-2 **www.recom-power.com** **(LAST TIME BUY: 30[TH] OCT 2020, 3.3, 9, 15VOUT / LAST TIME BUY 12[TH] AUG 2022 ALL OTHERS)** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **RAC04-C Series** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) |ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL| |---|---|---|---|---|---|---| |Parameter||Condition||||Value| |Operating Temperature Range||@ natural convection 0.1m/s|full load|||-25°C to +60°C| ||||refer to derating graph|||-25°C to +85°C| |Maximum Case Temperature||||||+100°C| |OperatingAltitude||||||2000m| |OperatingHumidity||non-condensing||||95% RH max.| |MTBF||accordingto MIL-HDBK-217F, G.B.||+25°C||500 x 103hours| |-25 -20<br>0<br>20<br>40<br>60<br>80<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Output Load [%]<br>Ambient Temperature [°C]<br>75<br>25<br>70<br>85<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Output Load [%]<br>Input Voltage [VAC]<br>80<br>130<br>180<br>230<br>280<br>85<br>90<br>264<br>Derating Graph<br>(@ Chamber and natural convection 0.1m/s)<br>Line Derating||||||| |||||||| |SAFETY AND CERTIFICATIONS||||||| |Certifcate Type(Safety)|||Report / File Number||Standard|| |Information Technology Equipment - General Requirments for Safety|||SPCLVD1606038||IEC60950-1:2005 2nd Edition + 2:2013<br>EN60950-1:2006 + A2:2013|| |Information Technology Equipment - General Requirments for Safety<br>(CB Scheme)|||L0339m10-CB-1-B1||IEC60950-1:2005 2nd Edition + A2:2013|| |Information TechnologyEquipment - General Requirments for Safety|||||EN60950-1:2006 + A2:2013|| |Information Technology Equipment - General Requirments for Safety|||E224736-A5-UL||CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007<br>UL No. 60950-1,2nd Edition,2007|| |EAC Safetyof Low Voltage Equipment|||RU-AT.49.09571||TP TC 004/2011|| |RoHS 2+|||||RoHS-2011/65/EU + AM-2015/863|| |||||||| |EMC Compliance|||Condition||Standard / Criterion|| |Electromagnetic compatibilityof multimedia equipment – Emission Requirements|||||EN55032:2015, Class B|| |Information technology equipment - Immunity characteristics - Limits and<br>methods of measurement|||||EN55024:2010 + A1:2015|| |ESD Electrostatic discharge immunitytest|||Air ±8.0kV; Contact ±4.0kV||IEC61000-4-2:2008, Criteria A|| |Radiated, radio-frequency, electromagnetic feld immunitytest|||3V/m||IEC61000-4-3:2006 + A2:2010, Criteria A|| |Fast Transient and Burst Immunity|||AC Power Port: ±1.0kV||IEC61000-4-4:2012, Criteria A|| |Surge Immunity|||AC Power Port: L-N ±1.0kV||IEC61000-4-5:2005, Criteria A|| |continued on nextpage||||||| REV.: 6/2022 PA-3 **www.recom-power.com** **(LAST TIME BUY: 30[TH] OCT 2020, 3.3, 9, 15VOUT / LAST TIME BUY 12[TH] AUG 2022 ALL OTHERS)** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **RAC04-C Series** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) |EMC Compliance|Condition|Standard / Criterion| |---|---|---| |Immunityto conducted disturbances, induced byradio-frequencyfields|AC Power Port: 3.0V|IEC61000-4-6:2008, Criteria A| |Voltage Dips and Interruptions|Voltage Dips >95%<br>Voltage Dips 30%<br>Voltage Interruptions > 95%|IEC61000-4-11:2004, Criteria A<br>IEC61000-4-11:2004, Criteria A<br>IEC61000-4-11:2004,Criteria C| |Limits of Voltage Fluctuations & Flicker||EN61000-3-3:2013| ## DIMENSION AND PHYSICAL CHARACTERISTICS **==> picture [521 x 387] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Type Value<br>case black plastic (UL94V-0)<br>Material<br>potting silicone (UL94V-0)<br>Dimension (LxWxH) 37.8 x 23.9 x 16.4mm<br>Weight 30g typ.<br> Dimension Drawing (mm) RECOM C<br>\ embossed logo<br>e<br>to 37.8 tI 23.9<br>Pin Connections<br> Pin # Single<br> 1 VAC in (L)<br> 3 VAC in (N)<br>13 NC<br>Ø 1.0 [+0.15/-0.05] 5.0 17.78<br>14 -VDC out<br>Recommended Footprint Details<br>restricted area 16 +VDC out<br>2.54<br>5.08 for PCB layout NC= no connection<br>P f tt Tolerance: xx.x= ±0.5mm<br>5 1 6 3 13 0 |Pees[seriesLibisptt 4eeeeeeeeeyy TT TTEEE Trt 16 EET 14 ftETelTt|<br>Bottom View hipLeetKR TT TTT To TT p View T<br>POPPITT TT TTT TTY<br>Pee<br>16 oO 14 Po 1 ee eg 3 13<br>±0.25 ±0.25<br>15.65 16.4<br>±0.25<br>0.75<br>6.10<br>3.06 2.54<br>17.78<br>**----- End of picture text -----**<br> ## PACKAGING INFORMATION |PACKAGING INFORMATION||| |---|---|---| |Parameter|Type|Value| |PackagingDimension(LxWxH)|tube|520.0 x 32.0 x 27.0mm| |PackagingQuantity||12pcs| |Storage Temperature Range|non-condensing|-40°C to +100°C| |Storage Humidity||95% RH max.| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 6/2022 PA-4 **www.recom-power.com**
Updated at February 9, 2023
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →