Image not available
Illustrative purposes only
RAC02-15SGA
POWER SUPPLY MODULE
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RECOM / PARTNER STOCK
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (04-Feb-2026)
- Product Range: RAC02-GA Series
| Delivery and price | |
|---|---|
| Units per pack | 30 |
| Price | 9.13 € |
| Current stock | 25+ |
| Lead time | 30 days |
## Features • Universal input 85-264VAC R • <250mW No load power consumption **AC/DC Converter** • -25°C to +80°C Operating temperature, with derating Regulated • Class II installations (without FG) • Continuous SCP, OCP Converter • IEC/EN/UL60950, IEC/EN/UL62368 & EN60335-1certified **RAC02-GA** ee a NEAR * Description **2 Watt** The RAC02-GA series are low cost AC/DC power supplies, ideal for PCB mounted, compact, barra board level industrial applications. They feature universal AC input voltage range, regulated and **Single** short-circuit-proof isolated DC outputs, low standby power consumption and -25°C to +80°C operating temperature range. The RAC02-GA have a built-in Class A / FCC Part 15 EMC filter, are **Output** certified to EN60335, EN60950 and EN62368 safety standards and come with a three year warranty. **EMC Class A** |Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia|Selection Guide<br>Part<br>Input<br>Output<br>Output<br>Efficiency<br>Max. Capacitive<br>aia| |---|---|---|---|---|---| |Number|Voltage Range|Voltage|Current|typ|Load(1)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC02-3.3SGA|85-264|3.3|500|63|500| |RAC02-05SGA|85-264|5|400|63|500| |RAC02-12SGA|85-264|12|167|68|200| |RAC02-15SGA|85-264|15|140|63|200| |RAC02-24SGA|85-264|24|83|63|200| |Notes:<br>Note1: Measured with all input voltages at +25°C with constant resistant mode at full load<br>~~eee~~|||||| ## Model Numbering ## RAC02-__ SGA EMC Class A nom. Output Power nom. Output Voltage **S** ingle Ordering Examples: RAC02-12SGA 12Vout Single Output EMC Class A **E196683** ) FAL UL/IEC/EN60950-1 certified CAN/CSA-C22.2 No. 62368 certified UL/IEC/EN62368-1 certified EN60335-1 certified CB Report REV.: 2/2018 PA-1 **www.recom-power.com** **RAC02-GA Series** **AC/DC Converter** ~~|~~ Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS ~~| GD~~ Parameter Condition Min. Typ. Max. ~~GC~~ Internal Input Filter Pi-type ~~Oe~~ Input Voltage Range[(2,3,4)] nom. Vin = 230VAC 85VAC 230VAC 264VAC 115VAC 50mA Input Current 230VAC 30mA ~~a~~ 115VAC 30A Inrush Current cold start at +25°C 230VAC 40A ~~a Oe~~ No load Power Consumption 180mW 250mW ~~a~~ Input Frequency Range 47Hz 63Hz Minimum Load 0% ~~ee~~ 115VAC 0.55 Power Factor 230VAC 0.42 ~~a~~ 115VAC 250ms 2s Start-up Time 230VAC 200ms 2s ~~a~~ 115VAC 20ms Hold-up time 230VAC 80ms ~~a a~~ Internal Operating Frequency 100% load at nominal Vin 65kHz 3.3Vout 100mVp-p 5Vout 100mVp-p 0°C to 80°C 12Vout 200mVp-p 15Vout 200mVp-p 24Vout 240mVp-p Output Ripple and Noise 20MHz BW 3.3Vout 200mVp-p 5Vout 200mVp-p -25°C to 0°C 12Vout 300mVp-p 15Vout 300mVp-p 24Vout 300mVp-p ## Notes: Note2: No proper operation with DC input voltage Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to line derating graph on page 4 Efficiency vs. Load RAC02-05SGA RAC02-12SGA **==> picture [473 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>90 PPP) 90 Er<br>80 80<br>| | | | dT dT dT TT | | ft | | dT | |<br>70 70<br>60 P|peel| | | 60 eeee<br>50 50<br>PO foe | | |Tonefor | | | | |<br>40 115VAC 40 115VAC<br>230VAC 230VAC<br>30 f-= 30<br>20 fi 4 20 eee<br>et | | | Fi | | ||<br>10 10<br>Fi | | | | | | | yt | | | | | |}<br>0 Pet || |TE hd}ETdT dT Tt | | 0 y P t |tT || |ET| dT TT<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> REV.: 2/2018 PA-2 **www.recom-power.com** **AC/DC Converter** **Series** ## **RAC02-GA** ~~Cn~~ Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) REGULATIONS ~~CO~~ Parameter Condition Value ~~RO a~~ Output Accuracy -25°C to +80°C ~~C~~ ±6.0% max. Line Regulation -25°C to +80°C ±2.0% max. ~~a a~~ Load Regulation -25°C to +80°C 6.0% max. Deviation vs. Load **==> picture [479 x 177] intentionally omitted <==** **----- Start of picture text -----**<br> RAC02-05SGA RAC02-12SGA<br>6 6<br>4 4<br>115VAC 115VAC<br>2 REECE 230VAC 2 CREE FE 230VAC<br>0 0<br>NTE Sept EE<br>-2 -2<br>CMEPFTA} ECD SEe<br>-4 -4<br>COSERECTT = EC<br>-6 -6<br>0 COOPTBESER} 10 20 30 40 50 60 70 80 90 100 = EOC 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Deviation [%] Deviation [%]<br>**----- End of picture text -----**<br> |PROTECTIONS<br>~~CO~~| |---| |Parameter<br>Type<br>Value| |Input Fuse(5)<br>internal<br>fusible resistor, 1W/1W<br>~~a~~| |Short Circuit Protection(SCP)<br>below 100mW<br>continuous, auto recovery<br>Over Voltage Category<br>OVCII<br>3.3Vout<br>0.67A - 1.81A<br>~~aa~~| |5Vout<br>0.44A - 1.20A| |Over Current Protection (OCP)<br>12Vout<br>0.18A - 0.50A<br>hiccup mode| |15Vout<br>0.15A - 0.42A| |24Vout<br>0.09A - 0.25A| |Class of Equipment<br>ClassII<br>Isolation Voltage(6)<br>I/P to O/P<br>rated for 1 minute<br>3kVAC<br>Isolation Resistance<br>100MWmin.<br>Insulation Grade<br>reinforced<br>Leakage Current<br>I/P to O/P<br>0.25mA max.<br>~~a~~<br>~~Ce~~<br>~~a~~<br>~~aee~~| Notes: Note5: Refer to local safety regulations if input over-current protection is also required Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 series ## Protection Circuit **==> picture [265 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> L N<br>FUSE<br>+VOUT<br>U<br>-VOUT<br>**----- End of picture text -----**<br> REV.: 2/2018 PA-3 **www.recom-power.com** **RAC02-GA Series** **AC/DC Converter** |Specifications(measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)<br>~~|~~| |---| |ENVIRONMENTAL<br>~~pT~~| |Parameter<br>Condition<br>Value| |Operating Temperature Range<br>@ natural convection 0.1m/s<br>full load<br>-25°C to +70°C<br>refer to derating graph<br>-25°C to +80°C<br>Maximum Case Temperature<br>+120°C<br>~~a~~<br>~~T_T~~| |Temperature Coefficient<br>0.03%/K<br>OperatingAltitude(8)<br>4000m<br>~~**e**e~~<br>~~C~~| |OperatingHumidity<br>non-condensing<br>5% - 95% RH max.<br>Pollution Degree<br>PD2<br>Shock<br>10-150Hz, 2G 10min./1cycle,period 60min. each alongx,y,z axes<br>Vibration<br>accordingto MIL-STD-202G<br>20G/11mspulse, 3 times at each x,y, z axes<br>MTBF(9)<br>according to MIL-HDBK-217F, method 2<br>+25°C<br>+70°C<br>1691 x 103hours<br>424 x 103hours<br>~~a~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~ee~~| Notes: Note8: Recognized by UL for safe operation up to 4000m. High altitude operation may impact the performance and lifetime. Please contact RECOM tech support for advice Note9: Based on calculation for 5Vout Derating Graph (@ Chamber and natural convection 0.1m/s) Line Derating **==> picture [481 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>90 90<br>80 a 80 SSS<br>70 70<br>p | | ft | | | | | | | rT |<br>60 60<br>eee ee | | | | | | TT<br>50 50<br>40 FESR all other types SEN) 40 Pose<br>RAC02-3.3SG<br>30 30<br>pa pf | | | |<br>20 20<br>Pp | | ft | P| | | | | TT<br>10 10<br>| | | | | | te pt | | | |<br>0 0<br>-25 eee -10 5 20 35 50 65 80 95 85 Ft 90 | tT tt 264<br>70<br>Ambient Temperature [°C] Input Voltage [VAC]<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br> |SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS| |---|---|---| |Certificate Type(Safety)|Report / File Number|Standard| |Household and similar electrical appliances – Safety– Part 1: General requirements|SES180313004001E|EN60335-1:2012+A11:2014| |Information Technology Equipment, General Requirements for Safety|E196683-A5|UL60950-1, 2nd Edition 2014<br>CAN/CSA-C22.2 No. 60950-1, 2nd Edition 2015| |Information Technology Equipment, General Requirements for Safety|16BAS10048 11<br>SA1804152L01001|IEC60950-1:2005 2nd Edition + Am2:2013<br>EN60950-1:2006 + A2:2013| |Information Technology Equipment, General Requirements for Safety<br>(CB Scheme)|16BAS10048 11|IEC60950-1:2005 2nd Edition + Am2:2013| |continued on nextpage||| continued on next page REV.: 2/2018 PA-4 **www.recom-power.com** **Series** ## **RAC02-GA** ## **AC/DC Converter** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) **==> picture [522 x 330] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Certificate Type (Safety)|Report / File Number|Standard| |Audio/Video, information and communication technology equipment - Part1:|E196683-A5|UL62368-1, 2nd Edition| |Safety requirements|E196683-A6001|CAN/CSA-C22.2 No. 62368-1-14| |Audio/Video, information and communication technology equipment - Part1:|IEC62368-1:2014 2nd Edition| |16BCS1004811| |Safety requirements|EN62368-1:2014+A11:2017| |Audio/Video, information and communication technology equipment - Part1:| |SA1804152S 001|IEC62368-1:2014 2nd Edition| |Safety requirements (CB Scheme)| |RoHS2|RoHS 2011/65/EU| |EMC Compliance|Condition|Standard / Criterion| |Electromagnetic compatibility of multimedia equipment - Emission| |EN55032:2015, Class A| |requirements| |EA1804152E 01001| |Information technology equipment - Immunity characteristics - Limits and| |EN55024:2010+A1:2015| |methods of measurement| |Air ±2, 4, 8kV| |ESD Electrostatic discharge immunity test|EN61000-4-2:2009, Criteria A| |Contact ±2, 4kV| |Radiated, radio-frequency, electromagnetic field immunity test|3V/m|EN61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity|AC Power Port: ±1kV|EN61000-4-4:2012, Criteria A| |Surge Immunity|AC Power Port: L-N ±1kV|EN61000-4-5:2014, Criteria B| |Immunity to conducted disturbances, induced by radio-frequency fields|AC Power Port 3V|EN61000-4-6:2014, Criteria A| |Immunity to conducted disturbances, induced by radio-frequency fields|50Hz, 1A/m|IEC61000-4-8:2009; Criteria A| |Voltage Dips >95%|EN61000-4-11:2004, Criteria A| |Voltage Dips and Interruption|Voltage Dips 30%|EN61000-4-11:2004, Criteria B| |Voltage Interruptions >95%|EN61000-4-11:2004, Criteria B| |Limits of Voltage Fluctuations & Flicker|EN61000-3-3:2013| **----- End of picture text -----**<br> EMI Filtering according to EN60335-1 / EN55032 Class B Compliance **==> picture [226 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> L +VOUT<br>N -VOUT<br>CY1 CY2<br>**----- End of picture text -----**<br> ## CY1,CY2 Vishay 564R30TSD22, SLCC X7R radial, 2.2nF, 3kVDC ±10% DIMENSION AND PHYSICAL CHARACTERISTICS **==> picture [522 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Parameter|Type|Value| |case|black plastic (UL94V-2)| |Material| |PCB|FR4 (UL94V-0)| |Dimension (LxWxH)|33.7 x 22.2 x 19.0mm| |Weight|12g typ.| **----- End of picture text -----**<br> continued on next page REV.: 2/2018 PA-5 **www.recom-power.com** **RAC02-GA Series** **AC/DC Converter** ~~Lo~~ Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) **==> picture [520 x 515] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing (mm)<br>33.7<br>embossed logo<br>a -<br>Pin Connections<br> Pin # Single<br>1 VAC in (L)<br> 2 VAC in (N)<br> 3 -Vout<br> 4 +Vout<br>Tolerance: xx.x= ±0.5mm<br>2.85 15.24 Pin width: ±0.05mm<br>Recommended Footprint Details<br>2.54<br>Ø0.8 [±0.03]<br>1 2 3<br>Bottom View 4 Top View 4<br>2 3 1<br>28.0<br>cS<br>PACKAGING INFORMATION<br>Parameter Type Value<br>Packaging Dimension (LxWxH) tube 470.0 x 36.4 x 26.4mm<br>Packaging Quantity 20pcs<br>Storage Temperature Range -25°C to +85°C<br>Storage Humidity non-condensing 5% - 95% RH max.<br>22.2<br>19.0<br>±0.5<br>3.7<br>2.54<br>7.62<br>**----- End of picture text -----**<br> The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 2/2018 PA-6 **www.recom-power.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →