- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 30 |
| Price | 9.13 € |
| Current stock | 100+ |
| Lead time | 30 days |
Features • Universal input 85-264VAC • <250mW No load power consumption **AC/DC Converter** • -25°C to +80°C Operating temperature, with derating Regulated • Class II installations (without FG) • Continuous SCP, OCP Converter • IEC/EN/UL60950 & IEC/EN/UL62368 certified **RAC02-GB** ee ~~— Lo~~ Description **2 Watt** ‘n° | The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, “ Yarraw board level industrial applications. They feature universal AC input voltage range, regulated and **Single** short-circuit-proof isolated DC outputs, low standby power consumption and -25°C to +80°C operating temperature range. The RAC02-GB have a built-in Class B / FCC Part 15 EMC **Output** filter, are certified to EN60950 and EN62368 safety standards and come with a three year warranty.
## **Single Output EMC Class B**
|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|
|---|---|---|---|---|---|
|Number|Voltage Range|Voltage|Current|typ|Load(1)|
||[VAC]|[VDC]|[mA]|[%]|[µF]|
|RAC02-3.3SGB|85-264|3.3|500|63|500|
|RAC02-05SGB|85-264|5|400|63|500|
|RAC02-12SGB|85-264|12|167|68|200|
|RAC02-15SGB|85-264|15|140|63|200|
|RAC02-24SGB|85-264|24|83|63|200|
Notes:
Note1: Measured with all input voltages at +25°C with constant resistant mode at full load
## Model Numbering
**E196683** |
## RAC02-__ SGB
EMC Class B nom. Output Power nom. Output Voltage **S** ingle Ordering Examples: RAC02-12SGB 12Vout Single Output EMC Class B
ULIEC/EN60950-1 certified UL/IEC/EN62368-1 certified CAN/CSA-C22.2 No. 62368 certified IEC/EN62368-1 certified CB Report
REV.: 1/2018
PA-1
**www.recom-power.com**
**RAC02-GB Series**
**AC/DC Converter**
|Specifications(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~ee~~|
|---|
|BASIC CHARACTERISTICS<br>~~a~~|
|Parameter<br>Condition<br>Min.<br>Typ.<br>Max.<br>Internal Input Filter<br>Pi-type<br>Input Voltage Range(2,3,4)<br>nom. Vin = 230VAC<br>85VAC<br>230VAC<br>264VAC<br>~~ee~~<br>~~a~~<br>~~a~~|
|Input Current<br>115VAC<br>230VAC<br>50mA<br>30mA<br>~~a~~|
|Inrush Current<br>cold start at +25°C<br>115VAC<br>230VAC<br>30A<br>40A|
|No load Power Consumption<br>180mW<br>250mW<br>~~a~~|
|Input FrequencyRange<br>47Hz<br>63Hz<br>~~eS~~|
|Minimum Load<br>0%|
|Power Factor<br>115VAC<br>230VAC<br>0.55<br>0.42<br>~~ee~~|
|Start-up Time<br>115VAC<br>230VAC<br>250ms<br>200ms<br>2s<br>2s|
|Hold-up time<br>115VAC<br>230VAC<br>20ms<br>80ms|
|Internal OperatingFrequency<br>100% load at nominal Vin<br>65kHz|
|Output Ripple and Noise<br>20MHz BW<br>0°C to 80°C<br>3.3Vout<br>5Vout<br>12Vout<br>15Vout<br>24Vout<br>100mVp-p<br>100mVp-p<br>200mVp-p<br>200mVp-p<br>240mVp-p<br>-25°C to 0°C<br>3.3Vout<br>5Vout<br>12Vout<br>15Vout<br>24Vout<br>200mVp-p<br>200mVp-p<br>300mVp-p<br>300mVp-p<br>300mVp-p<br>pF)|
Notes: Note2: No proper operation with DC input voltage Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to line derating graph on page 4
Efficiency vs. Load
RAC02-05SGB
RAC02-12SGB
**==> picture [459 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
100 100<br>90 90<br>80 a 80<br>70 CAPE 70 a<br>60 a> 60 Doaeioe<br>50 7, 50 ee<br>40 vane 115VAC - 40 ,annn 115VAC -<br>230VAC 230VAC<br>30 fo ~ 30 PAE ~<br>20 foe - 20 PORE -<br>10 2a 10 POPPE ere<br>PPE Pe<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br>
REV.: 1/2018
PA-2
**www.recom-power.com**
**AC/DC Converter**
**Series**
## **RAC02-GB**
~~Lo~~ Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) REGULATIONS ~~Cn~~ Parameter Condition Value ~~ee ee~~ Output Accuracy -25°C to +80°C ±6.0% max. ~~Ce~~ Line Regulation -25°C to +80°C ±2.0% max. ~~Oe~~ Load Regulation -25°C to +80°C 6.0% max.
Deviation vs. Load RAC02-12SGB
**==> picture [465 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
RAC02-12SGB RAC02-24SGB<br>6 6<br>4 4<br>115VAC 115VAC<br>2 CUTE 230VAC 2 CEE 230VAC<br>NH +E<br>-2-4-60 CRECECECEEPOSSE CCCP REEEE -2-4-60 ==SetaCCC CCE ECE<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Deviation [%] Deviation [%]<br>**----- End of picture text -----**<br>
PROTECTIONS ~~|~~ Parameter Type Value ~~re~~ Input Fuse[(5)] internal fusible resistor, 1 W /1W ~~ee~~ Short Circuit Protection (SCP) below 100m W continuous, auto recovery ~~ee~~ Over Voltage Category OVCII 3.3Vout 0.67A - 1.81A 5Vout 0.44A - 1.20A Over Current Protection (OCP) 12Vout 0.18A - 0.50A hiccup mode 15Vout 0.15A - 0.42A 24Vout 0.09A - 0.25A ~~I~~ Class of Equipment Class II ~~Oe~~ Isolation Voltage[(6)] I/P to O/P rated for 1 minute 3kVAC Isolation Resistance 100M W min. ~~ee~~ Insulation Grade reinforced ~~ee es~~ Leakage Current I/P to O/P 0.25mA max.
Notes:
Note5: Refer to local safety regulations if input over-current protection is also required Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 series
## Protection Circuit
**==> picture [265 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
L N<br>FUSE<br>+VOUT<br>U<br>-VOUT<br>**----- End of picture text -----**<br>
REV.: 1/2018
PA-3
**www.recom-power.com**
**AC/DC Converter**
**Series**
## **RAC02-GB**
|Specifications(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~LT~~|
|---|
|ENVIRONMENTAL<br>Parameter<br>Condition<br>Value<br>Operating Temperature Range<br>@ natural convection 0.1m/s<br>full load<br>-25°C to +70°C<br>refer to derating graph<br>-25°C to +80°C<br>Maximum Case Temperature<br>+120°C<br>Temperature Coefficient<br>0.03%/K<br>~~a~~<br>~~nn~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~oo~~|
|OperatingAltitude(8)<br>4000m<br>~~a~~<br>~~a~~|
|OperatingHumidity<br>non-condensing<br>5% - 95% RH max.<br>Pollution Degree<br>PD2<br>Shock<br>10-150Hz, 2G 10min./1cycle,period 60min. each alongx,y,z axes<br>~~a~~<br>~~es~~<br>~~a~~<br>~~a~~|
|Vibration<br>accordingto MIL-STD-202G<br>20G/11mspulse, 3 times at each x,y, z axes<br>MTBF(9)<br>according to MIL-HDBK-217F, method 2<br>+25°C<br>+70°C<br>1691 x 103hours<br>424 x 103hours<br>Notes:<br>~~a~~<br>~~a~~<br>~~ee ee~~|
Note8: Recognized by UL for safe operation up to 4000m. High altitude operation may impact the performance and lifetime. Contact TechsupportAT@RECOM-POWER.com for advice
Note9: Based on calculation for 5Vout
## Derating Graph
(@ Chamber and natural convection 0.1m/s)
Line Derating
**==> picture [472 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
100 100<br>90 90<br>80 80<br>SHEEP = AEEEEEEEE<br>70 po 70 P| tT | tt Tt<br>60 eee eee 60 P| tT | Et Tt<br>50 50<br>40 SEEN] all other types 40 EERE EEE<br>RAC02-3.3SG<br>30 ps Ee 30 Pt ft tT | ET<br>20 Pot tT tT tT 20 P| tT | Et TT<br>10 Pot | | 10 P| ft tT |<br>0 0<br>-25 a -10 5 20 35 50 65 80 95 85 90 264<br>70<br>Ambient Temperature [°C] Input Voltage [VAC]<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br>
|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|
|---|---|---|
|Certificate Type(Safety)|Report / File Number|Standard|
|Information Technology Equipment, General Requirements for Safety|E196683-A5|UL60950-1, 2nd Edition 2014<br>CAN/CSA-C22.2 No. 60950-1, 2nd Edition 2015|
|Information Technology Equipment, General Requirements for Safety|16BAS10048 11<br>SA1804152L01001|IEC60950-1:2005 2nd Edition + Am2:2013<br>EN60950-1:2006 + A2:2013|
|Information Technology Equipment, General Requirements for Safety<br>(CB Scheme)|16BAS10048 11|IEC60950-1:2005 2nd Edition + Am2:2013|
|continued on nextpage|||
continued on next page
REV.: 1/2018
PA-4
**www.recom-power.com**
**RAC02-GB Series**
**AC/DC Converter**
|Specifications(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~LT~~|(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~LT~~<br>~~a~~|(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~LT~~|
|---|---|---|
|Certificate Type(Safety)<br>~~a~~|Report / File Number<br>~~a~~<br>~~a~~|Standard<br>~~a~~|
|Audio/Video, information and communication technology equipment - Part1:<br>Safetyrequirements<br>~~a~~<br>~~ee~~|E196683-A5<br>E196683-A6001<br>~~a~~<br>~~a~~<br>~~ee~~|UL62368-1, 2nd Edition<br>CAN/CSA-C22.2 No. 62368-1-14<br>~~a~~<br>~~ee~~|
|Audio/Video, information and communication technology equipment - Part1:<br>Safetyrequirements<br>~~ee~~|16BCS1004811<br>~~ee~~|IEC62368-1:2014 2nd Edition<br>EN62368-1:2014+A11:2017<br>~~ee~~|
|Audio/Video, information and communication technology equipment - Part1:<br>Safetyrequirements(CB Scheme)<br>~~ee~~|SA1804152S 001<br>~~ee~~|IEC62368-1:2014 2nd Edition<br>~~ee~~|
|RoHS2<br>~~ee~~<br>~~a~~<br>~~————————{~~|~~ee~~<br>~~a~~<br>~~a~~<br>~~————————{~~|RoHS 2011/65/EU<br>~~ee~~<br>~~a~~|
|~~a~~<br>~~a~~<br>~~a~~<br>~~————————{~~|||
|EMC Compliance<br>~~a~~<br>~~————————{~~<br>~~BC~~|Condition<br>~~a~~<br>~~a~~<br>~~————————{~~<br>~~-——~~|Standard / Criterion<br>~~a~~<br>~~-——~~|
|Electromagnetic compatibility of multimedia equipment - Emission<br>requirements<br>~~————————{~~<br>~~BC~~|EA1804152E 01001<br>~~a~~<br>~~————————{~~<br>~~-——~~|EN55032:2015, Class B<br>~~-——~~|
|Information technology equipment - Immunity characteristics - Limits and<br>methods of measurement<br>~~————————{~~<br>~~BC~~||EN55024:2010+A1:2015<br>~~-——~~<br>~~BC~~|
|ESD Electrostatic discharge immunity test<br>~~————————{~~<br>~~BC~~<br>~~en~~|Air ±2, 4, 8kV<br>Contact ±2,4kV<br>~~a~~<br>~~————————{~~<br>~~-——~~|EN61000-4-2:2009, Criteria A<br>~~-——~~<br>~~BC~~|
|Radiated, radio-frequency, electromagnetic field immunity test<br>~~en~~|3V/m|EN61000-4-3:2006 + A2:2010, Criteria A|
|Fast Transient and Burst Immunity<br>~~en~~|AC Power Port: ±1kV<br>~~a~~|EN61000-4-4:2012, Criteria A|
|Surge Immunity<br>~~en~~<br>~~a~~|AC Power Port: L-N ±1kV<br>~~a~~<br>~~a~~|EN61000-4-5:2014, Criteria B<br>~~a~~|
|Immunity to conducted disturbances, induced by radio-frequency fields<br>~~a~~<br>~~ee~~|AC Power Port 3V<br>~~a~~<br>~~a~~<br>~~ee~~|EN61000-4-6:2014, Criteria A<br>~~a~~<br>~~ee~~|
|Immunity to conducted disturbances, induced by radio-frequency fields<br>~~ee~~<br>~~a~~<br>~~——$———~~|50Hz, 1A/m<br>~~ee~~<br>~~a~~<br>~~——$———~~|IEC61000-4-8:2009; Criteria A<br>~~ee~~<br>~~a~~<br>~~——$———~~|
|Voltage Dips and Interruption<br>~~a~~<br>~~——$———~~<br>~~a~~<br>~~a~~|Voltage Dips >95%<br>~~a~~<br>~~——$———~~|EN61000-4-11:2004, Criteria A<br>~~a~~<br>~~——$———~~|
||Voltage Dips 30%<br>~~——$———~~<br>~~a~~|EN61000-4-11:2004, Criteria B<br>~~——$———~~<br>~~a~~|
||Voltage Interruptions >95%<br>~~——$———~~<br>~~a~~<br>~~a~~|EN61000-4-11:2004, Criteria B<br>~~——$———~~<br>~~a~~<br>~~a~~|
|Limits of Voltage Fluctuations & Flicker<br>~~——$———~~<br>~~a~~<br>~~a~~|~~——$———~~<br>~~a~~<br>~~a~~|EN61000-3-3:2013<br>~~——$———~~<br>~~a~~<br>~~a~~|
|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|
|---|---|---|
|Parameter|Type|Value|
|Material|case<br>PCB|black plastic (UL94V-2)<br>FR4(UL94V-0)|
|Dimension(LxWxH)||33.7 x 22.2 x 19.0mm|
|Weight||12gtyp.|
|continued on nextpage|||
continued on next page
REV.: 1/2018
PA-5
**www.recom-power.com**
**AC/DC Converter**
**Series**
## **RAC02-GB**
**==> picture [525 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
OTTO Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>**----- End of picture text -----**<br>
**==> picture [487 x 389] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimension Drawing (mm)<br>33.7<br>embossed logo<br>Pin Connections<br> Pin # Single<br>1 VAC in (L)<br> 2 VAC in (N)<br> 3 -Vout<br> 4 +Vout<br>Tolerance: xx.x= ±0.5mm<br>Pin width: ±0.05mm<br>2.85 15.24<br>Recommended Footprint Details<br>2.54<br>Ø0.8 [±0.03]<br>1 2 3<br>Bottom View 4 Top View 4<br>2 3 1<br>28.0 ce<br>22.2<br>19.0<br>±0.5<br>3.7<br>2.54<br>7.62<br>**----- End of picture text -----**<br>
|PACKAGING INFORMATION|PACKAGING INFORMATION|PACKAGING INFORMATION|
|---|---|---|
|Parameter|Type|Value|
|PackagingDimension(LxWxH)|tube|470.0 x 36.4 x 26.4mm|
|PackagingQuantity||20pcs|
|Storage Temperature Range||-25°C to +85°C|
|Storage Humidity|non-condensing|5% - 95% RH max.|
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV.: 1/2018
PA-6
**www.recom-power.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →